首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Liu BH  Chang DB 《Ultramicroscopy》2011,111(5):337-341
We proposed and demonstrated a flexible and effective method to design and fabricate scanning probes for atomic force microscopy applications. Computer simulations were adopted to evaluate design specifications and desired performance of atomic force microscope (AFM) probes; the fabrication processes were guided by feedback from simulation results. Through design-simulation-fabrication iterations, tipless cantilevers and tapping mode probes were successfully made with errors as low as 2% in designed resonant frequencies. For tapping mode probes, the probe tip apex achieved a 10 nm radius of curvature without additional sharpening steps; tilt-compensated probes were also fabricated for better scanning performance. This method provides AFM users improved probe quality and practical guidelines for customized probes, which can support the development of novel scanning probe microscopy (SPM) applications.  相似文献   

2.
Haochih Liu B  Chen CH 《Ultramicroscopy》2011,111(8):1124-1130
The in-use wear of atomic force microscopy (AFM) probe tips is crucial for the reliability of AFM measurements. Increase of tip size for several nanometers is difficult to monitor but it can already taint subsequent AFM data. We have developed a method to study the shape evolution of AFM probe tips in nanometer scale. This approach provides direct comparison of probe shape profiles, and thus can help in evaluation of the level of tip damage and quality of acquired AFM data. Consequently, the shape degradation of probes modified by hydrophobic alkylsilane self-assembled monolayers (SAMs) was studied. The tip wear length and wear volume were adopted to quantitatively verify the effectiveness of hydrophobic coatings. When compared with their silicon counterparts, probes modified by SAM materials exhibit superior wear-resistant behavior in tapping mode scans.  相似文献   

3.
Huang L  Su C 《Ultramicroscopy》2004,100(3-4):277-285
Changing the method of tip/sample interaction leads to contact, tapping and other dynamic imaging modes in atomic force microscopy (AFM) feedback controls. A common characteristic of these feedback controls is that the primary control signals are based on flexural deflection of the cantilever probes, statically or dynamically. We introduce a new AFM mode using the torsional resonance amplitude (or phase) to control the feedback loop and maintain the tip/surface relative position through lateral interaction. The torsional resonance mode (TRmode™) provides complementary information to tapping mode for surface imaging and studies. The nature of tip/surface interaction of the TRmode facilitates phase measurements to resolve the in-plane anisotropy of materials as well as measurements of dynamic friction at nanometer scale. TRmode can image surfaces interleaved with TappingMode™ with the same probe and in the same area. In this way we are able to probe samples dynamically in both vertical and lateral dimensions with high sensitivity to local mechanical and tribological properties. The benefit of TRmode has been proven in studies of water adsorption on HOPG surface steps. TR phase data yields approximately 20 times stronger contrast than tapping phase at step edges, revealing detailed structures that cannot be resolved in tapping mode imaging. The effect of sample rotation relative to the torsional oscillation axis of the cantilever on TR phase contrast has been observed. Tip wear studies of TRmode demonstrated that the interaction forces between tip and sample could be controlled for minimum tip damage by the feedback loop.  相似文献   

4.
Carbon nanotube (CNT) tips in tapping mode atomic force microscopy (AFM) enable very high-resolution imaging, measurements, and manipulation at the nanoscale. We present recent results based on experimental analysis that yield new insights into the dynamics of CNT probe tips in tapping mode AFM. Experimental measurements are presented of the frequency response and dynamic amplitude-distance data of a high-aspect-ratio multi-walled (MW) CNT tip. Higher harmonics of the microcantilever are measured in frequency ranges corresponding to attractive regime and the repulsive regime where the CNT buckles dynamically. Surface scanning is performed using a MWCNT tip on a SiO(2) grating to verify the imaging instabilities associated with MWCNT buckling when used with normal control schemes in the tapping mode. Lastly, the choice of optimal setpoints for tapping mode control using CNT tip are discussed using the experimental results.  相似文献   

