首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 640 毫秒
1.
Isotopic variations of Zn in biological materials   总被引:3,自引:0,他引:3  
Variations in the isotopic composition of Zn present in various biological materials were determined using high-resolution multicollector inductively coupled plasma mass spectrometry (MC-ICPMS), following digestion and purification by anion exchange chromatography. To correct for differences in instrumental mass discrimination effects between samples and standards, Cu was employed as an elemental spike. Complementary analyses of Zn separates by sector field ICPMS instruments revealed that the concentrations of the majority of potentially interfering elements were reduced to negligible levels. Residual spectral interferences resulting from (35)Cl(16)O(2)(+), (40)Ar(14)N(2)(+), and (40)Ar(14)N(16)O(+) could be instrumentally resolved from the (67)Zn, (68)Zn, and (70)Zn ion beams, respectively, during measurement by MC-ICPMS. The only other observed interference in the Cu and Zn mass range that could not be effectively eliminated by high-resolution multicollection resulted from (35)Cl(2)(+), necessitating modification of the sample preparation procedure to allow accurate (70)Zn detection. Complete duplication of the entire analytical procedure for human whole blood and hair, as well as bovine liver and muscle, provided an external reproducibility of 0.05-0.12 per thousand (2sigma) for measured delta(66/64)Zn, delta(67/64)Zn, and delta(68/64)Zn values, demonstrating the utility of the method for the precise isotopic analysis of Zn in biological materials. Relative to the selected Zn isotopic standard, delta(66/64)Zn values for biological samples varied from -0.60 per thousand in human hair to +0.56 per thousand in human whole blood, identifying the former material as the isotopically lightest Zn source found in nature to date.  相似文献   

2.
Lithium isotope composition of basalt glass reference material   总被引:2,自引:0,他引:2  
We present data on the lithium isotope compositions of glass reference materials from the United States Geological Survey (USGS) and the National Institute of Standards and Technology (NIST) determined by multicollector inductively coupled plasma mass spectrometry (MC-ICPMS), thermal ionization mass spectrometry (TIMS), and secondary ionization mass spectrometry (SIMS). Our data on the USGS basaltic glass standards agree within 2 per thousand, independent of the sample matrix or Li concentration. For SIMS analysis, we propose use of the USGS glasses GSD-1G (delta(7)Li 31.14 +/- 0.8 per thousand, 2sigma) and BCR-2G (delta(7)Li 4.08 +/- 1.0 per thousand, 2sigma) as suitable standards that cover a wide range of Li isotope compositions. Lithium isotope measurements on the silica-rich NIST 600 glass series by MC-ICPMS and TIMS agree within 0.8 per thousand, but SIMS analyses show systematic isotopic differences. Our results suggest that SIMS Li isotope analyses have a significant matrix bias in high-silica materials. Our data are intended to serve as a reference for both microanalytical and bulk analytical techniques and to improve comparisons between Li isotope data produced by different methodologies.  相似文献   

3.
A new method for the measurement of SI traceable carbon isotope amount ratios using a multicollector inductively coupled mass spectrometer (MC-ICPMS) is reported for the first time. Carbon (13)C/(12)C isotope amount ratios have been measured for four reference materials with carbon isotope amount ratios ranging from 0.010659 (delta(13)C(VPDB) = -46.6 per thousand) to 0.011601 (delta(13)C(VPDB) = +37 per thousand). Internal normalization by measuring boron (11)B/(10)B isotope amount ratios has been used to correct for the effects of instrumental mass bias. Absolute (13)C/(12)C ratios have been measured and corrected for instrumental mass bias and full uncertainty budgets have been calculated using the Kragten approach. Corrected (13)C/(12)C ratios for NIST RM8545 (Lithium Carbonate LSVEC), NIST RM8573 (L-Glutamic Acid USGS40), NIST RM8542 (IAEA-CH6 Sucrose) and NIST RM8574 (L-Glutamic Acid USGS41) differed from reference values by 0.06-0.20%. Excellent linear correlation (R = 0.9997) was obtained between corrected carbon isotope amount ratios and expected carbon isotope amount ratios of the four chosen NIST RMs. The method has proved to be linear within this range (from (13)C/(12)C = 0.010659 to (13)C/(12)C =0.011601), and therefore, it is suitable for the measurement of carbon isotope amount ratios within the natural range of variation of organic carbon compounds, carbonates, elemental carbon, carbon monoxide, and carbon dioxide. In addition, a CO2 gas sample previously characterized in-house by conventional dual inlet isotope ratio mass spectrometry has been analyzed and excellent agreement has been found between the carbon isotope amount ratio value measured by MC-ICPMS and the IRMS measurements. Absolute values for carbon isotope amount ratios traceable to the SI are given for each NIST RM, and the combined uncertainty budget (including instrumental error and each parameter contributing to Russell expression for mass bias correction) has been found to be < 0.1% for the four materials. The advantage of the method versus conventional gas source isotope ratio mass spectrometry measurements is that carbon isotope amount ratios are measured as C(+) instead of CO2(+), and therefore, an oxygen (17)O correction due to the presence of (12)C(17)O(16)O(+) is not required. Organic compounds in solution can be measured without previous derivatization, combustion steps, or both, thus making the process simple. The novel methodology opens new avenues for the measurement of absolute carbon isotope amount ratios in a wide range of samples.  相似文献   

