This paper presents a comparative study of the condensation heat transfer coefficients in a smooth tube when operating with pure refrigerant R134a and its mixture with lubricant Castrol “icematic sw”. The lubricant is synthetic polyol ester based oil commonly used in lubricating the compressors. Two concentrations of R134a-oil mixtures of 2% and 5% oil (by mass) were analysed for a range of saturation temperatures of refrigerant R134a between 35 °C and 45 °C. The mass flow rate of the refrigerant and the mixtures was carefully maintained at 1 g/s, with a vapour quality varying between 1.0 and 0. The effects of vapour quality, flow rate, saturation temperature and temperature difference between saturation and tube wall on the heat transfer coefficient are investigated by analysing the experimental data. The experimental results were then compared with predictions from earlier models [Int J Heat Mass Transfer (1979), 185; 6th Int Heat Transfer Congress 3 (1974) 309; Int J Refrig 18 (1995) 524; Trans ASME 120 (1998) 193]. Finally two new empirical models were developed to predict the two-phase condensation heat transfer coefficient for pure refrigerant R134a and a mixture of refrigerant R134a with Castrol “icematic sw”. 相似文献
2.
In this study, the performance of a small-capacity directly cooled refrigerator was evaluated by using the mixture of R290 and R600a with mass fraction of 55:45 as an alternative to R134a. The compressor displacement volume of the alternative system with R290/R600a (55/45) was modified from that of the original system with R134a to match the refrigeration capacity. Both systems with R290/R600a (55/45) and R134a were tested, and then optimized by varying the refrigerant charge and capillary tube length under experimental conditions for both the pull-down test and the power consumption test. The refrigerant charge of the optimized R290/R600a system was approximately 50% of that of the optimized R134a system. The capillary tube lengths for each evaporator in the optimized R290/R600a system were 500 mm longer than those in the optimized R134a system. The power consumption of the optimized R134a system was 12.3% higher than that of the optimized R290/R600a system. The cooling speed of the optimized R290/R600a (55/45) system at the in-case setting temperature of −15 °C was improved by 28.8% over that of the optimized R134a system. 相似文献
3.
Dongsoo Jung Kilhong Song Kwangyong Ahn Jongkon Kim 《International Journal of Refrigeration》2003,26(7):764-771
Nucleate boiling heat transfer coefficients (HTCs) of binary and ternary mixtures composed of HFC32, HFC125, and HFC134a on a horizontal smooth tube of 19.0 mm outside diameter were measured. A cartridge heater was used to generate uniform heat flux on the tube. Data were taken in the order of decreasing heat flux from 80 kW m−2 to 10 kW m−2 with an interval of 10 kW m−2 in the pool temperature at 7 °C. HTCs of nonazeotropic mixtures of HFC32/HFC134a, HFC125/HFC134a, and HFC32/HFC125/HFC134a showed a reduction of HTCs as much as 40% from the ideal values while the near azeotropic mixture of HFC32/HFC125 did not show the reduction. Four of the well known correlations were compared against the present data for binary mixtures. Stephan and Körner's and Schlünder's correlations yielded a good agreement with a deviation of less than 10% but they can not be easily extended to multi-component mixtures of more than three components. A new correlation was developed utilizing only the phase equilibrium data and physical properties. A regression analysis was carried out to account for the reduction of HTCs and the final correlation, which can be easily extended to multi-component mixtures of more than three components, yielded a deviation of 7% for all binary and ternary mixtures. 相似文献
4.
M. Youbi-Idrissi J. Bonjour M. -F. Terrier C. Marvillet F. Meunier 《International Journal of Refrigeration》2004,27(3):1
In this paper, the impact of the oil presence on the performances of a refrigerating machine is investigated both experimentally and numerically. To highlight the effect of oil, particularly on the evaporator behaviour, a theoretical model of enthalpy calculation for a refrigerant/oil mixture has been previously developed [Int J Refrigeration, 26(2003), 284]. In order to validate this model, tests were carried out on an industrial refrigerating machine working with R-407C. The lubricant is a polyol-ester oil whose solubility curves are given by the oil manufacturer. The oil circulating mass fraction is measured by a sampling technique and by an on-line density measurement method, whose advantages and drawbacks are presented. Both the model and the experiments show that the ratio of enthalpy change through the evaporator with to without the oil presence increases when the apparent superheat at the evaporator outlet increases. This is due to the presence of a non-evaporated amount of liquid refrigerant dissolved in the oil at this location, which is confirmed by visual observations. The numerical and experimental results are found to be in a good agreement as the maximum deviation is about 2.2%. 相似文献
5.
