1.
An experimental study was performed to investigate the increment of the pressure drop during condensation of R-134 a vapor inside a horizontal tube with different coiled wire inserts. A double-pipe counter-flow heat exchanger of 1040-mm length was used as the test condenser while, the refrigerant flowed inside the inner tube and the coolant flowed in the annulus. Four coiled wires of 10.0-mm pitch and different diameters of 0.5, 0.7, 1.0 and 1.5-mm and also four springs of 1.0-mm diameter and different pitches of 5, 8, 10 and 13-mm were inserted on the refrigerant side of the test condenser. Data were recorded for different mass flow rates in plain tube and each coiled wire inserted tube. Investigating the results for the coiled wire inserted tubes revealed that inserting the springs increased the pressure drop in a range of 260 to 1600% in comparison with that for a plain tube. Also, influence of coiled wire geometry on the pressure drop was investigated. Based on the collected data, an empirical correlation was developed to predict the pressure drop during the condensation inside a horizontal tube in the presence of a spring insert. Finally, the performance evaluation of the coiled wire inserted condensers was done.  相似文献   

2.
An experimental investigation has been carried out to study heat transfer and pressure drop characteristics of R-134a flow boiling inside a horizontal plain tube and different flattened tubes. Round copper tubes with an inner diameter of 8.7 mm were flattened into an oblong shape with an internal height of 6.6 mm, 5.5 mm, 3.8 mm, and 2.8 mm. The test apparatus was basically a vapor compression refrigeration system equipped with all necessary measuring instruments. Analysis of the collected data showed that, by flattening the round tube, the heat transfer coefficient and pressure drop increased simultaneously. The performance of these tubes from the point of view of heat transfer enhancement and pressure drop increasing were evaluated. It was concluded that, the tube with an internal height of 5.5 mm has the best performance compared with the other flattened tubes. Finally, based on the present experimental pressure drop data, a correlation was developed to estimate the pressure drop in flattened tubes. This correlation predicts the experimental data of the present study within an error band of ± 20%.  相似文献   

3.
An experimental investigation has been carried out to study the enhancement in heat transfer coefficient by coiled wire inserts during heating of engine oil inside a horizontal tube. The test-section was a double-pipe counter-flow heat exchanger. The engine oil flowed inside the internal copper tube, while saturated steam, used for heating the oil, flowed in the annulus. First of all, the data were acquired for the heating of engine oil while flowing in the plain tube. Later, seven coiled wires having pitches of 12–69 mm and wire diameters of 2.0 mm and 3.5 mm were put one by one in the oil-side of test-section. The effects of Reynolds number and coiled wire geometry on the heat transfer augmentation and fanning friction factor were studied. Finally, two empirical correlations have been developed for predicting the heat transfer enhancement of these coiled wire inserts. These correlations predict the experimental Nusselt number in an error band of ±20 percent.  相似文献   

4.
In the present study, the heat transfer characteristics and the pressure drop of the horizontal double pipe with coil-wire insert are investigated. The inner and outer diameters of the inner tube are 8.92 and 9.52 mm, respectively. The coiled wire is fabricated by bending a 1 mm diameter of the iron wire into a coil with a coil diameter of 7.80 mm. Cold and hot water are used as working fluids in the shell side and tube side, respectively. The test runs are performed at the cold and hot water mass flow rates ranging between 0.01 and 0.07 kg/s, and between 0.04 and 0.08 kg/s, respectively. The inlet cold and hot water temperatures are between 15 and 20 °C, and between 40 and 45 °C, respectively. The effect of the coil pitch and relevant parameters on heat transfer characteristics and pressure drop are considered. Coil-wire insert has significant effect on the enhancement of heat transfer especially on laminar flow region. Non-isothermal correlations for the heat transfer coefficient and friction factor are proposed. There is reasonable agreement between the measured data and predicted results.  相似文献   