4.
An accurate and precise method for the determination of delta34S measurements by multicollector inductively coupled plasma mass spectrometry has been developed. Full uncertainty budgets, taking into consideration all the uncertainties of the measurement process, have been calculated. The technique was evaluated by comparing measured values with a range of isotopically enriched sulfur solutions prepared by gravimetric addition of a 34S spike. The gravimetric and measured results exhibited a correlation of R2 >0.999. Repeat measurements were also made after adding Na (up to 420 microg g(-1)) and Ca (up to 400 microg g(-1)) salts to the sulfur standard. No significant deviations in the delta34S values were observed. The Russell correction expression (Ingle, C.; Sharp, B.; Horstwood, M.; Parrish, R.; Lewis, D. J. J. Anal. At. Spectrom. 2003, 18, 219) was used to correct for mass bias on the 34S/32S isotope amount ratio from the mass bias observed for the 30Si/28Si isotope amount ratio. Consistent compensation for instrumental mass bias was achieved. Resolution of the measured delta34S values was better than 1 per thousand after consideration of all uncertainty components. The technique was evaluated for practical applications by measurement of delta34S for a range of mineral waters by pneumatic nebulization sample introduction and the analysis of genuine and counterfeit pharmaceuticals using both laser ablation sample introduction and liquid chromatography. For the former two cases polyatomic interferences were resolved by operating the MC-ICPMS in medium resolution, while for the chromatographic analyses polyatomic interferences were minimized by the use of a membrane desolvator, allowing the instrument to be operated at a resolution of 400.  相似文献   

5.
A procedure is described for accurate Si isotope ratio measurements by multicollector inductively coupled plasma mass spectrometry (MC-ICPMS). Dissolved silicon was preconcentrated and separated from other elements present in natural surface waters using anion-exchange chromatography. The optimized procedure provides virtually complete elimination of major inorganic constituents while maintaining Si recovery in excess of 97%. High-resolution capabilities of MC-ICPMS used in this study allow interference-free measurements of 28Si and 29Si isotopes using conventional solution nebulization sample introduction without aerosol desolvation. Owing to the magnitude of polyatomic ion contributions in the region of mass 30, mostly from 14N16O+, measurements of the 30Si isotope can be affected by tailing of the interference signals, making exact matching of analyte and nitric acid concentrations in all measurement solutions mandatory. Isotope abundance ratio measurements were performed using the bracketing standards approach and on-line correction for mass-bias variations using an internal standard (Mg). Uncertainties, expressed as 95% confidence intervals, for replication of the entire procedure are better than +/-0.18/1000 for delta29Si and +/-0.5/1000 for delta30Si. For the first time with MC-ICPMS, the quality of Si isotope abundance ratio measurements could be verified using a three-isotope plot. All samples studied were isotopically heavier than the IRMM-018 Si isotopic reference material.  相似文献   

