首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
An analytical method for simultaneous determination of 20 trace elements in vinegar including Na, Mg, K, Ca, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, Mo, Cd, Sn, Sb, Ba and Pb by sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) with microwave digestion has been established. Sample first underwent microwave digestion with HNO3 + H2O2 followed by dilution with ultrapure water, and then, the as-obtained solution was analyzed directly by SF-ICP-MS. The matrix effects were studied in details and corrected by Sc, In and Re as the internal standard elements. Data accuracy was improved by measuring in medium-resolution mode and high-resolution mode. The applicability of the proposed method has also been validated by the analysis of reference material (NIST SRM 1643e). These results showed that the detection limit of this method is in the range of 0.002–0.34 μg/L with good precision (RSD < 3 %).  相似文献   

2.
Over the last two decades, there has been increased concern regarding the impact of some noble metals, such as Pd and Pt, on human health. These elements pollute the environment due to their widespread use as catalytic converters and in medical applications. The risk they pose to human health and the environment is still controversial; however, literature data point to diet as an important source of uptake by the human body. Within this context, the total Pd and Pt content of several Italian food commodities has been investigated. A total of 90 samples, including flour products, vegetables and foodstuffs of animal origin (meat, milk and eggs), were collected and freeze-dried. Samples were analyzed by sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) after chopping or crushing followed by freeze-drying and microwave (MW)-assisted acid digestion in a Class-100 clean-room. A mathematical approach was adopted to correct the mass signals for still unresolved interference (mDeltam = 300, 10 000). The lowest and highest concentrations of Pt, i.e. 17 and 93 ng kg(-1) (dry weight, dw), were found in vegetables and flour products, respectively. The lowest Pd level (2830 ng kg(-1) dw) was found in eggs and the highest (47 800 ng kg(-1) dw) in vegetables.  相似文献   

3.
药品及药品原料中含有的重金属及有害元素如砷、汞、铅、铬、镉等会对身体产生很大的毒副作用,而药品及药品原料中含有的必需微量元素及矿物质元素如铁、铜、锌、锰、硒、硅等摄入过量、不足也会不同程度引起人体生理的异常。因此,药品中元素检测对于药品质量控制具有重要的意义。常见药品中元素的检测方法有原子吸收光谱法、电感耦合等离子体发射光谱法、原子荧光光谱法、比色法、电感耦合等离子体质谱法等。本文对电感耦合等离子体质谱法在药品检测中的应用包括重金属及有害元素检测、微量及矿质元素检测、常规元素检测、同位素元素检测、元素形态检测进行了探讨。结果表明,电感耦合等离子体法用于药品的元素检测时,线性关系、精密度、检出限和回收率都符合检测需求。电感耦合等离子体质谱法检出限低,线性范围宽,可实现多元素同时测定和同位素元素检测,且与其他分离设备联用可用于元素形态分析,因此被广泛应用于药品的元素检测。  相似文献   

4.
《粮食与油脂》2017,(5):71-72
建立了电感耦合等离子体测定面粉中铝含量的方法。样品经加酸微波消解赶酸后,用电感耦合等离子体质谱仪进行测定。标准曲线线性范围内线性相关性不小于0.999,最低检出限为0.03 mg/kg,加标回收率为87.2%~96.2%,精密度为0.43%~1.01%。本方法操作简单、灵敏度高、回收率好。  相似文献   

5.
This paper reports the development and using of ICP-MS and ICP-OES methods for determination of major, minor and trace elements in multivitamin preparations and dietary supplements and, based on results, their classification using multivariate statistical methods.The method was optimised and evaluated with the use of “in-house” reference material, commercial reference materials and spiked samples. Macroelements (Na, K, Ca, Mg, P), microelements (Cu, Fe, Mn, Zn, Se, Cr), toxic elements (As, Cd, Pb, Ni, V) and a whole series of other elements (e.g. REEs, Ti, Au, Pt, Pd, etc.) were detected with excellent limits of detection as well as other procedure parameters suitable for the purpose of the elemental analysis.As for physiologically significant elements, contents were found as follows (mg kg−1): Ca 560-196,000, Mg 308-70,300, Na 289-74,000, K from undetectable to 28,200, Cu 28-1460, P from undetectable to 217,000, Zn 2.1-25,000, Fe 115-39,400, Mn 28-1860, Cr 0.486-26.6, Mo 0.0418-9.88, and Se 0.395-161. It was found out, if compared with recommended daily intakes, that maximally 50% Ca, 37% Mg, 3% K, 20% P, 14% Na, 100% Cu, 160% Mn, 190% Fe, 120% Zn, 24% Cr, 29% Mo and 79% Se can be obtained from one dose. Extreme samples presenting a possible health risk (Ni content nearly 200 mg kg−1) were indicated. Most of the remaining elements (e.g. REEs) were analysed in order to get reference values for nutritional preparation.  相似文献   

