共查询到20条相似文献,搜索用时 0 毫秒
1.
Design, fabrication, and evaluation of microfabricated columns for gas chromatography 总被引:1,自引:0,他引:1
Lambertus G Elstro A Sensenig K Potkay J Agah M Scheuering S Wise K Dorman F Sacks R 《Analytical chemistry》2004,76(9):2629-2637
The design, fabrication, and performance of gas chromatography columns etched in silicon substrates are described. Deep reactive-ion etching formed the 3-m-long, 150-microm-wide, 240-microm-deep rectangular cross section channels. A glass cover plate was anodically bonded to the remaining surface of the substrate forming the gastight channel. For some of the columns, the silicon channels were oxidized before the channels were sealed with the glass plates. Fused-silica capillary connecting tubes were sealed into ports on the edge of the 3.2-cm x 3.2-cm substrate chips. Dynamic coating was used to deposit a film of nonpolar dimethyl polysiloxane or moderately polar trifluoropropylmethyl polysiloxane stationary phase. The columns were evaluated in a conventional benchtop GC instrument with split injection and flame ionization detection. Column efficiency was evaluated by the use of plots of height equivalent to a theoretical plate versus average carrier gas velocity using both hydrogen and air as carrier gases. The number of theoretical plates measured at the average carrier gas velocity giving the minimum plate height ranged from 4600 to 8200 plates for the dimethyl polysiloxane columns and from 3500 to 5500 plates for the trifluoropropylmethyl polysiloxane columns. Minimum plate height was significantly smaller with air as carrier gas. For the nonpolar phase, the nonoxidized surface gave approximately 1500 plates more than the oxidized surface for both carrier gases. For the polar phase, the oxidized surface gave approximately 200 plates more than the nonoxidized surface. Isothermal chromatograms of a 20-component multifunctional mixture and temperature-programmed chromatograms of a normal alkane mixture are presented. 相似文献
2.
A series-coupled ensemble of microfabricated GC columns made by dry reactive ion etching of silicon substrates is evaluated for use with pneumatic selectivity enhancement techniques for targeted pairs of volatile organic compounds. Each column is 3.0 m long with a 150 miceom wide by 240 microm deep cross section. Dynamic coating was used to prepare a nonpolar column with a dimethyl polysiloxane stationary phase and a moderately polar column with a trifluoropropylmethyl polysiloxane stationary phase. Each column generates 5000-6000 theoretical plates. The columns are operated in series with the nonpolar column connected to a split inlet, the polar column connected to a flame ionization detector, and a valve connected between the column junction point and the inlet to the first column. When the valve is closed, the effluent from the first column passes directly into the second column. When the valve is open, both ends of the first column are at the inlet pressure, and flow stops in this column while increased flow is obtained in the second column. For analyte pairs that are separated by the first column but coelute from the column ensemble, the valve is opened for a few seconds after the first component of the pair has passed into the second column but the second component is still in the first column. The result is enhanced separation of the pair in the ensemble chromatogram. Relatively thick cross-linked stationary-phase films are used to increase retention for volatile compounds. The combination of air carrier gas and stationary-phase film thickness in the range 1-2 microm requires the use of relatively low average carrier gas velocities (typically less than 10 cm/s) for adequate resolving power of the column ensemble. Selectivity enhancement under isothermal conditions for a 14-component mixture of volatile organic compounds is demonstrated where neither of the columns alone nor the column ensemble without selectivity enhancement could obtain a complete separation. 相似文献
3.
