首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
STUDY OBJECTIVES: To evaluate the clinical safety, efficacy, and cost of a small indwelling pleural catheter (7F, Turkel Safety Thoracentesis System [Sherwood, Davis, and Geck; St. Louis]) vs repeated needle thoracentesis or closed tube thoracostomy as a means to drain a large-volume pleural effusion. SETTING: Inpatients in a tertiary care university teaching hospital in urban Chicago. DESIGN: Prospective, consecutive patient comparative study using historical controls. PATIENTS: Fifty-seven therapeutic aspirations in 23 patients with large pleural effusions as defined by opacification of at least one third of the hemithorax on chest radiography. Patients were excluded if they had a history of thoracic surgery, documented loculations, structural chest abnormalities, severe coagulopathy, or refused to give informed consent. MEASUREMENTS: Volume of each pleural aspiration, total fluid removed, pleural fluid lactate dehydrogenase, protein, glucose, cytologic analysis, microbiologic stains, and cultures based on clinical indications. RESULTS: We found that initial thoracentesis and repeated pleural drainage using the indwelling catheter system is a safe, efficacious, and cost-effective procedure that may aid the evacuation and management of a large-volume pleural effusion. There were fewer adverse effects and complications such as pneumothorax, splenic laceration, hemopneumothorax, local pain, dry tap, and hematomas, as compared with previous reports. The overall complication rate was 12% (7/57). There were two pneumothoraces detected (3.5%), one of which required closed tube thoracostomy for treatment (1.75%). A further benefit comes in the form of a significant cost savings at our institution ($80 vs $240) when this needle-catheter system is used in place of closed tube thoracostomy in the drainage of a large-volume pleural effusion. CONCLUSION: An indwelling pleural catheter with the Turkel safety needle-catheter (as described in the study) can be used to successfully drain the pleural space with reduced morbidity and a significant cost saving in comparison to repeated needle thoracenteses or closed tube thoracostomy.  相似文献   

2.
The present study was undertaken to ascertain the feasibility of using a 25-gauge needle for arterial punctures. A total of 11,500 arterial punctures were performed over the past four years by this technique without any major complication. Repeated arterial punctures were well tolerated by all patients, and the necessity for indwelling arterial catheters was almost totally eliminated during this period of study.  相似文献   

3.
To determine and compare the efficacy of pleural fluid cytology and closed needle biopsy of the pleura in establishing the diagnosis of malignant pleural effusions in Yaounde, we reviewed the medical records of all consecutive patients with a pleural effusion admitted in unit B of the Chest Clinic of the Jamot Hospital between January 1990 and December 1994. Fifty four cases of malignant pleural effusion were diagnosed over this period. Closed needle biopsy of the pleura alone permitted a diagnosis of malignancy involving the pleura in 32 instances while cytological studies of pleural fluid provided a diagnosis in thirty six cases. A combination of both techniques was diagnostic in 48 (88.9%) patients. We recommend that both pleural fluid cytology and closed needle biopsy of the pleura be used concomitantly in the evaluation of pleural effusion for which malignancy is suspected.  相似文献   

4.
BACKGROUND: Radiologically guided needle biopsy and cytologic evaluation provide a reliable method of diagnosis for planning definitive therapy of patients with mediastinal lesions. MATERIALS AND METHODS: In this retrospective study of one of the largest series from a single institution, 141 consecutive mediastinal needle biopsies from 139 patients were reviewed during a 15-year period. RESULTS: Adequate material was obtained with a diagnosis achieved in 128 cases (92%). Of these, 33 cases (26%) had benign diagnoses; the remaining 95 (74%) had malignant diagnoses, including 81 carcinomas, 3 sarcomas, 8 lymphoproliferative lesions, 2 malignant germ cell tumors, and 1 malignant thymoma. All benign cases were diagnostically confirmed, and 94 of 95 malignant cases were classified correctly. The only discrepancy that occurred involved a malignant lymphoma diagnosed as a malignant germ cell tumor. Of the 13 inadequate samples, the major category included a nodular sclerosis variant of Hodgkin's disease (4 cases), 1 case of thymoma, 1 case of tuberculous lymphadenitis, and 7 cases for which no follow-up data were available. CONCLUSION: Needle biopsy is reaffirmed as a reliable and sensitive diagnostic tool for mediastinal lesions, with an overall cytologic diagnostic accuracy of 99% with adequate material. Sclerotic lesions may pose a limitation to this technique and require generous sampling before a more invasive diagnostic procedure is undertaken.  相似文献   

