首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
For almost a century, the resolution of optical microscopy was thought to be limited by Abbé’s law describing the diffraction limit of light. At the turn of the millennium, aided by new technologies and fluorophores, the field of optical microscopy finally surpassed the diffraction barrier: a milestone achievement that has been recognized by the 2014 Nobel Prize in Chemistry. Many super‐resolution methods rely on the unique photophysical properties of the fluorophores to improve resolution, posing significant limitations on biological imaging, such as multicoloured staining, live‐cell imaging and imaging thick specimens. Structured Illumination Microscopy (SIM) is one branch of super‐resolution microscopy that requires no such special properties of the applied fluorophores, making it more versatile than other techniques. Since its introduction in biological imaging, SIM has proven to be a popular tool in the biologist's arsenal for following biological interaction and probing structures of nanometre scale. SIM continues to see much advancement in design and implementation, including the development of Image Scanning Microscopy (ISM), which uses patterned excitation via either predefined arrays or raster‐scanned single point‐spread functions (PSF). This review aims to give a brief overview of the SIM and ISM processes and subsequent developments in the image reconstruction process. Drawing from this, and incorporating more recent achievements in light shaping (i.e. pattern scanning and super‐resolution beam shaping), this study also intends to suggest potential future directions for this ever‐expanding field.  相似文献   

2.
Many papers have claimed the attainment of super‐resolution, i.e. resolution beyond that achieved classically, by measurement of the profile of a feature in the image. We argue that measurement of the contrast of the image of a dark bar on a bright background does not give a measure of resolution, but of detection sensitivity. The width of a bar that gives an intensity at the center of the bar of 0.735 that in the bright region (the same ratio as in the Rayleigh resolution criterion) is for the coherent case with central illumination. This figure, which compares with for the Abbe resolution limit with central illumination, holds for the classical case, and so is no indication of super‐resolution. Theoretical images for two points, two lines, arrays of lines, arrays of bars, and grating objects are compared. These results can be used a reference for experimental results, to determine if super‐resolution has indeed been attained. The history of the development of the theory of microscope resolution is outlined.  相似文献   

3.
The scanning electron microscope (SEM) is usually operated with a beam voltage, V0, in the range of 10–30 kV, even though many early workers had suggested the use of lower voltages to increase topographic contrast and to reduce specimen charging and beam damage. The chief reason for this contradiction is poor instrumental performance when V0=1–3 kV, The problems include low source brightness, greater defocusing due to chromatic aberration greater sensitivity to stray fields, and difficulty in collecting the secondary electron signal. Responding to the needs of the semiconductor industry, which uses low V0 to reduce beam damage, considerable efforts have been made to overcome these problems. The resulting equipment has greatly improved performance at low kV and substantially removes the practical deterrents to operation in this mode. This paper reviews the advantages of low voltage operation, recent progress in instrumentation and describes a prototype instrument designed and built for optimum performance at 1 kV. Other limitations to high resolution topographic imaging such as surface contamination, the de-localized nature of the inelastic scattering event and radiation damage are also discussed.  相似文献   

4.
We propose a novel imaging method that enables the enhancement of three‐dimensional resolution of confocal microscopy significantly and achieve experimentally a new fluorescence emission difference method for the first time, based on the parallel detection with a detector array. Following the principles of photon reassignment in image scanning microscopy, images captured by the detector array were arranged. And by selecting appropriate reassign patterns, the imaging result with enhanced resolution can be achieved with the method of fluorescence emission difference. Two specific methods are proposed in this paper, showing that the difference between an image scanning microscopy image and a confocal image will achieve an improvement of transverse resolution by approximately 43% compared with that in confocal microscopy, and the axial resolution can also be enhanced by at least 22% experimentally and 35% theoretically. Moreover, the methods presented in this paper can improve the lateral resolution by around 10% than fluorescence emission difference and 15% than Airyscan. The mechanism of our methods is verified by numerical simulations and experimental results, and it has significant potential in biomedical applications.  相似文献   

5.
In order to improve the spatial resolution achieved by magnetic force microscopy (MFM) technique and its derivatives, we employ here advanced MFM tips fabricated by means of focused ion beam (FIB) milling. The magnetic coating applied on these tips is a CoCr film of 10 nm thickness. The MFM measurements on hard disk test samples reveal the achieved high resolution, and the measurement on a garnet film demonstrates the low invasiveness. High-frequency MFM (HF-MFM) is a development of the MFM technique to observe the HF stray fields emerging from magnetic recording writer poles at their operating conditions. By means of HF-MFM, magnetic recording writer poles are characterized in the frequency range 100-1,000 MHz. Up to now, all HF-MFM experiments conducted were using standard MFM cantilevers. From the HF-MFM images obtained using the advanced MFM cantilevers, it is clearly seen that the spatial resolution is considerably improved over the images obtained using standard MFM tips. However, the 10 nm thick magnetic coating of the cantilevers is found to work properly only at frequencies of up to about 500 MHz.  相似文献   

