首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this work, an electrochemical sensor based on ordered mesoporous carbon (OMC) for the amperometric detection of isoniazid was developed. OMC was dispersed in a solution of Nafion, and the suspension was modified onto the surface of glassy carbon (GC) electrode. Cyclic voltammetry and amperometry were used to investigate the electrochemical behaviors of isoniazid on Nafion-OMC modified electrode (Nafion-OMC/GC). The results indicate that OMC can facilitate the electrochemical oxidation of isoniazid with a great decrease of overpotential in pH 7.0 phosphate buffer solution. The proposed biosensor provides excellent performance towards the determination of isoniazid with a high sensitivity of 0.031 μA/μM, a low detection limit of 8.4 × 10−8 M and wide linear range from 1.0 × 10−7 M to 3.7 × 10−4 M at +0.20 V vs. Ag/AgCl. The method was successfully applied to the determination of isoniazid tablets with satisfying results. All the results suggest that Nafion-OMC/GC electrode is a potential candidate for a stable and efficient electrochemical sensor to detect isoniazid.  相似文献   

2.
A novel nanocomposite, comprising of graphene sheet (GS) and ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate (BMIMPF6), was developed on the glassy carbon electrode (GCE) for the simultaneous determination of hydroquinone and catechol in 0.10 M acetate buffer solution (pH 5.0). At the GS/BMIMPF6/GCE, both hydroquinone and catechol can cause a pair of quasi-reversible and well-defined redox peaks. In comparison with bare GCE and GS modified electrode, GS/BMIMPF6/GCE showed larger peak currents, which was related to the higher specific surface area of graphene and high ionic conductivity of BMIMPF6. Under the optimized condition, the cathodic peak current were linear over ranges from 5.0 × 10−7 M to 5.0 × 10−5 M for hydroquinone and from 5.0 × 10−7 M to 5.0 × 10−5 M for catechol, with the detection limits of 1.0 × 10−8 M and 2.0 × 10−8 M, respectively. The proposed method was successfully applied to the simultaneous determination of hydroquinone and catechol in artificial sample, and the results are satisfactory.  相似文献   

3.
A label-free DNA biosensor for hybridization detection of short DNA species related to the transgenic plants gene fragment of cauliflower mosaic virus (CaMV) 35S promoter was developed in this paper. The nanocomposite containing chitosan (CS) and mutiwalled carbon nanotubes (MWNTs) was first coated on a glassy carbon electrode. Then a highly reactive dialdehyde reagent of glutaraldehyde (GTD) was applied as an arm linker to covalently graft the 5′-amino modified probe DNA to the CS-MWNTs surface via the facile aldehyde-ammonia condensation reaction. The hybridization capacity of the developed biosensor was monitored with electrochemical impedance spectroscopy (EIS) using [Fe(CN)6]3−/4− as an indicating probe, and the experimental results showed that the biosensor had fast hybridization rate and low background interference. A wide dynamic detection range (1.0 × 10−13-5 × 10−10 M) and a low detection limit (8.5 × 10−14 M) were achieved for the complementary sequence. In addition, the hybridization specificity experiments showed that the sensing system can accurately discriminate complementary sequence from mismatch and noncomplementary sequences.  相似文献   

4.
A highly sensitive hydrazine sensor was developed based on the electrodeposition of gold nanoparticles onto the choline film modified glassy carbon electrode (GNPs/Ch/GCE). The electrochemical experiments showed that the GNPs/Ch film exhibited a distinctly higher activity for the electro-oxidation of hydrazine than GNPs with 3.4-fold enhancement of peak current. The kinetic parameters such as the electron transfer coefficient (α) and the rate of electron exchange (k) for the oxidation of hydrazine were determined. The diffusion coefficient (D) of hydrazine in solution was also calculated by chronoamperometry. The sensor exhibited two wide linear ranges of 5.0 × 10−7-5.0 × 10−4 and 5.0 × 10−4-9.3 × 10−3 M with the detection limit of 1.0 × 10−7 M (s/n = 3). The proposed electrode presented excellent operational and storage stability for the determination of hydrazine. Moreover, the sensor showed outstanding sensitivity, selectivity and reproducibility properties. All the results indicated a good potential application of this sensor in the detection of hydrazine.  相似文献   

