 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method producing simultaneously three retention indexes for compounds has been developed for comprehensive two-dimensional gas chromatography by using a dual secondary column approach (GC x 2GC). For this purpose, the primary flow of the first dimension column was equally diverted into two secondary microbore columns of identical geometry by means of a three-way flow splitter positioned after the longitudinally modulated cryogenic system. This configuration produced a pair of comprehensive two-dimensional chromatograms and generated retention data on three different stationary phases in a single run. First dimension retention indexes were determined on a polar SolGel-Wax column under linear programmed-temperature conditions according to the van den Dool approach using primary alcohol homologues as the reference scale. Calculation of pseudoisothermal retention indexes in both second dimensions was performed on low-polarity 5% phenyl equivalent polysilphenylene/siloxane (BPX5) and 14% cyanopropylphenyl/86% dimethylpolysiloxane (BP10) columns. To construct a retention correlation map in the second dimension separation space upon which KovAts indexes can be derived, two methods exploiting "isovolatility" relationships of alkanes were developed. The first involved 15 sequential headspace samplings of selected n-alkanes by solid-phase microextraction (SPME), with each sampling followed by their injection into the GC at predetermined times during the chromatographic run. The second method extended the second dimension retention map and consisted of repetitive introduction of SPME-sampled alkane mixtures at various isothermal conditions incremented over the temperature program range. Calculated second dimension retention indexes were compared with experimental values obtained in conventional one-dimensional GC. A case study mixture including 24 suspected allergens (i.e., fragrance ingredients) was used to demonstrate the feasibility and potential of retention index information in comprehensive 2D-GC.  相似文献   

2.
In a comprehensive two-dimensional gas chromatograph, a thermal modulator serially couples two columns containing dissimilar stationary phases. The secondary column generates a series of high-speed secondary chromatograms from the sample stream formed by the chromatogram eluting from the primary column. This series of secondary chromatograms forms a two-dimensional gas chromatogram with peaks dispersed over a retention plane rather than along a line. The method is comprehensive because the entire primary column chromatogram is transmitted through the secondary column with fidelity. One might expect that a two-dimensional separation in which both dimensions are basically the same technique, gas chromatography, would be inefficient because the two dimensions would behave similarly, generating peaks whose retentions correlate across dimensions. Applying a temperature program to the two columns, however, can tune the separation to eliminate this inefficiency. The temperature program reduces the retentive power of the secondary column as a function of progress of the primary chromatogram such that the retention mechanism of the primary column is eliminated from the second dimension. Retention of a substance in the second dimension is then determined by the difference in its interaction with the two stationary phases. Retention times in the second dimension then fall within a fixed range, and the whole retention plane is accessible. In a properly tuned comprehensive two-dimensional chromatogram, retention times in the two dimensions are independent of each other, and the two-dimensional chromatogram is orthogonal. Orthogonality is important for two reasons. First, an orthogonal separation efficiently uses the separation space and so has either greater speed or peak capacity than nonorthogonal separations. Second, retention in the two dimensions of an orthogonal chromatogram is determined by two different and independent mechanisms and so provides two independent measures of molecular properties.  相似文献   

3.
A novel hybrid (sequential) comprehensive 2D-multidimensional gas chromatography (GC × GC-MDGC) method for complex sample manipulation and separation is described. It incorporates a separation step that approximates slow modulation GC × GC, prior to microfluidic Deans switch heart-cutting of a targeted region(s) into a third analytical column. It allows discrete single or multiple components, bands or regions, or any combination of these to be selected and excised from within the 2D GC × GC separation space. The excised individual components can be further collected and studied. Alternatively, any unresolved or poorly resolved components, or regions that require further separation, can be transferred to an additional (third) column separation step. The method is applied to separation and quantitative analysis of oxygenates in a thermally stressed algae-derived biofuel oil by using flame ionization detection (FID), without any prefractionation. This permits oxygenated compounds to be fully resolved from saturated (matrix) compounds, which are completely excluded from the third column. Improved separation was obtained between target classes (aldehydes, 2-ketones, alcohols, acids). Excellent calibration linearity, and retention time and peak area reproducibility were obtained for 14 oxy-compounds present in trace amount in the complex biofuel matrix. Accuracy of microfluidic transfer to the third column, and the profile reproducibility before and after heart-cut operations, was demonstrated by extracting single components from a complex coffee volatile sample.  相似文献   

