首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The study examines a novel system that combined a solid oxide fuel cell (SOFC) and an organic Rankine cycle (ORC) for cooling, heating and power production (trigeneration) through exergy analysis. The system consists of an SOFC, an ORC, a heat exchanger and a single-effect absorption chiller. The system is modeled to produce a net electricity of around 500 kW. The study reveals that there is 3-25% gain on exergy efficiency when trigeneration is used compared with the power cycle only. Also, the study shows that as the current density of the SOFC increases, the exergy efficiencies of power cycle, cooling cogeneration, heating cogeneration and trigeneration decreases. In addition, it was shown that the effect of changing the turbine inlet pressure and ORC pump inlet temperature are insignificant on the exergy efficiencies of the power cycle, cooling cogeneration, heating cogeneration and trigeneration. Also, the study reveals that the significant sources of exergy destruction are the ORC evaporator, air heat exchanger at the SOFC inlet and heating process heat exchanger.  相似文献   

2.
This study presents an analysis and assessment study of an integrated system which consists of cryogenic air separation unit, polymer electrolyte membrane electrolyzer and reactor to produce ammonia for a selected case study application in Istanbul, Turkey. A thermodynamic analysis of the proposed system illustrates that electricity consumption of PEM electrolyzer is 3410 kW while 585.4 kW heat is released from ammonia reactor. The maximum energy and exergy efficiencies of the ammonia production system which are observed at daily average irradiance of 200 W/m2 are found as 26.08% and 30.17%, respectively. The parametric works are utilized to find out the impacts of inlet air conditions and solar radiation intensity on system performance. An increase in the solar radiation intensity results in a decrease of the efficiencies due to higher potential of solar influx. Moreover, the mass flow rate of inlet air has a substantial effect on ammonia production concerning the variation of generated nitrogen. The system has a capacity of 0.22 kg/s ammonia production which is synthesized by 0.04 kg/s H2 from PEM electrolyzer and 0.18 kg/s N2 from a cryogenic air separation unit. The highest exergy destruction rate belongs to PEM electrolyzer as 736.2 kW while the lowest destruction rate is calculated as 3.4 kW for the separation column.  相似文献   

3.
Solar‐driven polygeneration systems are promising technologies for covering many energy demands with a renewable and sustainable way. The objective of the present work is the investigation of a trigeneration system, which is driven by solar‐dish collectors. The examined trigeneration system includes an organic Rankine cycle (ORC), which operates with toluene, and an absorption heat pump, which operates with LiBr/H2O. The absorption heat pump is fed with heat by the condenser of the ORC, which operates at medium temperature levels (120°C to 150°C). The absorption heat pump produces both useful heat at 55°C and cooling at 12°C. The ORC produces electricity, and it is fed by the solar dishes. The examined ORC is a regenerative cycle with superheating. The total analysis is performed with a developed model in Engineering Equation Solver (EES). The system is investigated parametrically for different ORC heat‐rejection temperatures, different superheating levels in the turbine inlet, and various solar‐beam irradiation levels. Furthermore, the system is investigated on a yearly basis for the climate conditions of Athens (Greece) and for Belgrade (Serbia). It is found that the yearly system energy and exergy efficiencies are 108.39% and 20.92%, respectively, for Athens, while 111.38% and 21.50%, respectively, for Belgrade. The values over 100% for the energy efficiency are explained by the existence of a heat pump in the examined configuration. For both locations, the payback period is found close to 10 years and the internal rate of return close to 10%. The final results indicate that the examined configuration is a highly efficient and viable system, which operates only with a renewable energy source.  相似文献   

4.
Exergy analysis of a binary geothermal power plant is performed using actual plant data to assess the plant performance and pinpoint sites of primary exergy destruction. Exergy destruction throughout the plant is quantified and illustrated using an exergy diagram, and compared to the energy diagram. The sites with greater exergy destructions include brine reinjection, heat exchanger and condenser losses. Exergetic efficiencies of major plant components are determined in an attempt to assess their individual performances. The energy and exergy efficiencies of the plant are 4.5% and 21.7%, respectively, based on the energy and exergy of geothermal water at the heat exchanger inlet. The energy and exergy efficiencies are 10.2% and 33.5%, respectively, based on the heat input and exergy input to the binary Rankine cycle. The effects of turbine inlet pressure and temperature and the condenser pressure on the exergy and energy efficiencies, the net power output and the brine reinjection temperature are investigated and the trends are explained.  相似文献   