6.
We measured the Ni isotopic composition of metal from a variety of meteorite groups to search for variations in the 60Ni abundance from the decay of the short-lived nuclide 60Fe (t(1/2) = 1.49 My) and for possible nucleosynthetic effects in the other stable isotopes of Ni. We developed a high-yield Ni separation procedure based on a combination of anion and cation exchange chromatography. Nickel isotopes were measured on a single-focusing, multicollector, inductively coupled mass spectrometer (MC-ICPMS). The external precision on the mass-bias-corrected 60Ni/58Ni ratio (+/-0.15 epsilon; 2sigma) is comparable to similar studies using double-focusing MC-ICPMS. We report the first high-precision data for 64Ni, the least abundant Ni isotope, obtained via MC-ICPMS. The external precision on the mass-bias-corrected 64Ni/58Ni ratio (+/-1.5 epsilon; 2sigma) is better than previous studies using thermal ionization mass spectrometry. No resolvable excesses relative to a terrestrial standard in the mass-bias-corrected 60Ni/58Ni ratio were detected in any meteoritic metal samples. However, resolvable deficits in this ratio were measured in the metal from several unequilibrated chondrites, implying a 60Fe/56Fe ratio of approximately 1 x 10(-6) at the time of Fe/Ni fractionation in chondritic metal. A 60Fe/56Fe ratio of (4.6 +/- 3.3) x 10(-7) is inferred at the time of Fe/Ni fractionation on the parent bodies of magmatic iron meteorites and pallasites. No clearly resolvable non-mass-dependent anomalies were detected in the other stable isotopes of Ni in the samples investigated here, indicating that the Ni isotopic composition in the early solar system was homogeneous (at least at the level of precision reported here) at the time of meteoritic metal formation.  相似文献   

7.
We report an automated method for high-precision position-specific isotope analysis (PSIA) of carbon in amino acid analogues. Carbon isotope ratios are measured for gas-phase pyrolysis fragments from multiple sources of 3-methylthiopropylamine (3MTP) and isoamylamine (IAA), the decarboxylated analogues of methionine and leucine, using a home-built gas chromatography (GC)-pyrolysis-GC preparation system coupled to a combustion-isotope ratio mass spectrometry system. Over a temperature range of 620-900 degrees C, the characteristic pyrolysis products for 3MTP were CH4, C2H6, HCN, and CH3CN and for IAA products were propylene, isobutylene, HCN, and CH3CN. Fragment origin was confirmed by 13C-labeling, and fragments used for isotope analysis were generated from unique moieties with > 95% structural fidelity. Isotope ratios for the fragments were determined with an average precision of SD(delta13C) < 0.3% per thousand, and relative isotope ratios of fragments from different sources were determined with an average precision of SD(delta(delta)13C) < 0.5% per thousand. Delta(delta)13C values of fragments were invariant over a range of pyrolysis temperatures. The delta(delta)13C of complementary fragments in IAA was within 0.8% per thousand of the delta(delta)13C of the parent compounds, indicating that pyrolysis-induced isotopic fractionation is effectively taken into account with this calibration procedure. Using delta(delta)13C values of fragments, delta(delta)13C values were determined for all four carbon positions of 3MTP and for C1, C2, and the propyl moiety of IAA, either directly or indirectly by mass balance. Large variations in position-specific isotope ratios were observed in samples from different commercial sources. Most dramatically, two 3MTP sources differed by 16.30% per thousand at C1, 48.33% per thousand at C2, 0.37% per thousand at C3, and 5.36% per thousand at C(methyl). These PSIA techniques are suitable for studying subtle changes in intramolecular isotope ratios due to natural processes.  相似文献   

8.
We describe a new chemical separation method to isolate Ca from other matrix elements in biological samples, developed with the long-term goal of making high-precision measurement of natural stable Ca isotope variations a clinically applicable tool to assess bone mineral balance. A new two-column procedure utilizing HBr achieves the purity required to accurately and precisely measure two Ca isotope ratios ((44)Ca/(42)Ca and (44)Ca/(43)Ca) on a Neptune multiple collector inductively coupled plasma mass spectrometer (MC-ICPMS) in urine. Purification requirements for Sr, Ti, and K (Ca/Sr > 10?000; Ca/Ti > 10?000?000; and Ca/K > 10) were determined by addition of these elements to Ca standards of known isotopic composition. Accuracy was determined by (1) comparing Ca isotope results for samples and standards to published data obtained using thermal ionization mass spectrometry (TIMS), (2) adding a Ca standard of known isotopic composition to a urine sample purified of Ca, and (3) analyzing mixtures of urine samples and standards in varying proportions. The accuracy and precision of δ(44/42)Ca measurements of purified samples containing 25 μg of Ca can be determined with typical errors less than ±0.2‰ (2σ).  相似文献   

