1.
Keiji Wada Shinichi Inabe Hideaki Fujita Hirofumi Akagi Noboru Shibamaru 《Electrical Engineering in Japan》2002,138(1):14-23
This paper deals with dispersed installation of voltage‐detection based shunt active filters for harmonic damping throughput a power distribution system. A main objective of the active filters is to achieve damping of harmonic propagation coming from series/parallel resonance between capacitors for power factor correction and line inductors in the distribution system. Either a harmonic current source or a harmonic voltage source is connected to a distribution system simulator consisting of two distribution feeders, each of which is rated at 200 V and 20 kW. A couple of active filters are installed to the simulator. As a result, it is clarified by experiment that dispersed installation on the end bus of each feeder is effective in attenuating the harmonic propagation. © 2001 Scripta Technica, Electr Eng Jpn, 138(1): 14–23, 2002 相似文献
2.
在地震作用下,电容器成套装置容易受到破坏。对某种型号35 kV电容器成套装置的抗震性能进行鉴定分析,并对GB 50260-1996《电力设施抗震设计规范》和IEEE Std 693-2005标准推荐的抗震验算方法进行比较分析。应用通用有限元程序ANSYS建立此电容器结构体系的有限元模型,进行了地震作用下的动力反应分析。分别输入正弦共振调幅五波、Elcentro波、Landers波和人工波的动力时程分析结构的响应。通过增加2个绝缘支柱瓷瓶,此电容器成套装置满足抗震性能的要求。电容器的抗震性能高于IEEE Std 693-2005定义的中等抗震水平,略低于高等抗震水平。 相似文献
3.
消除PWM逆变器驱动交流电动机长线电缆影响的无源滤波技术 总被引:5,自引:0,他引:5
PWM逆变器驱动的交流电动机 ,在采用长线电缆传输时 ,会产生一系列问题 ,如电动机端过电压、高频阻尼振荡以及绝缘快速老化等。采用一定的无源滤波技术可有效地解决这些问题。根据滤波器的安装位置 ,可分为电动机端滤波和逆变器输出滤波。分析了长线电缆传输时的电压反射现象 ,论述了三种电动机端滤波器和四种逆变器输出滤波器 ,这些滤波器皆可有效地消除电动机端过电压和高频阻尼振荡等问题。 相似文献
4.
在非线性负荷和分布式电源大量接入配电网的背景下,配置有源电力滤波器是解决电压波形畸变、谐波损耗激增、电能质量下降等一系列谐波污染问题的有效措施之一。为合理选择配电网中有源电力滤波器安装位置与容量,协调谐波治理成本和效果之间的关系,文中提出一种基于灵敏度分析的有源电力滤波器多目标优化配置方法,实现了有源滤波器位置和容量的快速求解。建立配电网谐波潮流计算模型,使用灵敏度分析方法处理所有节点,获得了安装节点集合;考虑节点电压的谐波畸变率和投资成本,建立滤波器容量优化模型;通过分解多目标进化算法求解优化模型;对IEEE 18节点配电系统进行仿真计算,结果表明了文章所提方法的有效性。 相似文献
5.
6.
SRTM基线测量中的非线性滤波方法 总被引:1,自引:1,他引:1
基线测量精度对于SRTM高程测量精度影响很大,SRTM基线测量的关键是CCD相机对副天线上的LED灯进行质心定位,其结果含有的误差在后期干涉处理时需进一步滤除。鉴于LED运动呈非线性,本文对无迹RTS平滑,粒子滤波,无迹粒子滤波3种非线性滤波进行了研究,使用依赖于幅度的刚性模型叠加不同标准差的加性噪声模拟测量值,改进状态空间模型与滤波器参数设置,分别在有/无加速度计辅助测量的条件下进行仿真,结果表明无迹粒子滤波的效果优于其他方法,使用加速度计对于滤波精度普遍有所提高。 相似文献
7.
8.
9.
《Electric Power Systems Research》2005,73(2):129-136
Commonly used compact fluorescent lamps (CFLs) with electronic gear are characterized by extremely distorted current, with total harmonic distortion (THD) usually exceeding 100%. That is why they cause a significant voltage distortion in electrical installations. The principal goal of this research was to determine their maximum permissible share in the total load installed for commercial customers, at which voltage distortion is still acceptable (according to international standards). An analysis regarding a low-voltage electrical installation of a hotel, representing a typical commercial customer, showed that maximum permissible share should not exceed 10%. As this maximum permissible share could restrict the installment of the intended quantity of CFLs, the costs of two possible solutions for this problem – the use of filters or a new generation of CFLs with a high power factor – are compared. 相似文献
10.
