首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The proton exchange membrane fuel cell (PEMFC) stack is a key component in the fuel cell/battery hybrid vehicle. Thermal management and optimized control of the PEMFC under real driving cycle remains a challenging issue. This paper presents a new hybrid vehicle model, including simulations of diver behavior, vehicle dynamic, vehicle control unit, energy control unit, PEMFC stack, cooling system, battery, DC/DC converter, and motor. The stack model had been validated against experimental results. The aim is to model and analyze the characteristics of the 30 kW PEMFC stack regulated by its cooling system under actual driving conditions. Under actual driving cycles (0–65 kW/h), 33%–50% of the total energy becomes stack heat; the heat dissipation requirements of the PEMFC stack are high and increase at high speed and acceleration. A PID control is proposed; the cooling water flow rate is adjusted; the control succeeded in stabilizing the stack temperature at 350 K at actual driving conditions. Constant and relative lower inlet cooling water temperature (340 K) improves the regulation ability of the PID control. The hybrid vehicle model can provide a theoretical basis for the thermal management of the PEMFC stack in complex vehicle driving conditions.  相似文献   

2.
Thermal management has been considered as one of the critical issues in proton exchange membrane fuel cell (PEMFC). Key roles of thermal management system are maintaining optimal operating temperature of PEMFC and diminishing temperature difference over a single fuel cell and stack. Severe temperature difference causes degradation of performance and deterioration of durability, so understanding temperature distribution inside a single fuel cell and stack is crucial. In this paper, two-phase HFE-7100 cooling method is suggested for PEMFC thermal management and investigated regarding temperature change inside a fuel cell. Also, the results are compared to single-phase water cooling method. Numerical study of temperature distribution inside a single PEMFC is conducted under various conditions for the two different cooling methods. Fuel cell model considering mass transfer, electrochemical reaction and heat transfer is developed.The result indicates that two-phase HFE-7100 cooling method has an advantage in temperature maintenance and temperature uniformity than single-phase water cooling method, especially in high current density region. It is also revealed that the cell temperature is less dependent on system load change with two-phase cooling method. It indicates that the fuel cell system with two-phase cooling method has high thermal stability. In addition, the effect of coolant flow rate and coolant inlet pressure in two-phase HFE-7100 cooling method are discussed. As a result, two-phase cooling method showed reliable cooling performance even with low coolant flow rate and the system temperature increased as coolant pressure rose.  相似文献   

3.
A fuel cell system model with detailed cooling module model was developed to evaluate the control algorithms of cooling module which is used for the thermal management of a proton exchange membrane fuel cell (PEMFC) system. The system model is composed of a dynamic fuel cell stack model and a detailed dynamic cooling module model. To extend modeling flexibility, the fuel cell stack model utilizes analytic approach to capture the transient behavior of the stack temperature corresponding to the change of the coolant temperature and the flow rate during load follow-up. The cooling module model integrated model of fan, water pump, coolant passage, and electric motors so that the model is capable of investigation of operating strategy of pump and fan.The fuel cell system model is applied to the investigation of the control logics of the cooling module. Since, it is necessary for the control of cooling module to define the reference conditions such as coolant temperature and fuel cell stack temperature, this study presents such thermal management criteria. Finally, two control algorithms were compared, a conventional control algorithm and a feedback control algorithm. As a consequence, the feedback control algorithm was found to be more suitable for the cooling module of the PEMFC stack, as they consume less parasitic power while producing more stack power compared to a conventionally controlled cooling module.  相似文献   