9.
A procedure is described for precise Hg isotope ratio measurements by solution nebulization multicollector inductively coupled plasma mass spectrometry (MC-ICPMS). Hg was released from geological samples using aqua regia extraction and then separated from other matrix elements with the aid of anion-exchange chromatography using strongly basic Dowex 1-X8 anion-exchange resin. Performance of the chromatographic procedure was evaluated using various types of replacement anions for elution of mercury, including l-cysteine, thiourea, NO3-, and SO42-. A solution of 0.15% l-cysteine in 0.06 M HCl was found to be the most convenient eluent for subsequent MC-ICPMS measurements. The optimized procedure provides separation of Hg from virtually all concomitant matrix elements while maintaining quantitative (>95%) recovery. In addition, band displacement chromatographic experiments were conducted to assess whether the anion-exchange purification can produce Hg isotope fractionation artifacts. No isotope fractionation between the Hg(II)-l-cysteine complex in aqueous solution and Hg ions in the anion-exchange resin was observed. Hg isotope ratio measurements were performed using the bracketing standards approach and on-line correction for instrumental mass discrimination using Tl spiking and normalization to the 205Tl/203Tl ratio. The absence of spectral interference during Hg isotope ratio measurements was verified using a three-isotope plot. Uncertainties of Hg isotope ratio measurements for replication of the entire procedure, expressed as two standard deviations, are better than +/-0.08 per thousand/amu. The described procedure facilitates study of variations in the isotopic composition of Hg in nature.  相似文献   

10.
Stable isotopic characterization of chlorine in chlorinated aliphatic pollution is potentially very valuable for risk assessment and monitoring remediation or natural attenuation. The approach has been underused because of the complexity of analysis and the time it takes. We have developed a new method that eliminates sample preparation. Gas chromatography produces individually eluted sample peaks for analysis. The He carrier gas is mixed with Ar and introduced directly into the torch of a multicollector ICPMS. The MC-ICPMS is run at a high mass resolution of >/=10 000 to eliminate interference of mass 37 ArH with Cl. The standardization approach is similar to that for continuous flow stable isotope analysis in which sample and reference materials are measured successively. We have measured PCE relative to a laboratory TCE standard mixed with the sample. Solvent samples of 200 nmol to 1.3 micromol (24-165 microg of Cl) were measured. The PCE gave the same value relative to the TCE as measured by the conventional method with a precision of 0.12 per thousand (2x standard error) but poorer precision for the smaller samples.  相似文献   

11.
Multicollector inductively coupled plasma mass spectrometry (MC-ICPMS) suffers large bias in isotope amount ratio determinations which has to be properly accounted for. The choice of the proper discrimination model is crucial. Over the last few decades, the exponential mass-bias correction model (Russell's law) has become a standard curriculum in isotope amount ratio measurements. In nature, however, isotopic fractionation that deviates significantly from the exponential model has been known for a long time. Recently, such fractionation was also observed in MC-ICPMS. This phenomenon is termed mass-independent fractionation. In this study, significant departure from the mass-dependent fractionation model is reported for germanium and lead with the most dramatic occurring for germanium-73 and lead-204 isotopes wherein, on average, close to a half percent bias was evidenced from the Russell's law.  相似文献   

12.
We report the first coupling of comprehensive two-dimensional gas chromatography (GC x GC) to online combustion isotope ratio mass spectrometry (C-IRMS). A GC x GC system, equipped with a longitudinally modulated cryogenic system (LMCS), was interfaced to an optimized low dead volume combustion interface to preserve <300 ms full width at half-maximum (fwhm) fast GC peaks generated on the second GC column (GC2). The IRMS detector amplifiers were modified by configuration of resistors and capacitors to enable fast response, and a home-built system acquired data at 25 Hz. Software was home-written to handle isotopic time shifts of less than one bin (40 ms) and to integrate peak slices to recover isotope ratios from cryogenically sliced peaks. The performance of the GC x GCC-IRMS system was evaluated by isotopic analysis of urinary steroid standards. Steroids were separated by a nonpolar GC1 column (30 m x 0.25 mm, 5% phenyl), modulated into multiple 4- or 8-s cryogenic slices by the LMCS, and then separated on a polar GC2 column (1 or 2 m x 0.1 mm, 50% phenyl). GC2 peak widths from a 1-m column averaged 276 ms fwhm. Steroid standard sliced peaks were successfully reconstructed to yield delta(13)C VPDB values with average precisions of SD(delta(13)C) = 0.30 per thousand and average accuracies within 0.34 per thousand, at 8 ng on column. Two steroids, coeluting in GC1, were baseline separated in GC2 and resulted in delta(13)C VPDB values with average precisions of SD(delta(13)C) = 0.86 per thousand and average accuracies within 0.26 per thousand, at 3 ng on column. Results from this prototype system demonstrate that the enhanced peak capacity and signal available in GC x GC is compatible with high-precision carbon isotope analysis.  相似文献   

