首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The performance prediction of Solar Integrated Collector–Storage System (ICS) is determined in terms of generalized dimensionless grouped parameters. These dimensionless parameters are primarily a combination of physical characteristics representing thermal performance curves for solar ICS systems and include information readily available to a designer pertaining to dimensions, thermal characteristics and operating conditions. The inter-relation between these is summarised as a nomogram and helps in predicting the system performance graphically for a particular locality or it may be deduced from it by simple hand calculation. This method does not require a detailed knowledge of system parameters for predicting system performance, and an advantage of this method is that short-term performance data is used to predict long-term performance and solar fraction. A simulation model was developed using a transient one-dimensional analysis for a solar ICS system. Time-dependent heat transfer coefficients and thermophysical properties were taken in the present simulation. © 1998 John Wiley & Sons, Ltd.  相似文献   

2.
An Integrated Collector Storage (ICS) solar water heater was designed, constructed and studied with an emphasis on its optical and thermal performance. The ICS system consists of one cylindrical horizontal tank properly mounted in a stationary symmetrical Compound Parabolic Concentrating (CPC) reflector trough. The main objective was the design and the construction of a low cost solar system with improved thermal performance based on the exploitation of the non-uniform distribution of the absorbed solar radiation on the cylindrical storage tank surface. A ray-tracing model was developed to gauge the distribution of the incoming solar radiation on the absorber surface and the results were compared with those from a theoretical optical model based on the average number of reflections. The variation of the optical efficiency as function of the incident angle of the incoming solar radiation along with its dependence on the month during annual operation of ICS system is presented. The ICS device was experimentally tested outdoors during a whole year in order to correlate the observed temperature rise and stratification of the stored water with the non-uniform distribution of the absorbed solar radiation. The results show that the upper part of the tank surface collects the larger fraction of the total absorbed solar radiation for all incident angles throughout the year. This is found to have a significant effect on the overall thermal performance of the ICS unit. In addition, the presented results can be considered important for the design and the operation of ICS systems consisting of cylindrical tank and CPC reflectors.  相似文献   

3.
A cylindrical collector-cum-storage type solar water heater has been designed, developed and tested. Its year round performance has been carried out and reported in this paper. The heater can provide 50 litres of hot water at 50–60°C in the afternoon and a temperature of 35°C can be retained till the next day for early morning use. The heater receives approximately 30% more radiation as compared to a flat surface. The economics of the heater has been worked out and it has been found that the cost can be recovered within one year.  相似文献   

4.
We present a simplified method which could be used to calculate, to a first approximation, the energy losses from the sides of a solar collector/water heater. The inclusion of energy losses through the side walls of a reasonable thickness reduce the efficiency of the system by about 5%. The integrated side energy losses for the whole day are not equal for the various segments of the wall. Hence, it will be economical to construct wedge shape walls, thickness decreasing downward, instead of usual rectangular walls.  相似文献   

5.
Systematic studies have been carried out on collector-cum-storage type solar water heaters, and efforts were made to minimise heat losses so that this type of water heater can be used for getting hot water at 40°–45°C for taking baths in the early morning hours of the next day. This paper reports year round performace, the performance equation and economics of this new improved solar water heater. This heater can supply 100 litres of hot water at 60°–70°C in the afternoon, and 40°–45°C temperature can be retained till next day morning. Its efficiency is 70.1%.  相似文献   

6.
A simple analysis of an underground shallow solar pond water heater has been presented. The effect of a thermal trap at the top of the system has also been incorporated in the analysis. Using the model, the effect of various system parameters, viz. thermal trap thickness, heat capacity of water mass, flow rate and duration of flow rate have been studied in detail. Numerical calculations have been made for a typical winter day at New Delhi (India). It is concluded that the system with thermal trap gives better performance in comparison with a system with a movable insulation system.  相似文献   

7.
8.
A solar water heater constructed from readily available materials in the countryside has earlier been discussed in the continuous flow mode. Water flows in the tubes at a constant rate throughout the day. In any realistic situation, however, the rate of flow will be a function of time depending on the requirements of the user. In this paper a theoretical method is developed which is used to predict the outlet water temperature of the time dependent flows. The effect of various design parameters like the position of the water pipes, choice of sensible heat storage material etc. are discussed taking different functions of rate of flow. The inexpensive water heater can provide hot water for a small household even in the late evening hours provided no heat is withdrawn from the system during the day time.  相似文献   

