首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BACKGROUND: Gamma irradiation is a safe method for the decontamination of shellfish, and its technical feasibility and safety have been endorsed (FAO/IAEA/WHO). In order to implement proper food‐processing regulations, the identification of radiation treatment is required. In this study, electron paramagnetic resonance (EPR) spectroscopy was employed to identify the irradiation of seven different types of commonly consumed shellfish. RESULTS: Characteristics (g factor and signal intensity) of the EPR spectra of control and irradiated samples were recorded in order to clarify the gamma‐ray treatment of shellfish. Radiation‐specific signals around g = 2.0038 ± 0.0006 (g1) and g = 1.9996 ± 0.0002 (g2 and g3) were observed for all shellfish samples irradiated with absorbed doses of 3 and 6 kGy. The X‐ray diffraction (XRD) spectra of some shellfish samples were recorded to investigate their mineral profiles. CONCLUSION: The EPR spectroscopic results indicated that carbonate minerals were the source of the paramagnetic species that were produced upon irradiation, entrapped in the shellfish and showed radiation‐specific asymmetric signals whose intensities increased quantitatively with the absorbed radiation dose. The XRD analysis revealed that aragonite and calcite minerals were present in the shells of shellfish. Copyright © 2011 Society of Chemical Industry  相似文献   

2.
Confocal microscopy of the corneas of long-term rigid contact lens wearers.   总被引:1,自引:0,他引:1  
Slit scanning confocal microscopy (Tomey Confoscan P4) was used to evaluate the central cornea of 22 subjects who had been wearing rigid lenses on a long-term, daily wear basis. Anterior and posterior keratocyte densities appeared unaffected by rigid lens wear (P = 0.10 and 0.34 for anterior and posterior keratocyte densities, respectively). Subjects with a previous history of polymethyl methacrylate (PMMA) lens wear showed a reduction in anterior keratocyte density (AKD) (P < 0.0001) and an increased level of haze in the anterior stroma. This may represent previous hypoxic damage. Endothelial cell density (ECD) was unaffected by rigid lens wear (P = 0.36) although an increase in endothelial polymegethism was evident (P < 0.0001). Subjects who had only worn rigid lenses with no history of PMMA lens wear did not show an increase in endothelial polymegethism (P = 0.10). An increased number of microdot opacities compared to the non-lens wearing eye was apparent (P = 0.05). The number of microdot opacities induced by rigid lenses, as reported in this study, appears to be less than that reported by others in respect of soft lenses.  相似文献   

3.
PurposeTo examine the annualised waste and end-of-life disposal options with two representative soft contact lens (CL) modalities.MethodsThe component parts of two representative soft CL modalities were catalogued, separated, weighed and inspected for material identification: somofilcon A soft CLs (clariti elite, CooperVision Inc.) used with multi-purpose solution (MPS) (All in one Light, CooperVision Inc.) and somofilcon A CLs (clariti 1 day, CooperVision Inc). Using a model that assumed compliant wear and care of CLs, the mass of material solid waste generated by CL use over a year was calculated. Disposal options were explored using household and specialist recycling streams in order to develop recommendations for responsible disposal of CL waste.ResultsFull-time daily disposable (DD) CL wear generates 1.06 kg of waste annually compared to 0.83 kg generated by reusable-monthly replacement daily wear (‘reusable’) CLs. Plastic was the dominant material in both modalities. With full-time use of DD CLs, 64% of waste by mass was plastic blister trays. For full-time use of reusable CLs, where figures from lens and MPS packaging are combined, plastics accounted for 67% of waste by mass. MPS bottles alone made up almost half the waste (45%) associated with full-time reusable CL wear.ConclusionFull-time DD wear generates 27% more waste annually than full-time reusable lens wear. Reusable CL wearers can recycle 78% of waste at home. DD lens wearers have access to recycling options that allow them to recycle 100% of CL related waste. Full-time CL lens wear represents just 0.20–0.26% of the 412 kg of household waste generated per person, per year in the United Kingdom. Worn CLs should never be disposed of down the sink or lavatory. CL wearers should be aware of responsible end-of-life recycling and disposal options for all CL waste.  相似文献   

4.
5.

