首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
In this paper an analytical method has been proposed to predict the net ultimate uplift capacity of pile groups embedded in sand considering the arching effect. This method takes into consideration the embedded length (L), diameter of the pile (d), surface characteristics of pile, group configuration, spacing of the pile group (3d to 6d), and the soil properties. Arching develops due to relative compressibility of sand relative to pile which activates the soil–pile friction. As piles/pile groups move up, the active state of soil is initiated. The modified value of active earth pressure coefficient considering arching effect has been derived. Typical charts for evaluation of net ultimate uplift capacity for pile groups are presented through the figures. The predicted values of ultimate uplift capacity of pile groups with different configuration and slenderness ratios are compared with the available experimental results. The predicted values considering arching effect are found to be in good agreement with the data available from the literature.  相似文献   

2.
Pullout Behavior of Granular Pile-Anchors in Expansive Clay Beds In Situ   总被引:1,自引:0,他引:1  
Granular pile anchors (GPA) are one of the recent innovative foundation techniques devised for mitigating the problems posed by swelling clay beds. In a granular pile anchor, the footing is anchored to an anchor plate at the bottom of the granular pile. This makes the granular pile tension resistant and enables it to absorb the tensile force caused on the foundation by the swelling clay. An understanding of the amount of uplift resistance offered by the GPA is important in the design of granular pile-anchor foundations in field situations causing tensile forces on foundations, such as in expansive clay beds. This paper presents the results of a field-scale test program conducted to study the pullout response of GPAs embedded in expansive clay beds. Pullout load tests were conducted on GPAs of varying lengths and diameters. It was found from the field pullout load tests that granular pile anchors of larger surface area resulted in higher pullout capacity. Of the various single granular pile anchors with l/d values between 2.5 and 10, the GPA of length 1000?mm and diameter 200?mm (l/d = 5) showed the best pullout load response when tested alone, resulting in a failure uplift capacity of 14.71?kN. Increase in diameter and length of granular pile anchor increased the uplift capacity. When the length of the GPA was increased from 500 to 750 and 1000?mm, the percentage increase in the uplift load required for an upward movement of 25?mm was 33.3 and 55.5% respectively. The pullout load of the GPA when tested under group was 18?kN as against a 12?kN for the GPA when tested single.  相似文献   

3.
Most of the current design methods for driven piles were developed for closed-ended pipe piles driven in either pure clay or clean sand. These methods are sometimes used for H piles as well, even though the axial load response of H piles is different from that of pipe piles. Furthermore, in reality, soil profiles often consist of multiple layers of soils that may contain sand, clay, silt or a mixture of these three particle sizes. Therefore, accurate prediction of the ultimate bearing capacity of H piles driven in a mixed soil is very challenging. In addition, although results of well documented load tests on pipe piles are available, the literature contains limited information on the design of H piles. Most of the current design methods for driven piles do not provide specific recommendations for H piles. In order to evaluate the static load response of an H pile, fully instrumented axial load tests were performed on an H pile (HP?310×110) driven into a multilayered soil profile consisting of soils composed of various amounts of clay, silt and sand. The base of the H pile was embedded in a very dense nonplastic silt layer overlying a clay layer. This paper presents the results of the laboratory tests performed to characterize the soil profile and of the pile load tests. It also compares the measured pile resistances with those predicted with soil property- and in situ test-based methods.  相似文献   

4.
An experimental investigation of the shaft resistance of single vertical and batter piles pushed into sand was conducted. A prototype laboratory setup was designed for testing relatively large model piles, inclined at an angle that varied between zero and 30° with the vertical. Two model piles having diameters of 38 and 76 mm were tested at a ratio of the pile’s length to diameter up to 40, and subjected to axial compression loading. The pile models were instrumented to allow direct measurements of the shaft resistance. A theoretical model was developed to take into account the asymmetrical earth pressure distribution around the pile shaft, the level of mobilization of the angle of friction between the pile shaft and the sand, and the pile diameter. The results predicted by the theory developed agreed well with the experimental results of the present investigation as well as other experimental and field results available in the literature. Design charts are presented for use in practice. The results of the present investigation support the concept of the critical depth for the shaft resistance of vertical and batter piles driven in sand.  相似文献   