5.
Gibson CT  Carnally S  Roberts CJ 《Ultramicroscopy》2007,107(10-11):1118-1122
In atomic force microscopy (AFM) the accuracy of data is often limited by the tip geometry and the effect on this geometry of wear. One way to improve the tip geometry is to attach carbon nanotubes (CNT) to AFM tips. CNTs are ideal because they have a small diameter (typically between 1 and 20nm), high aspect ratio, high strength, good conductivity, and almost no wear. A number of methods for CNT attachment have been proposed and explored including chemical vapour deposition (CVD), dielectrophoresis, arc discharge and mechanical attachment. In this work we will use CVD to deposit nanotubes onto a silicon surface and then investigate improved methods to pick-up and attach CNTs to tapping mode probes. Conventional pick-up methods involve using standard tapping mode or non-contact mode so as to attach only those CNTs that are aligned vertically on the surface. We have developed improved methods to attach CNTs using contact mode and reduced set-point tapping mode imaging. Using these techniques the AFM tip is in contact with a greater number of CNTs and the rate and stability of CNT pick-up is improved. The presence of CNTs on the modified AFM tips was confirmed by high-resolution AFM imaging, analysis of the tips dynamic force curves and scanning electron microscopy (SEM).  相似文献   

6.
Transient dynamics of tapping mode atomic force microscope (AFM) for critical dimension measurement are analyzed. A simplified nonlinear model of AFM is presented to describe the forced vibration of the micro cantilever-tip system with consideration of both contact and non-contact transient behavior for critical dimension measurement. The governing motion equations of the AFM cantilever system are derived from the developed model. Based on the established dynamic model, motion state of the AFM cantilever system is calculated utilizing the method of averaging with the form of slow flow equations. Further analytical solutions are obtained to reveal the effects of critical parameters on the system dynamic performance. In addition, features of dynamic response of tapping mode AFM in critical dimension measurement are studied, where the effects of equivalent contact stiffness, quality factor and resonance frequency of cantilever on the system dynamic behavior are investigated. Contact behavior between the tip and sample is also analyzed and the frequency drift in contact phase is further explored. Influence of the interaction between the tip and sample on the subsequent non-contact phase is studied with regard to different parameters. The dependence of the minimum amplitude of tip displacement and maximum phase difference on the equivalent contact stiffness, quality factor and resonance frequency are investigated. This study brings further insights into the dynamic characteristics of tapping mode AFM for critical dimension measurement, and thus provides guidelines for the high fidelity tapping mode AFM scanning.  相似文献   

7.
This article summarizes improvements to the speed, simplicity and versatility of tapping mode atomic force microscopy (AFM). Improvements are enabled by a piezoelectric microcantilever with a sharp silicon tip and a thin, low-stress zinc oxide (ZnO) film to both actuate and sense deflection. First, we demonstrate self-sensing tapping mode without laser detection. Similar previous work has been limited by unoptimized probe tips, cantilever thicknesses, and stress in the piezoelectric films. Tests indicate self-sensing amplitude resolution is as good or better than optical detection, with double the sensitivity, using the same type of cantilever. Second, we demonstrate self-oscillating tapping mode AFM. The cantilever's integrated piezoelectric film serves as the frequency-determining component of an oscillator circuit. The circuit oscillates the cantilever near its resonant frequency by applying positive feedback to the film. We present images and force-distance curves using both self-sensing and self-oscillating techniques. Finally, high-speed tapping mode imaging in liquid, where electric components of the cantilever require insulation, is demonstrated. Three cantilever coating schemes are tested. The insulated microactuator is used to simultaneously vibrate and actuate the cantilever over topographical features. Preliminary images in water and saline are presented, including one taken at 75.5 μm/s—a threefold improvement in bandwidth versus conventional piezotube actuators.  相似文献   

