共查询到20条相似文献,搜索用时 31 毫秒
1.
Ultrafine particles and black carbon personal exposures in asthmatic and non‐asthmatic children at school age 下载免费PDF全文
P. Pañella M. Casas D. Donaire‐Gonzalez R. Garcia‐Esteban O. Robinson A. Valentín J. Gulliver I. Momas M. Nieuwenhuijsen M. Vrijheid J. Sunyer 《Indoor air》2017,27(5):891-899
Traffic‐related air pollution (TRAP) exposure during childhood is associated with asthma; however, the contribution of the different TRAP pollutants in each microenvironment (home, school, transportation, others) in asthmatic and non‐asthmatic children is unknown. Daily (24‐h) personal black carbon (BC), ultrafine particle (UFP), and alveolar lung‐deposited surface area (LDSA) individual exposure measurements were obtained from 100 children (29 past and 21 current asthmatics, 50 non‐asthmatics) aged 9±0.7 years from the INMA‐Sabadell cohort (Catalonia, Spain). Time spent in each microenvironment was derived by the geolocation provided by the smartphone and a new spatiotemporal map‐matching algorithm. Asthmatics and non‐asthmatics spent the same amount of time at home (60% and 61%, respectively), at school (20% and 23%), on transportation (8% and 7%), and in other microenvironments (7% and 5%). The highest concentrations of all TRAPs were attributed to transportation. No differences in TRAP concentrations were found overall or by type of microenvironment between asthmatics and non‐asthmatics, nor when considering past and current asthmatics, separately. In conclusion, asthmatic and non‐asthmatic children had a similar time‐activity pattern and similar average exposures to BC, UFP, and LDSA concentrations. This suggests that interventions should be tailored to general population, rather than to subgroups defined by disease. 相似文献
2.
The aim of this work was to assess ultrafine particles (UFP) number concentrations in different microenvironments of Portuguese preschools and to estimate the respective exposure doses of UFP for 3–5‐year‐old children (in comparison with adults). UFP were sampled both indoors and outdoors in two urban (US1, US2) and one rural (RS1) preschool located in north of Portugal for 31 days. Total levels of indoor UFP were significantly higher at the urban preschools (mean of 1.82 × 104 and 1.32 × 104 particles/cm3 at US1 an US2, respectively) than at the rural one (1.15 × 104 particles/cm3). Canteens were the indoor microenvironment with the highest UFP (mean of 5.17 × 104, 3.28 × 104, and 4.09 × 104 particles/cm3 at US1, US2, and RS1), whereas the lowest concentrations were observed in classrooms (9.31 × 103, 11.3 × 103, and 7.14 × 103 particles/cm3 at US1, US2, and RS1). Mean indoor/outdoor ratios (I/O) of UFP at three preschools were lower than 1 (0.54–0.93), indicating that outdoor emissions significantly contributed to UFP indoors. Significant correlations were obtained between temperature, wind speed, relative humidity, solar radiation, and ambient UFP number concentrations. The estimated exposure doses were higher in children attending urban preschools; 3–5‐year‐old children were exposed to 4–6 times higher UFP doses than adults with similar daily schedules. 相似文献
3.
Kirsten Koehler Nicholas Good Ander Wilson Anna Mlter Brianna F. Moore Taylor Carpenter Jennifer L. Peel John Volckens 《Indoor air》2019,29(2):231-241
This study investigated the role of microenvironment on personal exposures to black carbon (BC), fine particulate mass (PM2.5), carbon monoxide (CO), and particle number concentration (PNC) among adult residents of Fort Collins, Colorado, USA. Forty‐four participants carried a backpack containing personal monitoring instruments for eight nonconsecutive 24‐hour periods. Exposures were apportioned into five microenvironments: Home, Work, Transit, Eateries, and Other. Personal exposures exhibited wide heterogeneity that was dominated by within‐person variability (both day‐to‐day and between microenvironment variability). Linear mixed‐effects models were used to compare mean personal exposures in each microenvironment, while accounting for possible within‐person correlation. Mean personal exposures during Transit and at Eateries tended to be higher than exposures at Home, where participants spent the majority of their time. Compared to Home, mean exposures to BC in Transit were, on average, 129% [95% confidence interval: 101% 162%] higher and exposures to PNC were 180% [101% 289%] higher in Eateries. 相似文献
4.