4.
A pressure-tunable series-coupled ensemble of two capillary GC columns is combined with a time-of-flight MS detector for the high-speed characterization of mixtures containing hydrocarbon compounds. The column ensemble consists of a nonpolar 5% phenyl poly(dimethylsiloxane) column and a very polar poly(ethylene glycol) column. The TOFMS instrument uses time-array detection to obtain up to 500 complete electron mass spectra per second. Instrument software allows for automated peak finding and the spectral deconvolution of severely overlapping unknown chromatographic peaks, if their fragmentation patterns are significantly different and if at least two spectra can be recorded between the peak apexes. By adjusting the carrier-gas pressure at the column-junction point, the separations between adjacent peak pairs can be adjusted to enhance the capabilities of the TOFMS detector. The sensitivity of peak-pair separation to changes in junction-point pressure is studied for combinations of alkanes, olefins, and aromatic compounds. When complete separation is required, the use of pressure-tunable column ensembles cannot always provide sufficient control of peak-pair separation for structurally similar compounds. However, complete chromatographic separation typically is not required with the TOFMS detection, and a pressure-tunable column ensemble is very useful for the high-speed characterization of hydrocarbon mixtures.  相似文献   

5.
本文合成了十二烷基苯磺酸钾色谱固定相,并制备了毛细管色谱柱,研究了其柱性能和分离能力。实验表明,十二烷基苯磺酸钾色谱固定相对烷烃、芳香烃、酯类、醇类等具有较强的选择分离能力,制成的毛细管柱具有较高的柱效,有很高的实用价值。  相似文献   

6.
A porous layer open tubular (PLOT) silica gel column was used together with subcritical CO2 as the mobile phase to effect the group separation of polar oxygenated compounds. Aliphatic and aromatic compounds were shown to elute together. This group was followed by ethers and aldehydes, which were separated from compounds containing an alcohol functional group. Compounds with a carboxylic acid moiety could also be eluted from the silica gel. The group separation obtained when a silica gel PLOT column is used together with subcritical CO2 was also demonstrated to be valuable as the first dimension of a comprehensive two-dimensional SFCxGC analysis where the GC analysis in the second dimension is performed with a fast and independently heated temperature programmed gas chromatograph. With this combination of SFC and GC, many of the oxygenated compounds, routinely found in petroleum samples, could successfully be separated and identified.  相似文献   

7.
This work describes the realization of rapid switching between hard electron ionization (EI) and soft single-photon ionization (SPI) integrated in a compact orthogonal acceleration time-of-flight mass spectrometer. Vacuum-ultraviolet (VUV) photons of 9.8 eV (126 nm) emitted from the innovative electron-beam-pumped rare-gas excimer light source (EBEL) filled with argon are focused into the ion chamber by an ellipsoidal mirror optic for accomplishing of SPI. This novel orthogonal acceleration time-of-flight mass spectrometer with switching capability was hyphenated to one-dimensional gas chromatography (GC) and comprehensive two-dimensional (2D) gas chromatography (GC × GC) for the first time. Within this demonstration study, a maximum switching frequency of 80 Hz was applied for investigation of a mineral-oil-type diesel sample. This approach allows the quasi-simultaneous acquisition of complementary information about the fragmentation pattern (EI) as well as the molecular mass (SPI) of compounds within a single analysis. Furthermore, by application of a polar GC column for separation, the SPI data can be displayed in a 2D contour plot, leading to a comprehensive 2D characterization (GC × MS), whereas the typical group-type assignment for diesel is also met.  相似文献   