Purpose

To evaluate compliance to contact lens use in 14 countries, and to identify wearer attributes which indicate lower compliance levels.

Methods

A web-based survey was undertaken by 4021 contact lens wearers, revealing information about demographics, and lens and solution information including daily handling details, case care and aftercare frequency. Particular attention was paid to eight modifiable compliance-related behaviours which are associated with an increased risk of microbial keratitis.

Results

Full compliance was very rare for most lens users, although better (15% of wearers) for daily disposable lenses. Reduced compliance was demonstrated in South Korea, and for young male full-time contact lens users, especially those who have not consulted their eyecare practitioner for some time. The behaviours associated with the lowest levels of compliance were rubbing and rinsing, handwashing, correct lens replacement and case cleaning.

Conclusions

Given other recent literature, which suggests improved contact lens compliance with regular self-review exercises, we encourage clinical colleagues to particularly examine case cleaning, handwashing and rubbing and rinsing at aftercare examinations, especially in young male wearers.  相似文献   

6.
Ultrafine (<100 nm) ash particles in three coal fly ashes (CFA) produced by the combustion of three U.S. coals have been examined by high-resolution transmission electron microscopy (HRTEM), energy-dispersive X-ray spectroscopy (EDS), and electron diffraction. These ultrafine particles, either as primary ash particles derived directly from coal minerals or as secondary products of decomposition and vaporization-condensation processes, show quite different morphologies, compositions, and microstructures as compared to particles in coarser, micrometer-size fractions previously examined by CCSEM. An eastern U.S. bituminous CFA sample shows abundant discrete crystalline particles rich in Fe, Ti, and Al in its ultrafine ash fraction, and crystalline phases down to 10 nm size have been identified. Western U.S. low-rank CFA samples contain considerable amounts of alkaline-earth element aggregates in the form of phosphates, silicates, and sulfates and mixed species. Most of them show crystalline or crystalline plus amorphous characteristics. All three ultrafine samples also exhibit carbonaceous particles in the form of soot aggregates with primary particle size typically between 20 and 50 nm. In the western low-rank ultrafine CFAs, these carbonaceous soot particles were typically mixed or coated with multi-element inorganic species.  相似文献   

7.
8.
To assess the demographics of UK contact lens prescribing, data gathered from annual contact lens fitting surveys conducted over the past 12 years were mined for clinically useful information. Significant gender differences in age, lens design, wearing modality and wearing frequency are putatively explained in terms of cosmetic and lifestyle factors.  相似文献   

9.
There has been little published on the presence of deposits on disposable hydrogel contact lenses. The purpose of the present study was to determine the possible existence of such deposits. Seventy-two disposable lenses (polymacon; FDA group 1; non-ionic, low water contact lenses) were fitted to six patients and replaced weekly in the course of a total follow-up period of six weeks. By means of biomicroscopy, light microscopy and scanning electron microscopy, different types of deposits were observed on all the lenses studied. Our results also indicate that the accumulation rate of these deposits expressed as a percentage of the total area of the lens which they covered increased after the third replacement of the lenses over the 4th, 5th and 6th weeks. Finally, we observed that the amount of deposits varies in the different patients studied in the course of a 6 week follow-up period.  相似文献   

10.
In this paper the effect of two pre-treatment methods are compared experimentally for the filtration of (i) a spent sulphite liquor (17.8 wt.% dry solids) using a 20 kg mol−1 molar mass cut off (MMCO) fluoropolymer membrane and (ii) a molasses solution (45° Brix) using a polysulphone (Psf) membrane (1.5 μm pore size). Both feeds are industrially relevant, and subject to severe fouling issues when membranes are used in their subsequent processing. The pre-treatment methods evaluated were: (i) conditioning with water at 60 °C only [Protocol 1], and (ii) conditioning with water at 60 °C followed by cleaning with 0.5 wt.% NaOH [Protocol 2]. Results are presented that confirm the benefits of sodium hydroxide preconditioning upon performance, supporting the suggestion by some membrane manufacturers that this step be included as part of the pre-treatment protocol.  相似文献   