5.
The electrocatalysis of hydrazine oxidation by poly-ethylenedioxy pyrrole (PEDOP)-coated MWCNTs-palladium nanoparticles [PEDOP/MWCNTs-Pd] was investigated as an electrochemical sensor on the surface of glassy carbon electrode (GCE) in aqueous medium. Electrochemical oxidation of hydrazine in phosphate buffer (pH 7.4) was performed using cyclic voltammetry (CV) and chronoamperometry (CA) methods. Using the proposed electrode, the catalytic oxidation peak current of hydrazine was high and the overpotential of its oxidation decreased. Based on the obtained results, a mechanism for electrooxidation of hydrazine at [PEDOP/MWCNTs-Pd/GCE] demonstrated an irreversible diffusion-controlled electrode process and a four-electron transfer involved in the overall reaction. The experimental results showed that the mediated oxidation peak currents of the hydrazine were linearly dependent on the concentration of hydrazine in the range of 1.0 × 10−7 to 5.0 × 10−3 M. The detection limit (S/N = 3) was found to be 4 × 10−8 M with a fast response time of 10 s.  相似文献   

6.
This paper presents the amperometric biosensor that determines choline and cholinesterase activity using a screen printed graphite electrode. In order to detect H2O2 we have blanket modified the electrode material with manganese dioxide nanoparticles layer. Using layer-by-layer technique on the developed hydrogen peroxide sensitive electrode surface choline oxidase was incorporated into the interpolyelectrolyte nanofilm. Its ability to serve as a detector of choline in bulk analysis and cholinesterase assay was investigated. We examined the interferences from red-ox species and heavy metals in the blood and in the environmental sample matrixes. The sensor exhibited a linear increase of the amperometric signal at the concentration of choline ranging from 1.3 × 10−7 to 1.0 × 10−4 M, with a detection limit (evaluated as 3σ) of 130 nM and a sensitivity of 103 mA M−1 cm−2 under optimized potential applied (480 mV vs. Ag/AgCl). The biosensor retained its activity for more than 10 consecutive measurements and kept 75% of initial activity for three weeks of storage at 4 °C. The R.S.D. was determined as 1.9% for a choline concentration of 10−4 M (n = 10) with a typical response time of about 10 s. The developed choline biosensor was applied for butyrylcholinesterase assay showing a detection limit of 5 pM (3σ). We used the biosensor to develop the cholinesterase inhibitor assay. Detection limit for chlorpyrifos was estimated as 50 pM.  相似文献   

7.
In present paper, the graphene doped carbon paste electrode (CPE) was firstly prepared with the addition of graphene into the carbon paste mixture. Compared with conventional CPE, an improved electrochemical response of graphene doped CPE toward the redox couple of Fe(CN)63−/4− was demonstrated owing to the excellent electrical conductivity of graphene. The graphene doped CPE was further used for the successful determination of ascorbic acid (AA), and it showed an excellent electrocatalytic oxidation activity toward AA with a lower overvoltage, pronounced current response, and good sensitivity. Under the optimized experimental conditions, the proposed electrochemical AA sensor exhibited a rapid response to AA within 5 s and a linear calibration plot ranged from 1.0 × 10−7 to 1.06 × 10−4 M was obtained with a detection limit of 7.0 × 10−8 M.  相似文献   