Melissa Hachem Lynda Bensefa-Colas Nathalie Lahoud Marwan Akel Isabelle Momas Nadine Saleh 《Indoor air》2020,30(6):1308-1316
Taxi drivers’ exposure to traffic-related air pollutants inside their vehicles has been reported in different countries but not yet in Lebanon. Thus, we conducted a cross-sectional study on 20 Lebanese taxi drivers to (1) assess their exposure to ultrafine particles (UFP) and black carbon (BC) inside their vehicles and (2) identify determinants of this exposure. UFP and BC were measured using Diffusion Size Classifier Miniature® and microAeth ® Model AE51, respectively, for 5 hours. Data on characteristics of vehicles and trips were collected by face-to-face interviews. Associations between pollutant levels and their determinants were analyzed by multiple linear regression. The mean of UFP count (35.2 ± 17.6 x 103 particles cm-3) and BC (5.2 ± 1.9 μg m-3) concentrations in-taxis was higher in the morning measurements compared with those in the afternoon measurements. UFP count increased in-taxis by 60% for every 10 minutes spent in blocked traffic and by 84% starting from two trips with smokers compared to trips without smokers. Conversely, UFP count decreased by 30% for every 10 minutes under both air-conditioning and air recirculation mode with windows closed. BC was not affected by any of these factors. Our findings suggest easy ways to reduce UFP exposure inside vehicles for all commuters. 相似文献
5.
Chanjuan Sun Shijie Hong Guangkai Cai Yinping Zhang Haidong Kan Zhuohui Zhao Furong Deng Bin Zhao Xiangang Zeng Yuexia Sun Hua Qian Wei Liu Jinhan Mo Jianguo Guo Xiaohong Zheng Chunxiao Su Zhijun Zou Hao Li Chen Huang 《Indoor air》2021,31(6):1691-1706
Indoor ammonia (NH3) pollution has been paid more and more attention in view of its health risk. However, few studies have investigated the exposure level in the non-occupational environment in China. This study systematically reviewed the indoor ammonia exposure level in different regions, the equivalent exposure concentration of different populations, and the factors that influence indoor air ammonia in residences, offices, and schools in China. The literature published in 1980–2019 from main databases was searched and detailed screened, and finally, 56 related studies were selected. The results illustrated that the median concentration of indoor air ammonia in residences, offices, and school buildings was 0.21 mg/m3, 0.26 mg/m3, and 0.15 mg/m3. There were 46.4%, 71.4%, and 40% of these samples exceeding the NH3 standard, respectively. The national concentrations and the equivalent exposure levels of adults and children were calculated and found to be higher than 0.20 mg/m3. The concentration of ammonia varied greatly in different climate zones and economic development regions. Higher concentrations were found in the severe cold zone and the regions with higher economic level. This review reveals a high exposure risk of indoor air ammonia and the crucial impact of human emission, indoor air temperature, new concrete, and economic level, suggesting further investigation on indoor air ammonia evaluation and health effects. 相似文献
6.
Mehdi Amouei Torkmahalleh Zhuldyz Zhigulina Tomiris Madiyarova Kamila Turganova Enoch K. Adotey Sergei Sabanov 《Indoor air》2021,31(4):1178-1186
Children in preschools were studied as an exceptionally vulnerable group to lung diseases due to their immature immune system. Few data are available in the literature addressing the exposure of children in preschools to ultrafine (>10 nm) particles. Exposure of children to fine, ultrafine (10 nm–1 µm) particles and black carbon particles present inside and near two preschools in Nur-Sultan, Kazakhstan, during Fall 2019 was investigated. For Preschool I, the average daily (6 h) indoor (outdoor) PM1, PM2.5, and PM10 concentrations over three-week measurements were 15.0 (SD 12.5) µg/m3, 34.6 (SD 35.1) µg/m3, and 47.2 (SD 45.2) µg/m3, respectively. Average indoor UFP concentrations (>10.0 nm) including candle burning events were 5.20 × 103 (SD 8.80 × 103) particles/cm3, with the background UFP concentration to be 3.30 × 103 (SD 1.80 × 103) particles/cm3. In Preschool II, the average UFP concentration (>30.0 nm) in the morning and afternoon was 3.94 × 103 (SD 5.34 × 102) and 3.36 × 103 (SD 1.90 × 103) particles/cm3, respectively. Indoor black carbon (BC) concentrations were correlated with the outdoor smoking activity. The major sources of the indoor particles in the preschools were dust resuspension, candle burning, and infiltrated outdoor particles. 相似文献
7.