6.
We report an ingenious method of super‐resolution optical microscopy utilizing scannable cantilever‐combined microsphere. By scanning the microsphere over the sample surface in a cantilever‐combined microsphere‐sample contact state, super‐resolution images can be acquired at arbitrary sample regions through near‐field information collection by the microsphere. In addition, such a state can effectively reduce the possibility of breaking the cantilever and damaging the microsphere or sample surface. This work has developed a new method and technique of sub‐diffraction‐limit optical microscopy, and can be practically applied in various fields of micro/nanoscopy. Microsc. Res. Tech. 78:1128–1132, 2015. © 2015 Wiley Periodicals, Inc.  相似文献   

7.
Due to photobleaching and phototoxicity induced by high-intensity excitation light, the number of fluorescence images that can be obtained in live cells is always limited. This limitation becomes particularly prominent in multidimensional recordings when multiple Z-planes are captured at every time point. Here we present a simple technique, termed predictive-focus illumination (PFI), which helps to minimize cells' exposure to light by decreasing the number of Z-planes that need to be captured in live-cell 3D time-lapse recordings. PFI utilizes computer tracking to predict positions of objects of interest (OOIs) and restricts image acquisition to small dynamic Z-regions centred on each OOI. Importantly, PFI does not require hardware modifications and it can be easily implemented on standard wide-field and spinning-disc confocal microscopes.  相似文献   

8.
Three-dimensional (3-D) imaging in confocal microscopes is considered in terms of 3-D transfer functions. This leads to an explanation of axial imaging properties. The axial response was observed in both object-scanning and beam-scanning microscopes and the influence of off-axis examination investigated. By simple processing of multi-detector signals, imaging in both the axial and transverse directions can be improved.  相似文献   

9.
In the femtoliter observation volume of a two-photon microscope, multiple fluorophores can be present and complex photophysics can take place. Combined detection of the fluorescence emission spectra and lifetimes can provide deeper insight into specimen properties than these two imaging modalities taken separately. Therefore, we have developed a detection scheme based on a frequency-modulated multichannel photomultiplier, which measures simultaneously the spectrum and the lifetime of the emitted fluorescence. Experimentally, the efficiency of the frequency domain lifetime measurement was compared to a time domain set-up. The performance of this spectrally and lifetime-resolved microscope was evaluated on reference specimens and living cells labeled with three different stains targeting the membrane, the mitochondria, and the nucleus.  相似文献   

10.
11.
The new high‐sensitive and high‐resolution technique, Re‐scan Confocal Microscopy (RCM), is based on a standard confocal microscope extended with a re‐scan detection unit. The re‐scan unit includes a pair of re‐scanning mirrors that project the emission light onto a camera in a scanning manner. The signal‐to‐noise ratio of Re‐scan Confocal Microscopy is improved by a factor of 4 compared to standard confocal microscopy and the lateral resolution of Re‐scan Confocal Microscopy is 170 nm (compared to 240 nm for diffraction limited resolution, 488 nm excitation, 1.49 NA). Apart from improved sensitivity and resolution, the optical setup of Re‐scan Confocal Microscopy is flexible in its configuration in terms of control of the mirrors, lasers and filters. Because of this flexibility, the Re‐scan Confocal Microscopy can be configured to address specific biological applications. In this paper, we explore a number of possible configurations of Re‐scan Confocal Microscopy for specific biomedical applications such as multicolour, FRET, ratio‐metric (e.g. pH and intracellular Ca2+ measurements) and FRAP imaging.  相似文献   

12.
Differential interference contrast (DIC) microscopy can provide information about subcellular components and organelles inside living cells. Applicability to date, however, has been limited to 2D imaging. Unfortunately, understanding of cellular dynamics is difficult to extract from these single optical sections. We demonstrate here that 3D differential interference contrast microscopy has sub‐diffraction limit resolution both laterally and vertically, and can be used for following Madin Darby canine kidney cell division process in real time. This is made possible by optimization of the microscope optics and by incorporating computer‐controlled vertical scanning of the microscope stage.  相似文献   

13.
We compare the axial sectioning capability of multifocal confocal and multifocal multiphoton microscopy in theory and in experiment, with particular emphasis on the background arising from the cross‐talk between adjacent imaging channels. We demonstrate that a time‐multiplexed non‐linear excitation microscope exhibits significantly less background and therefore a superior axial resolution as compared to a multifocal single‐photon confocal system. The background becomes irrelevant for thin (< 15 µm) and sparse fluorescent samples, in which case the confocal parallelized system exhibits similar or slightly better sectioning behaviour due to its shorter excitation wavelength. Theoretical and experimental axial responses of practically implemented microscopes are given.  相似文献   