Columns were fabricated in silicon substrates by deep reactive-ion etching. The channels were sealed with a glass wafer anodically bonded to the silicon surface. Heaters and temperature sensors were fabricated on the back side of each column chip. A microcontroller-based temperature controller was used with a PC for temperature programming. Temperature programming, with channel lengths of 3.0 and 0.25 m, is described. The 3.0-m-long channel was fabricated on a 3.2 cmx3.2 cm chip. Four columns were fabricated on a standard 4-in. silicon wafer. The 0.25-m-long channel was fabricated on a 1.1 cmx1.1 cm chip, and approximately 40 columns could be fabricated on a 4-in. wafer. All columns were coated with a nonpolar poly(dimethylsiloxanes) stationary phase. A static coating procedure was employed. The 3.0-m-long column generated about 12000 theoretical plates, and the 0.25-m-long channel generated about 1000 plates at optimal carrier gas velocity. Linear temperature ramps as high as 1000 degrees C/min when temperature programmed from 30 to 200 degrees C were obtained with the shorter column. With the 0.25-m-long column, normal alkanes from n-C5 through n-C15 were eluted in less than 12 s using a temperature ramp rate of 1000 degrees C/min. Temperature uniformity over the column chip surface was measured with infrared imaging. A variation of about 2 degrees C was obtained for the 3.0-m-long channel. Retention time reproducibility with temperature programming typically ranged from +/-0.15% to +/-1.5%. Design of the columns and the temperature controller are discussed. Performance data are presented for the different columns lengths. 相似文献
4.
A microfabricated thermal modulator (μTM) designed for ultimate use in a comprehensive two-dimensional microscale gas chromatography (μGC × μGC) system is evaluated. The 2-stage device measures 13 mm (l) × 6 mm (w) × 0.5 mm (h) and consists of two interconnected serpentine etched-Si microchannels suspended from a thin Pyrex cap and wall-coated with PDMS (polydimethylsiloxane). The chip is mounted within a few tens of micrometers of a thermoelectric cooler that maintains both stages at a baseline temperature between -35 and -20 °C in order to focus analytes eluting from an upstream separation column. Each stage is heated to 210 °C sequentially at a rate as high as 2400 °C/s by independent thin-film resistors to inject the analytes in consecutive fractions to a downstream column, and then cooled at a rate as high as -168 °C/s. The average power dissipation is only ~10 W for heating and 21 W for cooling without using consumable materials. In this study, the outlet of the μTM is connected directly to a flame ionization detector to assess its performance. Following a demonstration of basic operation, the modulated peak amplitude enhancement (PAE) and full-width-at-half-maximum (fwhm) are evaluated for members of a series of n-alkanes (C(6)-C(10)) as a function of the rim and stage temperatures; modulation period, phase, and offset; analyte concentration; and carrier-gas flow rate. A PAE as high as 50 and a fwhm as narrow as 90 ms are achieved for n-octane under optimized conditions. 相似文献
5.
Stadermann M McBrady AD Dick B Reid VR Noy A Synovec RE Bakajin O 《Analytical chemistry》2006,78(16):5639-5644
The key to rapid temperature programmed separations with gas chromatography are a fast, low-volume injection and a short microbore separation column with fast resistive heating. One of the major problems with the reduction of column dimensions for micro gas chromatography is the availability of a stationary phase that provides good separation performance. In this report, we present the first integration of single-wall carbon nanotubes (SWNTs) as a stationary phase into 100 mum x 100 mum square and 50-cm-long microfabricated channels. The small size of this column with integrated resistive heater and the robustness of the SWNT phase allow for fast temperature programming of up to 60 degrees C/s. A combination of the fast temperature programming and the narrow peak width of small-volume injections that can be obtained from a high-speed, dual-valve injection system allows for rapid separations of gas mixtures. We demonstrate highly reproducible separations of four-compound test mixtures on these columns in less than 1 s using fast temperature programming. 相似文献
6.
Several immobilization methods were explored for the preparation of high-performance affinity monolithic columns containing human serum albumin (HSA). These monoliths were based on a copolymer of glycidyl methacrylate and ethylene dimethacrylate. In one method, the epoxy groups of this copolymer were used directly for the immobilization of HSA through its amine residues (i.e., the epoxy method); in other approaches, these epoxy groups were converted to diols for later use in the carbonyldiimidazole, disuccinimidyl carbonate, and Schiff base methods. Each HSA monolith was evaluated in terms of its total protein content and its retention of several model compounds, including (R/S)-warfarin and D/L-tryptophan. The greatest amount of immobilized HSA was obtained by the Schiff base method, whereas the epoxy method gave the lowest protein content. The Schiff base method also gave the best resolution in chiral separations of (R/S)-warfarin and D/L-tryptophan. All of the immobilization methods gave similar relative activities for HSA in its binding to (R)- and (S)-warfarin, but some differences were noted in the activity of the immobilized HSA for D- and L-tryptophan. The efficiency of these monoliths was found to be greater than that of silica-based HSA columns for (R/S)-warfarin (i.e., analytes with high retention), but little or no difference was seen for D- and L-tryptophan (analytes with weak retention). 相似文献
7.