5.
Conventional pile materials such as steel, concrete, and timber are prone to deterioration for many reasons. Fiber-reinforced polymer (FRP) concrete composites represent an alternative construction material for deep foundations that can eliminate many of the performance disadvantages of traditional piling materials. However, FRP composites present several difficulties related to constructability, and the lack of design tools for their implementation as a foundation element. This paper describes the results of an experimental study on frictional FRP/dense sand interface characteristics and the constructability of FRP–concrete composite piles. An innovative toe driving technique is developed to install the empty FRP shells in the soil and self-consolidating concrete is subsequently cast in them. The experimental program involves interface shear tests on small FRP samples and uplift load tests on large-scale model piles. Two different FRP pile materials with different roughness and a reference steel pile are examined. Static uplift load tests are conducted on different piles installed in soil samples subjected to different confining pressures in the pressure chamber. The results showed that the interface friction for FRP materials compared favorably with conventional steel material. It was shown that toe driving is suitable for installation of FRP piles in dense soils.  相似文献   

6.
Load Testing of a Closed-Ended Pipe Pile Driven in Multilayered Soil   总被引:2,自引:0,他引:2  
Piles are often driven in multilayered soil profiles. The accurate prediction of the ultimate bearing capacity of piles driven in mixed soil is more challenging than that of piles driven in either clay or sand because the mechanical behavior of these soils is better known. In order to study the behavior of closed-ended pipe piles driven into multilayered soil profiles, fully instrumented static and dynamic axial load tests were performed on three piles. One of these piles was tested dynamically and statically. A second pile served as reaction pile in the static load test and was tested dynamically. A third pile was tested dynamically. The base of each pile was embedded slightly in a very dense nonplastic silt layer overlying a clay layer. In this paper, results of these pile load tests are presented, and the lessons learned from the interpretation of the test data are discussed. A comparison is made of the ultimate base and limit shaft resistances measured in the pile load tests with corresponding values predicted from in situ test-based and soil property-based design methods.  相似文献   

7.
Pipe piles can be classified as either closed- or open-ended piles. In the present paper, the load capacity of both closed- and open-ended piles is related to cone penetration resistance qc through an experimental program using calibration chamber model pile load tests and field pile load tests. A total of 36 calibration chamber pile load tests and two full-scale field pile load tests were analyzed. All the test piles were instrumented for separate measurement of each component of pile load capacity. Based on the test results, the normalized base resistance qb/qc was obtained as a function of the relative density DR for closed-ended piles, and of both the relative density DR and the incremental filling ratio (IFR) for open-ended piles. A relationship between the IFR and the relative density DR is proposed as a function of the pile diameter and driving depth. The relationship between IFR and DR allows the estimation of IFR and thus of the pile load capacity of open-ended piles at the design stage, before pile driving operations.  相似文献   

8.
In this research, centrifuge model pile-load tests were carried out to failure to investigate the behavior of large-diameter bored pile groups with defects. The model piles represented cast-in-place concrete piles 2.0?m in diameter and 15?m in length. Two series of static loading tests were performed. The first series of tests simulated the performance of a pile founded on rock and a pile with a soft toe. The second series of tests simulated the performance of three 2×2 pile groups: One reference group without defects, one group containing soft toes, and one group with two shorter piles not founded on rock. The presence of soft toes and shorter piles in the defective pile groups considerably reduced the pile group stiffness and capacity. As the defective piles were less stiff than the piles without defects, the settlements of the individual piles in the two defective pile groups were different. As a result, the applied load was largely shared by the piles without defects, and the defective pile groups tilted significantly. The rotation of the defective pile groups caused large bending moments to develop in the group piles and the pile caps. When the applied load was large, bending failure mechanisms were induced even though the applied load was vertical and concentric. The test results confirm findings from numerical analyses in the literature.  相似文献   

9.
This paper describes the results of a model testing of the piles embedded in Nak-Dong River sand, located in south Korea, under monotonic lateral loadings. A number of features were studied, including the lateral resistance of piles, the effect of the installation method, and the pile head restraint condition. The study has led to recommendations of the load–transfer curves (p–y curves) for laterally loaded piles. Modification factors were developed to allow for both a different pile installation method and different pile head restraint conditions by comparison to existing model load tests. The proposed p–y curves were compared to the existing curves and were evaluated with the experimental data. The ultimate lateral soil resistance and subgrade modulus were investigated and discussed. It is revealed that the proposed p–y curves show significant differences in shapes and magnitudes when compared with existing p–y curve models. The accuracy of the proposed p–y curve model, considering the effect of installation method and pile head restraint condition, is very reasonable as shown by comparing measured and predicted lateral behavior of the pile.  相似文献   

10.
When bored piles are installed through a jet grout layer, significant interaction may take place between the piles and the jet grout. Field load tests have indicated that significant enhancement of the pile shaft capacity and axial stiffness was possible for both compression and tension piles. The influence of the jet grout layer was more pronounced for piles under compression loading compared with uplift loading. The effectiveness of the jet grout in transmitting load via shearing action was dependent on the thickness of the grouted zone, the strength of the interlocks between individual jet grout columns forming the grout slab, as well as the interface bond between the pile shafts and the grout. No apparent adverse effect on the performance of permanent foundations was envisaged as a result of the presence of the jet grout layer. However, interpretation of pile behavior from load tests was complicated by the interaction between the test pile and jet grout, resulting in overprediction of pile capacity and axial stiffness. The significance of the interaction has to be carefully evaluated so that a correct interpretation of the true pile capacity and axial stiffness can be made.  相似文献   