9.
The effect of thermal conductivity of the absorber plate of a solar collector on the performance of a thermo-siphon solar water heater is found by using the alternative simulation system. The system is assumed to be supplied of hot water at 50 °C and 80 °C whereas both are used in domestic and industrial purposes, respectively. According to the Rand distribution profile 50, 125 and 250 l of hot water are consumed daily. The condition shows that the annual solar fraction of the planning functions and the collector's configuration factors are strongly dependent on the thermal conductivity for its lower values. The less dependence is observed beyond a thermal conductivity of 50 W/m °C for the solar improper fraction and above 100 W/m °C for the configuration factors. In addition, the number of air ducts and total mass flow rate are taken to show that higher collector efficiency is obtained under the suitable designing and operating parameters. Different heat transfer mechanisms, adding natural convection, vapor boiling, cell nucleus boiling and film wise condensation is observed in the thermo-siphon solar water heater with various solar radiations. From this study, it is found that the solar water heater with a siphon system achieves system characteristic efficiency of 18% higher than that of the conventional system by reducing heat loss for the thermo-siphon solar water heater.  相似文献   

10.
The thermal performance of thermosyphon flat-plate solar water heater with a mantle heat exchanger was investigated to show its applicability in China. The effect on the performance of the collector of using a heat exchanger between the collector and the tank was analyzed. A “heat exchanger penalty factor” for the system was determined and energy balance equation in the system was presented. Outdoor tests of thermal performance of the thermosyphon flat-plate solar water heater with a mantle heat exchanger were taken in Kunming, China. Experimental results show that mean daily efficiency of the thermosyphon flat plate solar water heater with a mantle heat exchanger with 10 mm gap can reach up to 50%, which is lower than that of a thermosyphon flat-plate solar water heater without heat exchanger, but higher than that of a all-glass evacuated tubular solar water heater.  相似文献   

11.
There are various types of solar water heater system available in the commercial market to fulfill different customers’ demand, such as flat plate collector, concentrating collector, evacuated tube collector and integrated collector storage. A cost effective cum easy fabricated V-trough solar water heater system using forced circulation system is proposed. Integrating the solar absorber with the easily fabricated V-trough reflector can improve the performance of solar water heater system. In this paper, optical analysis, experimental study and cost analysis of the stationary V-trough solar water heater system are presented in details. The experimental result has shown very promising results in both optical efficiency of V-trough reflector and the overall thermal performance of the solar water heater.  相似文献   

12.
This article investigates experimentally the long-term thermal performance of a two-phase thermosyphon solar water heater and compares the results with the conventional systems. Experimental investigations are conducted to obtain the system thermal efficiencies from the hourly, daily and long-term performance tests. Different heat transfer mechanisms, including natural convection, geyser boiling, nucleate boiling and film-wise condensation, are observed in the two-phase thermosyphon solar water heater while solar radiation varies. The thermal performance of the proposed system is compared with that of four conventional solar water heaters. Results show that the proposed system achieves system characteristic efficiency 18% higher than that of the conventional systems by reducing heat loss for the two-phase thermosyphon solar water heater.  相似文献   

13.
In the present scenario, numerous applications perform on solar energy for cooking, heating and cooling, and power generation, globally. Solar air heaters are one of these applications purposely used for, drying, timber seasoning and space heating. In the present work, a solar air heater (SAH) has been designed to produce a good exhaust temperature for long hours especially in the case of poor ambient conditions or during off sunshine hours. A mixture of desert and granular carbon in the ratio of 4:6 has been used as thermal heat storage inside the SAH. Two halogen lights of 300 W are used to increase the exhaust temperature of the SAH by placing them in the inlet and outlet ducts. All the experiments have conducted on natural and forced convection for performance evaluation on two similar design solar air heaters (with and without heat storage). The comparisons are made with two similar design solar air heaters carrying desert and granular carbon, as an individual heat storing media, to find out an optimum design of a SAH with long term heating. The thermal efficiencies of the novel SAH range from 18.04% to 20.78% of natural convection and 52.21%–80.05% with forced convection.  相似文献   

