首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
The retention and overloading behavior of some basic (and acidic) compounds has been studied on different RP-HPLC columns in buffers of varying ionic strength. Anomalous retention patterns of acids and bases were found on one phase in low-pH, volatile buffers such as formic acid, favored for mass spectrometric analysis. Unusual retention compared to that in higher ionic strength phosphate buffers is attributed to the presence of positively charged sites existing on this phase at low pH. Overloading of bases as well as acids is shown to be a function of mobile-phase ionic strength. This result is a logical consequence of previous suggestions that mutual repulsion of ions held on the hydrophobic surface of the stationary phase, rather than overload of silanols, is largely responsible for overloading on pure silica RP columns. Thus, overloading occurs much more readily in low ionic strength formic acid buffers. Appreciable loss of efficiency can occur in such buffers when only 50 ng of some bases is analyzed on a standard-sized column.  相似文献   

2.
A new approach for the synthesis of long alkyl chain length stationary phases for use in reversed-phase liquid chromatography is described. Poly(ethylene-co-acrylic acid) copolymers (i.e., (-CH2CH2-)x[CH2CH(CO2H)-]y) with different levels of acrylic acid were covalently bonded to silica via glycidoxypropyl or aminopropyl linkages. 13C cross polarization magic angle spinning (CP/MAS) nuclear magnetic resonance (NMR) spectroscopy was used to characterize the new reversed-phase materials. Aspects of shape selectivity were evaluated for six different columns with Standard Reference Material (SRM) 869a, Column Selectivity Test Mixture for Liquid Chromatography. Selectivity for isomer separations was enhanced for stationary phases prepared with poly(ethylene-co-acrylic acid) containing a mass fraction of 5% acrylic acid. The relationship between alkyl conformation and chromatographic properties was studied by 13C magic angle spinning (MAS) NMR measurements, and correlations were made with the composition of the polymer. Finally, the effectiveness of this phase is demonstrated by the separation of several beta-carotene isomers.  相似文献   

3.
The retention properties of eight alkyl, aromatic, and fluorinated reversed-phase high-performance liquid chromatography bonded phases were characterized through the use of linear solvation energy relationships (LSERs). The stationary phases were investigated in a series of methanol/water mobile phases. LSER results show that solute molecular size and hydrogen bond acceptor basicity under all conditions are the two dominant retention controlling factors and that these two factors are linearly correlated when either different stationary phases at a fixed mobile-phase composition or different mobile-phase compositions at a fixed stationary phase are considered. The large variation in the dependence of retention on solute molecular volume as only the stationary phase is changed indicates that the dispersive interactions between nonpolar solutes and the stationary phase are quite significant relative to the energy of the mobile-phase cavity formation process. PCA results indicate that one PCA factor is required to explain the data when stationary phases of the same chemical nature (alkyl, aromatic, and fluoroalkyl phases) are individually considered. However, three PCA factors are not quite sufficient to explain the whole data set for the three classes of stationary phases. Despite this, the average standard deviation obtained by the use of these principal component factors are significantly smaller than the average standard deviation obtained by the LSER approach. In addition, selectivities predicted through the LSER equation are not in complete agreement with experimental results. These results show that the LSER model does not properly account for all molecular interactions involved in RP-HPLC. The failure could reside in the V2 solute parameter used to account for both dispersive and cohesive interactions since "shape selectivity" predictions for a pair of structural isomers are very bad.  相似文献   

4.
High-performance immobilized-metal affinity and hydroxyapatite chromatography were employed to investigate the engineered subtilisin S1 binding site microenvironment. Although these methods are classified as affinity techniques, unlike traditional affinity columns, both are capable of probing the entire surface of a molecule. The metal chelate study employed gradient elution to assemble retention maps for a wide range of mobile-phase pH. Resolution of single substitution variants was achieved at the optimum mobile-phase pH. A total of four metals were applied separately to the metal chelate column to investigate ligand specificity with respect to protein retention. Hydroxyapatite chromatography, albeit an established technique, has only recently been developed as a high-performance chromatographic method. Gradient elution separations were performed to determine selectivity. Immobilized-metal affinity chromatography was found to be the more effective method for the separation of site-specific variants.  相似文献   

