首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVE: Stentless biologic aortic valves are less obstructive than stented biologic or mechanical valves. Their superior hemodynamic performances are expected to reflect in better regression of left ventricular hypertrophy. We compared the regression of left ventricular hypertrophy in 3 groups of patients undergoing aortic valve replacement for severe aortic stenosis. Group I (10 patients) received stentless biologic aortic valves, group II (10 patients) received stented biologic aortic valves, and group III (10 patients) received bileaflet mechanical aortic valves. METHODS: Echocardiographic evaluations were performed before the operation and after 1 year, and the results were compared with those of a control group. Left ventricular diameters and function, left ventricular wall thickness, and left ventricular mass were assessed by echocardiography. RESULTS: Group I patients had a significantly lower maximum and mean transprosthetic gradient than the other valve groups (P = .001). One year after operation there was a significant reduction in left ventricular mass for all patient groups (P < .01), but mass did not reach normal values (P = .05). Although the rate of regression in the interventricular septum and posterior wall thickness differed slightly among groups, their values at follow-up were comparable and still higher than control values (P = .002). The ratio between interventricular septum and posterior wall and the ratio between wall thickness and chamber radius did not change significantly at follow-up. CONCLUSIONS: Because the number of patients was relatively small, we could not use left ventricular mass regression after I year to distinguish among patients undergoing aortic valve replacement for aortic stenosis by means of valve prostheses with different hemodynamic performances.  相似文献   

2.
BACKGROUND: The role of aortic valve replacement for aortic stenosis has not been fully defined in terms of the postoperative reversibility of cardiac dysfunction and pulmonary hypertension in elderly patients. METHODS: Cardiac function, assessed by radioisotope ventriculography and catheterization data, was evaluated before and after operation, and their results were compared between preoperative and postoperative data in each group of younger patients (<69 years, group I, n = 29) and elderly patients (> or =70 years, group II, n = 21). RESULTS: One month postoperatively the peak ejection rate determined by radioisotope ventriculography improved significantly in comparison with the preoperative value in elderly patients (preoperatively, 228 +/- 38 versus postoperatively, 319 +/- 116% end-diastolic volume per second, p < 0.05), although their preoperative peak ejection rate was severely depressed. The postoperative peak filling rate of the elderly group was not completely reversible to almost normal value, whereas that of the younger group was completely reversible. Early diastolic peak filling rate (one-third peak filling rate) was not reversible in both two groups. Pulmonary hypertension in the elderly patients was reversible to postoperative almost normal pulmonary artery pressure despite the severity of aortic stenosis (systolic pulmonary artery pressure preoperatively, 37 +/- 16 mm Hg versus postoperatively, 25 +/- 5 mm Hg, p < 0.02; diastolic pulmonary artery pressure preoperatively, 15 +/- 6 mm Hg versus postoperatively, 10 +/- 4 mm Hg, p < 0.05). CONCLUSIONS: Both cardiac dysfunction, reflected by reduction of peak ejection rate, and pulmonary hypertension in elderly patients with severe aortic stenosis were reversed, reaching almost normal values 1 month after operation.  相似文献   

3.
Isradipine (lomir) is a new highly selective arteriolar vasodilator of the dihydropyridine group, characterized by a slight cardiodepressive effect. The drug effect on the central hemodynamics and oxygen transport was studied after cardiovascular surgery. Arterial pressure and total peripheral vascular resistance were reliably reduced at the peak of the drug action, as was the left-ventricular stroke work and oxygen consumption. A tendency to increase of cardiac output and cardiac index was observed. Pulmonary vascular resistance and pressure in the pulmonary artery did not reliably change. The drug increased the intrapulmonary shunt.  相似文献   