6.
The detection of silver in nano-plastic food packaging by microwave digestion coupled with either inductively coupled plasma atomic emission spectrometry (ICP-AES) or inductively coupled plasma mass spectrometry (ICP-MS) was investigated. Microwave digestion was optimised by trialling different acid mixtures. Both ICP-AES and ICP-MS showed good reproducibility, repeatability and recovery. For ICP-AES the limit of detection of the method (LODm) was 25.0?μg?g(-1), the limit of detection of the instrument (LODi) was 30.0?ng?ml(-1), the linear range was 0.10-10.0?μg?ml(-1). The average recoveries for blank samples spiked with silver at 100, 250 and 500?μg?g(-1) ranged from 82.53% to 87.60%, and the relative standard deviations (RSDs) were from 1.79% to 8.30%. For ICP-MS analysis the LODm was 0.75?μg?g(-1), the LODi was 0.04?ng?ml(-1), the linear range was 0.20-500.0?ng?ml(-1), the RSDs were 2.26-4.79%, and the recoveries were 78.09-92.72% (spiked concentrations of 2.5, 5.0 and 10.0?μg?g(-1)). These results indicate that the proposed method could be employed to analyse silver in nano-plastic food packaging.  相似文献   

7.
电感耦合等离子体质谱法测定蜂蜜中的微量元素   总被引:3,自引:0,他引:3  
建立了用带八极杆碰撞/反应池的电感耦合等离子体质谱仪(ORS-ICP-MS)测定蜂蜜中Na、Mg、Al、K、Ca、Cr、Mn、Fe、Ni、Cu、Zn、As、Se、Mo、Cd、Ba、Hg、Pb等18种微量元素的方法。样品用HNO3+H2O2分解后,试液直接用ORS-ICP-MS法同时上述微量元素。采用八极杆碰撞/反应池技术,在池内引入惰性气体氦气或氢气,有效地消除了多原子离子对待测元素的干扰,确定了实验的最佳测定条件。结果表明,各元素的检出限在1.05~73.45ng/L之间,加标回收率在92.2%~106.8%之间,相对标准偏差(RSD)小于2.73%。  相似文献   

8.
食用植物油中多种微量元素的快速质谱分析   总被引:1,自引:0,他引:1  
建立了微波消解-高分辨电感耦合等离子体质谱法(HR-ICP-MS)同时测定食用植物油中Mg、Al、P、Ca、Cr、Mn、Fe、Co、Ni、Cu、Zn、As、Cd、Pb等14种微量元素的方法。样品用HNO3+H2O2经微波消解并进一步用高纯水稀释后,直接用HR-ICP-MS同时测定上述微量元素。详细地研究了样品消解液所产生的基体效应,以Sc、In、Re为内标元素校正基体效应,在高分辨质谱测量模式下避免了大量的质谱干扰,确定了实验的最佳测定条件。结果表明,各元素的检出限在0.004~17.29μg/L之间,加标回收率在90.00%~110.00%之间,相对标准偏差(RSD)小于3.55%。方法与其他分析方法对照结果一致。  相似文献   

9.
符靓  唐有根  谢华林 《食品科技》2012,(8):266-270,275
建立了微波消解-高分辨电感耦合等离子体质谱法(HR-ICP-MS)同时测定食用植物油中Mg、Al、P、Ca、Cr、Mn、Fe、Co、Ni、Cu、Zn、As、Cd、Pb等14种微量元素的方法。样品用HNO3+H2O2经微波消解并进一步用高纯水稀释后,直接用HR-ICP-MS同时测定上述微量元素。详细地研究了样品消解液所产生的基体效应,以Sc、In、Re为内标元素校正基体效应,在高分辨质谱测量模式下避免了大量的质谱干扰,确定了实验的最佳测定条件。结果表明,各元素的检出限在0.004~17.29μg/L之间,加标回收率在90.00%~110.00%之间,相对标准偏差(RSD)小于3.55%。方法与其他分析方法对照结果一致。  相似文献   