11.
Shaft Capacity of Open-Ended Piles in Sand   总被引:1,自引:0,他引:1  
This paper presents the results from an experimental investigation designed to examine the effect of soil-core development and cyclic loading on the shaft resistance developed by open-ended piles in sand. An instrumented open-ended model pile was installed either by driving or jacking into an artificially-created loose sand deposit in Blessington, Ireland. The tests provided continuous measurements of the soil-core development and the radial effective stresses during installation and subsequent load tests. The equalized radial effective stresses developed at the pile-soil interface were seen to be dependent on the degree of soil displacement (plugging) experienced during installation, the distance from the pile toe, and the number of load cycles experienced by a soil element adjacent to the pile shaft. A new design method for estimating the shaft capacity of piles in sand is proposed and compared with measurements made on prototype field-scale piles.  相似文献   

12.
Group Interaction Effects on Laterally Loaded Piles in Clay   总被引:3,自引:0,他引:3  
This paper presents the results of static lateral load tests carried out on 1×2, 2×2, 1×4, and 3×3 model pile groups embedded in soft clay. Tests were carried out on piles with length to diameter ratios of 15, 30, and 40 and three to nine pile diameter spacing. The effects of pile spacing, number of piles, embedment length, and configuration on pile-group interaction were investigated. Group efficiency, critical spacing, and p multipliers were evaluated from the experimental study. The experimental results have been compared with those obtained from the program GROUP. It has been found that the lateral capacity of piles in 3×3 group at three diameter spacing is about 40% less than that of the single pile. Group interaction causes 20% increase in the maximum bending moment in piles of the groups with three diameter spacing in comparison to the single pile. Results indicate substantial difference in p multipliers of the corresponding rows of the linear and square pile groups. The predicted field group behavior is in good agreement with the actual field test results reported in the literature.  相似文献   

13.
This paper provides a rational method for evaluating a realistic lower bound for the base resistance of pipe piles in siliceous sand. Separate expressions are developed to represent the response to load of the pile plug, the sand below the pile base, and the sand below the pile annulus. These expressions are combined to give the overall base response of a pipe pile. Predicted responses are compared with databases compiled on the ultimate capacities of pipe piles and with base pressure-displacement characteristics observed in static load tests. The estimations are shown to match observed base resistances of large diameter piles for which the coring mode of penetration during driving dominates.  相似文献   

14.
An experimental study of the lateral behavior of vertical pile groups embedded in reinforced and nonreinforced sandy earth slopes was carried out. The model tests include studies of group configurations, pile spacing, embedment length of pile, relative densities of sand, and location of pile groups relative to the slope crest. Several configurations of geogrid reinforcement with different lengths, widths, and number of layers were used to reinforce a sandy slope of 1 (V): 1.5 (H). Pile groups of 2×2 and 3×3 along with center-to-center pile spacing of 2D, 3D, and 4.5D and piles with embedment length to diameter ratios of L/D = 12 and 22 were considered. Based on test results, geogrid parameters that give the maximum lateral capacity improvement are presented and discussed.  相似文献   

15.
Many transmission towers, high-rise buildings, and bridges are constructed near steep slopes and are supported by large-diameter piles. These structures may be subjected to large lateral loads, such as violent winds and earthquakes. Widely used types of foundations for these structures are pier foundations, which have large diameter with high stiffness. The behavior of a pier foundation subjected to lateral loads is similar to that of a short rigid pile, because both elements seem to fail by rotation developing passive resistance on opposite faces above and below the rotation point, unlike the behavior of a long flexible pile. This paper describes the results of several numerical studies performed with a three-dimensional finite-element method (FEM) of model tests and a prototype test of a laterally loaded short pile and pier foundation located near slopes, respectively. Initially, in this paper, the results of model tests of single piles and pile groups subjected to lateral loading, in homogeneous sand with 30° slopes and horizontal ground were analyzed by the three- dimensional (3D) finite-element (FE) analyses. Furthermore, field tests of a prototype pier foundation subjected to lateral loading on a 30° slope was reported. The FE analyses were conducted to simulate these results. The main purpose of this paper is the validation of the 3D elasto–plastic FEM by comparisons with the experimental data.  相似文献   

