1.
This paper deals with the analysis of hybrid photovoltaic thermal (PVT) water collectors under constant collection temperature mode unlike constant flow rate mode. The analysis has been carried out in terms of thermal energy, electrical energy and exergy gain for two different configurations namely case A (collector partially covered by PV module) and case B (collector fully covered by PV module). The results are compared with the conventional flat plate collector (FPC). The effect of collector area covered by PV module on the performance of hybrid PVT water collector has been studied. The characteristic equations have also been developed for both the cases.It has been observed that case A is more favorable for thermal energy point of view, while case B is suitable for electricity generation. On the basis of the numerical calculations the annual thermal energy gain is found to be 4167.3 and 1023.7 and annual net electrical energy gain is 320.65 and 1377.63 for cases A and B respectively. The annual overall thermal energy gain is decreased by 9.48% and an annual overall exergy gain is increased by 39.16% from case A to case B.  相似文献   

2.
Photovoltaic-thermal (PV/T) technology refers to the integration of a PV and a conventional solar thermal collector in a single piece of equipment. In this paper we evaluate the performance of partially covered flat plate water collectors connected in series using theoretical modeling. PV is used to run the DC motor, which circulates the water in a forced mode. Analytical expressions for N collectors connected in series are derived by using basic energy balance equations and computer based thermal models. This paper shows the detailed analysis of thermal energy, exergy and electrical energy yield by varying the number of collectors by considering four weather conditions (a, b, c and d type) for five different cities (New Delhi, Bangalore, Mumbai, Srinagar, and Jodhpur) of India. Annual thermal and electrical energy yield is also evaluated for four different series and parallel combination of collectors for comparison purpose considering New Delhi conditions. This paper also gives the total carbon credit earned by the hybrid PV/T water heater investigated as per norms of Kyoto Protocol for New Delhi climatic conditions. Cost analysis has also been carried out.It is observed that the collectors partially covered by PV module combines the production of hot water and electricity generation and it is beneficial for the users whose primary requirement is hot water production and collectors fully covered by PV is beneficial for the users whose primary requirement is electricity generation. We have also found that if this type of system is installed only in 10% of the total residential houses in Delhi then the total carbon credit earned by PV/T water heaters in terms of thermal energy is USD $144.5 millions per annum and in terms of exergy is USD $14.3 millions per annum, respectively.  相似文献   

3.
4.
In this paper, an integrated combined system of a photovoltaic (glass–glass) thermal (PV/T) solar water heater of capacity 200 l has been designed and tested in outdoor condition for composite climate of New Delhi. An analytical expression for characteristic equation for photovoltaic thermal (PV/T) flat plate collector has been derived for different condition as a function of design and climatic parameters. The testing of collector and system were carried out during February–April, 2007. It is observed that the photovoltaic thermal (PV/T) flat plate collector partially covered with PV module gives better thermal and average cell efficiency which is in accordance with the results reported by earlier researchers.  相似文献   

5.
In this paper, an attempt has been made to evaluate and compare the energy matrices of a hybrid photovoltaic thermal (HPVT) water collector under constant collection temperature mode with five different types of PV modules namely c-Si, p-Si, a-Si (thin film), CdTe and CIGS. The analysis is based on overall thermal energy and exergy outputs from HPVT water collector. The temperature dependent electrical efficiency has also been calculated under composite climate of New Delhi, India.It is observed that c-Si PV module is best alternative for production of electrical power. Maximum annual overall thermal energy and exergy is obtained for c-Si PV module. The maximum and minimum EPBT of 1.01 and 0.66 years on energy basis is obtained for c-Si and CIGS respectively, whereas on exergy basis maximum EPBT of 5.72 years is obtained for a-Si and minimum of 3.44 in obtained for CIGS PV module. EPF and LCCE increase with increasing the life time of the system.  相似文献   

6.
In this paper, the optimization of a solar photovoltaic thermal (PV/T) water collector which is based on exergy concept is carried out. Considering energy balance for different components of PV/T collector, we can obtain analytical expressions for thermal parameters (i.e. solar cells temperature, outlet water temperature, useful absorbed heat rate, average water temperature, thermal efficiency, etc.). Thermal analysis of PV/T collector depends on electrical analysis of it; therefore, five-parameter current–voltage (IV) model is used to obtain electrical parameters (i.e. open-circuit voltage, short-circuit current, voltage and current at the point which has maximum electrical power, electrical efficiency, etc.). In order to obtain exergy efficiency of PV/T collector we need exergy analysis as well as energy analysis. Considering exergy balance for different components of PV/T collector, we obtain the expressions which show the exergy of the different parts of PV/T collector. Some corrections have been done on the above expressions in order to obtain a modified equation for the exergy efficiency of PV/T water collector. A computer simulation program has been developed in order to obtain the amount of thermal and electrical parameters. The simulation results are in good agreement with the experimental data of previous literature. Genetic algorithm (GA) has been used to optimize the exergy efficiency of PV/T water collector. Optimum inlet water velocity and pipe diameter are 0.09 m s−1, 4.8 mm, respectively. Maximum exergy efficiency is 11.36%. Finally, some parametric studies have been done in order to find the effect of climatic parameters on exergy efficiency.  相似文献   