8.
Rapid, comprehensive two-dimensional gas chromatographic (GC × GC) separations by use of a microfabricated midpoint thermal modulator (μTM) are demonstrated, and the effects of various μTM design and operating parameters on performance are characterized. The two-stage μTM chip consists of two interconnected spiral etched-Si microchannels (4.2 and 2.8 cm long) with a cross section of 250 × 140 μm(2), an anodically bonded Pyrex cap, and a cross-linked wall coating of poly(dimethylsiloxane) (PDMS). Integrated heaters provide rapid, sequential heating of each μTM stage, while a proximate, underlying thermoelectric cooler provides continual cooling. The first-dimension column used for GC × GC separations was a 6 m long, 250 μm i.d. capillary with a PDMS stationary phase, and the second-dimension column was a 0.5 m long, 100 μm i.d. capillary with a poly(ethylene glycol) phase. Using sets of five to seven volatile test compounds (boiling point ≤174 °C), the effects of the minimum (T(min)) and maximum (T(max)) modulation temperature, stage heating lag/offset (O(s)), modulation period (P(M)), and volumetric flow rate (F) on the quality of the separations were evaluated with respect to several performance metrics. Best results were obtained with a T(min) = -20 °C, T(max) = 210 °C, O(s) = 600 ms, P(M) = 6 s, and F = 0.9 mL/min. Replicate modulated peak areas and retention times were reproducible to <5%. A structured nine-component GC × GC chromatogram was produced, and a 21 component separation was achieved in <3 min. The potential for creating portable μGC × μGC systems is discussed.  相似文献   

9.
A new instrumental approach for collection of retention index data in the first (1D) and second (2D) dimensions of a comprehensive two-dimensional (2D) gas chromatography (GCxGC) experiment has been developed. First-dimension indexes were determined under conventional linear programmed temperature conditions (Van den Dool indexes). To remove the effect that the short secondary column imposes on derived 1D indexes, as well as to avoid handling of pulsed GCxGC peaks, the proposed approach uses a flow splitter to divert part of the primary column flow to a supplementary detector to simultaneously generate a conventional 1D chromatogram, along with the GCxGC chromatogram. The critical 2D indexes (KovAts indexes) are based upon isovolatility curves of normal alkanes in 2D space, providing a reference scale against which to correlate each individual target peak throughout the entire GCxGC run. This requires the alkanes to bracket the analytes in order to allow retention interpolation. Exponential curves produced in the 2D separation space require a novel approach for delivery of alkane standards into the 2D column by using careful solvent-free solid-phase microextraction (SPME) sampling. Sequential introduction of alkane mixtures during GCxGC runs was performed by thermal desorption in a second injector which was directly coupled through a short transfer line to the entrance of the secondary column, just prior to the modulator so that they do not have to travel through the 1D column. Thus, each alkane mixture injection was quantitatively focused by the cryogenic trap, then launched at predetermined times onto the 2D column. The system permitted construction of an alkane retention map upon which bidimensional indexes of a 25-perfume ingredient mixture could be derived. Comparison of results with indexes determined in temperature-variable one-dimensional (1D) GC showed good correlation. Plotting of the separation power in the second dimension was possible by mapping Trennzahl values throughout the 2D space. The methodology was applied to the separation of a standard mixture composed of 25 analytes (very diverse in polarity and structure) suspected to be allergens in perfume samples. The method will allow straightforward determination of temperature-variable retention indexes of target analytes.  相似文献   

10.
A method for carrying out 2D gel electrophoresis in a capillary format is presented. In this method, separation in the first dimension is carried out in a 1D capillary, with this system physically isolated from the capillaries that provide the separation in the second dimension. After completion of the first separation, the 1D channel is physically connected to the 2D capillaries, and a second separation is carried out in an orthogonal set of parallel capillaries. The ability of poly(dimethylsiloxane) (PDMS) to support the fabrication of 3D microfluidic systems makes it possible to produce membranes that both enclose the gel used in the first separation in a capillary and provide passages for the proteins to migrate into the array of orthogonal capillaries. The elastomeric nature of PDMS makes it possible to make reversible connections between pieces of PDMS. The feasibility of this system is demonstrated using a protein mixture containing fluorescein-conjugated carbonic anhydrase, fluorescein-conjugated BSA, and Texas Red-conjugated ovalbumin. This work suggests one type of design that might form the basis for a microfabricated device for 2D capillary electrophoresis.  相似文献   