4.
As one of the most promising sustainable energy technologies available today, proton exchange membrane fuel cell (PEMFC) engines are becoming more and more popular in various applications, especially in transportation vehicles. However, the complexity and the severity of the vehicle operating conditions present challenges to control the temperature distribution in single cells and stack, which is an important factor influencing the performance and durability of PEMFC engines. It has been found that regulating the input and output coolant water temperature can improve the temperature distribution. Therefore, the control objective in this paper is regulating the input and output temperature of coolant water at the same time. Firstly, a coupled model of the thermal management system is established based on the physical structure of PEMFC engines. Then, in order to realize the simultaneous control of the inlet and outlet cooling water temperature of the PEMFC stack, a decoupling controller is proposed and its closed-loop stability is proved. Finally, based on the actual PEMFC engine platform, the effectiveness, accuracy and reliability of the proposed decoupling controller are tested. The experimental results show that with the proposed decoupling controller, the inlet and outlet temperatures of the PEMFC stack cooling water can be accurately controlled on-line. The temperature error range is less than 0.2 °C even under the dynamic current load conditions.  相似文献   

5.
The proton exchange membrane (PEM) fuel cell (PEMFC) is equipped with a series of auxiliary components which consume considerable amount of energy. It is necessary to investigate the design and operation of the PEMFC power system for better system performance. In this study, a typical PEMFC power system is developed, and a thermodynamic model of the system is established. Simulation is carried out, and the power distribution of each auxiliary component in the system, the net power and power efficiency of the system are obtained. This power system uses cooling water for preheating inlet gases, and its energy-saving effect is also verified by the simulation. On this basis, the exergy analysis is applied on the system, and the indexes of the system exergy loss, exergy efficiency and ecological function are proposed to evaluate the system performance. The results show that fuel cell stack and heat exchanger are the two components that cause the most exergy loss. Furthermore, the system performance under various stack inlet temperatures and current densities is also analyzed. It is found that the net power, energy efficiency and exergy efficiency of the system reach the maximum when the stack inlet temperature is about 348.15 K. The ecological function is maintained at a high level when the stack inlet temperature is around 338.15 K. Lower current density increases the system ecological function and the power and exergy efficiencies, and also helps decrease the system exergy loss, but it decreases the system net power.  相似文献   

6.
A lumped parameter dynamic model is developed for predicting the stack temperature, temperatures of the exit reactant gases and coolant water outlet in a proton-exchange membrane fuel cell (PEMFC) system. A dynamic model for a water pump is also developed and can be used along with the thermal model to control the stack temperature. The thermal and water pump models are integrated with the air flow compressor and PEMFC stack current–voltage models developed by Pukrushpan et al. to study the fuel cell system under open and closed-loop conditions. The results obtained for the aforementioned variables from open-loop simulation studies are found to be similar to the experimental values reported in the literature. Closed-loop simulations using the model are carried out to study the effect of stack temperature on settling times of other variables such as stack voltage, air flow rate, oxygen excess ratio and net power of the stack. Further, interaction studies are performed for selecting appropriate input–output pairs for control purpose. Finally, the developed thermal model can assist the designer in choosing the required number of cooling plates to minimize the difference between the cooling water outlet temperature and stack temperature.  相似文献   

7.
The cooling system of proton exchange membrane fuel cell (PEMFC) engine was simulated by 1D and 3D collaborative simulation method. Firstly, the resistance characteristics of the flow channel are obtained by simulating the airside flow model. A three-dimensional simulation model including dual fans and radiator is also established to simulate the airflow distribution. The one-dimensional simulation model of 30 kW PEMFC engine cooling system that are mainly composed of a thermostat, water pump, and fan and radiator model is established. Secondly, the heat dissipation performance of the cooling system is calculated by using the coupled simulation model. It is found that the simulation results of the amount of heat transferred are in good agreement with the experimental data by compromising, which proves that the model is reasonable. Finally, the thermal performance of the extreme operating conditions of the PEMFC system is simulated by means of a simulation model. By monitoring the flow of the pump and the fan speed, we can maintain the stack internal heat balances, so that the stack efficient and stable operation. The results demonstrate that the 3D simulation can get the distribution of fluid flow more accurately, while the simulation time of 1D thermal system is short and can guide the matching of heat transfer parts quickly.  相似文献   