7.
文章设计了新型非晶硅太阳能PV/T空气集热器,该空气集热器能够解决传统太阳能PV/T热水器在高温波动情况下,晶硅电池热应力大的问题,同时避免了冬季管道发生霜冻的现象。文章通过实验对比,分析了非晶硅太阳能PV/T空气集热器、单独非晶硅光伏电池和传统太阳能空气集热器的能量效率和[火用]效率的差异。分析结果表明:非晶硅太阳能PV/T空气集热器的平均热效率为45.70%,比传统太阳能空气集热器的平均热效率降低了约25.88%;当空气质量流量增大至0.048 kg/s时,非晶硅太阳能PV/T空气集热器中的非晶硅光伏电池的平均电效率高于单独非晶硅光伏电池,它们的平均电效率分别为4.70%,4.54%;非晶硅太阳能PV/T空气集热器的总[火用]效率高于传统太阳能空气集热器的热[火用]效率和单独非晶硅光伏电池的电[火用]效率,非晶硅太阳能PV/T空气集热器总[火用]效率最大值为7.14%。文章的分析结果为非晶硅太阳能PV/T空气集热器的推广提供了参考。  相似文献   

8.
In this paper, an attempt has been made to evaluate the overall performance of hybrid PV/thermal (PV/T) air collector. The different configurations of hybrid air collectors which are considered as unglazed and glazed PV/T air heaters, with and without tedlar. Analytical expressions for the temperatures of solar cells, back surface of the module, outlet air and the rate of extraction of useful thermal energy from hybrid PV/T air collectors have been derived. Further an analytical expression similar to Hottel–Whiller–Bliss (HWB) equation for flat plate collector has also been derived in terms of design and climatic parameters. Numerical computations have been carried out for composite climate of New Delhi and the results for different configurations have been compared. The thermal model for unglazed PV/T air heating system has also been validated experimentally for summer climatic conditions. It is observed that glazed hybrid PV/T without tedlar gives the best performance.  相似文献   

9.
Electrical and thermal energy have wide applications for the future of mankind. A solar photovoltaic thermal system is a hybrid system, which can produce both thermal and electrical energy. Chennai has an appropriate climate and is highly suitable for using photovoltaic thermal hybrid systems. This article presents the mathematical analyses of the thermal, electrical, and exergetic performance of a photovoltaic thermal system augmented by a flat plate collector for a typical domestic application. The system is found to have 11% average electrical efficiency, 15% overall exergy efficiency, and 56% overall energy efficiency.  相似文献   

10.
The photovoltaic thermal collector can provide thermal and heat power at the same time.In this paper, a photovoltaic/thermal sheet and tube collector has been numerically investigated. The paper focuses on the development of a hybrid solar collector PV/T. This model will be applied to optimize the operation of the PVT collector in the semi-arid climate. A mathematical model has been developed to determine the dynamic behavior of the collector, based on the energy balance of six main components namely a transparent cover, a PV module, a plate absorber, a tube, water in the tube and insulation. It has been validated by comparing the obtained simulation results with experimental results available in literature, where good agreement has been noted. Using our developed model, the heat and electrical power of sheet and tube collector has been analyzed for four typical days of year with the meteorological parameters of Monastir, Tunisia. Furthermore, the effect of solar radiation, the inlet water temperature, the number of glazing covers and the conductive heat transfer coefficient between plate absorber and PV module have been involved to identify their influence on the thermal and electrical efficiencies. The monthly thermal and electrical energies is also evaluated.  相似文献   

11.
提出一种真空玻璃盖板平板式PV/T集热器,建立了真空玻璃和单层玻璃盖板PV/T集热器的传热模型,并分别搭建了两种PV/T热水系统的实验平台进行模型的实验验证。预测结果与实验测量结果的均方根偏差(RMSD)在0.71% ~ 11.17%之间。利用数学模型模拟了真空玻璃与单层玻璃盖板PV/T集热器在合肥冬季的热、电性能,并比较了两者性能的差异。模拟结果表明真空玻璃盖板PV/T集热器的顶部热损失平均为22 W,而单层玻璃盖板PV/T集热器热损失平均为107 W。使用真空玻璃盖板能显著减少PV/T集热器的顶部热损失。真空玻璃盖板PV/T集热器相对单层玻璃盖板PV/T集热器的全天热效率提高了5.68%,二者分别为41.76%和36.08%,全天电效率分别为11.76%和12.79%,相差1.03%。  相似文献   