5.
A high-performance liquid chromatography (HPLC) method using a fused-core silica particle packing was evaluated to allow fast and efficient separation for the analysis of pharmaceutical compounds. Fused-core particles are produced by "fusing" a porous silica layer onto a solid silica particle. The efficiencies of columns packed with 2.7 microm "fused-core" particles (a 0.5 microm porous shell fused to a solid 1.7 microm silica core particle) and 1.7 microm porous particles were compared in reversed-phase HPLC using rimonabant as an analyte. The fused-core silica materials providing the shorter diffusional mass transfer path for solutes are less affected in resolving power by increases in mobile-phase velocity than the sub-2 microm porous silica packings resulting in faster separations and higher sample throughput. This fast HPLC technology is comparable with ultrahigh-pressure liquid chromatography (UHPLC) in terms of chromatographic performance but demands neither expensive ultra-high-pressure instrumentation nor new laboratory protocols. The column effluent was directly connected to the atmospheric pressure chemical ionization (APCI) source prior to tandem mass spectrometric detection. In this work, the described fast HPLC-MS/MS and UHPLC-MS/MS approaches requiring approximately 1.5 min per sample were applied and compared for the determination of the rimonabant in mouse plasma samples at the low nanograms per milliliter region in support of a pharmacodynamic study.  相似文献   

6.
Capillary-channeled polymer (C-CP) fibers are investigated as reversed-phase (RP) stationary phases for high-performance liquid chromatography of proteins. A comparative analysis of column characteristics for polypropylene and poly(ethylene terephthalate) C-CP fiber columns and a conventional packed-bed (C4-derivatized silica) column has been undertaken. Five proteins (ribonuclease A, cytochrome c, lysozyme, myoglobin, bovine serum albumin) were used to investigate the separation characteristics under typical RP gradient conditions. Column performance was compared under standard (identical) and optimized RP chromatographic conditions. The gradient compositions utilized with the C-CP fiber columns are similar to those used with conventional columns, employing flow rates in the 1-6 mL/min range and gradient rates of approximately 1%/min. The packed-bed column was operated as prescribed by the column manufacturer. The retention factor (k'), separation factor (alpha), resolution (Rs), asymmetry factor (As), elution order, and peak capacity values of a four protein separations performed on the C-CP fiber columns are compared to the same separation on the C4 column. One unique feature observed here is the lessening of the percentage of organic modifier necessary to elute the proteins from the fiber phases with increased linear velocity. The potential contribution of the different stationary phases to protein denaturation was evaluated through a spectrophotometric enzymatic activity assay. The repeatability of retention times under both sets of conditions for six consecutive injections of lysozyme on each C-CP fiber column is < or =1.5% RSD. The column-to-column reproducibility of retention times for three columns of each fiber type is also < or =1.5% RSD. The overall performance of the C-CP fiber columns was comparable to the conventional column used in these studies. Basic characteristics demonstrated here suggested further developments in the areas of ultrafast protein separations and preparative-scale protein chromatography.  相似文献   

7.
Cross-linked poly(N-isopropylacrylamide-co-acrylic acid) (poly(IPAAm-co-AAc))-grafted silica bead surfaces were prepared and applied as new column matrix materials that exploit temperature-responsive anionic chromatography to separate basic bioactive compounds, specifically catecholamine derivatives, in aqueous mobile phases. Since poly(IPAAm-co-AAc) has a well-known temperature-responsive phase transition and apparent pKa shift, polymer-grafted silica bead surfaces are expected to exhibit simultaneous hydrophilic/hydrophobic and charge density alterations under thermal stimuli. Elution behavior of catecholamine derivatives from a copolymer-modified bead packed column was monitored using aqueous mobile-phase HPLC under varying temperature and pH. Catecholamine derivatives had higher retention times on poly(IPAAm-co-AAc) columns at higher pH in comparison with those on noncharged PIPAAm reference columns, suggesting an electrostatic interaction as a separation mode. Temperature also affected the retention behavior of catecholamine derivatives. Optimal separation of four catecholamine derivatives was achieved at elevated temperature, 50 degrees C, and at pH 7.0. This is due to the increased hydrophobicity of the stationary phase as evidenced by the elution of a nonionic hydrophobic steroid. From these results, mutual influences of both electrostatic and hydrophobic interactions between basic catecholamine derivatives and pH-/temperature-responsive surfaces are noted. Consequently, elution of weakly charged bioactive compounds is readily regulated through the modulation of stationary-phase thermoresponsive hydrophilic/hydrophobic and charge density changes.  相似文献   