8.
In proton exchange membrane fuel cell (PEMFC) operations, the electrochemical reactions produce a rise in temperature. A fuel cell stack therefore requires an effective cooling system for optimum performance. In this study, miniature heat pipes were applied for cooling in PEMFC. Three alternatives were considered in tests: free convection, forced convection cooling with air, and also water. An analytical model was developed to show the possibility of evoking heat from inside a fuel cell stack with different numbers of miniature heat pipes. An experiment setup was designed and then used for further analysis. The proposed experiment setup consisted of a simulated fuel cell that produced heat and a number of thermosyphon miniature heat pipes to evoke heat from the simulated fuel cell. The experiment results reported in this paper present advantages and disadvantages of each tested cooling scenario. Results show that each cooling scenario, using a different number of heat pipes, provided different heat removal rates for PEMFC cooling.  相似文献   

9.
The operation of proton exchange membrane fuel cell (PEMFC) stacks requires careful thermal and water management for optimal performance. Appropriate placement of cooling plates and appropriate cooling conditions are therefore essential. To study the impact of these design parameters, a two-phase model accounting for the conservation of mass, momentum, species, energy, and charge, a phenomenological model for the membrane, and an agglomerate model for the catalyst layer, is developed and solved. The model is validated for a single cell, in terms of both the local and the global current density, and good agreement is found. Four repetitive computational units are then identified for the number of single cells placed between the coolant plates: (i) one cell; (ii) two cells; (iii) three cells; and (iv) four cells. The flow fields in the single cells and the cooling plates are of a net type. The results show that there is a strong correlation between stack performance and the operating conditions/placement of the coolant plates. For the limiting case of one coolant plate between each unit cell, similar operating conditions can be achieved in every individual cell throughout the stack. As more cells are placed in between coolant plates, the stack performance drops due to an increase in temperature and decrease in water content in the membranes, unless the cooling temperature is lowered. The coolant temperature and inlet velocity need to be monitored carefully and adjusted to the operating conditions of the stack. This model can be employed for design and optimization of liquid water cooling of a PEMFC stack.  相似文献   

10.
Effective cooling is critical for safe and efficient operation of proton exchange membrane fuel cell (PEMFC) stacks with high power. The narrow range of operating temperature and the small temperature differences between the stack and the ambient introduce significant challenges in the design of a cooling system. To promote the development of effective cooling strategies, cooling techniques reported in technical research publications and patents are reviewed in this paper. Firstly, the characteristics of the heat generation and cooling requirements in a PEMFC stack are introduced. Then the advantages, challenges and progress of various cooling techniques, including (i) cooling with heat spreaders (using high thermal conductivity materials or heat pipes), (ii) cooling with separate air flow, (iii) cooling with liquid (water or antifreeze coolant), and (iv) cooling with phase change (evaporative cooling and cooling through boiling), are systematically reviewed. Finally, further research needs in this area are identified.  相似文献   

11.
为了改善质子交换膜燃料电池(PEMFC)内部的水热平衡,从而进一步改善PEMFC的输出性能,文章建立了PEMFC的三维模型,通过改变PEMFC的外界供给参数(进气速度、加湿率以及冷却水流速),应用COMSOL模拟仿真得到了PEMFC的极化曲线和功率曲线、流道和气体扩散层(GDL)的水浓度分布情况,以及冷却水流速对PEMFC温度的影响。研究结果表明:随着进气速度和加湿率的逐渐增加,PEMFC的输出性能均逐渐提升,但是,过高的加湿率可能导致电极水淹;随着冷却水流速的增加,PEMFC温度加速下降,膜内温度分布变得更均匀。  相似文献   