V.P. Zhelezny V.V. Sechenyh Yu.V. Semenyuk A.J. Grebenkov O.V. Beliayeva 《International Journal of Refrigeration》2009,32(6):1389-1395
This paper presents experimental data for the viscosity of solutions of refrigerant R600a (isobutane) with mineral compressor oils Azmol, Reniso WF 15A, and R245fa (1,1,1,3,3-pentafluoropropane) with polyolester compressor oil Planetelf ACD 100 FY on the saturation line. The experimental data were obtained for solution of R600a with mineral compressor oil Azmol in the temperature range from 294.7 to 338.1 K and the concentration range 0.04399 ≤ wR ≤ 0.3651, the solution of R600a with mineral compressor oil Reniso WF 15A at the temperatures from 285.8 to 348.4 K and the concentration range 0.03364 ≤ wR ≤ 0.2911, the solution of R245fa with polyolester compressor oil Planetelf ACD 100 FY at the temperatures from 309 to 348.2 and the concentration range 0.06390 ≤ wR ≤ 0.3845. The viscosity was measured using a rolling ball method. The method for prediction of the dynamic viscosity for refrigerant/oil solutions is reported. 相似文献
6.
A comparison of the refrigerants HFC 134a and CFC 12 has been carried out and the results from a theoretical analysis and from tests with an open piston compressor are reported in this paper. The results indicate that the tested compressor will give a greater refrigerating capacity with HFC 134a than with CFC 12 for certain operating conditions. However, the results also indicate an increased operating power for the compressor over the entire temperature range. As a result the coefficient of performance is decreased. Another noticeable result is dependency of the compressor's isentropic efficiency on temperature when using HFC 134a. This might be explained by the properties of the polyalkene glycol oil which is used with HFC 134a. The increased cost of using HFC 134a is justified if the environmental aspects are considered and the practical problems, such as the influence on the material in the refrigeration cycle, can be solved. 相似文献
7.
H. O. Spauschus 《International Journal of Refrigeration》1988,11(6):389-392
In response to international protocol agreements and national regulatory actions promoted by the increasing concern for ozone depletion and the greenhouse effect, HFC 134a has emerged as a leading candidate for CFC 12 substitution in automotive air conditioners, centrifugal chillers and residential refrigerators and freezers. This Paper discusses compressor and refrigeration system requirements and information gaps for HFC 134a application as a CFC 12 substitute. 相似文献
8.
Experimental study of the refrigeration cycle performance for the R744/R290 mixtures 总被引:2,自引:1,他引:2
A new binary mixture of R744 and R290 as an alternative natural refrigerant to R13 was first presented in this paper. Its environmental performance is friendly. It has an ODP of zero and GWP smaller than 20. Experimental studies for this mixture and R13 were performed on a cascade refrigeration system only with modification to capillary in low-temperature circuit. COP and refrigeration capacity of this binary mixture were higher than those of R13, at the same time, condensing pressure, evaporating pressure, compression ratio, and discharge temperature were also higher than that of R13 when the high-temperature circuit of cascade refrigeration system was kept invariable. The new binary mixture of R744 and R290 is considered as a promising alternative refrigerant to R13 when the evaporator temperature is higher than 201 K. 相似文献
9.
The surface tensions of R290, R600a and R290/R600a mixture have been measured by the modified differential capillary-rise method. Twenty-two data points for R290 and 21 data points for R600a were obtained in the temperature range between 273 K and 354 K, and 43 data points for R290/R600a mixture on three isotherms of 278 K, 300 K and 320 K were obtained. The experimental uncertainties of temperature and surface tension are estimated to be within 20 mK and 0.2 mN m−1, respectively. Surface tension correlations as a function of temperature for pure R290 and R600a were formulated in the temperature range between 253 K and critical temperature, and the correlation as a function of the composition for R290/R600a mixture was discussed at 278 K, 300 K and 320 K. It is found that the surface tension for R290/R600a mixture can be reproduced by the simple mixing rule by mole fraction with the correlations of both pure components. 相似文献
10.
Effect of refrigerant oil additive on R134a and R123 boiling heat transfer performance 总被引:1,自引:0,他引:1
This paper investigates the effect that an additive had on the boiling performance of an R134a/polyolester lubricant (POE) mixture and an R123/naphthenic mineral oil mixture on a roughened, horizontal flat surface. Both pool boiling heat transfer data and lubricant excess surface density data are given for the R134a/POE (98% mass fraction/2% mass fraction) mixture before and after use of the additive. A spectrofluorometer was used to measure the lubricant excess density that was established by the boiling of the R134a/POE lubricant mixture before and after use of the additive. The measurements obtained from the spectrofluorometer suggest that the additive increases the total mass of lubricant on the boiling surface. The heat transfer data show that the additive caused an average and a maximum enhancement of the R134a/POE heat flux between 5 kW m−2 and 22 kW m−2 of approximately 73% and 95%, respectively. Conversely, for nearly the same heat flux range, the additive caused essentially no change in the pool boiling heat flux of an R123/mineral oil mixture. The lubricant excess surface density and interfacial surface tension measurements of this study were used to form the basis of a hypothesis for predicting when additives will enhance or degrade refrigerant/lubricant pool boiling. 相似文献
11.