5.
In this paper we study an integrated PV/T absorption system for cooling and hydrogen production based on U.A.E weather data. Effect of average solar radiation for different months, operating time of the electrolyzer, air inlet temperature and area of the PV module on power and rate of heat production, energy and exergy efficiencies, hydrogen production and energetic and exergetic COPs are studied. It is found that the overall energy and exergy efficiency varies greatly from month to month because of the variation of solar radiation and the time for which it is available. The highest energy and exergy efficiencies are obtained for the month of March and their value is 15.6% and 7.9%, respectively. However, the hydrogen production is maximum for the month of August and its value is 9.7 kg because in august, the solar radiation is high and is available for almost 13 h daily. The maximum energetic and exergetic COPs are calculated to be 2.28 and 2.145, respectively and they are obtained in the month of June when solar radiation is high for the specified cooling load of 15 kW.  相似文献   

6.
The thermodynamic performance of an industrial waste heat recovery‐based trigeneration system is studied through energy and exergy efficiency parameters. The effects of exhaust gas inlet temperature, process heat pressure, and ambient temperature on both energy and exergy efficiencies, and electrical to thermal energy ratio of the system are investigated. The energy efficiency increases while electrical to thermal energy ratio and exergy efficiency decrease with increasing exhaust gas inlet temperature. On the other hand, with the increase in process heat pressure, energy efficiency decreases but exergy efficiency and electrical to thermal energy ratio increase. The effect of ambient temperature is also observed due to the fact that with an increase in ambient temperature, energy and exergy efficiencies, and electrical to thermal energy ratio decrease slightly. These results clearly show that performance evaluation of trigeneration system based on energy analysis is not adequate and hence more meaningful evaluation must include exergy analysis. The present analysis contributes to further information on the role of exhaust gas inlet temperature, process heat pressure, ambient temperature influence on the performance of waste heat recovery‐based trigeneration from a thermodynamic point of view. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

7.
This paper deals with the experimental investigation of a magnesium chloride saturated solar pond and its performance evaluation through energy and exergy efficiencies. The solar pond system is filled with magnesium chloride containing water to form layers with varying densities. A solar pond generally consists of three zones, and the densities of these zones increase from the top convective zone to the bottom storage zone. The incoming solar radiation is absorbed by salty water (with magnesium chloride) which eventually increases the temperature of the storage zone. The high-temperature salty water at the bottom of the solar pond remains much denser than the salty water in the upper layers. Thus, the convective heat losses are prevented by gradient layers. The experimental temperature changes of the solar pond are measured by using thermocouples from August to November. The densities of the layers are also measured and analysed by taking samples from at the same point of the temperature sensors. The energy and exergy content distributions are determined for the heat storage zone and the non-convective zone. The maximum exergy destructions and losses appear to be 79.05 MJ for the heat storage zone and 175.01 MJ for the non-convective zone in August. The energy and exergy efficiencies of the solar pond are defined as a function of solar radiation and temperatures. As a result, the maximum energy and exergy efficiencies are found to be 27.41% and 26.04% for the heat storage zone, 19.71% and 17.45% for the non-convective zone in August, respectively.  相似文献   

8.
Analysis and performance assessment of a solar driven hydrogen production plant running on an Mg–Cl cycle, are conducted through energy and exergy methods. The proposed system consists of (a) a concentrating solar power cycle with thermal energy storage, (b) a steam power plant with reheating and regeneration, and (c) a hybrid thermochemical Mg–Cl hydrogen production cycle. The results show that higher steam to magnesium molar ratios are required for full yield of reactants at the hydrolysis step. This ratio even increases at low temperatures, although lowering the highest temperatures appears to be more favorable for linking such a cycle to lower temperature energy sources. Reducing the maximum cycle temperature decreases the plant energy and exergy efficiencies and may cause some undesirable reactions and effects. The overall system energy and exergy efficiencies are found to be 18.8% and 19.9%, respectively, by considering a solar heat input. These efficiencies are improved to 26.9% and 40.7% when the heat absorbed by the molten salt is considered and used as a main energy input to the system. The highest exergy destruction rate occurs in the solar field which accounts for 79% of total exergy destruction of the integrated system.  相似文献   