12.
《Journal of power sources》2002,109(2):287-293
This paper describes an energy recovery system that recovers waste thermal energy from a fuel cell stack and uses it for fuel reforming purposes. The energy recovery system includes a throttling valve, a heat exchanger, and a compressor, and is coupled with a coolant loop of the fuel cell stack. The feed stock of a fuel reformer, which is primarily a mixture of water and fuel, is vaporized in the heat exchanger and is compressed to a sufficiently high pressure before it is ducted into the fuel reformer. The performance of a fuel cell power plant equipped with the energy recovery system is evaluated. The results indicate that the power plant efficiency can be increased by more than 40% compared to that of a fuel cell power plant without the energy recovery system. Additionally, up to 90% of the waste heat generated in the fuel cell stack is recovered. As a result, the required heat dissipation capacity of the radiator that is used for cooling the fuel cell stack can be drastically reduced.  相似文献   

13.
A proton exchange membrane fuel cell (PEMFC) cogeneration system that provides high-quality electricity and hot water has been developed. A specially designed thermal management system together with a microcontroller embedded with appropriate control algorithm is integrated into a PEM fuel cell system. The thermal management system does not only control the fuel cell operation temperature but also recover the heat dissipated by FC stack. The dynamic behaviors of thermal and electrical characteristics are presented to verify the stability of the fuel cell cogeneration system. In addition, the reliability of the fuel cell cogeneration system is proved by one-day demonstration that deals with the daily power demand in a typical family. Finally, the effects of external loads on the efficiencies of the fuel cell cogeneration system are examined. Results reveal that the maximum system efficiency was as high as 81% when combining heat and power.  相似文献   

14.
刘阳  陈奔 《太阳能学报》2023,44(2):260-268
建立基于尾氢再循环的车用PEMFC氢气系统的集总参数模型和质子交换膜燃料电池堆的二维CFD模型,瞬态模拟研究额定功率工况下尾氢排放对系统及电堆工作特性的影响。结果表明:排放过程中,阳极进气压力和进气流量等参数出现显著的波动现象,且波动幅度和波动时间与排放持续时间存在直接关系;电堆性能在排放过程中有所下降,排放结束后能迅速恢复到排放前的水平;阳极内部的水气分布在排放过程中得到明显改善。  相似文献   

15.
This work experimentally investigates the effects of the pyrolytic graphite sheets (PGS) on the performance and thermal management of a proton exchange membrane fuel cell (PEMFC) stack. These PGS with the features of light weight and high thermal conductivity serve as heat spreaders in the fuel cell stack for the first time to reduce the volume and weight of cooling systems, and homogenizes the temperature in the reaction areas. A PEMFC stack with an active area of 100 cm2 and 10 cells in series is constructed and used in this research. Five PGS of thickness 0.1 mm are cut into the shape of flow channels and bound to the central five cathode gas channel plates. Four thermocouples are embedded on the cathode gas channel plates to estimate the temperature variation in the stack. It is shown that the maximum power of the stack increase more than 15% with PGS attached. PGS improve the stack performance and alleviate the flooding problem at low cathode flow rates significantly. Results of this study demonstrate the feasibility of application of PGS to the thermal management of a small-to-medium-sized fuel cell stack.  相似文献   

16.
This work characterizes the thermal management of a proton exchange membrane fuel cell (PEMFC) stack with combined passive and active cooling. A 10-cell PEMFC stack with an active area of 100 cm2 for each cell is constructed. Six thermally conductive 0.1-mm-thick Pyrolytic Graphite Sheets (PGSs) are cut into the shape of flow channels and bound to the six central cathode gas channel plates. These PGSs, which are lightweight and have high thermal conductivity, function as heat spreaders and fins and provide passive cooling in the fuel cell stack, along with two small fans for forced convection. Three other cooling configurations with differently sized fans are also tested for comparisons (without PGSs). Although the maximum power generated by the stack with the configuration combining PGSs and fans was 183 W, not the highest among all configurations, it significantly reduced the volume, weight, and cooling power of the thermal management system. Net power, specific power, volumetric power density, and back work ratio of this novel thermal management method are 179 W, 18.54 W kg−1, 38.9 kW m−3, and 2.1%, respectively, which are superior to those of the other three cooling configurations with fans.  相似文献   