4.
OBJECTIVES: This study was conducted to determine the risks and benefits of valve replacement in patients with severe aortic stenosis and a low transvalvular pressure gradient. BACKGROUND: There is uncertainty regarding the appropriate management of adults with severe aortic stenosis and a transvalvular pressure gradient < or = 30 mm Hg. With only six such patients reported, one study suggested that these subjects have a prohibitive operative risk and little symptomatic improvement if they survive surgical treatment, whereas another showed that they can survive an operation and improve symptomatically. METHODS: In an attempt to clarify the risks and benefits of valve replacement in these patients, we reviewed the records of 18 patients (15 men and 3 women, aged 49 to 81 years) with severe aortic stenosis (valve area < or = 0.4 cm2/m2 body surface area), a mean transvalvular pressure gradient < or = 30 mm Hg and limiting symptoms (New York Heart Association functional class III or IV) who underwent valve replacement. RESULTS: Six patients (33%) (95% confidence interval 13% to 59%) died perioperatively, whereas 10 patients (56%) (95% confidence interval 31% to 78%) improved symptomatically to functional class I (n = 8) or II (n = 2) (p = NS in comparison with the 6 who died). No clinical or hemodynamic variable was predictive of survival or improvement in functional class. CONCLUSIONS: Valve replacement in patients with severe aortic stenosis and a transvalvular pressure gradient < or = 30 mm Hg is accompanied by a considerable operative risk. Although there were no significant differences in this small series between the fraction of patients who died and those who exhibited improvement, we still recommend the procedure because many patients survive the operation and most of the survivors show an improved symptomatic status.  相似文献   

5.
BACKGROUND: This study in humans assessed changes in left ventricular function early and late after correction of mitral regurgitation (MR) (n = 9) or aortic stenosis (AS) (n = 10). METHODS: Ventricular function was measured with radionuclide and micromanometer-derived pressure-volume loops during preload manipulation, thermodilution cardiac outputs, and echocardiograms. Late radionuclide and echocardiographic data were acquired at 24 hours and 20 months. RESULTS: Perioperative left ventricular performance (stroke work-end-diastolic volume relationship) did not change for patients with MR or AS. Significant changes in afterload occurred: ejection fraction (MR, 0.49 to 0.37; AS, 0.54 to 0.60; both, p = 0.013), mean left ventricular ejection pressure (MR, 73 to 91 mm Hg; AS, 138 to 93 mm Hg; both, p < 0.01), and end-systolic wall stress (MR, 26 to 42 x 10(3) dynes/cm2; AS, 37 to 22 x 10(3) dynes/cm2; both, p < 0.01). Ejection efficiency improved for MR patients (0.69 +/- 0.26 to 1.0 +/- 0.15; p < 0.05). The 20-month data showed improved New York Heart Association functional class, normal resting ejection fraction, and normal exercise response for both groups. CONCLUSIONS: Early after operation, a significant change in left ventricular load was seen with correction of MR and AS. Data obtained late after operation showed improvement consistent with ventricular remodeling.  相似文献   

6.
The left ventricular myocardium excised from 14 patients who had mitral stenosis and who underwent mitral valve replacement was examined, and myocardial fibrosis was quantitated in relation to cardiac function. Conventional mitral valve replacement was performed with cold potassium-induced cardioplegia associated with systemic hypothermia (28 degrees C rectal temperature) and topical cooling. All 14 patients had perivascular fibrosis; the amounts ranged from 16% to 54% of the whole tissue excised. The mean left ventricular end-diastolic volume index (LVEDVI) determined by M-mode echocardiography increased significantly (p less than 0.001) from 66.9 +/- 4.6 ml/m2 preoperatively to 79.0 +/- 2.9 ml/m2 postoperatively. The difference between preoperative and postoperative LVEDVIs was significantly correlated (p less than 0.01) to the percentage of myocardial fibrosis (r = 0.72), in that the index increased postoperatively when myocardial fibrosis was more than 35% and decreased when fibrosis was less than 35%. After mitral valve replacement, the mean ejection fraction increased when fibrosis was less than 35% of whole tissue (+0.12 +/- 0.04) and decreased when fibrosis was greater than 35% (-0.02 +/- 0.02, p less than 0.01). No measured preoperative hemodynamic parameters were predictive of prognosis. These data suggest that the degree of myocardial fibrosis is related to left ventricular performance after mitral valve replacement.  相似文献   