14.
An experimental investigation has been carried out on a thermosyphon solar water heater. The system consisted of a flat-plate collector of 1.5 m2 absorber area with 21 tubes/m width and storage tank of 125 litre capacity. Experiments were carried out for both cloudy and clear weather conditions in winter and summer. The hourly system performance was evaluated for all test conditions. The final mean tank temperature was measured daily which enabled the calculation of the possible contribution of solar energy for domestic hot water supply in Basrah, Iraq (latitude 30.76°N). The system was tested at both no-load and loading conditions. Intermittent and continuous load was imposed, and system performance was evaluated for each condition.  相似文献   

15.
An analysis of the temperature stratification inside an Integrated Collector Storage Solar Water Heater (ICS-SWH) was carried out. The system takes the form of a rectangular-shaped box incorporating the solar collector and storage tank into a single unit and was optimised for simulation in Scottish weather conditions. A 3-month experimental study on the ICS-SWH was undertaken in order to provide empirical data for comparison with the computed results. Using a previously developed macro model; a number of improvements were made. The initial macro model was able to generate corresponding water bulk temperature in the collector with a given hourly incident solar radiation, ambient temperature and inlet water temperature and therefore able to predict ICS-SWH performance. The new model was able to compute the bulk water temperature variation in different SWH collectors for a given aspect ratio and the water temperature along the height of the collector (temperature stratification). Computed longitudinal temperature stratification results obtained were found to be in close agreement with the experimental data.  相似文献   

16.
An experimental investigation is carried out on a forced circulation solar water heater to assess its performance under various operating conditions. The system consisted of two identical collectors of total absorber area of 3.45 m2 and a storage tank of 200 litre capacity. Experiments were carried out during clear days with and without system loading for two water mass flow rates through the collector; namely 0.1305 kg/s and 0.06525 kg/s. The system was operated without thermostat control and with thermostat control at maximum and minimum settings. The collector efficiency improved with system loading. The improvement was better with increased hot water withdrawal from the system.  相似文献   

17.
In this paper, an integrated combined system of a photovoltaic (glass–glass) thermal (PV/T) solar water heater of capacity 200 l has been designed and tested in outdoor condition for composite climate of New Delhi. An analytical expression for characteristic equation for photovoltaic thermal (PV/T) flat plate collector has been derived for different condition as a function of design and climatic parameters. The testing of collector and system were carried out during February–April, 2007. It is observed that the photovoltaic thermal (PV/T) flat plate collector partially covered with PV module gives better thermal and average cell efficiency which is in accordance with the results reported by earlier researchers.  相似文献   

18.
This investigation reports a new type of solar water heating system without water pipes on the collector surface or a separate storage tank. The water to be heated continuously flows perpendicularly from an upper transparent cover to a porous absorber and is stored in a small volume beneath this assembly. Three different systems were designed, manufactured and tested but only one proved to be successful; this design indicated higher thermal efficiency compared to conventional collectors at high flow rates whereas at low flow rates the opposite is true.  相似文献   

19.
This paper presents the results of an experimental investigation of the performance for a new flat plate solar air heater (SAH) with several obstacles (Type I, Type II, and Type III) and without obstacles (Type IV). The efficiencies, the heat gain factors and heat loss coefficients are determined for the collectors and comparisons were made among them. The experimental data along with the correlations obtained by linear regression are presented. The optimal value of efficiency was determined for the solar air heater with Type II absorbent plate in flow channel duct for all operating conditions and the collector supplied with obstacles appears significantly better than that without obstacles.  相似文献   

20.
The operation of a continuous flow type domestic solar water heater is explained with the help of a schematic diagram. Steady state thermal analysis of such a water heater is carried out. A water heater of this type with a collector area of 1 m2 is subjected to tests. The experimental results are compared with predicted results. The experimental results have also been compared with those obtained from a water heater operating on thermosiphon flow. The performance of the continuous flow type water heater is shown to be comparable to that of the thermosiphon flow type. It is concluded that, in the Indian context, the continuous flow type water heater has more advantages than the thermosiphon flow type water heater in view of its low capital cost and the ease of operation and maintenance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号