Experimental transient performance of a heat pump equipped with a distillation column 总被引:1,自引:0,他引:1
James G. Gebbie Michael K. Jensen Piotr A. Domanski 《International Journal of Refrigeration》2007,30(3):499-505
A series of experiments were conducted on a heat pump equipped with a distillation column. The system was operated with R32 and with a 30/70% by mass mixture of R32/134a to examine the difference between the transient performance trends with a pure fluid (R32), and those with a zeotropic mixture (R32/134a). Additionally, the effects of varying heat transfer fluid mass flow, compressor speed, and accumulator sump heat input were examined. Each test was 1 h in duration. The heat pump capacities did not generally achieve steady state during the R32/134a tests. Steady state was generally achieved during the R32 tests. As a percentage of the final (end-of-test) capacity, the rate of capacity increase was greater during the R32/134a tests than during those conducted with the pure fluid. The R32/134a tests exhibited capacity oscillations early in each transient that were not present during the R32 tests. The results show that circulating refrigerant mass and composition are the primary controlling factors with regard to transient capacity. 相似文献
12.
The experimental investigation of the performance of a vapour ejector refrigeration system is described. The system uses R134a as working fluid and has a rated cooling capacity of 0.5 kW. The influence of generator, evaporator and condenser temperatures on the system performance is studied. This kind of system can be operated with low grade thermal energy such as solar energy, waste heat, etc. The operating conditions are chosen accordingly as, generator temperature between 338 K and 363 K, condenser temperature between 299 K and 310.5 K, and evaporator temperature between 275 K and 285.5 K. Six configurations of ejectors of different geometrical dimensions are selected for the parametric study. The performance of the refrigeration system at different operating temperatures is presented. 相似文献
13.
Hossein Eslami Nargess Mehdipour Ali Boushehri 《International Journal of Refrigeration》2006,29(1):150-154
We have extended our previous work on the equation of state for refrigerants to their mixtures successfully. The temperature-dependent parameters of the equation of state have been calculated using our previous corresponding-states correlation based on the normal boiling point temperature and the liquid density at the normal boiling point. We have applied a simple combining rule for the normal boiling point constants to extend our previously proposed equation of state to mixtures of refrigerants. In this work the liquid densities of a large number of refrigerant mixtures have been calculated and the results are compared both with experimental data and a recent correlation by Nasrifar et al. (1999). The agreement is good. 相似文献
14.
Moiss A. Marcelino Neto Jader R. Barbosa Jr. 《International Journal of Refrigeration》2008,31(1):34-44
Experimental data on solubility, liquid phase density and viscosity of a mixture of R-600a and a POE ISO 7 lubricant oil are presented. A specially designed experimental facility for simultaneous measurements of the physical properties was used in the experiments at temperatures ranging from 10 to 60 °C. The VLE data were correlated with the Heil–Prausnitz and Flory–Huggins activity models and the Peng–Robinson equation of state (EoS). Liquid density was correlated with the Peng–Robinson EoS and with a first-order Redlich–Kister expansion for the excess molar volume. Liquid viscosity was correlated with an excess-property approach based on the classical Eyring liquid viscosity model. Satisfactory agreement was obtained between models and experiments; maximum root mean square (RMS) deviations of models used in the VLE, density and viscosity predictions were 1.1% (VLE EoS), 0.2% (Redlich–Kister) and 3.0% (Grunberg–Nissan), respectively. 相似文献
15.
Detailed 2D CFD calculations for vapour flow field and rate of condensation are carried out for a geometry similar to a real shell-and-tube condenser with 100 tubes, with condensation on the shell-side. The differences in vapour flow behaviour are investigated for pure R22 and for a binary mixture of R32 and R134a, which has a gliding temperature difference of 5.5 K. It is shown that, the flow field for a zeotropic mixture is significantly different from that for a pure fluid. The nature of the mixture flow causes the vapour and condensate to flow counter-currently in part of the condenser. Adjustments of the inlet design turn out to influence the rate of heat transfer by up to 24% for the conditions tested, with greater influence on heat transfer for lower driving forces. 相似文献
16.