13.
Isotope ratios and elemental concentrations were measured in aqueous solutions sampled at varying distances from sources of Fe or Zn ions. The measurements reveal fractionation of isotopes resulting from pure diffusion in solution. Our data demonstrate that diffusion alone can cause changes in (56)Fe/(54)Fe and (66)Zn/(64)Zn isotope ratios in excess of -0.3 per thousand. These findings thus confirm previous suspicions that transport processes contribute to observed variations in isotopic compositions. Diffusion must therefore be considered when attempting to make inferences from isotope measurements on samples originating from aqueous systems where concentration gradients may develop.  相似文献   

14.
An inductively coupled plasma mass spectrometer with dynamic reaction cell (ICP-DRC-MS) was optimized for determining (44)Ca/(40)Ca isotope ratios in aqueous solutions with respect to (i) repeatability, (ii) robustness, and (iii) stability. Ammonia as reaction gas allowed both the removal of (40)Ar+ interference on (40)Ca+ and collisional damping of ion density fluctuations of an ion beam extracted from an ICP. The effect of laboratory conditions as well as ICP-DRC-MS parameters such a nebulizer gas flow rate, rf power, lens potential, dwell time, or DRC parameters on precision and mass bias was studied. Precision (calculated using the "unbiased" or "n - 1" method) of a single isotope ratio measurement of a 60 ng g(-1) calcium solution (analysis time of 6 min) is routinely achievable in the range of 0.03-0.05%, which corresponded to the standard error of the mean value (n = 6) of 0.012-0.020%. These experimentally observed RSDs were close to theoretical precision values given by counting statistics. Accuracy of measured isotope ratios was assessed by comparative measurements of the same samples by ICP-DRC-MS and thermal ionization mass spectrometry (TIMS) by using isotope dilution with a (43)Ca-(48)Ca double spike. The analysis time in both cases was 1 h per analysis (10 blocks, each 6 min). The delta(44)Ca values measured by TIMS and ICP-DRC-MS with double-spike calibration in two samples (Ca ICP standard solution and digested NIST 1486 bone meal) coincided within the obtained precision. Although the applied isotope dilution with (43)Ca-(48)Ca double-spike compensates for time-dependent deviations of mass bias and allows achieving accurate results, this approach makes it necessary to measure an additional isotope pair, reducing the overall analysis time per isotope or increasing the total analysis time. Further development of external calibration by using a bracketing method would allow a wider use of ICP-DRC-MS for routine calcium isotopic measurements, but it still requires particular software or hardware improvements aimed at reliable control of environmental effects, which might influence signal stability in ICP-DRC-MS and serve as potential uncertainty sources in isotope ratio measurements.  相似文献   

15.
The stable isotope composition of dissolved organic carbon (delta(13)C-DOC) provides powerful information toward understanding carbon sources and cycling, but analytical limitations have precluded its routine measurement in natural samples. Recent interfacing of wet oxidation-based dissolved organic carbon analyzers and isotope ratio mass spectrometers has simplified the measurement of delta(13)C-DOC in freshwaters, but the analysis of salty estuarine/marine samples still proves difficult. Here we describe the coupling of the more widespread high-temperature catalytic oxidation-based total organic carbon analyzer to an isotope ratio mass spectrometer (HTC-IRMS) through cryogenic trapping of analyte gases exiting the HTC analyzer for routine analysis of delta(13)C-DOC in aquatic and marine samples. Targeted elimination of major sources of background CO2 originating from the HTC analyzer allows for the routine measurement of samples over the natural range of DOC concentrations (from 40 microM to over 2000 microM), and salinities (<0.1-36 g/kg). Because consensus reference natural samples for delta(13)C-DOC do not exist, method validation was carried out with water-soluble stable isotope standards as well as previously measured natural samples (IAEA sucrose, Suwannee River Fulvic Acids, Deep Sargasso Sea consensus reference material, and St. Lawrence River water) and result in excellent delta(13)C-DOC accuracy (+/-0.2 per thousand) and precision (+/-0.3 per thousand).  相似文献   