11.
The purpose of this study was to investigate the effect of the Bruder Moist Heat Compress on contact lens (CL) discomfort in subjects with contact lens-related dry eye (CLDE). This was a 4-week, single-center, three-arm, randomized, open-label clinical trial in subjects diagnosed with CLDE using the Contact Lens Dry Eye Questionnaire. Fifty-one CL wearers were randomized to one of three treatment groups: application of the Bruder Compress twice a day, Bruder Compress once a day, or warm washcloth used for ten minutes twice a day without reheating. Subject diaries were monitored for compliance and collected data on daily CL comfort upon awakening and throughout the afternoon. Clinical assessments included tear film break-up time (TBUT), lipid layer thickness (LLT), and meibomian gland evaluation. Statistical tests included a generalized linear model and one-way analysis of variance (ANOVA) to investigate treatment effect on comfortable wear time.Fifty-one subjects (98% female) completed the study. After treatment, subjects using a washcloth reported more uncomfortable contact lens wear time on average (mean = 5.1 ± 2.8 h) when compared with subjects who had used the Bruder Compress in Group 1 (mean = 2.8 ± 1.6 h) (p = 0.02). In the Bruder Compress groups, there was a significant reduction in the blockage of meibomian glands (p < 0.01). No significant difference in uncomfortable wear time was found between subjects using the Bruder Compress twice daily versus once daily (p = 0.48). Subjects using the Bruder Compress once daily had the highest rate of compliance at 90.2% (p < 0.01). No significant improvements were observed in TBUT (p = 0.76) or LLT (p = 0.78).The Bruder Moist Heat Compress resulted in a significant improvement in comfortable CL wear time in subjects with CLDE.  相似文献   

12.

Purpose

To evaluate whether LipidTOX could stain lipid deposits on contact lens (CL) surfaces and compare lipid deposition patterns on various CL surfaces using an imaging method.

Methods

Ten CLs each of six silicone hydrogel materials and one hydrogel material were incubated in cholesteryl oleate solution (5.60 mg/ml) for 12 hours. The CLs were then separately stained with Oil Red O and LipidTOX and imaged under a fluorescence microscope. Twenty worn senofilcon A CLs from both eyes of ten participants were also stained similarly. The area of deposition was calculated using Fiji software. Median deposition areas were compared between various materials using the Kruskal-Wallis test. The Mann-Whitney U test was used to compare the median deposition areas in the same material using the two dyes and also to compare the median deposition areas on worn and doped senofilcon A CLs.

Results

LipidTOX staining needed fewer steps than Oil Red O for staining the deposits. There was no statistically significant difference between the median areas of lipid deposition among the CL materials using either Oil Red O (p = 0.42) or LipidTOX (p = 0.21). However, significantly different median deposition areas were found between in vitro and ex vivo stained senofilcon A CLs using both Oil Red O (p = 0.002) and LipidTOX (p = 0.029).

Conclusions

LipidTOX can stain lipid deposits on contact lens surfaces and is simpler to use than Oil Red O. Lipid deposition in the central 2 mm diameter zone did not significantly differ between various commercial CL materials.  相似文献   

13.
Water properties of soft contact lens materials.   总被引:3,自引:0,他引:3  
The properties of water in soft contact lenses such as the water content, free-to-bound water ratio, and the extent to which soft lenses dehydrate during wear, are key determinants of their in eye performance and oxygen transmissibility characteristics. This study describes clinical and laboratory experiments that were conducted in order to examine the state of water in eight soft contact lenses manufactured from different materials. Specifically, lenses made from the following eight materials (and nominal water contents) were used: HEMA/VP 40%, HEMA/VP 55%, HEMA/VP 70%, VP/MMA 55%, VP/MMA 70%, HEMA 40%, HEMA/MAA 55% and HEMA/MAA 70% [HEMA = 2-hydroxy-ethyl methacrylate, VP = vinyl pyrrolidone, MMA = methyl methacrylate, MAA = methacrylic acid]. Differential scanning calorimetry (DSC) was used for measuring the free water content in the materials listed above. Some noticeable differences in water properties among soft contact lens materials having approximately the same water contents were revealed. Low water content materials exhibited a simple endotherm and all water melted around 0 degrees C. On the other hand, medium and high water content materials exhibited multiple melting endotherms, representing a broad range of interactions between water and the polymer. Low water content soft contact lenses have approximately the same amount of bound water as those with much higher water contents. Six subjects were then fitted with the same lenses for one day. In vitro measurements of water content and oxygen transmissibility were taken at 35 degrees C, both before lens fitting and after 6 h of lens wear. Water content and oxygen transmissibility were correlated with the water properties of the soft contact lens materials. The relative change in lens water content (%deltaWC) and relative change in lens oxygen transmissibility (%deltaDk/t) were calculated and correlated with the water properties of the eight soft contact lens materials. It was concluded that (a) oxygen transmissibility, free water content and free-to-bound water ratio are increased when the water content of a contact lens is increased and (b) water content, free water content and free-to-bound water ratio cannot be used for the prediction of soft contact lens dehydration in vivo.  相似文献   