Koji Yamada Tai Tsuchizawa Hidetaka Nishi Rai Kou Tatsurou Hiraki Kotaro Takeda 《Science and Technology of Advanced Materials》2014,15(2)
By way of a brief review of Si photonics technology, we show that significant improvements in device performance are necessary for practical telecommunications applications. In order to improve device performance in Si photonics, we have developed a Si-Ge-silica monolithic integration platform, on which compact Si-Ge–based modulators/detectors and silica-based high-performance wavelength filters are monolithically integrated. The platform features low-temperature silica film deposition, which cannot damage Si-Ge–based active devices. Using this platform, we have developed various integrated photonic devices for broadband telecommunications applications. 相似文献
8.
The influence of the detailed design of the sidewall region upon the over-all band-broadening in microfabricated packed-bed or collocated monolithic support structure (COMOSS) columns has been investigated using computational fluid dynamics (CFD) simulation techniques. It is shown that, under unretained solute conditions, very small structural variations of the order of only 5% of the particle diameter can give rise to a 4-fold increase of the band-broadening. A comprehensive study has been made to quantify this effect as a function of the fluid velocity, the particle diameter, the channel widths, and of course, the sidewall region design. Because the sidewall effect can be fully attributed to a mismatch between the flow rates in the column center and in the sidewall region, it is fortunately also quite straightforward to avoid it. A very simple design, yielding band-broadening values identical to that of a hypothetical sidewall-less column for all possible values of the flow velocity, the particle diameter, or the channel width is proposed. 相似文献
9.
Villalobos-Hernandez JR Arenas-Hernandez R Villafuerte-Robles L 《Drug development and industrial pharmacy》2001,27(1):39-45
A high-performance liquid chromatographic (HPLC) method for quantification of indorenate admixed of pharmaceutical excipients (Pharmatose DCL 21, Povidone USP and Helmcel 200) is described. Indorenate was extracted from the mixtures using a mobile phase composed of acetonitrile and a sodium acetate buffer solution 0.1 M (63:37) and separated from other dissolved components by ion supression-HPLC. The method was standardized using a C-18 column (250 mm × 4.8 mm, i.d., 5 μm). The photometric detector was fixed at 228 or 272 nm depending on the admixed excipients. Validation parameters included linearity, precision, accuracy, reproducibility, and specificity. The method was specific, selective, and capable to distinguish indorenate from their degradation products and the antihypertensive pelanserine. 相似文献
10.
High-performance lithium battery anodes using silicon nanowires 总被引:7,自引:0,他引:7
There is great interest in developing rechargeable lithium batteries with higher energy capacity and longer cycle life for applications in portable electronic devices, electric vehicles and implantable medical devices. Silicon is an attractive anode material for lithium batteries because it has a low discharge potential and the highest known theoretical charge capacity (4,200 mAh g(-1); ref. 2). Although this is more than ten times higher than existing graphite anodes and much larger than various nitride and oxide materials, silicon anodes have limited applications because silicon's volume changes by 400% upon insertion and extraction of lithium which results in pulverization and capacity fading. Here, we show that silicon nanowire battery electrodes circumvent these issues as they can accommodate large strain without pulverization, provide good electronic contact and conduction, and display short lithium insertion distances. We achieved the theoretical charge capacity for silicon anodes and maintained a discharge capacity close to 75% of this maximum, with little fading during cycling. 相似文献
11.