16.
Intramolecular carbon isotope ratios reflect the source of a compound and the reaction conditions prevailing during synthesis and degradation. We report here a method for determination of relative (Deltadelta13C) and absolute (delta13C) intramolecular isotope ratios using the volatile lactic acid analogue propylene glycol as a model compound, measured by on-line gas chromatography-pyrolysis coupled to GC-combustion-isotope ratio mass spectrometry. Pyrolytic fragmentation of about one-third of the analyte mass produces optimal fragments for isotopic analysis, from which relative isotope ratios (Deltadelta13C) are calculated according to guidelines presented previously. Calibration to obtain absolute isotope ratios is achieved by quantifying isotope fractionation during pyrolysis with an average fractionation factor, alpha, and evaluated by considering extremes in isotopic fractionation behavior. The method is demonstrated by calculating ranges of absolute intramolecular isotope ratios in four samples of propylene glycol. Relative and absolute isotope ratios were calculated with average precisions of SD(Deltadelta13C) <0.84 per thousand and SD(delta13C) <3.0 per thousand, respectively. The various fractionation scenarios produce an average delta(13)C range of 2 per thousand for each position in each sample. Relative isotope ratios revealed all four samples originated from unique sources, with samples A, B, and D only distinguishable at the position-specific level. Regardless of pyrolysis fractionation distribution, absolute isotope ratios showed a consistent pattern for all samples, with delta13C(3) > delta13C(2) > delta13C(1). The validity of the method was determined by examining the difference in relative isotope ratios calculated through two independent methods: Deltadelta13C calculated directly using previous methods and Deltadelta13C extracted from absolute isotope ratios. Deviation between the two Deltadelta13C values for all positions averaged 0.1-0.2 per thousand, with the smallest deviation obtained assuming equal fractionation across all fragment positions. This approach applies generally to all compounds analyzed by pyrolytic PSIA.  相似文献   

17.
Recent advances in gas chromatography combustion-isotope ratio mass spectrometry (GCC-IRMS) has made compound-specific isotope analysis routine, but reports on position-specific isotopic analysis are still scarce. On-line GC-pyrolysis (Py) coupled to GCC-IRMS is reported here for isolation and isotopic characterization of alaninol and phenethylamine, analogues of alanine and phenylalanine, respectively. Ideally, pyrolytic fragments will originate from unique sites within the parent molecule, and isotope ratios for each position within the parent can either be measured directly or calculated from fragment isotope ratios without substantially degrading the analytical precision. Alaninol pyrolysis yielded several fragments, of which CO and CH4 were used for isotope ratio calculations. Isotope labeling experiments showed that CO derived entirely from the C(1) position, while all three positions of alaninol contributed to CH4 (29.0 +/- 0.3% from C(1), 3.6 +/- 0.2% from C(2), and 66.9 +/- 1.1% from C(3)). We demonstrate iterative use of mass balance to calculate isotope ratios from all positions despite the nonideal positional fidelity of CH4. Pyrolysis of phenethylamine generated benzene and toluene fragments. Benzene derived entirely from C(ring), and toluene was proportionately formed from C(3) and C(ring). Relative intramolecular isotope ratios (Deltadelta13C) were calculated directly from delta13C of fragments or indirectly by mass balance. Though the C(3) isotope ratio was calculated from the benzene and toluene fragments, propagation of errors showed that the final precision of the determination was degraded due to the small contribution that C(3) makes to toluene. Samples of each amino acid from four different vendors showed natural variability between sources, especially at the C(1) position of alaninol (range of Deltadelta13C approximately 50 per thousand). The average precision was SD(Deltadelta13C) < 0.20 per thousand for directly measured positions of alaninol and phenethylamine. The precision of indirectly measured positions was poorer (SD(Deltadelta13C) = 0.94 per thousand for alaninol, 6.54 per thousand for phenethylamine) due to propagation of errors. These data demonstrate that GC-Py-GCC-IRMS data can be used to extract high-precision isotope ratios from amino acids despite nonideal positional fidelity in fragments and that natural intramolecular variability in delta13C can be used to distinguish different sources of amino acids.  相似文献   