8.
This work characterizes solvation effects in reversed-phase liquid chromatography in the presence of 1-propanol. The solvatochromic method combined with a multivariate curve resolution-alternating least-squares analysis method has been used to characterize two modified silica surfaces--phenyl bonded and C18 bonded silica in mobile-phase mixtures of methanol--water and acetonitrile--water in the presence of 1-propanol. The presence of a small amount of 1-propanol has been shown to affect mainly the polarity properties of the stationary phases while the mobile-phase properties are largely unaffected. The chain collapse mechanism for the C18 stationary phase at higher concentrations of water seems to be inhibited in the presence of 1-propanol, and partitioning is the predominant solute retention mechanism. The phenyl-based phase shows considerably different behavior from that of the C18 phase, and propanol appears to disrupt the pi-stacking interactions between the solute and the phenyl rings anchored to the silica support.  相似文献   

9.
Overloading occurs for submicrogram quantities of ionized solutes particularly when using low ionic strength mobile phases at low pH (e.g., formic acid), even with highly inert silica RP-HPLC columns of normal dimensions. Much higher loads can produce a sharp L-shaped peak with retention above the column void volume, in line with the hypothesis that a small number of high-energy sites fill first and are rapidly overloaded, followed by a much larger number of weaker sites. However, charged acids and bases show identical overloading behavior; overloading is reduced as the mobile-phase ionic strength is increased. These findings raise questions about the physical nature of the strong sites. The rapid overloading of silica and purely polymeric phases could be explained by mutual repulsion of ionic species or their inability to fully penetrate the hydrophobic structure of the phase. However, these alternative hypotheses cannot readily explain the high total saturation capacities obtained using frontal analysis. Ion pairing with trifluoroacetic acid may reduce overload, while the effect is less important for formate or phosphate buffers. A surface layer of acetonitrile is not a prerequisite for rapid overloading, as shown by studies using purely aqueous buffers.  相似文献   

10.
Simple and comprehensive two-dimensional (2D)-HPLC was studied in a reversed-phase mode using monolithic silica columns for second-dimension (2nd-D) separation. Every fraction from the first column, 15 cm long (4.6-mm i.d.), packed with fluoroalkylsilyl-bonded (FR) silica particles, was subjected to the separation in the 2nd-D using one or two octadecylsilylated (C(18)) monolithic silica columns (4.6-mm i.d., 3 cm). Monolithic silica columns in the 2nd-D were eluted at a flow rate of up to 10 mL/min with separation time of 30 s that meets the fractionation every 15-30 s at the first dimension (1st-D) operated at a flow rate of 0.4-0.8 mL/min. Three cases were studied. (1) In the simplest scheme of 2D-HPLC, effluent of the 1st-D was directly loaded into an injector loop of 2nd-D HPLC for 28 s, and 2 s was allowed for injection. (2) Two six-port valves each having a sample loop were used to hold the effluent of the 1st-D alternately for 30 s for one 2nd-D column to effect comprehensive 2D-HPLC without the loss of 1st-D effluent. (3) Two monolithic silica columns were used for 2nd-D by using a switching valve and two sets of 2nd-D chromatographs separating each fraction of the 1st-D effluent with the two 2nd-D columns alternately. In this case, two columns of the same stationary phase (C(18)) or different phases, C(18) and (pentabromobenzyloxy)propylsilyl-bonded (PBB), could be employed at the 2nd-D, although the latter needed two complementary runs. The systems produced peak capacity of approximately 1000 in approximately 60 min in cases 1 and 2 and in approximately 30 min in case 3. The three stationary phases, FR, C(18), and PBB, showed widely different selectivity from each other, making 2D separations possible. The simple and comprehensive 2D-HPLC utilizes the stability and high efficiency at high linear velocities of monolithic silica columns.  相似文献   