9.
This paper investigates the performance of a high temperature Polymer Electrolyte Membrane (PEM) electrolyzer integrated with concentrating solar power (CSP) plant and thermal energy storage (TES) to produce hydrogen and electricity, concurrently. A finite-time-thermodynamic analysis is conducted to evaluate the performance of a PEM system integrated with a Rankine cycle based on the concept of exergy. The effects of solar intensity, electrolyzer current density and working temperature on the performance of the overall system are identified. A TES subsystem is utilized to facilitate continuous generation of hydrogen and electricity. The hydrogen and electricity generation efficiency and the exergy efficiency of the integrated system are 20.1% and 41.25%, respectively. When TES system supplies the required energy, the overall energy and exergy efficiencies decrease to 23.1% and 45%, respectively. The integration of PEM electrolyzer enhances the exergy efficiency of the Rankine cycle, considerably. However, it causes almost 5% exergy destruction in the integrated system due to conversion of electrical energy to hydrogen energy. Also, it is concluded that increase of working pressure and membrane thickness leads to higher cell voltage and lower electrolyzer efficiency. The results indicate that the integrated system is a promising technology to enhance the performance of concentrating solar power plants.  相似文献   

10.
A solar transcritical CO2 power cycle for hydrogen production is studied in this paper. Liquefied Natural Gas (LNG) is utilized to condense the CO2. An exergy analysis of the whole process is performed to evaluate the effects of the key parameters, including the boiler inlet temperature, the turbine inlet temperature, the turbine inlet pressure and the condensation temperature, on the system power outputs and to guide the exergy efficiency improvement. In addition, parameter optimization is conducted via Particle Swarm Optimization to maximize the exergy efficiency of hydrogen production. The exergy analysis indicates that both the solar and LNG equally provide exergy to the CO2 power system. The largest amount of exergy losses occurs in the solar collector and the condenser due to the great temperature differences during the heat transfer process. The exergy loss in condenser could be greatly reduced by increasing the LNG temperature at the inlet of the condenser. There exists an optimum turbine inlet pressure for achieving the maximum exergy efficiency. With the optimized turbine inlet pressure and other parameters, the system is able to provide 11.52 kW of cold exergy and 2.1 L/s of hydrogen. And the exergy efficiency of hydrogen production could reach 12.38%.  相似文献   

11.
In this paper, we propose a new solar air heater with a packed-bed latent storage energy system using PCM spherical capsules. At daytime, the solar heating system stored the thermal solar energy as sensible and latent heat, however, at night it restored. Some parameters, such as the global solar radiation and the mass flow rate are varied to investigate their effect on the absorbed, used, and recovered heat from the system. An optimization study using the first and second laws of thermodynamics is also carried out to obtain the energy and exergy efficiencies. The experimental study was conducted, designed, and realized in the Research and Technology Center of Energy (CRTEn) in Tunisia. The experimentally obtained results are used to analyze the performance of the system, based on temperature distribution in different parts of the collectors, absorbed, instantaneous stored and used thermal energy. The daily energy efficiency varied between 32% and 45%. While the daily exergy efficiency varied between 13% and 25%. The effect of the mass flow rate of air on the outlet temperature of the solar air heater is examined.  相似文献   

12.
This study proposes a trigeneration system based on solid oxide fuel cell (SOFC) for generating power, cooling and heating simultaneously. The system mainly contains a SOFC, a gas turbine (GT), an organic Rankine cycle (ORC), a steam ejector refrigerator (SER) and a heat exchanger. The thermodynamic, exergoeconomic and exergoenvironmental models of proposed trigeneration system are developed, and the effects of design parameters on system performances are analyzed. The results indicate that the system average product cost and environmental impact per unit of exergy increase with SOFC inlet temperature and working pressure, the pinch point temperature difference and evaporating pressure of Generator, while decrease with the current density of fuel cell. Finally, optimization is performed to achieve the optimal exergy-based performance. It is revealed that though the system exergy efficiency is decreased by 7.64% after optimization, the system average product cost and environmental impact per unit of exergy are significantly reduced.  相似文献   

13.
Analysis of energy and exergy has been performed for a latent heat storage system with phase change material (PCM) for a flat-plate solar collector. CaCl2·6H2O was used as PCM in thermal energy storage (TES) system. The designed collector combines in single unit solar energy collection and storage. PCMs are stored in a storage tank, which is located under the collector. A special heat transfer fluid was used to transfer heat from collector to PCM. Exergy analysis, which is based on the second law of thermodynamics, and energy analysis, which is based on the first law, were applied for evaluation of the system efficiency for charging period. The analyses were performed on 3 days in October. It was observed that the average net energy and exergy efficiencies are 45% and 2.2%, respectively.  相似文献   