10.
《食品工业科技》2013,(09):312-314
对土豆样品采用HNO3+H2O2混合酸消解体系进行微波消解处理制样,用电感耦合等离子体质谱(ICP-MS)法同时测定土豆中Na、Mg、Al、P、K、Ca、Cr、Mn、Fe、Co、Ni、Cu、Zn、As、Se、Pb共16种微量元素的含量。详细地研究了样品的前处理条件,选用Rh作内标元素校正基体效应和信号漂移,该方法对16种待测元素的检出限为0.005~0.236μg/L,通过添加标准进行加标回收,所有待测元素的回收率在92.20%~109.65%之间,相对标准偏差(RSD)均小于3.18%,结果准确可靠。该法可为土豆中微量元素的快速检测提供科学依据。   相似文献   

11.
目的建立电感耦合等离子体质谱法(inductively coupled plasma mass spectrometry,ICP-MS)测定奶粉中镉含量的分析方法。方法采用微波消解-电感耦合等离子体质谱法测定奶粉中镉的含量,进行方法的检出限、精密度、加标回收、仪器比对、方法比对、不确定度评估等实验,并且以能力验证的反馈结果对方法的准确性进行评价。结果该方法在0.5~50μg/L范围内线性关系良好,回归方程为Y=0.02545C+0.00030,相关系数0.99999,检出限为0.0008mg/kg,加标回收率在96.9%~100.2%范围,仪器比对和方法比对结果满意,能力验证奶粉中镉含量的反馈结果 Z值为-0.06。结论本方法线性关系良好,效率高,准确性好,可用于奶粉中的镉含量的测定。  相似文献   

12.
目的利用电感耦合等离子体质谱法(inductively coupled plasma mass spectrometry,ICP-MS)对固体饮料中有害元素的含量进行全面的测定和分析,为固体饮料中污染物测定和判定能够提供更合理的参考依据。方法样品经硝酸消解赶酸后,采用ICP-MS对不同类型的固体饮料中的有害元素铅、砷、镉、铬、汞、铝、铜、镍、硼元素含量进行测定,并对其来源进行研究。结果固体饮料中有害元素含量表现为AlBCuNiCrAsPbCdHg。由于茶粉的添加,茶固体饮料中铝平均含量高达49.4 mg/kg;同时由于大豆粉的添加,蛋白固体饮料中硼、铜和镍平均含量高达3.86、2.87和1.43 mg/kg。而以添加剂为主要原辅料的风味固体饮料和其他类固体饮料中9种有害元素的平均含量均低于总体的平均值。结论固体饮料中由原辅料引入的有害元素污染风险较高,而由食品添加剂引入的有害元素污染风险较低。  相似文献   

13.
本研究建立以甲醇为基体改进剂内标校正外标定量的电感耦合等离子体质谱法检测乳与乳制品中微量元素硒的含量。本研究采用微波消解前处理方法,使用电感耦合等离子体质谱仪的碰撞反应模式,内标中添加甲醇溶液为基体改进剂,通过分析微量元素硒的6个同位素的灵敏度和线性相关性,确定选择质量数 78Se 测定乳制品中的硒。同时用Minitab 中的DOE实验设计进行分析,采用 72Ge元素作内标补偿基体效应,最终以 7.5 %(V/V)的甲醇作为基体改进剂,有效的控制了硒的回收率;本研究的方法检出限为固体样品0.00737mg/kg,液体样品0.00264mg/kg,5种不同基质样品的精密度(RSD,n=6)在2.0 %~6.1 %之间,加标回收率为 81.1 %~117 %。该检测方法快速简便,精密度高,准确性好,也具有较高的灵敏度,可为乳及乳制品中微量元素硒的测定提供参考。  相似文献   

14.
目的建立电感耦合等离子体质谱法(inductively coupled plasma mass spectrometry,ICP-MS)测定预混料矿物质中碘元素。方法样品经5%氨水超声提取,通过电感耦合等离子体质谱仪,以103Rh作为在线内标,对样品溶液进行测定。结果在碘浓度为0~200μg/L的范围内,线性关系良好,线性方程为Y=8.173×10~(-4)X+1.991×10~(-4),相关系数r为0.9993。对预混料样品加入低、中、高3个梯度进行加标测定,回收率在88.6%~101.0%之间,相对标准偏差小于2.3%(n=3)。结论该方法准确、便捷、回收率良好,适用于不同预混料矿物质中碘含量的测定。  相似文献   