5.
A modification of the aspiration liver biopsy technique using a large-caliber disposable needle is described in an 18-month experience. One hundred forty liver biopsies were performed, obtaining adequate tissue in 98% of the patients. Complications occurred in 12 patients and were limited to pain at the biopsy site, epigastrium, or right shoulder; one instance of tachycardia and three of transient hypotension occurred. Thirty patients studied prospectively with liver scans and hematologic parameters failed to disclose subclinical complications. While the number of patients biopsied is still too small to provide definite conclusions , it appears that this technique is safe, similar and has a very high yield of excellent specimens. In addition, the needle offers the advantage of being disposable and easy to use by a single operator.  相似文献   

6.
From a retrospective study of 259 files, the authors stress the value of US-guided thyroid cytoponction and its essential role in case of thyroid cancer suspicion. This very specific and inexpensive method fits perfectly into the other exploration techniques. It is the deciding factor in the thyroid nodule differential diagnostic and therapeutic planning.  相似文献   

7.
AIMS: We retrospectively investigated the diagnostic accuracy and complication rate of transthoracic core biopsy using an automated biopsy gun and compared the findings with those of aspiration needle biopsy. PATIENTS AND METHODS: Seventy-three patients underwent 74 core biopsy procedures and 50 patients underwent 52 aspiration biopsy procedures. Of these, a final diagnosis was obtained in 107 lesions with surgery or clinical course. Fifteen patients in which a final diagnosis was not obtained were excluded from the study on diagnostic accuracy. Thus, in the study of diagnostic accuracy, 63 core biopsy procedures for 62 lesions are included. Core biopsy was performed with an 18 G cutting needle using an automated biopsy gun. Aspiration biopsy was performed with a 20 G aspiration needle. RESULTS: Core biopsy yielded sufficient material in 57/63 procedures (90.5%). A correct diagnosis was obtained in 36 procedures (85.7%) for malignant leisons and a specific benign diagnosis was obtained in 11 procedures (52.4%). Aspiration biopsy yielded a correct diagnosis in 26 procedures (81.3%) for malignant leisons and in seven (46.7%) for benign lesions. The overall correct diagnosis were 75.8% and 71.7% with core biopsy and aspiration biopsy, respectively. Core biopsy gave a higher predictive rate than that of aspiration biopsy for both benign and malignant lessons (P < 0.02). Pneumothorax occurred in 18/74 (24.3%) patients with core biopsy and in 18/45 (40.0%) patients with aspiration biopsy. Of these, three with core biopsy and two with aspiration biopsy needed tube drainage. The other complication was haemoptysis, which occurred in six patients following core biopsy and in three after aspiration biopsy. All nine cases subsided spontaneously. There were no fatal complications. CONCLUSIONS: Core biopsy with a biopsy gun increase the diagnostic accuracy with a higher histologic predictive rate and no obvious additional risk of complications.  相似文献   

8.
9.
Using a computed tomography (CT)-guided technique we have been able to obtain fine needle spine biopsies directly from an affected vertebra or disk plate in 14 patients suspected of infectious spondylitis. The bioptic material was cultivated immediately and incubated for 14 days. Cultures from eight patients were positive. No single microbiological agent was predominant though coagulase-negative staphylococci were frequent. In no case were mycobacteria found. Bioptic material from six patients did not give rise to growth of microorganisms. We were able to successfully treat the eight patients with a culture-positive biopsy. We think that biopsies are crucial for establishing a microbiological diagnosis. The whole procedure takes less than one hour; it is performed under local anaesthesia and is thus not very stressful for the patient: The success rate for obtaining a positive spine biopsy was 57%.  相似文献   

10.
This study evaluates the efficacy of ultrasound guided percutaneous biopsy using an 18 gauge automated side-cutting needle in the diagnosis of small (< or = 3 cm) focal hepatic lesions. 137 consecutive percutaneous biopsies of 131 different small (< or = 3 cm) focal hepatic lesions were included. 11 biopsies were performed on lesions of < or = 1 cm in diameter, 56 were on lesions 1.1-2 cm in size and 70 on lesions 2.1-3 cm in size (average 2.3 +/- 0.7 cm; median 2.3 cm; range 0.7-3 cm). The biopsy specimen was sufficient for diagnosis in 135 cases (98.5%). The sensitivity for diagnosing malignancy was 96.4%; specificity was 100%, positive and negative predictive values were 100% and 94.6%, respectively; accuracy was 97.8%. There was no statistically significant difference in the diagnostic efficacy for lesions of different pathology and size. No significant post-biopsy complication occurred. It is concluded that the 18 gauge Temno needle is safe and effective in diagnosing small hepatic lesions.  相似文献   