8.
We introduce a method that exploits the “active” nature of the force-sensing integrated readout and active tip (FIRAT), a recently introduced atomic force microscopy (AFM) probe, to control the interaction forces during individual tapping events in tapping mode (TM) AFM. In this method the probe tip is actively retracted if the tip–sample interaction force exceeds a user-specified force threshold during a single tap while the tip is still in contact with the surface. The active tip control (ATC) circuitry designed for this method makes it possible to control the repulsive forces and indentation into soft samples, limiting the repulsive forces during the scan while avoiding instability due to attractive forces. We demonstrate the accurate topographical imaging capability of this method on suitable samples that possess both soft and stiff features.  相似文献   

9.
A modified tapping mode of the atomic force microscope (AFM) was introduced for manipulation, dissection, and lithography. By sufficiently decreasing the amplitude of AFM tip in the normal tapping mode and adjusting the setpoint, the tip-sample interaction can be efficiently controlled. This modified tapping mode has some characteristics of the AFM contact mode and can be used to manipulate nanoparticles, dissect biomolecules, and make lithographs on various surfaces. This method did not need any additional equipment and it can be applied to any AFM system.  相似文献   

10.
While image quality from instruments such as electron microscopes, light microscopes, and confocal laser scanning microscopes is mostly influenced by the alignment of optical train components, the atomic force microscope differs in that image quality is highly dependent upon a consumable component, the scanning probe. Although many types of scanning probes are commercially available, specific configurations and styles are generally recommended for specific applications. For instance, in our area of interest, tapping mode imaging of biological constituents in fluid, double ended, oxide-sharpened pyramidal silicon nitride probes are most often employed. These cantilevers contain four differently sized probes; thick- and thin-legged 100 microm long and thick- and thin-legged 200 microm long, with only one probe used per cantilever. In a recent investigation [Taatjes et al. (1997) Cell Biol. Int. 21:715-726], we used the scanning electron microscope to modify the oxide-sharpened pyramidal probe by creating an electron beam deposited tip with a higher aspect ratio than unmodified tips. Placing the probes in the scanning electron microscope for modification prompted us to begin to examine the probes for defects both before and after use with the atomic force microscope. The most frequently encountered defect was a mis-centered probe, or a probe hanging off the end of the cantilever. If we had difficulty imaging with a probe, we would examine the probe in the scanning electron microscope to determine if any defects were present, or if the tip had become contaminated during scanning. Moreover, we observed that electron beam deposited tips were blunted by the act of scanning a hard specimen, such as colloidal gold with the atomic force microscope. We also present a mathematical geometric model for deducing the interaction between an electron beam deposited tip and either a spherical or elliptical specimen. Examination of probes in the scanning electron microscope may assist in interpreting images generated by the atomic force microscope.  相似文献   

11.
Atomic force microscopy (AFM) was used to study the morphology and surface properties of NR/NBR blend. Blends at 1/3, 1/1 and 3/1 weight ratios were prepared in benzene and formed film by casting. AFM phase images of these blends in tapping mode displayed islands in the sea morphology or matrix-dispersed structures. For blend 1/3, NR formed dispersed phase while in blends 1/1 and 3/1 phase inversion was observed. NR showed higher phase shift angle in AFM phase imaging for all blends. This circumstance was governed by adhesion energy hysteresis between the device tip and the rubber surface rather than surface stiffness of the materials, as proved by force distance measurements in the AFM contact mode.  相似文献   

12.
This paper presents a simple and reliable technique for nanometer-scale layer modification of a polycarbonate (PC) surface using an atomic force microscope (AFM). The AFM tip, coated with amorphous carbon was made to oscillate vertically at its resonance frequency. With tip oscillating in tapping mode, it scan-scratched the PC surface to make the desired modification. This action carved the PC surface without distorting it. The bottom of the depression made by scan-scratching with the oscillating tip was obviously flat in comparison with the area scan-scratched without tip oscillation in contact mode. The depth of the scan-scratched depression was controlled by adjusting the amplitude of oscillation and the scanning speed of scratching. This technique is very interesting for microtribology and surface modification.  相似文献   