14.
The removal of rigid contact lenses from the eye, using the eyelids, is a relatively simple procedure. However, there is a sequence of biomechanical events underlying this procedure which are not well understood. By using high-speed videokeratoscopy (50 Hz), we have shown that during the lid-pull procedure the cornea typically shows a significant increase in with-the-rule astigmatism by an average of 2.19 D (axial power). The average increase in steep K power was 1.22 D (S.D. +/-1.05 D) and the average decrease in flat K power was 0.97 D (S.D. +/-1.05 D). This change in corneal topography increases the edge lift of the lens at 12 and 6 O'clock locations of the lens, enhancing the removal process. When the subject blinks, as the lid margins reach the lens edge, the lens flexes and the eye retracts by an average of 0.66 mm (S.D. +/-0.27 mm). This retraction again enhances the act of lens removal.  相似文献   

15.
Contact lenses can induce changes in the epithelium, stroma and endothelium of the cornea, all of which can be observed clinically using the slit-lamp biomicroscope. These complications include epithelial microcysts, vacuoles and staining, stromal oedema and vascularization, and endothelial polymegethism and blebs. Each complication can be attributed to one or more aetiological factors such as hypoxia, hypercapnia, tissue acidosis, trauma, hypersensitivity and toxicity. This review outlines the way in which these complications manifest clinically, and consideration is given to management strategies and likely prognoses. Early detection of these conditions and appropriate action can usually prevent more serious ocular complications.  相似文献   

16.
A simple hand-held refractometer was used to measure the refractive index of 27 rigid gas permeable contact lens materials. As a general rule, lenses with refractive indices lower than 1.458 are made from fluorosilicone acrylates; lenses with refractive indices in the range of 1.458 to 1.469 are made from either fluorosilicone acrylates or silicone acrylates; and lenses with refractive indices greater than 1.469 are made from silicone acrylates. It is demonstrated how refractometry can be used by contact lens practitioners for the identification and verification of rigid contact lenses.  相似文献   

17.
Contact lens deposits have been reported previously with extended wear of soft contact lenses, with proteins, lipids, mucous, and various salts such as chloride, potassium and calcium being deposited on the lens surface [1]. We report an unusual case of precipitates on the surface of a bandage contact lens (BCL) following intensive treatment with topical preservative free artificial tears. Evaluation included microscopic and histochemical analysis of the BCL. We have also reviewed the literature for previous reports of contact lens precipitates.  相似文献   