7.
8.
OBJECTIVE: To evaluate nuclear grading on fine needle cytopunctures of breast carcinoma, which is of special interest when neoadjuvant chemotherapy is planned. STUDY DESIGN: In a prospective study, we compared cytologic grading, based on nuclear parameters (pleomorphism and mitosis), to modified Scarff-Bloom-Richardson histologic grading in 105 primary operable breast carcinomas. The results of these two nuclear grading systems were compared to Feulgen image analysis data from the corresponding cytologic samples. RESULTS: The concordance rate between the two grading systems was 76%. Concordance between cytologic and histologic grading was observed more frequently in purely invasive carcinomas (85%) than in cases combining invasive and in situ components (56%). A highly significant relationship was observed between the two grading systems and indices of proliferative activity (S-phase fraction, proliferation index, 5c exceeding rate and endoreduplication rate), particularly in concordant grading. Furthermore, nuclear area correlated with the results of the two grading systems. CONCLUSION: Cytologic nuclear grading appeared to be a reliable tool for a large proportion of breast tumors. Despite difficulties related to tumor heterogeneity, which could be detected by careful cytologic examination, it is a useful alternative to histologic grading.  相似文献   

9.
The present review has attempted to summarize the classic symptoms and signs of aortic valve stenosis, especially in an adult. It is emphasized that all the classic signs rarely are present and their absence may mislead an unwary clinician. The diagnostic help provided by noninvasive tests, including echocardiography and phonocardiography, has been emphasized. A need for cardiac catheterization and angiography in most patients prior to corrective surgery is stressed. The natural history of the disease without operative intervention is dim and a significant risk of sudden death exists. The current surgical approach with immediate and long-term results is summarized. Finally, attention has been drawn to the special clinical circumstances when the aortic valve stenosis provides a strinkingly different clinical picture. We cannot find a better way to end this review than by quoting a warning note given by Thomas Lewis in 1920: "It is the faint cry of an anguished and fast failing muscle, which, when it comes, all should strain to hear, for it is not long repeated. A few months, a few years at most, and the end comes."  相似文献   

10.
The authors observed two cases of hyperprolinaemia (one of type I and the other of type II) which were asymptomatic. The anomalies described up to the present time in association with hyperprolinaemia are inconstant, nonspecific, and extremely heterogeneous. This suggests that the relationship between hyperprolinaemia and other anomalies is purely coincidental, and that a therapeutic approach by diet is unjustified.  相似文献   

11.
AIMS/BACKGROUND: Compared with nanosecond (ns) pulses of conventional Nd-YAG lasers, picosecond (ps) laser pulses allow intraocular surgery at considerably lower pulse energy. The authors report initial clinical experiences using a Nd:YLF ps laser for the treatment of various indications for photodisruption. METHODS: A Nd:YLF laser system (ISL 2001, wavelength 1053 nm) was used to apply pulse series of 100-400 microJ single pulse energy at a repetition rate of 0.12-1.0 kHz. Computer controlled patterns were used to perform iridectomies (n = 53), capsulotomies (n = 9), synechiolysis (n = 3), and pupilloplasties (n = 2). Other procedures were vitreoretinal strand incision (n = 2) and peripheral retinotomy (n = 1). For comparison, 10 capsulotomies and 20 iridotomies were performed with a Nd:YAG ns laser. The ps laser cut of an anterior capsule was assessed by scanning electron microscopy (SEM). RESULTS: Open, well defined iridectomies (mean total energy 4028 mJ, mean diameter 724 microns), were achieved at first attempt in 92% of the cases. In 64% an iris bleeding and in 21% an IOP increase of > 10 mm Hg occurred. All capsulotomies were performed successfully (mean energy 690 mJ/mm cutting length) but with a high incidence of intraocular lens damage. The attempted vitreoretinal applications remained unsuccessful as a result of optical aberrations of the eye and contact lens. Although ps laser capsulotomies and iridectomies required much higher total energy than ns procedures, the resulting tissue effects of the ps pulses were more clearly defined. SEM examination of a ps incision of the anterior lens capsule demonstrated, nevertheless, that the cut was more irregular than the edge of a continuous curvilinear capsulorhexis. CONCLUSION: Series of ps pulses applied in computer controlled patterns can be used effectively for laser surgery in the anterior segment and are considerably less disruptive than ns pulses. The ps laser is well suited for laser iridectomies while the ns laser is preferable for posterior capsulotomies. As vitreoretinal applications remained unsuccessful, the range of indications for intraocular photodisruption could not be extended by the ps laser.  相似文献   