12.
《Energy Conversion and Management》2005,46(18-19):3034-3046
The advantages of photovoltaic/thermal (PV/T) collectors and low solar concentration technologies are combined into a photovoltaic/thermal system to increase the solar energy conversion efficiency. This paper presents a prototype 11X concentration rate and two axis tracking system. The main novelty is the coupling of a linear Fresnel concentrator with a channel photovoltaic/thermal collector. An analytical model to simulate the thermal behaviour of the prototype is proposed and validated. Measured thermal performance of the solar system gives values above 60%. Theoretical analysis confirms that thermal conduction between the PV cells and the absorber plate is a critical parameter.  相似文献   

13.
In this paper, an exergetic optimization has been developed to determine the optimal performance and design parameters of a solar photovoltaic thermal (PV/T) air collector. A detailed energy and exergy analysis has been carried out to calculate the thermal and electrical parameters, exergy components, and exergy efficiency of a typical PV/T air collector. The thermal and electrical parameters of a PV/T air collector include solar cell temperature, back surface temperature, outlet air temperature, open‐circuit voltage, short‐circuit current, maximum power point voltage, maximum power point current, etc. An improved electrical model has been used to estimate the electrical parameters of a PV/T air collector. Furthermore, a new equation for the exergy efficiency of a PV/T air collector has been derived in terms of design and climatic parameters. A computer simulation program has been also developed to calculate the thermal and electrical parameters of a PV/T air collector. The results of numerical simulation are in good agreement with the experimental measurements noted in the previous literature. Moreover, the simulation results obtained in this paper are more precise than the one given by the previous literature, and the new exergy efficiency obtained in this paper is in good agreement with the one given by the previous literature. Finally, exergetic optimization has been carried out under given climatic, operating, and design parameters. The optimized values of inlet air velocity, duct length, and the maximum exergy efficiency have been found. Parametric studies have been also carried out. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

14.
In the present work a comparative study for thermal and electrical performance of different hybrid photovoltaic/thermal collectors designs for Iraq climate conditions have been carried out. Four different types of air based hybrid PV/T collectors have been manufactured and tested. Three collectors consist of four main parts namely, channel duct, glass cover, axial fan to circulate air and two PV panels in parallel connection. The measured parameters are, the temperature of the upper and the lower surfaces of the PV panels, air temperature along the collector, air flow rate, pressure drop, power produced by solar cell, and climate conditions such as wind speed, solar radiation and ambient temperature. The thermal and hydraulic performances of PV/T collector model IV have been analyzed theoretically based on energy balance. A Matlab computer program has been developed to solve the proposed mathematical model.The obtained results show that the combined efficiency of collector model III (double duct, single pass) is higher than that of model II (single duct double pass) and model IV (single duct single pass). Model IV has the better electrical efficiency. The pressure drop of model III is lower than that of models II and IV. The root mean square of percentage deviations for PV outlet temperature, and thermal efficiency of model IV are found to be 3.22%, and 18.04% respectively. The calculated linear coefficients of correlation (r) are 0.977, 0.965 respectively.  相似文献   

15.
Photovoltaic-thermal collectors (or PV-T collector) are hybrid collectors where PV modules are integrated as an absorber of a thermal collector in order to convert solar energy into electricity and usable heat at the same time. In most of the cases, the hybrid collectors are made by the superposition of a PV module on the thermal absorber of a solar collector. In this paper, the approach is different and is to analyze thermal and optical properties related to both PV and solar thermal functions in order to identify an optimum combination leading to a maximum overall efficiency. Indeed, although these two functions do not exploit the same range of radiation wavelengths, thermal and PV functions are not so complementary due to photo-conversion thermal dependency. In this context, an alternative PV cell lamination has been developed with increased optical and thermal performance. The improvements were evaluated around 2 mA/cm2 in terms of current density in comparison to a standard module encapsulation. Based on this technique, a real size PV-T module has been built and tested at Fraunhofer solar test facilities. The results show a global efficiency of the PV-T collector above 87% (79% thermal efficiency plus 8.7% electrical efficiency, based on the absorber area).  相似文献   