Personal measurement of exposure to black carbon and ultrafine particles in schoolchildren from PARIS cohort (Paris,France) 下载免费PDF全文
This study aimed to measure in French children personal exposure concentrations of black carbon (BC) and ultrafine particles (UFP) and to quantify the contribution of different microenvironments (home, school, places of extracurricular activities, transport) to their total exposure. It was conducted on 96 9‐year‐old children from the PARIS birth cohort. BC and UFP were continuously measured by portable devices (microAeth® AE51 and DiSCmini®) for a minimum of 24 hours, while participating families simultaneously filled in a space‐time‐activities‐budget questionnaire. BC exposure concentration was higher during trips (principally metro/train and bus), while UFP exposure concentration was higher during indoor activities (mainly eating at restaurants) and in trips. The most important UFP peaks were measured at home, especially during cooking. Home and school together accounted for much of the total exposure, 83.8% for BC and 85.3% for UFP. The contribution of transport to total exposure was 12.4% for BC and 9.7% for UFP, while extracurricular activities were responsible for 3.8% and 5% of the total exposure to BC and UFP, respectively. 相似文献
8.
This study presents real-time concentrations of traffic-related air pollutants during 499 trips conducted by 50 Parisian taxi drivers from PUF-TAXI project. Ultrafine particles (UFP), black carbon (BC), and nitrogen dioxide (NO2)/carbon monoxide (CO) were measured inside vehicles by Diffusion Size Classifier Miniature®, microAeth®, and Gas-Pro®, respectively, for nine hours. Vehicle/trip data characteristics were collected by questionnaires and on ambient conditions by monitoring stations. The associations between pollutant levels and their potential determinants were analyzed using generalized estimating equation model. Determinants of in-vehicle pollutants levels were identified: (1) ambient factors (meteorology and ambient pollution)—affecting BC, NO2, and CO; (2) vehicle characteristics—affecting all pollutants; and (3) trip-related driving habits—affecting UFP, BC, and CO. We highlight that commuters can, therefore, avoid high in-vehicle air pollutant concentrations mainly by (1) closing windows and activating air-conditioning under air recirculation mode in congested traffic; (2) smooth driving; and (3) maintaining cabin air filters. 相似文献
9.
Response of consumer and research grade indoor air quality monitors to residential sources of fine particles 下载免费PDF全文
The ability to inexpensively monitor PM2.5 to identify sources and enable controls would advance residential indoor air quality (IAQ) management. Consumer IAQ monitors incorporating low‐cost optical particle sensors and connections with smart home platforms could provide this service if they reliably detect PM2.5 in homes. In this study, particles from typical residential sources were generated in a 120 m3 laboratory and time‐concentration profiles were measured with 7 consumer monitors (2‐3 units each), 2 research monitors (Thermo pDR‐1500, MetOne BT‐645), a Grimm Mini Wide‐Range Aerosol Spectrometer (GRM), and a Tapered Element Oscillating Microbalance with Filter Dynamic Measurement System (FDMS), a Federal Equivalent Method for PM2.5. Sources included recreational combustion (candles, cigarettes, incense), cooking activities, an unfiltered ultrasonic humidifier, and dust. FDMS measurements, filter samples, and known densities were used to adjust the GRM to obtain time‐resolved mass concentrations. Data from the research monitors and 4 of the consumer monitors—AirBeam, AirVisual, Foobot, Purple Air—were time correlated and within a factor of 2 of the estimated mass concentrations for most sources. All 7 of the consumer and both research monitors substantially under‐reported or missed events for which the emitted mass was comprised of particles smaller than 0.3 μm diameter. 相似文献
10.