16.
This paper presents results of full-scale lateral load tests of one single pile and three pile groups in Hong Kong. The test piles, which are embedded in superficial deposits and decomposed rocks, are 1.5 m in diameter and approximately 30 m long. The large-diameter bored pile groups consist of one two-pile group at 6 D (D = pile diameter) spacing and one two-pile and one three-pile group at 3 D spacing. This paper aims to investigate the nonlinear response of laterally loaded large-diameter bored pile groups and to study design parameters for large-diameter bored piles associated with the p-y method using a 3 D finite-element program, FLPIER. Predictions using soil parameters based on published correlations and back-analysis of the single-pile load test are compared. It is found that a simple hyperbolic representation of load-deflection curves provides an objective means to determine ultimate lateral load capacity, which is comparable with the calculated values based on Broms' theory. Lateral deflections of bored pile groups predicted using the values of the constant of horizontal subgrade reaction, suggested by Elson and obtained from back-analysis of the single pile load test, are generally in good agreement with the measurements, especially at low loads.  相似文献   

17.
Permanent Strains of Piles in Sand due to Cyclic Lateral Loads   总被引:2,自引:0,他引:2  
The strain superposition concept, proposed for ballast study, is applied here to evaluate strain accumulation for laterally loaded piles in sand. It is shown that the soil properties, types of pile installation, cyclic loading types, pile embedded length, and pile∕soil relative stiffness ratio are important factors that influence the pile behavior under mixed lateral loads. These factors are quantified by means of a degradation factor, t, which is derived from the results of 20 full-scale pile load tests and then verified using 6 additional full-scale pile load tests.  相似文献   

18.
Ultimate Lateral Resistance of Pile Groups in Sand   总被引:1,自引:0,他引:1  
Experimental investigations on model pile groups of configuration 1 × 1, 2 × 1, 3 × 1, 2 × 2, and 3 × 2 for embedment length-to-diameter ratios L∕d = 12 and 38, spacing from 3 to 6 pile diameter, and pile friction angles δ = 20° and 31°, subjected to lateral loads, were conducted in dry Ennore sand obtained from Chennai, India. The load-displacement response, ultimate resistance, and group efficiency with spacing and number of piles in a group have been qualitatively and quantitatively investigated. Analytical methods have been proposed to predict the ultimate lateral capacity of single pile and pile groups. The proposed methods account for pile friction angle, embedment length-to-diameter ratio, the spacing of piles in a group, pile group configuration, and soil properties. These methods are capable of predicting the lateral capacity of piles and pile groups reasonably well as noted and substantiated by the comparison with the experimental results of the writers and other researchers.  相似文献   

19.
A large-scale field-monitoring program for studying residual forces in long-driven piles is described. Eleven steel H-piles, 34.2–59.8?m in embedded length, were instrumented with vibrating-wire strain gauges, installed and subjected to static loading tests in a building site in Hong Kong. The residual forces in these piles during and after pile installation were recorded. The development of residual forces as it relates to the pile penetration depth during construction, and in time after the piles were installed, is presented. The measured load transfers in the piles from static loading tests are reported and the effect of the residual forces on the interpretation of load-transfer behavior is studied. The field measurements show that residual forces increase approximately exponentially with penetration depth. The residual forces continue to increase with time after pile driving due to secondary compression of disturbed soils around the pile shaft and other factors. The large residual forces in the long piles significantly affect the interpretation of the pile load distributions. The effect of residual forces on the shaft resistance is significant at shallow depths. Bearing-capacity theory tends to overpredict the true toe resistance of the long piles founded in weathered soils.  相似文献   

20.
Centrifuge Modeling of Torsionally Loaded Pile Groups   总被引:1,自引:0,他引:1  
This paper reports a series of centrifuge model tests on torsionally loaded 1×2, 2×2, and 3×3 pile groups in sand. The objectives of the paper are to investigate: (1) the response of the pile groups subjected to torsion; (2) the way in which the applied torque is transferred in the pile groups; (3) the internal forces mobilized in these torsionally loaded pile groups and their contributions to resist the applied torque; and (4) the influence factors that affect the load transfer, such as soil density and pile-cap connection. In these model tests, the group torsional resistances of the pile groups increased monotonically in the test range of twist angles up to 8°. Both torsional and lateral resistances of the individual piles were simultaneously mobilized to resist the applied torque. The torsional resistances were substantially mobilized at small twist angles, while the lateral resistances kept increasing in the whole range of twist angles. Thus, the contribution of the torsional resistances to the applied torque decreased at large twist angles. The piles at different locations in a pile group could develop not only different horizontal displacements, but also different pile–soil–pile interactions and load–deformation coupling effect, hence, the torsional and lateral resistances of the piles are a function of pile location. The soil density had a more significant effect on the torsional resistances than on the lateral resistances of the group piles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号