14.
The exergetic performance of concentrating type solar collector is evaluated and the parametric study is made using hourly solar radiation. The exergy output is optimized with respect to the inlet fluid temperature and the corresponding efficiencies are computed. Although most of the performance parameters, such as, the exergy output, exergetic and thermal efficiencies, stagnations temperature, inlet temperature, ambient temperature etc. increase as the solar intensity increases but the exergy output, exergetic and thermal efficiencies are found to be the increasing function of the mass flow rate for a given value of the solar intensity. The performance parameters, mentioned above, are found to be the increasing functions of the concentration ratio but the optimal inlet temperature and exergetic efficiency at high solar intensity are found to be the decreasing functions of the concentration ration. On the other hand, for low value of the solar intensity, the exergetic efficiency first increases and then decreases as the concentration ratio is increased. This is because of the reason that the radiation losses increase as the collection temperature and hence, the concentration ratio increases. Hence, for lower value of solar intensity, there is an optimal value of concentration ratio for a given mass flow rate at which the exergetic efficiency is optimal. Again it is also observed that the mass flow rate is a critical parameter for a concentrating type solar collector and should be chosen carefully.  相似文献   

15.
In this experimental study, solar energy was stored daily using the volcanic material with the sensible heat technique. The external heat collection unit consisted of 27 m2 of south‐facing solar air collectors mounted at a 55° tilt angle. The dimensions of the packed‐bed heat storage unit were 6 × 2 × 0.6 m deep. The packed‐bed heat storage unit was built under the soil. The heat storage unit was filled with 6480 kg of volcanic material. Energy and exergy analyses were applied in order to evaluate the system efficiency. During the charging periods, the average daily rates of thermal energy and exergy stored in the heat storage unit were 1242 and 36.33 W, respectively. Since the rate of exergy depends on the temperature of the heat transfer fluid and surrounding, the rate of exergy increased as the difference between the inlet and outlet temperatures of the heat transfer fluid increased during the charging periods. It was found that the average daily net energy and exergy efficiencies in the charging periods were 39.7 and 2.03%, respectively. The average daily net energy efficiency of the heat storage system remained nearly constant during the charging periods. The maximum energy and exergy efficiencies of the heat storage system were 52.9 and 4.9%, respectively. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

16.
In this study, a solar thermal based integrated system with a supercritical-CO2 (sCO2) gas turbine (GT) cycle, a four-step Mg–Cl cycle and a five-stage hydrogen compression plant is developed, proposed for applications and analyzed thermodynamically. The solar data for the considered solar plant are taken for Greater Toronto Area (GTA) by considering both daily and yearly data. A molten salt storage is considered for the system in order to work without interruption when the sun is out. The power and heat from the solar and sCO2-GT subsystems are introduced to the Mg–Cl cycle to produce hydrogen at four consecutive steps. After the internal heat recovery is accomplished, the heating process at required temperature level is supplied by the heat exchanger of the solar plant. The hydrogen produced from the Mg–Cl cycle is compressed up to 700 bar by using a five-stage compression with intercooling and required compression power is compensated by the sCO2-GT cycle. The total energy and exergy inputs to the integrated system are found to be 1535 MW and 1454 MW, respectively, for a 1 kmol/s hydrogen producing plant. Both energy and exergy efficiencies of the overall system are calculated as 16.31% and 17.6%, respectively. When the energy and exergy loads of the receiver are taken into account as the main inputs, energy and exergy efficiencies become 25.1%, and 39.8%, respectively. The total exergy destruction within the system is found to be 1265 MW where the solar field contains almost 64% of the total irreversibility with a value of ~811 MW.  相似文献   

17.
In this study, a new solar and geothermal based integrated system is developed for multigeneration of electricity, fresh water, hydrogen and cooling. The system also entails a solar integrated ammonia fuel cell subsystem. Furthermore, a reverse osmosis desalination system is used for fresh water production and a proton exchange membrane based hydrogen production system is employed. Moreover, an absorption cooling system is utilized for district cooling via available system waste heat. The system designed is assessed thermodynamically through approaches of energy and exergy analyses. The overall energy efficiency is determined to be 42.3%. Also, the overall exergy efficiency is assessed, and it is found to be 21.3%. The exergy destruction rates in system components are also analysed and the absorption cooling system generator as well as geothermal flash chamber are found to have comparatively higher exergy destruction rates of 2370.2 kW and 643.3 kW, respectively. In addition, the effects of varying system parameters on the system performance are studied through a parametric analyses of the overall system and associated subsystems.  相似文献   