14.
Two-photon excitation laser scanning fluorescence microscopy (2p-LSM) was compared with UV-excitation confocal laser scanning fluorescence microscopy (UV-CLSM) in terms of three-dimensional (3-D) calcium imaging of living cells in culture. Indo-1 was used as a calcium indicator. Since the excitation volume is more limited and excitation wavelengths are longer in 2p-LSM than in UV-CLSM, 2p-LSM exhibited several advantages over UV-CLSM: (1) a lower level of background signal by a factor of 6–17, which enhances the contrast by a factor of 6–21; (2) a lower rate of photobleaching by a factor of 2–4; (3) slightly lower phototoxicity. When 3-D images were repeatedly acquired, the calcium concentration determined by UV-CLSM depended strongly on the number of data acquisitions and the nuclear regions falsely exhibited low calcium concentrations, probably due to an interplay of different levels of photobleaching of Indo-1 and autofluorescence, while the calcium concentration evaluated by 2p-LSM was stable and homogeneous throughout the cytoplasm. The spatial resolution of 2p-LSM was worse by 10% in the focal plane and by 30% along the optical axis due to the longer excitation wavelength. This disadvantage can be overcome by the addition of a confocal pinhole (two-photon excitation confocal laser scanning fluorescence microscopy), which made the resolution similar to that in UV-CLSM. These results indicate that 2p-LSM is preferable for repeated 3-D reconstruction of calcium concentration in living cells. In UV-CLSM, 0.18-mW laser power with a 2.φ pinhole (in normalized optical coordinate) gives better signal-to-noise ratio, contrast and resolution than 0.09-mW laser power with a 4.9-φ pinhole. However, since the damage to cells and the rate of photobleaching is substantially greater under the former condition, it is not suitable for repeated acquisition of 3-D images.  相似文献   

15.
The optical properties of a general scanning microscope are determined within the framework of Fourier imaging theory. For a simple model optical system, with Gaussian lens and detector apertures, the contrast transfer function can be expressed in terms of elementary functions. The theory predicts that spatial resolution and depth discrimination vary continuously with detector aperture and that defocus phase contrast is present in transmission images obtained with a symmetric objective, collector lens confocal microscope.  相似文献   

16.
Several new features of mitochondrial nucleoid and its surroundings in mammalian cells were described previously (Pracha?, 2016). Very small details were observed using the improved transmission electron microscopy method, as described in the article. In the meantime, the method has again been improved to 2 Å resolutions in the cell section. The method described in detail in the present work is documented on the same records that were published in lower resolution in the work Pracha? (2016), enabling comparison of the achieved resolution with the previous one. New records are also presented, showing extremely high resolution and thus implying the importance of the method. Potential use of this method in different fields is suggested.  相似文献   

17.
鉴于双光子受激发射损耗(STED)复合显微镜在神经疾病临床诊断及脑科学研究中的重要作用,对双光子STED复合显微成像中多波长选通、多光束合束、关键技术指标等进行了研究,完成了复合显微镜样机系统集成研制和复合成像。该复合显微镜可以对荧光标记的样本进行扫描成像,具备红绿双色荧光扫描成像功能、双光子绿色荧光成像功能和STED超分辨绿色荧光成像功能。测试结果表明,该复合显微镜成像深度达到700 μm,分辨率优于60 nm。  相似文献   

18.
To take full advantage of fast resonant scanning in super‐resolution stimulated emission depletion (STED) microscopy, we have developed an ultrafast photon counting system based on a multigiga sample per second analogue‐to‐digital conversion chip that delivers an unprecedented 450 MHz pixel clock (2.2 ns pixel dwell time in each scan). The system achieves a large field of view (~50 × 50 μm) with fast scanning that reduces photobleaching, and advances the time‐gated continuous wave STED technology to the usage of resonant scanning with hardware‐based time‐gating. The assembled system provides superb signal‐to‐noise ratio and highly linear quantification of light that result in superior image quality. Also, the system design allows great flexibility in processing photon signals to further improve the dynamic range. In conclusion, we have constructed a frontier photon counting image acquisition system with ultrafast readout rate, excellent counting linearity, and with the capacity of realizing resonant‐scanning continuous wave STED microscopy with online time‐gated detection.  相似文献   

19.
Bioluminescence from cells is so dim that bioluminescence microscopy is performed using an ultra low‐light imaging camera. Although the image sensor of such cameras has been greatly improved over time, such improvements have not been made commercially available for microscopes until now. Here, we customized the optical system of a microscope for bioluminescence imaging. As a result, bioluminescence images of cells could be captured with a conventional objective lens and colour imaging camera. As bioluminescence microscopy requires no excitation light, it lacks the photo‐toxicity associated with fluorescence imaging and permits the long‐term, nonlethal observation of living cells. Thus, bioluminescence microscopy would be a powerful tool in cellular biology that complements fluorescence microscopy.  相似文献   

20.
A scanning optical fluorescence microscope is described which possesses several advantages over a conventional fluorescence microscope. These include improved resolution, a reduction in background- and auto-fluorescence, an increase in the available fluorescence spectrum and simple modification for automated fluorescence studies. Experimental results are included.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