13.
Iwasiewicz-Wabnig A  Shin JH  Xiao S  Edman L 《Ultramicroscopy》2007,107(10-11):1078-1085
A common method for characterizing the phase separation of materials in mixtures is tapping mode atomic force microscopy (AFM). However, AFM results are influenced by surface-energy effects and the employed tapping force, and it might therefore be difficult to attain correct information regarding the bulk with such a surface-imaging technique. In this work, we present a way of imaging material phase separation in an improved manner by recording a series of AFM images at different tapping force. More specifically, we have employed the variable-force AFM method on organic mixtures, comprising a conjugated polymer (MEH-PPV) and an ion-conducting polymer electrolyte (PEO-XCF(3)SO(3), X=Li, K, Rb), and we demonstrate that it is capable of reversibly sampling such materials not only on the surface, but also (indirectly) in the topmost part of the bulk. The analysis of the evolution of AFM phase images allows us to (indirectly) gain information about the bulk-phase separation of materials. We find that the variable-force AFM results correlate well with the device performance of light-emitting electrochemical cells employing such organic mixtures as the active material.  相似文献   

14.
Tapping mode atomic force microscopy (AFM) provides phase images in addition to height and amplitude images. Although the behavior of tapping mode AFM has been investigated using mathematical modeling, comprehensive understanding of the behavior of tapping mode AFM still poses a significant challenge to the AFM community, involving issues such as the correct interpretation of the phase images. In this paper, the cantilever's dynamic behavior in tapping mode AFM is studied through a three dimensional finite element method. The cantilever's dynamic displacement responses are firstly obtained via simulation under different tip‐sample separations, and for different tip‐sample interaction forces, such as elastic force, adhesion force, viscosity force, and the van der Waals force, which correspond to the cantilever's action upon various different representative computer‐generated test samples. Simulated results show that the dynamic cantilever displacement response can be divided into three zones: a free vibration zone, a transition zone, and a contact vibration zone. Phase trajectory, phase shift, transition time, pseudo stable amplitude, and frequency changes are then analyzed from the dynamic displacement responses that are obtained. Finally, experiments are carried out on a real AFM system to support the findings of the simulations. Microsc. Res. Tech. 78:935–946, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

15.
Development of nanotechnology has given rise to various applications, including the nano‐manipulation process within small‐size environments. The implementation of such processes requires the use of tools and proper equipment and understanding of various factors influencing it. One such tool is the atomic force microscope (AFM) and its probe, used for imaging surfaces and manipulation tools. The AFM probe is the most important element of the AFM with a key role in system function. The dynamic analysis and control of AFM are necessary to increase efficiency. In this paper, a model of AFM is reviewed and rewritten by considering various cantilever probes, including rectangular, V‐shaped, and dagger. The AFM actuator was modeled and analyzed on uncertain conditions. The position of the stage was controlled to the desired position through the desired motion profiles. To overcome the problem of model nonlinearity, a neural network (NN) sliding mode controller was used to optimize the controller parameter and provide the desired output. The simulation of system was performed by the effective parameters, its control was implemented, and the results were analyzed. The simulation revealed that the modified sliding mode controller with learnable NN improved controller performance by decreasing the rise time and eliminating the overshot.  相似文献   

16.
The force sensor of an atomic force microscope (AFM) is sensitive enough to measure single molecular binding strengths by means of a force-distance curve. In order to combine high-force sensitivity with the spatial resolution of an AFM in topography mode, adhesion mode has been developed. Since this mode generates a force-distance curve for every pixel of an image, the measurement speed in liquid is limited by the viscous drag of the cantilever. We have equipped our adhesion mode AFM with a cantilever that has a low viscous drag in order to reach pixel frequencies of 65 Hz. Optimized filtering techniques combined with an auto-zero circuitry that reduces the drift in the deflection signal, limited high- and low-frequency fluctuations in the height signal to 0.3 nm. This reduction of the height noise, in combination with a thermally stabilized AFM, allowed the visualization of individual molecules on mica with an image quality comparable to tapping mode. The lateral resolution in both the topography and the simultaneously recorded adhesion image are only limited by the size of the tip. Hardware and software position feedback systems allows individual molecules to be followed in time during more than 30 min with scan sizes down to 60 x 60 nm2.  相似文献   