5.
The heat transfer characteristics and the pressure drop of the horizontal double pipes with and without coiled wire insert are investigated. The inner and outer diameters of the micro-fin tube are 8.92 and 9.52 mm, respectively. The coiled wire is fabricated by bending a 1-mm-diameter iron wire into the coil wire with coil diameter of 7.80 mm. Cold and hot water are used as working fluids in shell side and tube side, respectively. The test runs are performed at the cold and hot water mass flow rates ranging between 0.01 and 0.07 kg/s and between 0.04 and 0.08 kg/s, respectively. The inlet cold and hot water temperatures are between 15 and 20 °C and between 40 and 45 °C, respectively. The results obtained from the micro-fin tube with coiled wire insert are compared with those obtained from the smooth and micro-fin tubes.  相似文献   

6.
The present study investigated the effect of two tube inserts (wire coil and wire mesh) on the heat transfer enhancement, pressure drop and mineral salts fouling mitigation in tube of a heat exchanger. A 3/4-in. tube that is heated by band heaters, is used which simulated a tube of heat exchanger. Working fluid is water with certain quality. The heat transfer rate averagely increased by 22–28% for wire coil (p/d = 0.125, e/d = 0.00375) and 163–174% for wire mesh (medium density) over a plain tube value, depending on type of tube insert, density of wire torsion and flow velocity. However, the pressure drop also increased substantially by 46% for wire coil and 500% for wire mesh. Wire coil insert with vibration mitigate mineral salts fouling (scaling) about 34%, and wire mesh have no effect on scaling, however it sometimes increased deposit rate.  相似文献   

7.
Experimental heat transfer coefficients for R-134a and R-600a in horizontal tubes with vertically positioned perforated strip-type inserts are reported in this paper. Tests were conducted using a single-tube evaporator test facility. The test section used was 2000 mm long, 10.6 mm inside diameter, horizontal, smooth copper tube with perforated strip-type inserts made from the same material (copper). Test parameters were varied as follows: heat flux 9.1-31.2 kW/m2; mass velocity 82.3-603.3 kg/m2 s; quality 0-0.85, and a saturation temperature of 6 °C. The flow pattern were identified for different test tubes and flow conditions. The heat transfer coefficients for R-600a were higher than those for R-134a. The heat transfer performance and pressure drop can be improved up to 2.5 and 1.5, respectively for a 96 perforated holes enhanced tube. All comparisons were based on the same nominal mass flow rate. Finally, an empirical correlation was developed.  相似文献   

8.
Experimental results of heat transfer characteristic and pressure gradients of hydrocarbon refrigerants R-290, R-600a, R-1270 and HCFC refrigerant R-22 during evaporating inside horizontal double pipe heat exchangers are presented. The test sections have one tube diameter of 12.70 mm with 0.86 mm wall thickness, another tube diameter of 9.52 mm with 0.76 mm wall thickness was used for this study. The local evaporating heat transfer coefficients of hydrocarbon refrigerants were higher than those of R-22. The average evaporating heat transfer coefficient increased as the mass flux increased. It is showed the higher values in hydrocarbon refrigerants than R-22. Comparing the heat transfer coefficient of experimental results with that of other correlations, the obtained results from the experiments had coincided with most of the Kandlikar’s correlation. Hydrocarbon refrigerants have higher pressure drop than R-22 in 12.7 mm and 9.52 mm. This results form the study can be used in the case of designing heat transfer exchangers using hydrocarbons as the refrigerant for the air-conditioning systems.  相似文献   

9.
An experimental investigation on heat transfer characteristics of MWCNT-heat transfer oil nanofluid flow inside horizontal flattened tubes has been carried out under uniform wall temperature condition. Nanoparticle weight fractions were 0%, 0.1%, 0.2%, and 0.4%. The copper tubes of 14.5 mm I.D. were flattened and used as the test section of oblong shape with inside heights of 13.4 mm, 11.7 mm, 10.6 mm, and 8.6 mm. The nanofluid flowing inside the tube was heated inside a steam chamber to keep the temperature of the tube wall constant. The required data were acquired for laminar hydrodynamically fully developed regime. The effects of different parameters such as volumetric flow rate, nanoparticle weight fraction, and hydraulic diameter on the heat transfer behavior of the tested systems have been investigated experimentally. For a given flattened tube at a constant nanoparticle weight fraction, increasing volumetric flow rate results in heat transfer enhancement. In addition, as the tube profile becomes more flattened and the hydraulic diameter decreases, the heat transfer coefficient goes up at constant volumetric flow rate. Utilizing nanofluids instead of the base fluid, the heat transfer rate enhances remarkably. The higher the nanoparticles weight fraction, the more the rate of heat transfer enhancement. Finally, the results show that the amount of increase in heat transfer coefficient caused by employing nanofluid instead of the base fluid is comparable to what caused by flattening the tube.  相似文献   