16.
G. Fraisse  C. Mnzo  K. Johannes 《Solar Energy》2007,81(11):1426-1438
The integration of photovoltaic (PV) modules in buildings allows one to consider a multifunctional frame and then to reduce the cost by substitution of components. In order to limit the rise of the cell operating temperature, a photovoltaics/thermal (PV/T) collector combines a solar water heating collector and PV cells. The recovered heat energy can be used for heating systems and domestic hot water. A combination with a Direct Solar Floor is studied. Its low operating temperature level is appropriate for the operating conditions of the mono- or poly-crystalline photovoltaic modules which are selected in that study. However, for a system including a glass covered collector and localised in Mâcon area in France, we show that the annual photovoltaic cell efficiency is 6.8% which represents a decrease of 28% in comparison with a conventional non-integrated PV module of 9.4% annual efficiency. This is obviously due to a temperature increase related to the cover. On the other hand, we show that without a glass cover, the efficiency is 10% which is 6% better than a standard module due to the cooling effect.Moreover, in the case of a glazed PV/T collector with a conventional control system for Direct Solar Floor, the maximum temperature reached at the level of the PV modules is higher than 100 °C. This is due to the oversize of the collectors during the summer when the heating needs are null, i.e. without a heated swimming pool for example. This temperature level does not allow the use of EVA resin (ethylene vinyl acetate) in PV modules due to strong risks of degradation. The current solution consists of using amorphous cells or, if we do not enhance the thermal production, uncovered PV/T collector. Further research led to water hybrid PV/T solar collectors as a one-piece component, both reliable and efficient, and including the thermal absorber, the heat exchanger and the photovoltaic functions.  相似文献   

17.
In this paper, an exergetic optimization of flat plate solar collectors is developed to determine the optimal performance and design parameters of these solar to thermal energy conversion systems. A detailed energy and exergy analysis is carried out for evaluating the thermal and optical performance, exergy flows and losses as well as exergetic efficiency for a typical flat plate solar collector under given operating conditions. In this analysis, the following geometric and operating parameters are considered as variables: the absorber plate area, dimensions of solar collector, pipes' diameter, mass flow rate, fluid inlet, outlet temperature, the overall loss coefficient, etc. A simulation program is developed for the thermal and exergetic calculations. The results of this computational program are in good agreement with the experimental measurements noted in the previous literature. Finally, the exergetic optimization has been carried out under given design and operating conditions and the optimum values of the mass flow rate, the absorber plate area and the maximum exergy efficiency have been found. Thus, more accurate results and beneficial applications of the exergy method in the design of solar collectors have been obtained.  相似文献   

18.
The objective of present study is to evaluate the performance of the photovoltaic (PV) module integrated with air duct for composite climate of India. In this case, thermal energy is produced along with electrical energy generated by a PV module with higher efficiency. An analytical expression for an overall efficiency (electrical and thermal) has been derived by using energy balance equation for each component. Experimental validation of thermal model of hybrid photovoltaic/thermal (PV/T) system has also been carried out. It has been observed that there is a fair agreement between theoretical and experimental observations. Further it is concluded that an overall thermal efficiency of PV/T system is significantly increased due to utilization of thermal energy in PV module.  相似文献   

19.
In a photovoltaic/thermal (PV/T) collector, a portion of absorbed solar energy is transformed into electrical energy, and the remaining part is transformed into thermal energy. Increasing waste heat collection and energy conversion rates are important to improve the performance of the PV/T collector. The utilization of microencapsulated phase change slurry (MPCS) in a PV/T collector to cool photovoltaic modules is an effective way, and electrical and thermal performances of the collector are improved. To investigate influences of operating parameters on performances of PV/T collector, numerical simulation is put into effect to analyze influences of the mass fraction of MPCS on the collector performance. The influences of MPCS mass flow rate and collector channel height on collector performances are also studied. When the flow rate is 0.005 kg/s and the channel height is 0.010 m, the PV/T collector obtains the best net efficiency with a MPCS mass concentration of 20 wt%. But electrical efficiency difference between 15 and 20 wt% is not obvious. With the growth in mass fraction, PV temperature drops more and more slowly because outlet fluid has not fully melt. Take PV/T collector performances into consideration, 15 wt% MPCS is a better choice to cool photovoltaic modules.  相似文献   

20.
This paper reviews the recent hybrid photovoltaic thermal (PV/T) structural/geometrical topologies to highlight the state of the art on this form of collector approaches and designs for both liquid and air‐based systems. The review focuses on the development of the typical flat‐plate collector – as an essential part in the PV/T system – in terms of new concept and novel configurations and specifically on the design of these collectors that use air or liquid as a heat transfer medium and their ability to extract useful heat from the back surface of the PV panel. Different mechanisms of fluid flow either natural or forced are considered. Many different design configurations for hybrid PV/T collectors have been cataloged and evaluated. It is shown that at least 30 distinct configurations have been introduced in the literature in the last 5 years. The paper concludes with identifying the major factors that affect the performance of typical PV/T systems and lead to effective enhancement of the heat removal mechanisms thus improving the electrical and thermal solar conversion efficiencies. This paper should serve as a significant form of reference for any future development in the design of the PV/T concept. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   