17.
Thermal management is a critical issue in optimizing the performance of proton exchange membrane fuels cells (PEMFC). The heat balance between the heat generation in fuel cell stack (FCS) and the heat removal by coolant liquid determines the operating temperature of the PEMFC and the dehydration or flooding condition in FCS. In this study, the amount of water condensed among all the water produced during the electrochemical reaction in FCS of a hydrogen-fueled 1-kW PEMFC at various conditions was determined using a thermoeconomic method called modified productive structure analysis (MOPSA) and the calculated results were compared with observed ones. The amount of the condensed water which should be removed through the cathode channel is dependent crucially on the cooling rate of FCS, which indicates that thermal management for FCS can be done by controlling of the cooling rate of FCS.  相似文献   

18.
With the development of the information and communication technology (ICT) industry, the energy consumption of data centers is continuously increasing. High-temperature polymer electrolyte fuel cells (HT-PEFC) have a high operating temperature of 120 °C or higher; thus, the heat generated from fuel cells stack is effectively used as a heat source for a absorption refrigerator (AR) to generate cooling. The combined cooling and power (CCP) system is proposed to satisfy the energy demand of data centers that require both power and cooling. The CCP system comprises an HT-PEFC and a double-effect AR that recovers the wasted heat of the fuel cell stack. As a result of analyzing the electrical and cooling efficiency of the CCP system according to the fuel cell operating conditions, the overall efficiency increased to 95%, which was significantly higher than the existing system. Based on the simulation of the developed model, coefficient of performance (COP) and cooling capacity depending on the temperature changes of chilled water and cooling water were calculated within the stack temperature range of 150–180 °C, and the COP changed from 1.1 to 1.58 depending on the conditions. The developed CCP system model can be used to plan strategies for flexible fuel cell operation according to the power and cooling demands required in the data center.  相似文献   

19.
Proton exchange membrane fuel cells (PEMFCs) have been considered for combined heat and power (CHP) applications, but cost reduction has remained an issue for commercialization. Among various types of PEMFC, the high-temperature (HT) PEMFC is gaining more attention due to the simplicity of the system, that will make the total system cost lower. A pumpless cooling concept is introduced to reduce the number of components of a HT PEMFC system even further and also decrease the parasitic power required for operating the system. In this concept, water is used as the coolant, and the buoyancy force caused by the density difference between vapour and liquid when operated above boiling temperate is utilized to circulate the coolant between the stack and the cooling device. In this study, the basic parameters required to design the cooling device are discussed, and the stable operation of the HT PEMFC stack in both the steady-state and during transient periods is demonstrated. It found that the pumpless cooling method provides more uniform temperature distribution within the stack, regardless of the direction of coolant flow.  相似文献   

20.
UVC (ultrathin vapor chamber) simultaneously has a high heat-conducting property, excellent temperature uniformity and simple structure. These advantages are very suitable for thermal management of the open-cathode PEMFC (proton exchange membrane fuel cell) stack. In this work, two-type UVCs with different appearances are integrated into a conventional PEMFC stack respectively. The effect of UVC on the output performance, thermal management and operating stability is investigated by the experiment combined with simulation. The results show that UVC can significantly increase the output voltage under high current density. In 35 A, the output voltage of the stack integrated the vertical UVC increases by 20.25% relative to the conventional stack. Thermal management is also improved by UVC. The highest temperature inside the stack decrease by 9 °C in 35 A, and the membrane temperature is decreased obviously. But it still exceeds the optimal operating temperature of open-cathode PEMFC stack due to the poor cooling type in the condensation side of UVC. UVC improves the operation stability of the stack and slows the deteriorative speed of output performance. This work hopes to attract more attention to the application of UVC on the thermal management of portable power sources used open-cathode PEMFC stack.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号