8.
A highly sensitive electrochemical sensor for the determination of acetaminophen at the multiwalled carbon nanotube-alumina-coated silica (MWCNT-ACS) nanocomposite modified glassy carbon electrode is reported. The morphology of the MWCNT-ACS nanocomposite was characterized by field emission scanning electron microscopy. The electrocatalytic properties of the MWCNT-ACS nanocomposite modified glassy carbon electrode were characterized by cyclic voltammetry and square-wave voltammetry in the presence of acetaminophen. The MWCNT-ACS nanocomposite modified glassy carbon electrode exhibited the abilities to raise the current response and to decrease the electrooxidation potential. In cyclic voltammetric responses, the oxidation peak current of acetaminophen obtained at the MWCNT-ACS modified glassy carbon electrode was 100 times greater than that of bare glassy carbon electrode. The MWCNT-ACS nanocomposite modified glassy carbon electrode for the determination of acetaminophen displayed a sensitivity of 376.5 A M−1 cm−2 and a detection limit of 0.05 μM using square-wave voltammetry. The analytical applicability of the developed method was achieved by analyzing the content of acetaminophen in five commercial drugs without pretreatment.  相似文献   

9.
In this work, we demonstrated a sensitive and selective electrochemical sensing protocol for the detection of TNT prepared from alkanethiols self-assembled on AuNPs modified glassy carbon (GC) electrode with preadsorbed templates of TNT. It demonstrated that the 2D molecular imprinting monolayers (MIMs) can provide a better site accessibility and lower mass-transfer resistance, while the AuNPs can enhance electrode conductivity, facilitate the electron transfer and increase the amount of TNT-imprinted sites. The prepared sensor showed not only high selectivity toward TNT in comparison to other similar nitroaromatic compounds (NACs), but also a wide linear range over TNT concentration from 4.0 × 10−8 to 3.2 × 10−6 M with a detection limit of 1.3 × 10−8 M (S/N = 3). Moreover, the imprinted sensor has been applied to the determination of TNT in spiked environmental water samples and shows promise for fast and sensitive measurement of trace levels of TNT in real samples.  相似文献   

10.
For the first time a novel derivatized multi-walled carbon nanotubes-based Pb2+ carbon paste electrode is reported. The electrode with optimum composition, exhibits an excellent Nernstian response to Pb2+ ion ranging from 5.9 × 10−10 to 1.0 × 10−2 M with a detection limit of 3.2 × 10−10 M and a slope of 29.5 ± 0.3 mV dec−1 over a wide pH range (2.5-6.5) with a fast response time (25 s) at 25 °C. Moreover, it also shows a high selectivity and a long life time (more than 3 months). Importantly, the response mechanism of the proposed electrode was investigated using AC impedance technique. Finally, the electrode was successfully applied for the determination of Pb2+ ion concentration in environmental samples, e.g. soils, waste waters, lead accumulator waste and black tea, and for potentiometric titration of sulfate anion.  相似文献   

11.
Barium titanate (BaTiO3) nanofibers were synthesized by electrospinning and calcination techniques. Two direct current (DC) humidity sensors with different electrodes (Al and Ag) were fabricated by loading BaTiO3 nanofibers as the sensing material. Compared with the Al electrode sensor, the Ag electrode sensor exhibits larger sensitivity and quicker response/recovery. The current of Al electrode sensor increases from 4.08 × 10−9 to 1.68 × 10−7 A when the sensor is switched from 11% to 95% relative humidity (RH), while the values are 2.19 × 10−9 and 3.29 × 10−7 A for the Ag electrode sensor, respectively. The corresponding response and recovery times are 30 and 9 s for Al electrode sensor, and 20 and 3 s for Ag electrode sensor, respectively. These results make BaTiO3 nanofiber-based DC humidity sensors good candidates for practical application. Simultaneously, the comparison of sensors with different electrode materials may offer an effective route for designing and optimizing humidity sensors.  相似文献   

12.
A simple strategy has been used to covalently modify the glassy carbon spheres with anthraquinone moieties through the diazonium salt reduction. The derivatized glassy carbon spheres were used to modify the basal plane pyrolytic graphite electrode by immobilizing them on its surface and examining its electrochemical behaviour. The composite electrode has been used to detect trace level ammonia in the concentration range 5 × 10−8 to 3 × 10−5 M and it was successfully applied to detect low levels of ammonia present in natural samples like urine and soil.  相似文献   