Andrei R.G. Keri A.J.F. Albanese R.J. Johnson P.B. 《Power Systems, IEEE Transactions on》1993,8(4):1463-1470
As an alternative to the conventional shunt capacitor bank installation, a totally new concept of providing reactive power to an electrical power system is presented. A new type of capacitor bank installation called “bridge” is described. An analytical investigation of the bridge capacitor installation concept and its application in an EHV electrical power system is presented. The technical and economic advantages of the bridge capacitor bank over the shunt capacitor bank are analyzed in the context of the reactive power being directly supplied to an EHV system. A field trial installation at a lower than EHV level (138/69 kV) along with some experimental test results are presented 相似文献
11.
12.
考虑谐波源随机过程的配电网络滤波装置优化配置 总被引:1,自引:2,他引:1
电力系统中非线性负荷所产生的谐波电流随时间的变化实际上是一种非平衡随机过程,因此文中提出了一种近似的处理方法,将随机过程适当地划分成若干个时间段,每人时段中将各谐波源处理为考虑了谐波源之间的相关性的随机变量。在此基础上,文中提出了一种有源和无源滤波器统一优化配置的机会约束规划模型,给出了用基于随机模拟的遗传算法进行求解的方法。模型以有源和无源滤波器总费用最小为目标,优化其安装地点及参数,并给出一18节点配电系统的算例。算例结果表明,考虑成随机过程后,能更好地合乎配电网的实际情况,使所需费用较小且能有效地抑制谐波。 相似文献
13.
14.
M. F. Fahmy M. Abo-Zahhad G. A. El-Raheem 《International Journal of Circuit Theory and Applications》1994,22(6):467-477
In this paper a new synthesis method has been proposed for the design of 2D scaled state space filters with fixed point arithmetic. It is based on constructing a non-singular transformation matrix which minimizes the output noise power and maintains the signal-scaling condition, besides zeroing some of the entries of the state matrices. As a result, simultaneous savings in both additions and multiplications are achieved. Numerical results are included to illustrate the performance of the proposed structures and to compare them with other structures. 相似文献
15.
复龙换流站并联电容器成套装置的设计总结 总被引:2,自引:2,他引:0
主要对向家坝-上海±800kV特高压直流(UHVDC)工程复龙换流站并联电容器成套装置的研发、设计、配平、组装进行了总结.通过对装置的结构分析、特点介绍、抗风抗震的理论分析、配平组装等,说明复龙换流站电容器成套装置的结构设计合理,绝缘配合安全系数大,组架结构具有足够的强度和刚度,满足该地区的抗风抗震要求.先进的生产设备... 相似文献
16.
基于多谐波源动态运行的配电网滤波装置优化配置 总被引:2,自引:2,他引:0
在一个配电网中往往同时存在多个谐波源,且工作时间不确定,为提高遗传算法的搜索效率,利用分级递阶的自适应遗传算法对配电网中的无源滤波器(Passive Power Filter,PPF)和有源滤波器(Active Power Filter,APF)进行统一优化配置。用该算法在多谐波源动态运行的整个配电网中分级优化PPF和APF的安装地点、安装类型、安装参数,即先确定安装地点,再确定安装类型和安装组数,最后确定滤波器的参数,在满足谐波潮流约束条件的前提下,在控制滤波装置初期投资费用的同时有效抑制谐波。算例计算结果证明了该算法的有效性。 相似文献
17.
对深圳220 kV鹏新线/110 kV华昌线采用不同电压等级多回输电线路同塔架设进行研究,建立仿真分析模型,分析了继电保护、过电压、相邻线路之间的电磁感应和潜供电流等,提出相应的安全防护措施,认为不同电压等级多回路输电线路共塔架设方案是可行的. 相似文献
18.
19.
分析沙河电厂2台600 M W超临界机组空冷系统安装过程中出现大量漏点的问题,从空冷岛钢平台结构以上部分安装、大排汽管道系统安装、焊接工艺、严密性试验过程等方面提出空冷系统真空泄漏的控制措施及要点,并说明控制措施的实施效果。 相似文献
20.
基于IP核的SpaceWire-PCI通信卡设计 总被引:5,自引:0,他引:5
作为一种面向航天应用的通信技术,SpaceWire具有广阔的应用前景。以IP核技术为基础,设计实现了以PCI总线为集成平台的两通道SpaceWire接口通信卡。在对板卡硬件组成进行综述的基础上,详细描述了PCI接口IP核、SpaceWire节点IP核以及驱动程序的设计方法,最后通过软件定时方法对本板卡的转换效率进行了测试。本文设计的通信卡具有尺寸小、布线简单、成本低、功耗低等特点,可以满足航天测控领域需求。 相似文献