11.
In reversed-phase liquid chromatography (RPLC), the retention of weak acids and bases is a sigmoidal function of the mobile-phase pH. Therefore, pH is a key chromatographic variable to optimize retention and selectivity. Furthermore, at an eluent pH close to the pKa of the solute, the dependence of ionization of the buffer and solute on temperature can be used to improve chromatographic separations involving ionizable solutes by an adequate handling of column temperature. In this paper, we derive a general equation for the prediction of the retentive behavior of ionizable compounds upon simultaneous changes in mobile-phase pH and column temperature. Four experiments, two limiting pH values and two temperatures, provide the input data that allow predictions in the whole range of these two variables, based on the thermodynamic fundamentals of the involved equilibria. Also, the study demonstrates the significant role that the choice of the buffer compound would have on selectivity factors in RPLC at temperatures higher than 25 degrees C.  相似文献   

12.
Flow-through low-pressure chromatographic separations capitalized on the sequential injection chromatographic (SIC) concept are for the first time coupled to second-order multivariate regression models based on multivariate curve resolution-alternating least-squares (MCR-ALS) for outperforming current chromatographic methods in terms of resolution efficiency. The proposed SIC-MCR-ALS method involving sequential injection separation on short monolithic columns along with isocratic elution fosters ultrafast reversed-phase separations of complex multicomponent mixtures regardless of peak overlapping and retention parameters. The ruggedness of SIC systems is enhanced by removing the solenoid valves from the flow network, thus diminishing the column back pressure effects. As a consequence, the flow setup admitted mobile-phase flow rates much higher than those traditionally enabled in SIC. To ascertain the improved peak capacity of the SIC-MCR-ALS procedure, five phenolic species commonly used in disinfectant products and featuring similar UV spectra and close retention times in short reversed-phase silica-based monolithic phases are selected as model compounds and determined in just 1 min using mobile-phase flow rates of >or=2 mL min(-1). Notwithstanding the fact that the five phenolic derivatives coelute in a single chromatographic band, thus rendering resolution values ranging from 0.05 to 1.11, the concentration profiles and the pure spectra of each individual phenol species could be concurrently obtained. Quantitative validation of the chromatographic-chemometric method demonstrated both the reliability of the results and the enhanced resolution of mixtures with regard to former SIC systems with no need for thorough optimization of the separation conditions.  相似文献   

13.
A novel fritless capillary column for capillary electrochromatography (CEC) has been developed. The ODS microspheres were packed into a capillary and were then immobilized within an organic polymer prepared in situ through a photopolymerization process. The entrapment conditions were investigated to minimize the effect of the polymer matrix on the chromatographic properties of the packing material. The organic polymer matrix in the microsphere-packed column functions to link microspheres at specific sphere-sphere and sphere-capillary contact points. CEC separations of a PAH test mixture using entrapped columns with different UV illumination times were compared in terms of retention factor and separation efficiency. The optimized entrapped column demonstrated better chromatographic performance than similarly packed columns with conventional inlet and outlet frits. The electrochromatographic separations of hormones and peptides were also demonstrated on entrapped ODS columns.  相似文献   

14.
In chromatographic separations, the heights of peaks are proportional to the concentrations of sample components present in an injected mixture. In general, an increase in the peak height cannot be achieved by simply increasing the injection time or the sample plug length. An exception occurs if some form of on-line preconcentration is possible. We present a new strategy for achieving on-line preconcentration by the use of a porous chromatographic material that acts as a solid-phase extractor as well as a stationary-phase separator. We are able to realize significant on-line preconcentration using capillary columns filled with a photopolymerized sol-gel (PSG). More than 2-cm plugs of sample solution can be loaded into the capillary and concentrated using a running buffer that is the same as the injection buffer (to avoid solvent gradient effects). As a demonstration, mixtures of three different polycyclic aromatic hydrocarbons, eight different alkyl phenyl ketones, and five different peptides in solutions of aqueous acetonitrile have been injected onto the PSG column and separated by capillary electrochromatography. The preconcentration is marked in terms of peak heights, with up to 100-fold increase for the PAH mixture, 30-fold for the alkyl phenyl ketone mixture, and 20-fold for the peptide mixture. Preconcentration takes place because of the high mass-transfer rates possible in the highly porous structure, and the extent of preconcentration follows the retention factor k for a given analyte.  相似文献   