11.
12.
The use of the technique of percutaneous needle biopsy in obtaining skeletal muscle samples in the horse is described. The biochemical, ultrastructural and histochemical investigations that can be carried out on this biopsy specimen are outlined. Analyses performed on the specimen may be used to obtain information on racing potential and state of fitness. These studies on normal horses will provide information for future investigations into the structural and biochemical alterations in muscle disorders in the equine.  相似文献   

13.
OBJECTIVE: To determine the fine needle aspiration biopsy (FNAB) findings in hepatic Echinococcus multilocularis. STUDY DESIGN: FNAB and tru-cut liver needle biopsy were applied in 14 hepatic E multilocularis cases. Cytologic smears were stained with May-Grünwald-Giemsa and periodic acid-Schiff (PAS) stain. Tissue sections were stained with hematoxylin-eosin (HE) and PAS stain. RESULTS: In tissue sections, homogeneous, thin, cystic structures of various dimensions strongly stained with PAS. Mucoid material was stained with PAS in the cystic structures. Wide, coagulative necrosis was observed in all cases. In some cases there were foreign body-type giant cells at the periphery of the lesion. In all the cytologic smears there were an intense necrotic ground, PAS-positive hyaline cuticular structures and mucoid globules; in some cases there were foreign body-type giant cells. CONCLUSION: The above cytologic characteristics are basic diagnostic criteria for FNAB of E multilocularis.  相似文献   

14.
OBJECTIVES: Gleason grade from prostate needle biopsy (PNB) specimens is important in guiding therapeutic decision making in patients with localized prostate cancer. Recent data from our institution suggest a significant discordance between Gleason grading from PNB versus the actual pathologic grade at radical prostatectomy (RRP). Of most concern is that a substantial proportion of patients with Gleason score of 6 or less from PNB actually have Gleason score of 7 or more at RRP. Under classic measurement theory, one useful way to improve the reliability of an inherently unreliable test is to repeat it. We investigated this strategy in an effort to reduce undergrading errors. METHODS: The control group of patients (n = 51) from our neoadjuvant androgen deprivation protocol was used as the test (two-biopsy) group in this study. These patients underwent two separate PNBs before RRP. We used the highest Gleason score from the two biopsies in these patients and compared the error rates with a concurrent group of patients treated at our institution (n = 226) who had only one set (single-biopsy group) of prostate biopsies. All pathologic slides were reviewed at our institution. Any PNB grade of 6 or less that was scored as 7 or more on final pathology was considered significant. RESULTS: Mean age, prostate-specific antigen levels, and stage distribution were not significantly different between these two groups. In the single-biopsy group, 165 patients had PNB Gleason score of 6 or less. Of these patients, 63 (38%) had final pathologic grade of 7 or more. In the two-biopsy group, 37 patients had PNB Gleason score of 6 or less. Of these patients, only 7 (19%) had final pathologic grade of 7 or more (P = 0.04). CONCLUSIONS: Prostate rebiopsy minimizes the inherent unreliability of PNB derived grade and should be considered for patients in whom watchful waiting or nomogram-based therapy has been selected.  相似文献   

15.
A special interest, both in scientific publications and in the mass media, is recently emerged about the use of hormone replacement therapy (HRT) in post-menopausal women. Beside, in fact, the specific indication for the relief of menopausal symptoms, hypotheses are debated about a possible role of HRT in the reduction of risk of osteoporosis and cardiovascular diseases, and in the increased risk of breast cancer. This situation emphasizes the need for assessing the benefit/risk profile for HRT in order to ensure that strategies of proven clinical effectiveness, based on large randomized clinical trials, will be adopted in the population.  相似文献   

16.
The excitatory neurotransmitter glutamate coexists with the peptide known as substance P in primary afferents that respond to painful stimulation. Because blockers of glutamate receptors reliably reduce pain behaviour, it is assumed that 'pain' messages are mediated by glutamate action on dorsal horn neurons. The contribution of substance P, however, is still unclear. We have now disrupted the mouse preprotachykinin A gene (PPT-A), which encodes substance P and a related tachykinin, neurokinin A. We find that although the behavioural response to mildly painful stimuli is intact in these mice, the response to moderate to intense pain is significantly reduced. Neurogenic inflammation, which results from peripheral release of substance P and neurokinin A, is almost absent in the mutant mice. We conclude that the release of tachykinins from primary afferent pain-sensing receptors (nociceptors) is required to produce moderate to intense pain.  相似文献   