18.
In this paper, a new renewable energy-based cogeneration system for hydrogen and electricity production is developed. Three different methods for hydrogen production are integrated with Rankine cycle for electricity production using solar energy as an energy source. In addition, a simple Rankine cycle is utilized for producing electricity. This integrated system consists of solar steam reforming cycle using molten salt as a heat carrier, solar steam reforming cycle using a volumetric receiver reactor, and electrolysis of water combined with the Rankine cycle. These cycles are simulated numerically using the Engineering Equation Solver (EES) based on the thermodynamic analyses. The overall energetic and exergetic efficiencies of the proposed system are determined, and the exergy destruction and entropy generation rates of all subcomponents are evaluated. A comprehensive parametric study for evaluating various critical parameters on the overall performance of the system is performed. The study results show that both energetic and exergetic efficiencies of the system reach 28.9% and 31.1%, respectively. The highest exergy destruction rates are found for the steam reforming furnace and the volumetric receiver reforming reactor (each with about 20%). Furthermore, the highest entropy generation rates are obtained for the steam reforming furnace and the volumetric receiver reforming reactor, with values of 174.1 kW/K and 169.3 kW/K, respectively. Additional parametric studies are undertaken to investigate how operating conditions affect the overall system performance. The results report that 60.25% and 56.14% appear to be the highest exergy and energy efficiencies at the best operating conditions.  相似文献   

19.
Exergy analysis of the solar cylindrical-parabolic cooker   总被引:2,自引:1,他引:1  
Richard Petela   《Solar Energy》2005,79(3):221-233
For the first time the simple solar parabolic cooker (SPC), of the cylindrical trough shape, is analysed from the exergy viewpoint. The paper presents the methodology of detailed exergy analysis of the SPC, the distribution of the exergy losses, and, on the example of the cooker surfaces, explains the general problem of how the exergy loss on any radiating surface, should be determined, if the surface absorbs many radiation fluxes of different temperatures. An imagined surface was used in the considerations to close the system of the cooker surfaces. It was shown that optimization is needed, to increase the energy and exergy efficiencies of the cooker.Equations for heat transfer between the three surfaces: cooking pot, reflector and imagined surface making up the system, were derived. The model allowed for theoretical estimation of the energy and exergy losses: unabsorbed insolation, convective and radiative heat transfer to the ambient, and additionally, for the exergy losses: the radiative irreversibilities on the surfaces, and the irreversibility of the useful heat transferred to the water.The exergy efficiency of the SPC, was found to be relatively very low (1%), and to be about 10 times smaller than the respective energy efficiency which is in agreement with experimental data from the literature. The influence of the input parameters (geometrical configuration, emissivities of the surfaces, heat transfer coefficients and temperatures of water and ambience) was determined on the output parameters, the distribution of the energy and exergy losses and the respective efficiencies.  相似文献   

20.
In this paper, energetic performance comparison of three trigeneration systems is presented. The systems considered are SOFC-trigeneration, biomass-trigeneration, and solar-trigeneration systems. This study compares the performance of the systems considered when there is only electrical power and the efficiency improvement of these systems when there is trigeneration. Different key output parameters are examined: energy efficiency, net electrical power, electrical to heating and cooling ratios, and (GHG) GHG (greenhouse gas) emissions. This study shows that the SOFC-trigeneration system has the highest electrical efficiency among the three systems. Alternatively, when trigeneration is used, the efficiencies of all three systems considered increase considerably. The maximum trigeneration efficiency of the SOFC-trigeneration system is around 76% while it is around 90% for the biomass-trigeneration system. On the other hand, the maximum trigeneration efficiencies of the solar-trigeneration system is around 90% for the solar mode, 45% for storage and storage mode, and 41% for the storage mode. In addition, this study shows that the emissions of CO2 in kg per MWh of electrical power are high for the biomass-trigeneration and SOFC-trigeneration systems. However, by considering the emissions per MWh of trigeneration, their values drop to less than one fourth.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