High-performance genetic analysis on microfabricated capillary array electrophoresis plastic chips fabricated by injection molding 总被引:1,自引:0,他引:1
Dang F Tabata O Kurokawa M Ewis AA Zhang L Yamaoka Y Shinohara S Shinohara Y Ishikawa M Baba Y 《Analytical chemistry》2005,77(7):2140-2146
We have developed a novel technique for mass production of microfabricated capillary array electrophoresis (mu-CAE) plastic chips for high-speed, high-throughput genetic analysis. The mu-CAE chips, containing 10 individual separation channels of 50-microm width, 50-microm depth, and a 100-microm lane-to-lane spacing at the detection region and a sacrificial channel network, were fabricated on a poly(methyl methacrylate) substrate by injection molding and then bonded manually using a pressure-sensitive sealing tape within several seconds at room temperature. The conditions for injection molding and bonding were carefully characterized to yield mu-CAE chips with well-defined channel and injection structures. A CCD camera equipped with an image intensifier was used to monitor simultaneously the separation in a 10-channel array with laser-induced fluorescence detection. High-performance electrophoretic separations of phiX174 HaeIII DNA restriction fragments and PCR products related to the human beta-globin gene and SP-B gene (the surfactant protein B) have been demonstrated on mu-CAE plastic chips using a methylcellulose sieving matrix in individual channels. The current work demonstrated greatly simplified the fabrication process as well as a detection scheme for mu-CAE chips and will bring the low-cost mass production and application of mu-CAE plastic chips for genetic analysis. 相似文献
12.
13.
High-performance liquid chromatography-electrospray ionization mass spectrometry using monolithic capillary columns for proteomic studies 总被引:4,自引:0,他引:4
Premstaller A Oberacher H Walcher W Timperio AM Zolla L Chervet JP Cavusoglu N van Dorsselaer A Huber CG 《Analytical chemistry》2001,73(11):2390-2396
The use of tetrahydrofuran/decanol as porogens for the fabrication of micropellicular poly(styrene/divinylbenzene) monoliths enabled the rapid and highly efficient separation of peptides and proteins by reversed-phase high-performance liquid chromatography (RP-HPLC). In contrast to conventional, granular, porous stationary phases, in which the loading capacity is a function of molecular mass, the loadability of the monoliths both for small peptides and large proteins was within the 0.40.9-pmol range for a 60- x 0.2-mm capillary column. Lower limits of detection obtained by measuring UV-absorbance at 214 nm with a 3-nl capillary detection cell were 500 amol for an octapeptide and 200 amol for ribonuclease A. Upon reduction of the concentration of trifluoroacetic acid in the eluent from the commonly used 0.1-0.2 to 0.05%, the separation system was successfully coupled to electrospray ionization mass spectrometry (ESI-MS) at the cost of only a small decrease in separation efficiency. Detection limits for proteins with ESI-MS were in the lower femtomole range. High-quality mass spectra were extracted from the reconstructed ion chromatograms, from which the masses of both peptides and proteins were deduced at a mass accuracy of 50-150 ppm. The applicability of monolithic column technology in proteomics was demonstrated by the mass fingerprinting of tryptic peptides of bovine catalase and human transferrin and by the analysis of membrane proteins related to the photosystem II antenna complex of higher plants. 相似文献
14.
Rapid, comprehensive two-dimensional gas chromatographic (GC × GC) separations by use of a microfabricated midpoint thermal modulator (μTM) are demonstrated, and the effects of various μTM design and operating parameters on performance are characterized. The two-stage μTM chip consists of two interconnected spiral etched-Si microchannels (4.2 and 2.8 cm long) with a cross section of 250 × 140 μm(2), an anodically bonded Pyrex cap, and a cross-linked wall coating of poly(dimethylsiloxane) (PDMS). Integrated heaters provide rapid, sequential heating of each μTM stage, while a proximate, underlying thermoelectric cooler provides continual cooling. The first-dimension column used for GC × GC separations was a 6 m long, 250 μm i.d. capillary with a PDMS stationary phase, and the second-dimension column was a 0.5 m long, 100 μm i.d. capillary with a poly(ethylene glycol) phase. Using sets of five to seven volatile test compounds (boiling point ≤174 °C), the effects of the minimum (T(min)) and maximum (T(max)) modulation temperature, stage heating lag/offset (O(s)), modulation period (P(M)), and volumetric flow rate (F) on the quality of the separations were evaluated with respect to several performance metrics. Best results were obtained with a T(min) = -20 °C, T(max) = 210 °C, O(s) = 600 ms, P(M) = 6 s, and F = 0.9 mL/min. Replicate modulated peak areas and retention times were reproducible to <5%. A structured nine-component GC × GC chromatogram was produced, and a 21 component separation was achieved in <3 min. The potential for creating portable μGC × μGC systems is discussed. 相似文献
15.