13.
A biosensor based on bovine serum albumin (BSA) and poly-o-phenylenediamine (PoPD)/carbon-coated nickel (C-Ni) nanobiocomposite film modified electrode has been developed to study the interaction of BSA with papaverine (PAP). The well-dispersed C-Ni nanoparticles were dripped onto the glassy carbon electrode (GCE) surface firstly, and PoPD films were subsequently electropolymerized by cyclic voltammetry (CV) to prepare PoPD/C-Ni/GCE. Finally, the BSA was easily immobilized on the PoPD films via electrostatic adsorption. The morphology and the electrochemical properties of the fabricated composite electrodes were examined by scanning electron microscope (SEM) and electrochemical impedance spectroscopy (EIS), respectively. The interaction of PAP with BSA was monitored by differential pulse voltammetry (DPV), using PoPD as the electrochemical indicator. The binding constant (K), obtained by DPV, was 1.7 × 104 L/mol, which was consistent with the fluorescence analysis. This constructed biosensor also exhibited a fine linear correlation with PAP concentration range of 2.5 × 10−9-4.5 × 10−5 mol/L and a detection limit of 8.3 × 10−10 mol/L was achieved by DPV.  相似文献   

14.
An electrochemical sensor based on graphene-polyaniline (GR-PANI) nanocomposite for voltammetric determination of 4-aminophenol (4-AP) is presented. The electrochemical behavior of 4-AP at the GR-PANI composite film modified glassy carbon electrode (GCE) was investigated by cyclic voltammetry. 4-AP exhibits enhanced voltammetric response at GR-PANI modified GCE. This electrochemical sensor shows a favorable analytical performance for 4-AP detection with a detection limit of 6.5 × 10−8 M and high sensitivity of 604.2 μA mM−1. Moreover, 4-AP and paracetamol can be detected simultaneously without interference of each other in a large dynamic range.  相似文献   

15.
A new all-solid-state Cd2+-selective electrode with a low detection limit was prepared by using conjugated thiophene oligomer α-sexithiophene (α-6T) as solid contact deposited between an ionophore-doped poly(vinyl chloride) membrane and a gold disc substrate. The electrode exhibited a Nernstian response for Cd2+ ions over a wide concentration range of 10−3-10−7 M with a detection limit as low as 1.3 × 10−8 M. Results showed that the fabricated potentiometric sensor was suitable for use within the pH range of 2.0-9.0 and exhibited good reproducibility for long-term measurements.  相似文献   

16.
Iron(II) phthalocyanine (FePc) modified multi-wall carbon nanotubes paste electrodes (MWCNTPEs) were used as voltammetric sensors to selectively detect dopamine (DA) in the presence of serotonin (5-HT). The electrochemical behavior of DA at the new modified electrode was investigated using CV. The enhanced current response of DA indicates that FePc modification of the MWCNTPE surface results in a high catalytic activity for the redox reaction of DA. Differential pulse voltammetry was applied in detection of DA and 5-HT at FePc-MWCNTPE. The method parameters were optimized. Detection limit of 2.05 × 10−7 M was obtained for DA by using the electrocatalytic oxidation signal corresponding to the FeII/FeIII redox process. The separation between the peak potentials of DA and 5-HT is 170 mV which is large enough for the simultaneously, selective determination of the two chemical species in their mixtures. There was no electrochemical response for ascorbic acid (AA) added in the sample. The monoamine neurotransmitter measuring method has been tested in analyzing deproteinized serum samples.  相似文献   