11.
LC-MS-based shotgun proteomics relies both on the power of the separation techniques and the sensitivity of detection methods. As a viable alternative to classical approaches in this field, we developed a fully automated, comprehensive 2D LC system, in which RPLC × RPLC was coupled to MS detection, for the first time, and applied for the analysis of tryptic digests obtained from α-casein and dephosphorylated α-casein. The use of a significantly different pH in the two dimensions allowed us to attain high peak capacity, despite the employment of novel identical stationary phases. Furthermore, such a combination addresses compatibility issues, thus allowing straightforward interfacing in online 2D LC configuration, as well as direct linkage to a mass spectrometer. A theoretical peak capacity of ca. 8500 was calculated for the setup, employing four serially coupled C18 columns in the first dimension (600 × 2.1 mm, 2.7 μm d.p.), operated under basic conditions, and 3 cm length of the same stationary phase (30 × 4.6 mm, 2.7 μm d.p. column), under acidic conditions, for fast second dimension analysis.  相似文献   

12.
Single-walled carbon nanotubes used as stationary phase in GC   总被引:1,自引:0,他引:1  
Yuan LM  Ren CX  Li L  Ai P  Yan ZH  Zi M  Li ZY 《Analytical chemistry》2006,78(18):6384-6390
Single-walled carbon nanotubes (SWNTs) have high surface area, high adsorption ability, and nanoscale interactions. In this study, capillary columns including SWNTs, ionic liquid (IL), and IL + SWNTs for GC were prepared. The separation results showed that SWNTs possessed a wide selectivity toward alkanes, alcohols, aromatic compounds, and ketones, and a SWNT capillary column was a very useful GC column for the separation of gas samples. Coating the IL stationary phase on the SWNT capillary column, the SWNTs were able to improve chromatographic characteristic of ionic liquid. Comparing the IL coated on three graphite carbon black capillary columns, which were prepared by dynamic coating, static coating, and chemical bonding the Carbopack C with on SWNTs capillary column, the capacity factors were much higher on the SWNT column. The SEM showed that SWNTs could be bonded to the inner surface of capillary tubing, and most of them were linked end-to-end to form a layer of network structure of skeletons resulting in a high surface area, which increased the interactions between stationary phase and analytes. This is the first single-wall carbon nanotubes bonded to the fused-silica capillary tubing. In the first approach, SWNTs assist ionic liquid with enhanced chromatographic characteristic in GC. This work indicates that SWNTs make it possible to extend the application range on the newly prepared chromatographic stationary phases for GC.  相似文献   

13.
The use of flow splitters between the two dimensions in online comprehensive two-dimensional (2D) liquid chromatography (LC × LC) has not received very much attention, in comparison with their use in 2D gas chromatography (GC × GC), where they are quite common. In principle, splitting the flow after the first dimension column and performing online LC × LC on this constant fraction of the first dimension effluent should allow the two dimensions to be optimized almost independently. When there is no flow splitting, any change in the first-dimension flow rate has an immediate impact on the second dimension. With a flow splitter, one could, for example, double the flow rate into the first dimension column and perform a 1:1 flow split without changing the sample loop size or the sampler's collection time. Of course, the sensitivity would be diminished, but this can be partially compensated through the use of a larger injection; this will likely only amount to a small price to pay for this increased resolving power and system flexibility. Among other benefits, we found a 2-fold increase in the corrected 2D peak capacity and the number of observed peaks for a 15-min analysis time, using a post-first-dimension flow splitter. At a fixed analysis time, this improvement results primarily from an increase in the gradient time, resulting from the reduced system re-equilibration time, and, to a smaller extent, it is due to the increased peak capacity achieved by full optimization of the first dimension.  相似文献   