18.
This work presents the simultaneous online determination of the isotopic composition of different Hg species in a single sample by the hyphenation of gas chromatography (GC) with multicollector-inductively coupled plasma mass spectrometry (MC-ICPMS). With the use of commercially available instrumentation, precise and accurate species-specific Hg isotope delta values (per mil deviation of the Hg isotope ratio in the sample relative to a reference standard) have been obtained online from consecutive GC transient signals. The use of isothermal temperature programs to extend the elution of the Hg species, the proper selection of the peak integration window, as well as the preconcentration of real samples are critical to provide optimal counting statistics. Also, isotope ratio drift during transient signal elution was overcome by introducing a mixed Hg(II) and MeHg standard bracketing scheme and expressing all results using the delta-notation relative to SRM NIST-3133. Using the proposed methodology, we have obtained an external 2SD precision of 0.56 per thousand for delta (202)Hg that is more than 10 times smaller than the overall Hg stable isotope variation thus far observed in terrestrial samples. The measurement of species-specific Hg isotopic composition relative to SRM NIST-3133 has been validated versus two other analytical techniques, i.e., conventional nebulization (CN) of Hg(II) solution and cold vapor (CV) generation of Hg (0) vapor. A good agreement between the species-specific delta values obtained by the different techniques has been obtained in secondary fractionated reference standard (UM-Almaden) and environmental matrixes, i.e., BCR-CRM 464 (tuna fish) and IAEA-085 (human hair). The results show mass-dependent and mass-independent fractionation in environmental samples, i.e., mass-independent fractionation of odd isotopes (199)Hg and (201)Hg in tuna fish was observed. This methodology provides new possibilities for the future study of species-specific stable isotope geochemistry of Hg and other trace metals.  相似文献   

19.
Sulfur isotope measurements offer comprehensive information on the origin and history of natural materials. Tunable laser spectroscopy is a powerful analytical technique for isotope analysis that has proven itself readily adaptable for in situ terrestrial and planetary measurements. Measurements of delta(34)S in SO2 were made using tunable laser spectroscopy of combusted gas samples from six sulfur-bearing solids with delta(34)S ranging from -34 to +22 per thousand (also measured with mass spectrometry). Standard deviation between laser and mass spectrometer measurements was 3.7 per thousand for sample sizes of 200 +/- 75 nmol SO(2). Although SO(2)(g) decreased 9% over 15 min upon entrainment in the analysis cell from wall uptake, observed fractionation was insignificant (+0.2 +/- 0.6 per thousand). We also describe a strong, distinct (33)SO(2) rovibrational transition in the same spectral region, which may enable simultaneous delta(34)S and Delta(33)S measurements.  相似文献   

20.
We present a rapid and selective method to increase the volatility of tyrosine and phenylalanine without adding derivative C for high-precision gas chromatography-continuous-flow isotope ratio mass spectrometry (GCC-IRMS) based on enzymatic decarboxylation to yield alkylamines and evaluated for 15N isotopic integrity. Purified tyrosine and phenylalanine were converted to tyramine and phenethylamine by tyrosine and phenylalanine decarboxylases, respectively. GC separation was achieved using a thick stationary phase (5-microm) capillary column. Recoveries were 95 +/- 2%. The reproducibility of delta15N of tyramine and phenethylamine measured by GCC-IRMS averaged SD(delta15N) = 0.33 per thousand. The absolute differences between delta15N of amino acids measured by elemental analyzer-IRMS and the alkylamines measured by GCC-IRMS was not significant. Phenethylamine and tyramine prepared from a mixture of 18 amino acids were extracted by ethanol with 95% recovery, and analysis yielded clean chromatograms and equivalent precision. These data indicate that enzymatic decarboxylation of phenylalanine and tyrosine is a convenient method to increase their volatility for continuous-flow isotopic analysis without introducing extraneous C or significant isotopic fractionation.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号