12.
13.
The mid-term results in a selected group of 9 patients with native aortic valve endocarditis managed by aortic valve replacement (with or without complex annular reconstruction) using a totally biological stentless valve are outlined. At a mean follow-up of 48 months, there are currently 7 survivors (2 late noncardiac deaths) with 100% freedom from reoperation, valve-related complication, and endocarditis.  相似文献   

14.
OBJECTIVE: Cryopreserved aortic allograft can be used for aortic valve replacement in congenital, rheumatic, degenerative, and infected native valve conditions, as well as failed prosthetic valves. This study was conducted to determine the long-term results of aortic valve replacement with cryopreserved aortic allografts. METHODS: Aortic valve replacement with cryopreserved aortic allografts was performed in 117 patients from July 1985 until August 1996. All patients requiring aortic valve replacement regardless of valve disease were considered for allograft replacement; the valve was preferentially used in patients under age 55 years and in the setting of bacterial endocarditis. Four operative techniques involving cryopreserved aortic allografts were used: freehand aortic valve replacement with 120-degree rotation, freehand aortic valve replacement with intact noncoronary sinus, aortic root enlargement with intact noncoronary sinus, and total aortic root replacement. Valve function was assessed by echocardiography during the operation in 78 patients (66%) and after the operation in 77 patients (65%). RESULTS: One-hundred eighteen aortic valve replacements with cryopreserved aortic allografts were performed on 117 patients; mean age was 45.6 years (range 15 to 83 years) and mean follow-up was 4.6 years (range up to 11 years). Intraoperative echocardiography disclosed no significant aortic valve incompetence. There were four operative deaths (3%) and seven late deaths; freedom from valve-related mortality at 10 years was 9:3% +/- 4.55%. New York Heart Association functional status at latest follow-up was normal in 98 (94%) patients. On postoperative echocardiography, 90% had no or trivial aortic valve incompetence. Freedom from thromboembolism at 10 years was 100% and from endocarditis, 98% +/- 2.47%. Seven (6%) patients required valve explantation, four for structural deterioration. At 10 years, freedom from reoperation for allograft-related causes was 92% +/- 3.47%. CONCLUSIONS: Aortic valve replacement with cryopreserved aortic allografts can be performed with low perioperative and long-term mortality. Most patients have excellent functional status, and reoperation for valve-related causes is unusual. Aortic valve replacement with cryopreserved aortic allografts demonstrates excellent freedom from thromboembolism, endocarditis, and progressive valve incompetence.  相似文献   

15.
A 54-year-old male who had received an aortic valve replacement with SJM 23 about 3 years before suffered from an acute cardiac failure because of the valve detachment. From his clinical course, it was diagnosed that the aortic valve insufficiency was complicated by an aortitis. We operated on him by an aortic root replacement using a cryopreserved allograft which we prepared. A donor of the allograft was 35-year-old male, died of a subarachnoidal hemorrhage. We harvested his aortic root at an autopsy and dipped it into a nutrition medium with 10% dimethylsulfoxide. Within 10 hours from his death, we froze the tissue using a program freezer and stored it in a liquid nitrogen for 7 months. After thawing it in 37 degrees C water quickly, we rinsed the graft and used for the operation. The cell viability of the graft was confirmed by a tissue culture. Indication of the allograft valve to an aortitis case is still controversial. We think the allograft is recommendable to valve detachment case due to aortitis, because the softness of the graft decreases a compliance mismatch between the graft and the patient's annulus, which may prevent redetachment. Although we felt concern about redetachment of the conduit due to the weakness of the patient's aortic annulus, no complication regarding the allograft happened at all as yet.  相似文献   

16.
Single-shot spin-echo diffusion-weighted echo-planar imaging using a phased-array multicoil was performed to distinguish between normal and cirrhotic livers. Sets of 6 images with different b-values were acquired with breath-holding. Significant differences were observed between controls and cirrhosis cases in the signal ratios when the b-value was 383 s/mm2, and apparent diffusion coefficients.  相似文献   