Kangqi Guo Hua Qian Dongliang Zhao Jin Ye Yinping Zhang Haidong Kan Zhuohui Zhao Furong Deng Chen Huang Bin Zhao Xiangang Zeng Yuexia Sun Wei Liu Jinhan Mo Chanjuan Sun Jianguo Guo Xiaohong Zheng 《Indoor air》2020,30(6):1147-1165
Microbes in buildings have attracted extensive attention from both the research community and the general public due to their close relationship with human health. However, there still lacks comprehensive information on the indoor exposure level of microbes in China. This study systematically reviews exposure levels, the community structures, and the impact factors of airborne bacteria and fungi in residences, schools, and offices in China. We reviewed the major literature databases between 1980 and 2019 and selected 55 original studies based on a set of criteria. Results show that the concentration of indoor bacteria varies from 72.5 to 7500 CFU/m3, with a median value of 1000 CFU/m3, and the concentration of fungi varies from 12 to 9730 CFU/m3, with a median value of 526 CFU/m3. The concentration level of microbes varies in different climate zones, with higher bacterial concentrations in the severe cold zone, and higher fungal concentrations in the hot summer and warm winter zone. Among different buildings, classrooms have the highest average bacteria and fungi levels. This review reveals that a unified assessment system based on health effects is needed for evaluating the exposure levels of bacteria and fungi. 相似文献
11.
Yutong Zhu Xiaoming Song Rongshan Wu Jiakun Fang Lingyan Liu Tong Wang Shuo Liu Hongbing Xu Wei Huang 《Indoor air》2021,31(6):1707-1721
Improving air quality in indoor environments where people live is of importance to protect human health. In this systematic review, we assessed the effectiveness of personal-level use of air filtration units in reducing indoor particulate matters (PM) concentrations under real-world situations following systematic review guidelines. A total of 54 articles were included in the review, in which 20 randomized controlled/crossover trials that reported the changes in indoor fine PM (PM2.5) concentrations were quantitatively assessed in meta-analysis. Standardized mean differences (SMDs) were calculated for changes in indoor PM concentrations following air filtration interventions. Moderate-to-large reductions of 11%–82% in indoor PM2.5 concentrations were observed with SMD of −1.19 (95% CI: −1.50, −0.88). The reductions in indoor PM concentrations varied by geographical locations, filtration technology employed, indoor environmental characteristics, and air pollution sources. Most studies were graded with low-to-moderate risk of bias; however, the overall certainty of evidence for indoor PM concentration reductions was graded at very low level. Considering the effectiveness of indoor air filtration under practical uses, socio-economic disparities across study populations, and costs of air filter replacement over time, our results highlight the importance of reducing air pollution exposure at the sources. 相似文献
12.
Estimating personal exposure to air pollution is a crucial component in identifying high-risk populations and situations. It will enable policy makers to determine efficient control strategies. Cycling is again becoming a favorite mode of transport both in developing and in developed countries due to increasing traffic congestion and environmental concerns. In Europe, it is also seen as a healthy sports activity. However, due to high levels of hazardous pollutants in the present day road microenvironment the cyclist might be at a higher health risk due to higher breathing rate and proximity to the vehicular exhaust.In this paper we present estimates of the exposure of a cyclist to particles of various size fractions including ultrafine particles (UFP) in the town of Mol (Flanders, Belgium). The results indicate relatively higher UFP concentration exposure during morning office hours and moderate UFP levels during afternoon. The major sources of UFP and PM10 were identified, which are vehicular emission and construction activities, respectively. We also present a dust mapping technique which can be a useful tool for town planners and local policy makers. 相似文献
13.
A major source of human exposure to ultrafine particles is candle use. Candles produce ultrafine particles in the size range under 10 nm, with perhaps half of the particles less than 5 nm. For these small particles at typically high concentrations, coagulation and deposition are two dominant mechanisms in aerosol size dynamics. We present an updated coagulation model capable of characterizing the relative contributions of coagulation, deposition, and air exchange rates. Size‐resolved coagulation and decay rates are estimated for three types of candles. Number, area, and mass distributions are provided for 93 particle sizes from 2.33 to 64 nm. Total particle production was in the range of 1013 min?1. Peak number, area, and mass concentrations occurred at particle sizes of <3, 20, and 40 nm, respectively. Both the number and area concentrations greatly exceeded background concentrations in the residence studied. Contributions of coagulation, deposition, and air exchange rates to particle losses were 65%, 34%, and 0.3% at high concentrations (106 cm?3), while they are 17%, 81%, and 1.7% at lower concentrations (3 × 104 cm?3), respectively. The increased particle production for the very smallest particles (2.33‐2.50 nm) suggests that even smaller particles may be important to study. 相似文献
14.