This paper presents pool boiling heat transfer data for 12 different R134a/lubricant mixtures and pure R134a on a Turbo-BII™-HP surface. The mixtures were designed to examine the effects of lubricant mass fraction, viscosity, and miscibility on the heat transfer performance of R134a. The magnitude of the effect of each parameter on the heat transfer was quantified with a regression analysis. The mechanistic cause of each effect was given based on new theoretical interpretation and/or one from the literature. The model illustrates that large improvements over pure R134a heat transfer can be obtained for R134a/lubricant mixtures with small lubricant mass fraction, high lubricant viscosity, and a large critical solution temperature (CST). The ratio of the heat flux of the R134a/lubricant mixture to that of the pure R134a for fixed wall superheat was given as a function of pure R134a heat flux for all 12 mixtures. The lubricant that had the largest CST with R134a exhibited the greatest heat transfer: 100%±20% greater than that of pure R134a. By contrast, the heat transfer of the mixture with the lubricant that had the smallest viscosity and the smallest CST with R134a was 55%±9% less than that of pure R134a. High-speed films of the pure and mixture pool boiling were taken to observe the effect of the lubricant on the nucleate boiling. 相似文献
17.
In this study, thermodynamic performance of supplementary/retrofit refrigerant mixtures for CFC12 used in existing automobile air-conditioners was examined. A thermodynamic computer analysis of an automobile air-conditioner was carried out for the initial screening of possible mixture candidates, and refrigerant mixtures composed of HCFC22, HFC134a, HCFC142b, RE170 (dimethylether), HC290 (propane), and HC600a (iso-butane) were proposed to supplement CFC12. Also a breadboard type refrigeration test facility was manufactured to verify the performance of the alternative refrigerant mixtures proposed through the computer analysis. Test results showed that HFC134a/RE170 mixture with zero ozone depletion potential is the best long term candidate to supplement CFC12. On the other hand, HCFC22/HFC134a/RE170 and HCFC22/HFC134a/HCFC142b mixtures are good only as short term supplementary/retrofit alternatives since they contain HCFC22. A hydrocarbon mixture of HC290/HC600a showed a good performance but its use in existing automobile air-conditioners should be carefully considered due to its flammability. 相似文献
18.
Seung Woo Yang Jinhee Jeong Yong Tae Kang 《International Journal of Refrigeration》2008,31(1):130-137
The objectives of this paper are to study the heat transfer characteristics for enhanced surface tubes in the pool boiling and to provide a guideline for the design conditions for the evaporator using HFC134a. The shape of tube surfaces, the wall superheat, and the saturation temperature are considered as the key parameters. Copper tubes (do = 19.05 mm) are treated with different helix angles and the saturation temperatures are controlled from 3 to 16 °C. It is found that the pool boiling heat transfer coefficient decreases with increasing the wall superheat. It is also found that boiling heat transfer coefficients for Turbo-II and Turbo-III are 1.5–3.0 times and 1.2–2.0 times higher than that for Turbo-I without the helix angle, respectively. The higher heat transfer performance from Turbo-II and Turbo-III can be explained by the “bubble detention” phenomenon on the surface without the helix angle for the Turbo-I. The experimental correlations for the pool boiling heat transfer on the present enhanced tubes without (Type I) and with the helix angle (Type II and Type III) are developed with the error bands of ±30%, respectively. 相似文献
19.
Yunho Hwang Dae-Hyun Jin Reinhard Radermacher 《International Journal of Refrigeration》2007,30(4):633-641
To help provide a clear understanding of the relative performance potential of HFCs (R-404A and R-410A) as compared to R-290 for walk-in refrigeration systems representing direct expansion commercial refrigeration systems with small charge, an experimental evaluation of the three refrigerants was investigated. To compare the environmental impact of refrigerants over the entire life cycle of fluid and equipment, including power consumption, the life cycle climate performance (LCCP) of the three refrigerants were evaluated based on measured data. The estimated LCCPs at various emission rates indicate that the LCCP of R-290 is always lower than that of R-404A. The LCCP of R-410A is lower than that of R-290 as long as the annual emission is kept below 10%. It was concluded that R-410A has less or equivalent environmental impact as compared to R-290 when safety (toxicity and flammability), environmental impact (climate change), cost and performance (capacity and COP) are considered. 相似文献
20.
Mitsuhiro Fukuta Tadashi Yanagisawa Masao Shimasaki Yasuhiro Ogi 《International Journal of Refrigeration》2006,29(7):1058-1065
The mixing of refrigeration oil with refrigerant in a refrigeration cycle has great influence on cycle performance. A sampling method is the most general way to measure the mixing ratio of refrigerant and refrigeration oil. Since the sampling method is time-consuming and reduces the amount of refrigerant and oil in the cycle, a real-time measurement is desirable. In this study, a refractive index measurement was applied to measure the mixing ratio of refrigerant/oil mixture. A laser displacement sensor was used to detect any change in optical path which results from changes of the refractive index of refrigerant/oil mixture. For the practical application of real-time measurement of the oil circulation ratio (OCR) in the refrigeration cycle, a correlation between the refractive index and the mixing ratio was developed. In addition, the changes of the refractive index in a range of a few percentages of the oil concentration and under subcooled conditions were measured. Finally, a transient measurement of the OCR in a practically operating refrigeration cycle was carried out successfully. 相似文献