17.
OBJECTIVE: To review the fine needle aspiration (FNA) findings in 151 patients who presented with salivary gland (both major and minor) enlargement from January 1991 to December 1995 in order to determine its sensitivity and specificity and to study the various pitfalls. STUDY DESIGN: The study group consisted of 77 males and 74 females, 16-98 years old (average 55). One hundred twenty-five aspirates (83%) were from the parotid gland, 23 (15%) from the submandibular gland and 3 (2%) from the soft palate. One hundred thirty-seven cases (91%) were adequate for diagnosis. There were 89 (59%) aspirations done by cytopathologists, 100% of which were diagnostic, and 62 (41%) done by clinicians, 48 (77%) of which were diagnostic. Sixty-eight (45%) cases had histologic confirmation. There were 104 (75.9%) benign, 20 (14.6%) malignant and 13 (9.5%) atypical cytologic diagnoses. RESULTS: Using histology as the "gold standard," the sensitivity of FNA cytology was 91%, with a specificity of 96%. A number of problems were encountered in interpreting some cases, not only in differentiating benign from malignant ones but also in the specific classification of these neoplasms. Problems encountered involved differentiating hematopoietic from non-hematopoietic lesions and interpretation of spindle cell neoplasms, acinic cell carcinoma, mucoepidermoid carcinoma, adenoid cystic carcinoma, lymphoproliferative disorders, postirradiation changes, sialadenitis and atypia in pleomorphic adenoma. CONCLUSION: FNA biopsy of the salivary gland is a sensitive and specific diagnostic tool at our institution. Particular attention to subtle morphologic changes may aid in avoiding pitfalls and arriving at the right diagnosis.  相似文献   

18.
BACKGROUND: The introduction of automated biopsy devices and the localization of the kidney by ultrasound were aimed at optimizing efficacy and safety of the percutaneous renal biopsy procedure. We evaluated these technological advances in our renal biopsies performed in children. METHODS: We sequentially used the Silverman needle (1969-1974), the TruCut needle (1974-1990), and the automated Biopty device (1990-1996). Fluoroscopy was used to localize the kidney until 1985, ultrasound examination prior to biopsy from 1985 to 1992, and direct ultrasound guidance since 1992. A total of 962 native kidney biopsies and 119 allograft biopsies were performed. RESULTS: In the native kidney biopsies, the introduction of the Biopty device and ultrasound guidance were independently associated with fewer passes required to obtain adequate tissue and more glomeruli per specimen. The rate of biopsies yielding more than 9 glomeruli increased from 69 to 92% (p < 0.05). The number of glomeruli harvested per centimeter core length was inversely related to patient age (p < 0.01). More appropriate cortical tissue was retrieved in renal allograft biopsy specimens with the application of the new techniques. The occurrence of macroscopic hematuria (9. 6%) in the native kidney biopsies was not affected by the puncture or localization technique applied, but subcapsular hematomas were documented more often with the Biopty device (42%) than with the TruCut needle (16%), probably due to improved ultrasound equipment. In the whole series 2 patients died, and 3 others required renal surgery and 4 blood transfusions. CONCLUSIONS: The automated ultrasound-guided procedure is a feasible and reliable technique for percutaneous renal biopsy in children. It gives a greater yield of diagnostic tissue without increasing the rate of clinical complications.  相似文献   

19.
OBJECTIVES: Patients with elevated prostate-specific antigen (PSA) and no access to the rectum present a diagnostic challenge to the urologist. This study was undertaken to determine the efficacy of transperineal prostate biopsy using transurethral ultrasound guidance for the detection of prostate cancer. METHODS: Five men status post either total colectomy or abdominoperineal resection (age range: 58 to 73 years, mean age 65.8 years) were referred to us for the evaluation of an elevated PSA (range: 5.6 to 21.4 ng/dL, mean 16.1 ng/dL). Seven procedures were performed utilizing transurethral ultrasound to guide transperineal prostate biopsies in these men. RESULTS: Biopsy results revealed benign prostatic hyperplasia in 4 procedures and prostate cancer in 3 procedures. CONCLUSIONS: Transurethral ultrasound enables the practitioner to perform accurate sonographic assessment and precise biopsy of the prostate in such patients.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号