Shengbing Huang Chunmei Guo Ranran Qie Minghui Han Xiaoyan Wu Yanyan Zhang Xingjin Yang Yifei Feng Yang Li Yuying Wu Dechen Liu Liang Sun Dongsheng Hu Yang Zhao 《Indoor air》2021,31(6):1722-1732
Although solid fuel use has been increasingly linked to cardiovascular events (CVEs), conclusions have been inconsistent. We systematically searched 3 databases (PubMed, Embase, and Web of Science) up to July 3, 2020, to identify English language reports that assessed the association of solid fuel use with CVEs. Summary relative risks (RRs) and 95% confidence intervals (CIs) were estimated with a random-effects model. Subgroup analyses and sensitivity analyses were conducted to explore the potential sources of heterogeneity and to test the stability of the results. We finally included 13 observational studies (8 cohort, 3 cross-sectional, and 2 case-control studies comprising 791,220 participants) in the meta-analysis. The risk of CVEs was increased 21% with the highest versus the lowest solid fuel use (highest/lowest, RRpooled = 1.21, 95% CI: 1.10–1.34). As for the subgroup analyses on study design, the pooled RR for cohort studies, case-control studies, and cross-sectional studies were 1.11 (95%CI: 1.03–1.19), 4.80 (95%CI: 2.22–10.39), and 1.46 (95%CI: 0.82–2.62), respectively. The results of this study suggested that high solid fuel use was associated with increased CVE risk, and that reducing the use of solid fuel will be important for improving the health of the populations in developing countries. 相似文献
15.
Vanessa J. Burrowes Ricardo Piedrahita Ajay Pillarisetti Lindsay J. Underhill Magdalena Fandiño-Del-Rio Michael Johnson Josiah L. Kephart Stella M. Hartinger Kyle Steenland Luke Naeher Katie Kearns Jennifer L. Peel Maggie L. Clark William Checkley HAPIN Investigators 《Indoor air》2020,30(3):445-458
Assessment of personal exposure to PM2.5 is critical for understanding intervention effectiveness and exposure-response relationships in household air pollution studies. In this pilot study, we compared PM2.5 concentrations obtained from two next-generation personal exposure monitors (the Enhanced Children MicroPEM or ECM; and the Ultrasonic Personal Air Sampler or UPAS) to those obtained with a traditional Triplex Cyclone and SKC Air Pump (a gravimetric cyclone/pump sampler). We co-located cyclone/pumps with an ECM and UPAS to obtain 24-hour kitchen concentrations and personal exposure measurements. We measured Spearmen correlations and evaluated agreement using the Bland-Altman method. We obtained 215 filters from 72 ECM and 71 UPAS co-locations. Overall, the ECM and the UPAS had similar correlation (ECM ρ = 0.91 vs UPAS ρ = 0.88) and agreement (ECM mean difference of 121.7 µg/m3 vs UPAS mean difference of 93.9 µg/m3) with overlapping confidence intervals when compared against the cyclone/pump. When adjusted for the limit of detection, agreement between the devices and the cyclone/pump was also similar for all samples (ECM mean difference of 68.8 µg/m3 vs UPAS mean difference of 65.4 µg/m3) and personal exposure samples (ECM mean difference of −3.8 µg/m3 vs UPAS mean difference of −12.9 µg/m3). Both the ECM and UPAS produced comparable measurements when compared against a cyclone/pump setup. 相似文献
16.
17.
Acute health effects of desktop 3D printing (fused deposition modeling) using acrylonitrile butadiene styrene and polylactic acid materials: An experimental exposure study in human volunteers 下载免费PDF全文
I. Gümperlein E. Fischer G. Dietrich‐Gümperlein S. Karrasch D. Nowak R. A. Jörres R. Schierl 《Indoor air》2018,28(4):611-623
3D printers are increasingly run at home. Nanoparticle emissions from those printers have been reported, which raises the question whether adverse health effects from ultrafine particles (UFP) can be elicited by 3D printers. We exposed 26 healthy adults in a single‐blinded, randomized, cross‐over design to emissions of a desktop 3D printer using fused deposition modeling (FDM) for 1 hour (high UFP‐emitting acrylonitrile butadiene styrene [ABS] vs low‐emitting polylactic acid [PLA]). Before and after exposures, cytokines (IL‐1β, IL‐6, TNF‐α, INF‐γ) and ECP in nasal secretions, exhaled nitric oxide (FeNO), urinary 8‐isoprostaglandin F2α (8‐iso PGF2α), and self‐reported symptoms were assessed. The exposures had no significant differential effect on 8‐iso PGF2α and nasal biomarkers. However, there was a difference (P < .05) in the time course of FeNO, with higher levels after ABS exposure. Moreover, indisposition and odor nuisance were increased for ABS exposure. These data suggest that 1 hour of exposure to 3D printer emissions had no acute effect on inflammatory markers in nasal secretions and urine. The slight relative increase in FeNO after ABS printing compared to PLA might be due to eosinophilic inflammation from inhaled UFP particles. This possibility should be investigated in further studies using additional biomarkers and longer observation periods. 相似文献
18.