14.
Sol-gel capillary microextraction (sol-gel CME) is introduced as a viable solventless extraction technique for the preconcentration of trace analytes. To our knowledge, this is the first report on the use of sol-gel-coated capillaries in analytical microextraction. Sol-gel-coated capillaries were employed for the extraction and preconcentration of a wide variety of polar and nonpolar analytes. Two different types of sol-gel coatings were used for extraction: sol-gel poly(dimethylsiloxane) (PDMS) and sol-gel poly(ethylene glycol) (PEG). An in-house-assembled gravity-fed sample dispensing unit was used to perform the extraction. The analysis of the extracted analytes was performed by gas chromatography (GC). The extracted analytes were transferred to the GC column via thermal desorption. For this, the capillary with the extracted analytes was connected to the inlet end of the GC column using a two-way press-fit fused-silica connector housed inside the GC injection port. Desorption of the analytes from the extraction capillary was performed by rapid temperature programming (at 100 degrees C/min) of the GC injection port. The desorbed analytes were transported down the system by the helium flow and further focused at the inlet end of the GC column maintained at 30 degrees C. Sol-gel PDMS capillaries were used for the extraction of nonpolar and moderately polar compounds (polycyclic aromatic hydrocarbons, aldehydes, ketones), while sol-gel PEG capillaries were used for the extraction of polar compounds (alcohols, phenols, amines). The technique is characterized by excellent reproducibility. For both polar and nonpolar analytes, the run-to-run and capillary-to-capillary RSD values for GC peak areas remained under 6% and 4%, respectively. The technique also demonstrated excellent extraction sensitivity. Parts per quadrillion level detection limits were achieved by coupling sol-gel CME with GC-FID. The use of thicker sol-gel coatings and longer capillary segments of larger diameter (or capillaries with sol-gel monolithic beds) should lead to further enhancement of the extraction sensitivity.  相似文献   

15.
A detailed, molecular-level understanding of the retention mechanism in reversed-phase liquid chromatography (RPLC) has eluded analytical chemists for decades. Through validated, particle-based Monte Carlo simulations of a model RPLC system consisting of dimethyloctadecylsilanes at a coverage of 2.9 micro mol/m2 on an explicit silica substrate with unprotected residual silanols in contact with a water/methanol mobile phase, we show that the molecular-level retention processes for nonpolar and polar analytes, such as alkanes and alcohols, are much more complex than what has been previously deduced from thermodynamic and theoretical arguments. In contrast to some previous assumptions, the simulations indicate that both partitioning and adsorption play a key role in the separation process and that the stationary phase in RPLC behaves substantially different from a bulk hydrocarbon phase. The retention of nonpolar methylene segments is dominated by lipophilic interactions with the retentive phase, while solvophilic interactions are more important for the retention of the polar hydroxyl group.  相似文献   

16.
A new class of hydrophilic, relatively polar liquid, cyclodextrin (CD) derivatives have been used as highly selective chiral stationary phases (CSPs) for capillary gas chromatography (GC). Several possible requirements for liquidity in CD derivatives are discussed. O-(S)-2-Hydroxypropyl derivatives of alpha-, beta-, and gamma-cyclodextrins were synthesized, exclusively characterized, permethylated, and evaluated for enantioselectivity. Seventy pairs of enantiomers were resolved. They represent a wide variety of structural types and classes of compounds including chiral alkyl amines, amino alcohols, epoxides, pyrans, furans, sugars, diols, esters, ketones, bicyclic compounds, alcohols, and so on. Many of these compounds were not aromatic and cannot be resolved on any known liquid chromatographic CSP. Often, these enantiomers had far less functionality than required for LC separation. General properties of these CSPs as well as possible insights into the separation mechanism are discussed.  相似文献   

17.
We report on a proof-of-principle experiment with a novel thermal modulation device with potential use in two-dimensional liquid chromatography (LC × LC) systems. It is based on the thermal desorption concept used in two-dimensional gas chromatography (GC × GC) systems. Preconcentration of neutral analytes eluting from the first dimension column is performed in a capillary "trap" column packed with highly retentive porous graphitic carbon particles, placed in an aluminum low-thermal-mass LC heating sleeve. Remobilization of the trapped analytes is achieved by rapidly heating the trap column, by applying temperature ramps up to +1200 °C/min. Compared to the nonmodulated signal, the presented thermal modulator yielded narrow peaks, and a concentration enhancement factor up to 18 was achieved. With a thermally modulated LC separation of an epoxy resin, it is shown that when the thermal modulation is applied periodically, the trapped and concentrated molecules can be released periodically and that the modulating interface can both serve as a preconcentration device and as an injector for the second dimension column of an LC × LC setup. Because of the thermal modulation, a high-molecular-weight epoxy resin could be adequately separated and the different fractions were identified with a GPC analysis, as well as an offline second dimension LC analysis.  相似文献   