18.
The strength of contact lens materials is an important consideration with respect to resistance to damage during lens handling and long term durability, and may govern some aspects of in-eye lens performance. The tensile properties of hydrogel contact lenses manufactured from eight different materials were examined in a series of clinical and laboratory experiments using the Instron 1122 Universal Testing Instrument. Lenses from the following eight materials (and nominal water contents) were used: HEMA/VP 40%, HEMA/VP 55%, HEMA/VP 70%, VP/MMA 55%, VP/MMA 70%, HEMA 40%, HEMA/MAA 55% and HEMA/MAA 70% (HEMA: 2-hydroxy-ethyl methacrylate, VP: vinyl pyrrolidone, MMA: methyl methacrylate, MAA: methacrylic acid). Tensile strength, elongation-at-break and Young's modulus were measured. A technique was devised that enables three parallel-sided specimens of identical width to be cut from a single contact lens with good accuracy. It was found that materials made from HEMA/MAA--although having a very low tensile strength and elongation-at-break--exhibit only a moderate Young's modulus. Materials made from HEMA/VP exhibit high-to-moderate tensile strength, high elongation-at-break and moderate-to-low Young's modulus. Materials made from VP/MMA exhibit high tensile strength and high-to-moderate elongation-at-break, but the Young's modulus is high for the 55% water content and low for the 70% water content materials. The HEMA 40% material exhibits a moderate tensile strength, a low elongation-at-break and a high Young's modulus. This experiment highlights the necessity of developing an accepted standard test methodology for contact lens material stiffness evaluation, in order to derive useful comparative information. Six subjects were fitted with the same lenses for one day. In vitro measurements of total diameter and back optic zone radius were taken at 35 degrees C before lens fitting and after 6h of lens wear. Lens water content, the relative change in lens total diameter (%deltaTD) and relative change in lens back optic zone radius (%deltaBOZR) were calculated and correlated with the tensile properties of the eight hydrogel lens materials. It is concluded that hydrogel materials with high stiffness and strength display less tendency to change their geometric parameters and materials with a high water content do not necessarily have the weakest mechanical properties.  相似文献   

19.
IntroductionAccurate corneal measurements are crucial in corneal refractive surgery (CRS) to ensure successful outcomes. Soft contact lens (SCL) wear may result in changes to corneal curvature and structure. United States Food and Drug Administration (FDA) pre-operative guidelines recommend that prior to CRS, SCL wearers cease SCL wear for “at least two weeks before examination and treatment” [1]. Corneal curvature changes induced by SCL wear may take longer than two weeks to resolve.PurposeTo examine the effect of SCL wear on corneal curvature before and following two weeks SCL wear cessation. To explore the possible impact of different SCL materials and years of SCL wear.MethodsRetrospective data analysis, between a group of SCL wearers (SCL: n = 45); and a non-contact lens control group (NCL: n = 45). Corneal curvature parameters were measured using the Pentacam (Oculus, Germany), before and following two weeks cessation of SCL wear.ResultsNo significant differences in keratometry or Sagittal radius of curvature between SCL and NCL groups prior to or following SCL cessation. Tangential radius of curvature showed significant inferior steepening for the SCL group prior to SCL cessation (SCL vs. NCL; 7.77 ± 0.30 mm vs. 7.90 ± 0.30 mm; p = 0.04). Following two weeks cessation of SCL wear this appeared to have resolved.ConclusionsTwo weeks cessation of SCL wear appears sufficient for resolution of corneal curvature changes with modern SCL materials and years of SCL wear. However, further studies with longer lens deprivation periods are required to ensure stability for all SCL wearing patients.  相似文献   

20.
PurposeUsing atomic force microscopy (AFM) to investigate anterior surface topography (AST) in worn and unworn, plasma surface-treated (PST) and untreated (UT) gas permeable (GP) lenses, and influence of surface topography on in vivo comfort.MethodsGP lens AST evaluated with AFM in tapping mode, using an uncoated, 40 nm symmetric tip (sampling frequency: 300 kHz), at five randomised locations, over a 100μm2 area, to produce mean average roughness (Ra) and root mean square (RMS) values for each sample. Four unworn lenses (two PST, two UT) were examined (Quasar/Boston EO material). Twenty worn lenses (ten PST, ten UT) of same design and material as unworn lenses collected after 3 months lens wear. General wearing comfort reported by visual analogue scale (VAS) at 3 months visit. For sample preparation, two worn UT GP lenses were divided into four segments; each segment underwent a different lens rinse and drying method.ResultsUnworn: UT lenses had significantly higher mean RMS and Ra values compared to PST (Mann-Whitney, p < 0.05). Worn: UT Median RMS values were significantly higher than PST (Mann-Whitney, p < 0.05). Comfort: no correlation found between general comfort and RMS or Ra scores. Sample preparation: Method 4 (purified, distilled water rinse/nitrogen gas dry) produced optimum median RMS and Ra values.ConclusionsUnworn PST GP lenses had lower Ra and RMS values compared with unworn UT GP lenses. After 3 months wear, PST lenses had smoother surface topographies than UT lenses. No relationship was found between surface topography and lens wear comfort. Sample preparation protocol directly impacts AFM results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号