17.
Successful imaging of living human cells using atomic force microscopy (AFM) is influenced by many variables including cell culture conditions, cell morphology, surface topography, scan parameters, and cantilever choice. In this study, these variables were investigated while imaging two morphologically distinct human cell lines, namely LL24 (fibroblasts) and NCI H727 (epithelial) cells. The cell types used in this study were found to require different parameter settings to produce images showing the greatest detail. In contact mode, optimal loading forces ranged between 2-2.8 x 10(-9) and 0.1-0.7 x 10(-9) (N) for LL24 and NCI H727 cells respectively. In tapping (AC) mode, images of LL24 cells were obtained using cantilevers with a spring constant of at least 0.32 N/m, while NCI H727 cells required a greater spring constant of at least 0.58 N/m. To obtain tapping mode images, cantilevers needed to be tuned to resonate at higher frequencies than their resonance frequencies to obtain images. For NCI H727 cells, contact mode imaging produced the clearest images. For LL24 cells, contact and tapping mode AFM produced images of comparable quality. Overall, this study shows that cells with different morphologies and surface topography require different scanning approaches and optimal conditions must be determined empirically to achieve images of high quality.  相似文献   

18.
Wu Y  Hu Y  Cai J  Ma S  Wang X  Chen Y 《Scanning》2008,30(5):426-432
Atomic force microscopy (AFM) has been widely applied in cellular morphology study. However, morphological information including volume and roughness obtained by AFM are usually affected by different kinds of factors, which include the microscopic system itself, imaging mode, or external factors such as AFM probe or tip condition. In this study, based on red blood cell model, the dependence of cellular morphology, volume, and roughness on several parameters of the imaging was evaluated and, furthermore, a general rule and resolution for trustful analysis had been suggested. In addition, the potential effects that resulted from sample itself had also been analyzed based on adhesive force analysis. The results indicated that the scanning range and the imaging mode affect cellular volume and roughness, and the distorted images should be ascribed to blunt tip, contaminated tip, and the shape of tip. The analysis of morphological distortion during AFM investigation of cells provides a reference for researchers using AFM.  相似文献   

19.
Active Q control may be used to modify the effective quality (Q) factor of an atomic force microscope (AFM) micro-cantilever when operating in tapping mode. The control system uses velocity feedback to obtain an effective cantilever Q factor to achieve optimal scan speed and image resolution for the imaging environment and sample type. Time delay of the cantilever displacement signal is the most common method of cantilever velocity estimation. Spill-over effects from unmodeled dynamics may degrade the closed loop system performance, possibly resulting in system instability, when time delay velocity estimation is used. A resonant controller is proposed in this work as an alternate method of velocity estimation. This new controller has guaranteed closed loop stability, is easy to tune, and may be fitted into existing commercial AFMs with minimal modification. Images of a calibration grating are obtained using this controller to demonstrate its effectiveness.  相似文献   

20.
This paper presents a technique for groove machining of potassium niobate nanosheets using an atomic force microscope (AFM). Groove machining operations are performed using super sharp silicon (SSS) probes. The tip radius of these probes is less than 5 nm and is one-third that of a conventional silicon (Si) probe. The results obtained using these probes are compared with those obtained using a Si probe, in order to examine the tip radius effects of the AFM probe on groove machining accuracy, i.e., coarseness of the machined groove. These results show that the degree of coarseness of the machined groove for varying machining loads with the SSS probe was much worse than that with the Si probe. Thus, groove machining with the SSS probe was more difficult to control with varying machining loads. We propose a groove fabrication model that considers the stochastic energy and difference in tip radius of the AFM probe. Using our groove fabrication model, changes in the coarseness of the machined groove for varying machining loads can be predicted.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号