A comparison between tracer gas and aerosol particles distribution indoors: The impact of ventilation rate,interaction of airflows,and presence of objects 下载免费PDF全文
The study investigated the separate and combined effects of ventilation rate, free convection flow produced by a thermal manikin, and the presence of objects on the distribution of tracer gas and particles in indoor air. The concentration of aerosol particles and tracer gas was measured in a test room with mixing ventilation. Three layouts were arranged: an empty room, an office room with an occupant sitting in front of a table, and a single‐bed hospital room. The room occupant was simulated by a thermal manikin. Monodisperse particles of three sizes (0.07, 0.7, and 3.5 μm) and nitrous oxide tracer gas were generated simultaneously at the same location in the room. The particles and gas concentrations were measured in the bulk room air, in the breathing zone of the manikin, and in the exhaust air. Within the breathing zone of the sitting occupant, the tracer gas emerged as reliable predictor for the exposure to all different‐sized test particles. A change in the ventilation rate did not affect the difference in concentration distribution between tracer gas and larger particle sizes. Increasing the room surface area did not influence the similarity in the dispersion of the aerosol particles and the tracer gas. 相似文献
19.
Ruolan Hu Shuxiao Wang Kristin Aunan Minjiang Zhao Lu Chen Zhaohui Liu Mette H. Hansen 《Indoor air》2019,29(3):403-412
High levels of PM2.5 exposure and associated health risks are of great concern in rural China. For this study, we used portable PM2.5 monitors for monitoring concentrations online, recorded personal time‐activity patterns, and analyzed the contribution from different microenvironments in rural areas of the Yangtze River Delta, China. The daily exposure levels of rural participants were 66 μg/m3 (SD 40) in winter and 65 μg/m3 (SD 16) in summer. Indoor exposure levels were usually higher than outdoor levels. The exposure levels during cooking in rural kitchens were 140 μg/m3 (SD 116) in winter and 121 μg/m3 (SD 70) in summer, the highest in all microenvironments. Winter and summer values were 252 μg/m3 (SD 103) and 204 μg/m3 (SD 105), respectively, for rural people using biomass for fuel, much higher than those for rural people using LPG and electricity. By combining PM2.5concentrations and time spent in different microenvironments, we found that 92% (winter) and 85% (summer) of personal exposure to PM2.5in rural areas was attributable to indoor microenvironments, of which kitchens accounted for 24% and 27%, respectively. Consequently, more effective policies and measures are needed to replace biomass fuel with LPG or electricity, which would benefit the health of the rural population in China. 相似文献
20.
Measured performance of filtration and ventilation systems for fine and ultrafine particles and ozone in an unoccupied modern California house 下载免费PDF全文
This study evaluated nine ventilation and filtration systems in an unoccupied 2006 house located 250 m downwind of the I‐80 freeway in Sacramento, California. Systems were evaluated for reducing indoor concentrations of outdoor particles in summer and fall/winter, ozone in summer, and particles from stir‐fry cooking. Air exchange rate was measured continuously. Energy use was estimated for year‐round operation in California. Exhaust ventilation without enhanced filtration provided indoor PM2.5 that was 70% lower than outdoors. Supply ventilation with MERV13 filtration provided slightly less protection, whereas supply MERV16 filtration reduced PM2.5 by 97‐98% relative to outdoors. Supply filtration systems used little energy but provided no benefits for indoor‐generated particles. Systems with MERV13‐16 filter in the recirculating heating and cooling unit (FAU) operating continuously or 20 min/h reduced PM2.5 by 93‐98%. Across all systems, removal percentages were higher for ultrafine particles and lower for black carbon, relative to PM2.5. Indoor ozone was 3‐4% of outdoors for all systems except an electronic air cleaner that produced ozone. Filtration via the FAU or portable filtration units lowered PM2.5 by 25‐75% when operated over the hour following cooking. The energy for year‐round operation of FAU filtration with an efficient blower motor was estimated at 600 kWh/year. 相似文献