18.
Synthetic polymer filaments have been introduced as the support material in packed capillary gas chromatography (GC). The filaments of the heat-resistant polymers, Zylon, Kevlar, Nomex, and Technora, were longitudinally packed into a short fused-silica capillary, followed by the conventional coating process for open-tubular GC columns. The separation of several test mixtures such as n-alkylbenzenes and n-alkanes was carried out with these polymer-coated fiber-packed capillary columns. With the coating by various polymeric materials on the surface of these filaments, the retentivity was significantly improved over the parent fiber-packed column (without polymer coating) as well as a conventional open-tubular capillary of the same length. The results demonstrated a good combination of Zylon as the support and poly(dimethylsiloxane)-based materials as the coating liquid-phase for the successful GC separation of n-alkanes and polycyclic aromatic hydrocarbons (PAHs), while successful applications for other separations such as poly(ethylene glycol) coating for the separation of alcohols were also obtained. From the results it has been suggested that the selectivity of the fiber-packed column could be tuned by selecting different coating materials, indicating the promising possibility for a novel usage of fine fibrous polymers as the support material that can be combined with newly synthesized coating materials specially designed for particular separations. Taking advantage of good thermal stability of the fibers, the column temperature could be elevated to higher than 350 degrees C with the combination of a short metallic capillary.  相似文献   

19.
A new method is described that allows fast target analysis in multidimensional gas chromatography by using a microswitching valve between two GC columns, with cryogenic trapping and rapid re-injection of trapped solutes in the second dimension. The essence of the procedure is that heart-cut fractions from the first column (1D) can be selectively transferred to column 2 (2D), where a moveable cryogenic trap first focuses the transferred solute(s) at the head of the second column and then permits their facile rapid analysis on 2D. Since 2D is a short narrow-bore column, which exhibits very fast analysis (on the order of a few seconds elution), peak responses (heights) are significantly enhanced (by up to 40-fold). Additionally, by using a 2D phase of a selectivity different from that used for 1D, it is possible to also separate components that are not resolved on the first column and to increase the resolution for other compounds. The heart-cut valve isolates the section(s) of solutes of interest from the first column separation, and this provides a considerable simplification to the chromatogram-in addition to the separation and sensitivity advantages. By using this method, multidimensional gas chromatography with multiple heart-cuts can be completed within the same time as the primary column separation. Since the described method permits non-heart-cut fractions to be transferred to a monitor detector, normal detection of these fractions is still permitted. By modulation of the cryotrap, it is also possible to achieve comprehensive two-dimensional gas chromatography for the heart-cut fractions; however, only those compounds passed to the second, separation column, which passes through the cryotrap, will be subjected to GC x GC analysis. The technique and the various modes of operation are described in this paper.  相似文献   

20.
The use of a thin film of monolayer-protected gold nanoparticles (MPNs) as a stationary phase for gas chromatography (GC) is reported. Deposition of a MPN film was obtained in a 2-m, 530-microm-i.d. deactivated silica capillary using gravity to force the solution containing the MPN material through the capillary. By SEM analysis, the average film thickness was determined to be 60.7 nm. The retention behavior for the dodecanethiol MPN column was studied using four compound classes (alkanes, alcohols, aromatics, ketones), and retention orders were objectively compared to a commercially available column (AT-1, 100-nm film thickness). Separation of an eight-component mixture was performed using both isothermal and temperature-programming methods with the dodecanethiol MPN phase and compared to an isothermal separation with the AT-1 phase. The AT-1 phase separation had an efficiency, N, of 6200 (k' = 0.33) while the dodecanethiol MPN phase separation had an efficiency, N, of 5700 (k' = 0.21) for the same analyte, octane. The reduced plate height, h, for octane was found to be less than 1 at the optimum linear flow velocity, indicating the MPN column operated near the optimum possible performance level. Robustness of the MPN phase is also discussed with consistent performance observed over several months. Overall, MPNs appear promising as a stationary-phase material for GC and as an experimental platform to study their thermodynamic and mass-transfer properties.  相似文献   