10.
An investigation on flow boiling heat transfer and pressure drop of HFC-134a inside a vertical helically coiled concentric tube-in-tube heat exchanger has been experimentally carried out. The test section is a six-turn helically coiled tube with 5.786-m length, in which refrigerant HFC-134a flowing inside the inner tube is heated by the water flowing in the annulus. The diameter and the pitch of the coil are 305 mm and 45 mm, respectively. The outer diameter of the inner tube and its thickness are respectively 9.52 and 0.62 mm. The inner diameter of the outer tube is 29 mm. The average vapor qualities in test section were varied from 0.1 to 0.8. The tests were conducted with three different mass velocities of 112, 132, and 152 kg/m2-s. Analysis of obtained data showed that increasing of both the vapor qualities and the mass fluxes leads to higher heat transfer coefficients and pressure drops. Also, it was observed that the heat transfer coefficient is enhanced and also the pressure drop is increased when a helically coiled tube is used instead of a straight tube. Based on the present experimental results, a correlation was developed to predict the flow boiling heat transfer coefficient in vertical helically coiled tubes.  相似文献   

11.
Experiments have been performed to investigate the effect of coiled spring inserts on heat transfer, pressure drop, and performance parameters of a triple tube heat exchanger (TTHX). Three different spring inserts having a pitch of 5, 10, and 15 mm are used and the diameter of the spring wire is taken as 1 mm. The experiments were carried out under a turbulent flow regime, with water as a working medium in parallel and counter flow configurations. The variation in different performance characteristics like heat transfer coefficient, Nusselt number, and effectiveness have been compared at various Reynolds numbers ranging between 4000 and 16,000 in the considered flow patterns. The Nusselt number of TTHX with the lowest pitch spring is found to be higher than that of the plain TTHX by 57.27% at Re = 4000 for the counter flow configuration. Both the thermal performance factor and effectiveness increased as the pitch of the spring insert was decreased. The effectiveness of TTHX with the lowest pitch spring insert is found higher than that of the plain TTHX by 43.84% in the counter flow pattern.  相似文献   

12.
An experimental investigation has been carried out to study the heat transfer and pressure drop characteristics of nanofluid flow inside horizontal flattened tubes under constant heat flux. The nanofluid is prepared by dispersion of CuO nanoparticle in base oil and stabilized by means of an ultrasonic device. Nanofluids with different particle weight concentrations of 0.2%, 0.5%, 1% and 2% are used. Copper tubes of 11.5 mm I.D. are flattened into oblong shapes and used as test sections. The nanofluid flowing inside the tube is heated by an electrical heating coil wrapped around it. Required data are acquired for laminar and hydrodynamically fully developed flow inside round and flattened tubes.The effect of different parameters such as flow Reynolds number, flattened tube internal height and nanofluid particle concentration on heat transfer coefficient and pressure drop of the flow is studied. Observations show that the heat transfer performance is improved as the tube profile is flattened. Flattening the tube profile resulted in pressure drop increasing. In addition, the heat transfer coefficient as well as pressure drop is increased by using nanofluid instead of base fluid. Furthermore, the performance evaluation of the two enhanced heat transfer techniques studied in this investigation shows that applying flattened tubes instead of the round tube is a more effective way to enhance the convective heat transfer coefficient compared to the second method which is using nanofluids instead of the base liquid.  相似文献   

13.
In the present study, the heat transfer characteristics and the pressure drop of the horizontal concentric tube with twisted wires brush inserts are investigated. The inner diameters of the inner and outer tubes are 15.78 and 25.40 mm, respectively. The twisted wire brushes are fabricated by winding a 0.2 mm diameter of the copper wires over a 2 mm diameter of two twisted iron core-rod with three different twisted wires densities of 100, 200, 300 wires per centimeter. The plain tube with full-length twisted wires brush and regularly spaced twisted wires brush with 30 cm spacer length inserts are tested. Cold and hot water are used as working fluids in shell side and tube-side, respectively. The test runs are performed at the hot water Reynolds number ranging between 6000 and 20000. The inlet cold and hot water temperatures are 15, 20 °C, and between 40 and 50 °C, respectively. Effect of twisted wires density, inlet fluid temperature, and relevant parameters on heat transfer characteristics and pressure drop are considered. Twisted wire brushes insert have a large effect on the enhancement of heat transfer, however, the pressure drops also increase.  相似文献   