17.
BACKGROUND: One factor influencing the choice of mechanical versus bioprosthetic valves is reoperation for bioprosthetic valve failure. To define its operative risk, we reviewed our results with valve reoperation for bioprosthetic valve failure. METHODS: Records of 400 consecutive patients having reoperative mitral, aortic, or mitral and aortic bioprosthetic valve replacement from January 1985 to March 1997 were reviewed. RESULTS: Reoperations were for failed bioprosthetic mitral valves in 219 patients, failed aortic valves in 153 patients, and failed aortic and mitral valves in 28 patients. Including 26 operations (6%) for acute endocarditis, 153 operations (38%) were nonelective. One hundred nine patients (27%) had other valves repaired or replaced, and 72 (18%) had coronary bypass grafting. The incidence of death in the mitral, aortic, and double-valve groups was respectively, 15 (6.8%), 12 (7.8%), and 4 (14.3%); and the incidence of prolonged postoperative hospital stay (>14 days) was, respectively, 57 (26.0%), 41 (26.8%), and 8 (28.6%). Only 7 of 147 patients (4.8%) having elective, isolated, first-time valve reoperation died. Multivariable predictors (p < 0.05) of hospital death were age greater than 65 years, male sex, renal insufficiency, and nonelective operation; and predictors of prolonged stay were acute endocarditis, renal insufficiency, any concurrent cardiac operation, and elevated pulmonary artery systolic pressure. CONCLUSIONS: Reoperative bioprosthetic valve replacement can be performed with acceptable mortality and hospital stay. The best results are achieved with elective valve replacement, without concurrent cardiac procedures.  相似文献   

18.
We experienced two cases of iatrogenic left main coronary artery stenosis (IOCS) following double (aortic and mitral) valve replacement (DVR). The solid coronary perfusion catheter may attribute IOCS, with grave consequence. There have been no IOCS since the time we exchanged a solid catheter for a soft one. One case, she was successfully treated percutaneous transluminal coronary angioplasty (PTCA), because she developed angina pectoris about 5 years after PTCA. But she developed angina pectoris again and angiographically left main coronary was severe stenotic. So she was undergone aorto coronary bypass grafting (CABG) to the left anterior descending. The other case, he developed angina pectoris about 3 months after DVR. He was treated with PTCA. Angiographically left mine coronary artery stenosis reduced 50% from 90%. Generally the treatment of IOCS is CABG, but we performed PTCA for 2 patients. Because we thought it was very hazardous for us to perform them open heart surgery. When it is very hazardous to perform patients open heart surgery, they need to be performed PTCA.  相似文献   

19.
BACKGROUND: Long-term results after aortic value replacement for aortic stenosis can be correlated to a cardiac-related pre-operative risk profile. This predictability indicates that there is a common basis in subtle or overt structural abnormalities of left ventricular myocardium. METHODS AND RESULTS: Forty-nine patients aged 24-82 (mean 61) years, with aortic stenosis had a full wall thickness transmural biopsy of the left ventricular antero-lateral free wall during aortic valve replacement. Echocardiography and radionuclide ventriculography were performed prior to, and 18 months (n = 41) after, the operation. Postoperative follow-up to a maximum of 7.7 years was 100% complete. Pre-operatively, all patients had an increase in both the left ventricular mass index (202 +/- 67 g.m-2) and the muscle cell diameter (41 +/- 8 microns); other morphological data included a muscle cell nucleus volume of 752 +/- 192 microns3, a muscle cell mass index of 163 +/- 54.m-2, and a fibrous tissue mass index of 39 +/- 16 g.m-2. Patients with a pre-operative episode of clinical left ventricular failure (n = 19) had significantly greater morphological variables than those without. Pre-operative ejection fraction and other measures of systolic function correlated inversely with the morphological data, except for the fibrous tissue mass index; diastolic function indices correlated inversely with all the morphological variables. At the 18-month re-study, the same general picture was noted, but with an underlying strengthening, especially of the muscle cell mass index. Overall, the mass index dropped to 152 +/- 51 g.m-2 (P < 0.0001), but in 17% of the patients it became normal; the mass index at 18 months was directly correlated to morphological variables. A high muscle cell nucleus volume was identified as an independent predictor of early and late mortality. CONCLUSIONS: Abnormalities of the hypertrophied left ventricular muscle cell and the degree of muscle hypertrophy are, to some degree, underlying determinants of pre-operative symptomatology, pre- and postoperative ventricular function, and early and late mortality after valve replacement for aortic stenosis. Incomplete hypertrophy impaired results, was related to pre-operative myocardial structural abnormalities.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号