16.
17.
《Materials science & engineering. C, Materials for biological applications》2006,26(5-7):1072-1076
Electrodeposition of polypyrrole film on porous silicon surface was used to improve its photoluminescence properties for sensing of chemical species in gas phase. Photoluminescence quenching sensor response was measured for water and a homological set of linear alcohols in gas phase. We observed modified photoluminescence quenching response from polypyrrole-modified porous silicon as compared with as-prepared porous silicon. For as-prepared porous silicon samples, the dependence of photoluminescence quenching on analyte concentration revealed Stern–Volmer behavior. Concentration dependence of photoluminescence quenching response of polypyrrole-modified samples for water and methanol exhibited Stern–Volmer behavior as well, for C2–C6 linear alcohols a period of photoluminescence enhancement on the concentration dependence onset followed by photoluminescence quenching at higher concentrations was observed. The interval of photoluminescence enhancement response from polypyrrole-modified samples was continuously decreasing with the length of alcohol chain. Dramatic reduction of sensor photoluminescence response to lower alcohols was attributed to strong interaction with polypyrrole surface layer and suppressed analyte penetration into porous matrix. Operational stability of polypyrrole-modified porous silicon was improved as compared to as-prepared porous silicon. 相似文献
18.
We have demonstrated, for the first time, that high-performance liquid chromatography (HPLC) can be interfaced with fluorescence line-narrowing spectroscopy (FLNS) for on-line identification and characterization of analytes. Interfacing centered primarily on the design and construction of a novel liquid helium cryostat that accommodates variable-sized quartz tubes/capillaries suitable for HPLC as well as capillary electrophoresis/electrochromatography. In addition to the high spectral resolution afforded by FLNS, analyzing the separated components at 4.2 K minimizes photodegradation from the excitation source and provides indefinite detection times for signal averaging. The proof-of-principle for the HPLC-FLNS system is first demonstrated with a mixture of four structurally similar polycyclic aromatic hydrocarbons and then applied to the analysis of DNA adducts from mouse skin exposed to the carcinogen dibenzo[a,l]pyrene. With femtomole detection limits, HPLC-FLNS can be used for real-world analyses of complex mixtures. 相似文献
19.
A novel gas chromatography detector is described that uses acoustic signals from a partly premixed hydrogen-air flame burning on top of a capillary. The device, referred to as the acoustic flame detector (AFD), is based on the measurement of the frequency of acoustic transients generated at the burner under a range of operating conditions. The presence of trace amounts of analyte in the flame was found to increase the frequency of these sonic bursts from the baseline level of ~100 Hz. The response of the AFD for n-dodecane, measured as the shift in frequency, was determined to be linear over ~3 orders of magnitude, with a minimum detectable level of about 1-5 ng C/s using the current system. The sensitivity correlates roughly with carbon content, except for certain organometallics (Sn, Mn), which gave substantially enhanced signals. Some tailing was observed but became serious only for particular types of organometallics. The noise of the system was predominantly of the 1/f type. The effects of flow conditions, burner geometry, and flame gas constituents were investigated. The oscillations could be followed by acoustic, visual, electrical, and optical means. The AFD mechanism is shown to involve oscillatory chemical kinetics, in which the flame front (the inner cone) temporarily enters a few millimeters into the capillary during each cycle, thereby creating the acoustic signal. 相似文献
20.