14.
The boiling heat transfer of refrigerant R-134a flow in horizontal small-diameter tubes with inner diameter of 0.51, 1.12, and 3.1 mm was experimentally investigated. Local heat transfer coefficient and pressure drop were measured for a heat flux ranging from 5 to 39 kW/m2, mass flux from 150 to 450 kg/m2 s, evaporating temperature from 278.15 to 288.15 K, and inlet vapor quality from 0 to 0.2. Flow patterns were observed by using a high-speed video camera through a sight glass at the entrance of an evaporator. Results showed that with decreasing tube diameter, the local heat transfer coefficient starts decreasing at lower vapor quality. Although the effect of mass flux on the local heat transfer coefficient decreased with decreasing tube diameter, the effect of heat flux was strong in all three tubes. The measured pressure drop for the 3.1-mm-ID tube agreed well with that predicted by the Lockhart–Martinelli correlation, but when the inner tube diameter was 0.51 mm, the measured pressure drop agreed well with that predicted by the homogenous pressure drop model. With decreasing tube diameter, the flow inside a tube approached homogeneous flow. The contribution of forced convective evaporation to the boiling heat transfer decreases with decreasing the inner tube diameter.  相似文献   

15.
A comprehensive experimental investigation is conducted on the augmentation of heat transfer coefficients and pressure drop during condensation of HFC-134a in a horizontal tube at the presence of different twisted tape inserts. The test section is a 1.04 m long double-tube counter-flow heat exchanger. The refrigerant flows in the inner copper and the cooling water flows in annulus. The experiments are performed for a plain tube and four tubes with twisted tapes inserts of 6, 9, 12 and 15 twist ratios. The pressure drop is directly measured by a differential pressure transducer. It is found that the twisted tape with twist ratio of 6 gives the highest enhancement in the heat transfer coefficient and the maximum pressure drop compared to the plain tube on a nominal area basis. For this case the enhancement in heat transfer and the pressure drop are increased by 40 and 240% in comparison with to the plain tube. It is observed that the twisted tape with the twist ratio of 9 has the best performance enhancing the heat transfer with the minimum pressure drop. Also empirical correlations are developed to predict smooth tube and swirl flow pressure drop. Predicted results are compared to experimental data and it is found that these correlations are reliable for pressure drop estimation.  相似文献   

16.
New correlations of the two-phase multiplier and heat transfer coefficient of R134a during evaporation in a multiport minichannel at low mass flux are proposed. The experimental results were obtained from a test using a counter-flow tube-in-tube heat exchanger with refrigerant flowing in the inner tube and hot water in the gap between the outer and inner tubes. Test section is composed of the extruded multiport aluminium inner tube with an internal hydraulic diameter of 1.2 mm and an acrylic outer tube with an internal hydraulic diameter of 25.4 mm. The experiments were performed at heat fluxes between 10 and 35 kW/m2, and a refrigerant mass flux between 45 and 155 kg/(m2 s). Some physical parameters that influenced the frictional pressure drop and heat transfer coefficient are examined and discussed in detail. The pressure drop and heat transfer coefficient results are also compared with existing correlations. Finally, new correlations for predicting the frictional pressure drop and heat transfer coefficient at low mass fluxes are proposed.  相似文献   

17.
This study investigated the direct relationship between the measured condensation pressure drop and convective heat transfer coefficient of R134a flowing downward inside a vertical smooth copper tube having an inner diameter of 8.1 mm and a length of 500 mm during annular flow. R134a and water were used as working fluids on the tube side and annular side of a double tube heat exchanger, respectively. Condensation experiments were performed at mass fluxes of 260, 300, 340, 400, 456 and 515 kg m−2 s−1 in the high mass flux region of R134a. The condensing temperatures were around 40 and 50 °C; the heat fluxes were between 10.16 and 66.61 kW m−2. Paliwoda’s analysis, which focused mainly on the determination of the two-phase flow factor and two-phase length of evaporators and condensers, was adapted to the in-tube condensation phenomena in the test section to determine the condensation heat transfer coefficient, heat flux, two-phase length and pressure drop experimentally by means of a large number of data points obtained under various experimental conditions.  相似文献   