17.
A new dopamine-derivative, i.e. N-(3,4-dihydroxyphenethyl)-3,5-dinitrobenzamide (N-DHPB), was synthesized and its application was investigated for the simultaneous determination of N-acetylcysteine (NAC) and acetaminophen (AC) using modified multiwall carbon nanotubes paste electrode. This modified electrode exhibited a potent and persistent electron mediating behavior followed by well separated oxidation peaks of NAC and AC. The peaks current of differential pulse voltammograms of NAC and AC increased linearly with their concentration in the ranges of 0.5-200 μmol L−1 NAC and 15.0-270 μmol L−1 AC. The detection limits for NAC and AC were 0.2 μmol L−1 and 10.0 μmol L−1, respectively. The relative standard deviation for seven successive assays of 1.0 and 30.0 μmol L−1 NAC and AC were 1.7% and 2.2%, respectively. The proposed sensor was successfully applied for the determination of NAC in human urine, tablet, and serum samples.  相似文献   

18.
The present work describes the electrocatalytic behavior of phosphotungstate-doped glutaraldehyde-cross-linked poly-l-lysine (PLL-GA-PW) film electrode towards reduction of hydrogen peroxide (H2O2) in acidic medium. The modified electrode was prepared by means of electrostatically trapping the phosphotungstate anion into the cationic PLL-GA coating on glassy carbon electrode. The PLL-GA-PW film electrode showed excellent electrocatalytic activity towards H2O2 reduction in 0.1 M H2SO4. Under the optimized conditions, the electrochemical sensor exhibited a linear response for H2O2 concentration over the range 2.5 × 10−6 to 6.85 × 10−3 M with a sensitivity of 1.69 μA mM−1. The curvature in the calibration curve at high concentration is explained in terms of Michaelis-Menten (MM) saturation kinetics, and the kinetics parameters calculated by three different methods were compared. The PLL-GA-PW film electrode did not respond to potential interferents such as dopamine, ascorbic acid and uric acid. This unique feature of PLL-GA-PW film electrode allowed selective determination of H2O2. Finally, the proposed electrochemical sensor was successfully applied to determine H2O2 in commercially available antiseptic solution and soft-contact lenses cleaning solution and the method has been validated using independent estimation by classical potassium permanganate titration method. Major advantages of the method are simple electrode fabrication, stability and high selectivity towards hydrogen peroxide.  相似文献   

19.
An electrochemical biosensor for determination of hydrogen peroxide (H2O2) has been developed by the hybrid film of poly(methylene blue) and FAD (PMB/FAD). The PMB/FAD hybrid film was performed in PBS (pH 7) containing methylene blue and FAD by cyclic voltammetry. Repeatedly scanning potential range of −0.6-1.1 V, FAD was immobilized on the electrode surface by electrostatic interaction while methylene blue was electropolymerized on electrode surface. This modified electrode was found surface confined and pH dependence. It showed good electrocatalytic reduction for H2O2, KBrO3, KIO3, and NaClO as well as electrocatalytic oxidation for NADH. At an applied potential of −0.45 V vs. Ag/AgCl, the sensor showed a rapid and linear response to H2O2 over the range from 0.1 μM to 960 μM, with a detection limit of 0.1 μM and a significant sensitivity of 1109 μA mM−1 cm−2 (S/N = 3). It presented excellent stability at room temperature, with a variation of response current less than 5% over 30 days.  相似文献   

20.
4-Nonylphenol (4-NP) was reported to affect the health of wildlife and humans through altering endocrine function. A novel electrochemical sensor for sensitive and fast determination of 4-NP was developed. Titanium oxide (TiO2) nanoparticles and gold nanoparticles (AuNPs) were introduced for the enhancement of electron conduction and sensitivity. 4-NP-imprinted functionalized AuNPs composites with specific binding sites for 4-NP was modified on electrode. The resulting electrodes were characterized by cyclic voltammetry (CV). Rebinding experiments were carried out to determine the specific binding capacity and selective recognition. The linear range was over the range from 4.80 × 10−4 to 9.50 × 10−7 mol L−1, with the detection limit of 3.20 × 10−7 mol L−1 (S/N = 3). The sensor was successfully employed to detect 4-NP in real samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号