15.
建立了电感耦合等离子体质谱(ICP-MS)法直接测定奶酪中Cr、Mn、Co、Ni、Cu、Zn、As、Se、Mo、Cd、Hg、Pb等12种微量元素的分析方法。奶酪经正丙醇+二甲苯(70∶30,v/v)稀释后直接进入ICP-MS进行分析,该有机样品液可以长时间保持稳定以满足多元素的测定要求,在等离子体中引入少量氧气,以防止高浓度有机样品中的碳元素在质谱采样锥锥孔沉积导致分析元素的灵敏度降低。应用数学公式法校正了质谱分析过程中形成的多原子离子对待测元素产生的干扰,采用Sc、In、Bi为内标元素校正了质谱分析中的基体效应。12种微量元素的检出限在0.843.9ng/L之间,加标回收率在90.0%109.0%之间,相对标准偏差(RSD)为1.8%3.7%。   相似文献   

16.
摘 要:目的 本文建立了电感耦合等离子体质谱法(inductively coupled plasma mass spectrometry,ICP-MS)同时测定 Na、K、Mg、Ca、Al、Fe、Cr、Mn、Co、Cu、Zn、As、Se、Mo、Cd、Pb、Hg等 17 种无机元素的分析方法。方法 样品微波消解后,选用Rh为内标元素校正基体效应,用电感耦合等离子体质谱法进行分析。结果 结果表明:所测17种元素的相关系数均不小于 0.9990,加标回收率在 82.8%~111.0%之间,相对标准偏差RSD在1.0%~7.1%之间。结论 该方法快捷准确,可用于牡蛎多种无机元素同时检测。  相似文献   

17.
目的优化电感耦合等离子质谱法测定二氧化钛的含量。方法样品前处理先通过硫酸湿法消解,放冷后再用加入30%过氧化氢继续消解,用电感耦合等离子质谱法测定二氧化钛中钛含量,根据质量分数计算出二氧化钛含量。结果通过比较微波消解、湿法消解、干灰化法消解和压力消解4种前处理方式,采用硫酸-双氧水的消解体系进行湿法消解。钛在0~50μg/mL范围内线性关系良好,相关系数为1.0000。在50、75和100 g/100mL 3个加标浓度下,样品的平均回收率为101.26%,平均相对标准偏差为2.8%。结论该方法简便、快捷,有较高的灵敏度、准确度、精密度,适合食品中二氧化钛含量的测定。  相似文献   

18.
对土豆样品采用HNO3+H2O2混合酸消解体系进行微波消解处理制样,用电感耦合等离子体质谱(ICP-MS)法同时测定土豆中Na、Mg、Al、P、K、Ca、Cr、Mn、Fe、Co、Ni、Cu、Zn、As、Se、Pb共16种微量元素的含量.详细地研究了样品的前处理条件,选用Rh作内标元素校正基体效应和信号漂移,该方法对16种待测元素的检出限为0.005 ~0.236μg/L,通过添加标准进行加标回收,所有待测元素的回收率在92.20%~109.65%之间,相对标准偏差(RSD)均小于3.18%,结果准确可靠.该法可为土豆中微量元素的快速检测提供科学依据.  相似文献   

19.
目的建立电感耦合等离子体质谱法检测保健食品中硅含量的分析方法。方法将保健食品类试样进行灰化,加入氢氧化钠形成共熔体,将共熔体与水混合,得到溶解液,采用电感耦合等离子体质谱法对溶解液进行硅含量检测。通过加标回收率和国家标准物质的分析实验验证该方法的准确性和可靠性。结果实验标准曲线的线性范围在0.0~10.0μg/mL,回归方程的相关系数达到1.0000。方法的检出限为0.050 mg/L,标准物质加标回收率在96.4%~103.3%,精密度小于2.5%;国家标准物质柑橘叶和紫菜测定值均在标准值允许的范围内。结论该方法具有快速、批量、灵敏度高的特点,适用于保健食品中硅含量的测定。  相似文献   

20.
电感耦合等离子体质谱法联用技术应用研究进展   总被引:1,自引:0,他引:1  
本文归纳了近十年来电感耦合等离子体质谱法(inductively coupled plasma-mass spectrometry,ICP-MS)的最新联用技术进展,主要阐述了ICP-MS与毛细管电泳(capillary electrophoresis,CE)、高效液相色谱(high performance liquid chromatography,HPLC)、气相色谱(gas chromatography,GC)、离子色谱(ion chromatography,IC)、流动注射(flow injection,FI)、电热蒸发(electric heating evaporation,ETV)、激光烧蚀(laser ablation,LA)和氢化物发生(hydride,HG)的联用技术研究进展,对各种联用技术的特点及应用进行了归纳,最后对电感耦合等离子体质谱的联用发展前景进行了展望。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号