18.
The two-phase heat transfer coefficient and pressure drop of pure HFC-134a condensing inside a smooth helically coiled concentric tube-in-tube heat exchanger are experimentally investigated. The test section is a 5.786 m long helically coiled double tube with refrigerant flowing in the inner tube and cooling water flowing in the annulus. The inner tube is made from smooth copper tubing of 9.52 mm outer diameter and 8.3 mm inner diameter. The outer tube is made from smooth copper tubing of 23.2 mm outer diameter and 21.2 mm inner diameter. The heat exchanger is fabricated by bending a straight copper double-concentric tube into a helical coil of six turns. The diameter of coil is 305 mm. The pitch of coil is 35 mm. The test runs are done at average saturation condensing temperatures ranging between 40 and 50 °C. The mass fluxes are between 400 and 800 kg m−2 s−1 and the heat fluxes are between 5 and 10 kW m−2. The pressure drop across the test section is directly measured by a differential pressure transducer. The quality of the refrigerant in the test section is calculated using the temperature and pressure obtained from the experiment. The average heat transfer coefficient of the refrigerant is determined by applying an energy balance based on the energy rejected from the test section. The effects of heat flux, mass flux and, condensation temperature on the heat transfer coefficients and pressure drop are also discussed. It is found that the percentage increase of the average heat transfer coefficient and the pressure drop of the helically coiled concentric tube-in-tube heat exchanger, compared with that of the straight tube-in-tube heat exchanger, are in the range of 33–53% and 29–46%, respectively. New correlations for the condensation heat transfer coefficient and pressure drop are proposed for practical applications.  相似文献   

19.
In the present study, the heat transfer performance and friction factor characteristics in a circular tube fitted with twisted wire brush inserts were investigated experimentally. The twisted wire brush inserts were fabricated with four different twisted wire densities of 100, 150, 200, and 250 wires per centimeter by winding a 1 mm diameter of the copper wire over a 5 mm diameter of two twisted iron core-rods. Heat transfer and friction factor data in tubes were examined for Reynolds number ranging from 7,200 to 50,200. The results indicated that the presence of twisted wire brush inserts led to a large effect on the enhancement of heat transfer with corresponding increase in friction factor over the plain tube. The Nusselt number and friction factor of using the twisted wire brush inserts were found to be increased up to 2.15 and 2.0 times, respectively, than those over the plain tube values. Furthermore, the heat transfer performance was evaluated to assess the real benefits of using those type of inserts and the performance was achieved 1.85 times higher compared to the plain tube based on the constant blower power. Finally, correlations were developed based on the data generated from this work to predict the heat transfer, friction factor, and thermal performance factor for turbulent flow through a circular tube fitted with the twisted wire brush inserts in terms of wire density (y), Reynolds number (Re), and Prandtl number (Pr).  相似文献   

20.
The heat transfer characteristics and the pressure drop in the horizontal double pipes with twisted tape insert are investigated. Two test sections with different relative pitches are tested. The inner and outer diameters of the inner tube are 8.10 and 9.54 mm, respectively. The twisted tape is made from the aluminium strip with thickness of 1 mm and the length of 2000 mm. Cold and hot water are used as working fluids in shell side and tube side, respectively. The test runs are done at the cold and hot water mass flow rates ranging between 0.01 and 0.07 kg/s, and between 0.04 and 0.08 kg/s, respectively. The inlet cold and hot water temperatures are between 15 and 20 °C, and between 40 and 45 °C, respectively. The results obtained from the tube with twisted insert are compared with those without twisted tape. Non-isothermal correlations based on the data gathered during this work for predicting the heat transfer coefficient and friction factor of the horizontal pipe with twisted taped insert are proposed. The majority of the data falls within ± 15%, ± 10% of the proposed correlations for heat transfer coefficient and friction factor, respectively.  相似文献   