15.
Cyclic siloxane-based silica columns of high retention capacity for light hydrocarbons were prepared by incorporation of octyl and octadecyl groups on the siloxane skeleton. Spectroscopic studies revealed the presence of the alkyl groups on the silica surface, which results in high surface coverage of the packing materials. The retention characteristics of the columns are significantly higher than those of cyclic siloxane phases due to their high surface coverage and better solute-stationary phase interactions. In agreement with previous data for micropacked columns, the H vs ū curves, on passing through the optimum region, remained substantially constant at high linear gas velocities, indicating their usefulness for fast analysis of light hydrocarbons at high flow rates without any appreciable loss in column performance. Presumably due to greater availability of the bonded alkyl groups for interactions, a 10-component mixture of C(1)-C(4) saturated and unsaturated hydrocarbons was sufficiently separated on the hexamethylcyclotrisiloxane-octadecylsilyl phase compared to the conventional octadecyldimethylsilyl phase, irrespective of the high carbon content of the latter.  相似文献   

16.
A bimodal meso/macroporous monolithic silica capillary column containing an entrapped antibody was prepared by a biocompatible sol-gel process and used for nanoflow immunoaffinity chromatography and immunoextraction studies. Stationary phases were prepared by combining the protein-compatible silane precursor diglycerylsilane with an aqueous solution containing 10,000 Da poly(ethylene glycol) and the antibody. An analytical method was developed that was capable of determining both the dissociation constant and binding site content for the anti-fluorescein antibody within the stationary phase. The assay showed that while the antibody residing in macropores was easily removed, approximately 20% of initially loaded antibody remained active and accessible after several washes, consistent with the antibody being entrapped within the mesopores of the sol-gel matrix. The dissociation constants for fluorescein binding to the anti-fluorescein antibody were similar in solution and in the meso/macroporous silica, indicating that the entrapped antibody retained its native conformation within such a matrix. The mixture was loaded into a 250-microm-i.d. fused-silica capillary where the polymer phase separated from the silica followed by gelation of the silica. The capillary-scale immunoaffinity columns could be operated at low back pressure using a syringe pump and were capable of performing chromatographic separations that were dependent on the presence of the antibody within the stationary phase. Such columns could also be operated using in-line laser-induced fluorescence detection. The use of the capillary-scale monolithic columns for on-column immunoextraction and preconcentration is also demonstrated.  相似文献   

17.
"Shape-selective" polymeric alkylsilane stationary phases are routinely employed over the more common monomeric phases in reversed-phase liquid chromatography (RPLC) to improve the separation of geometric isomers of shape-constrained solutes. We have investigated the molecular dynamics of chromatographic models that represent both monomeric and polymeric stationary phases with alkylsilane surface coverages and bonding chemistries typical of actual materials in an effort to elucidate the molecular-level structural features that control shape-selective separations. The structural characterization of these models is consistent with previous experimental observations of alkyl chain order and disorder: (1) alkyl chain order increases with increased surface coverage; and (2) monomeric and polymeric phases with similar surface coverages yield similar alkyl chain order (although subtle differences exist). In addition, a significant portion of the alkyl chain proximal to the silica surface is disordered (primarily gauche conformations) and the distal end is most ordered. Models that represent shape-selective RPLC phases possess a significant region of distal end chain order with primarily trans dihedral angle conformations. This is consistent with the view that the alkyl chains comprising polymeric stationary phases contain a series of well-defined and rigid voids in which shape-constrained solutes can penetrate and hence be selectively retained.  相似文献   

18.
It is demonstrated that the kinetic plot representation of experimental plate height data can also account for practical constraints on the column length, the peak width, the viscous heating, and the mobile-phase velocity without needing any iterative solution routine. This implies that the best possible kinetic performance to be expected from a given tested support under any possible set of practical optimization constraints can always be found using a directly responding calculation spreadsheet template. To show how the resulting constrained kinetic plots can be used as a powerful design and selection tool, the method has been applied to a series of plate height measurements performed on a number of different commercial columns for the same component (butyl-parabene) and mobile-phase composition. The method, for example, allows one to account for the fact that the advantageous solutions displayed by the silica monolith and 5 microm particle columns in the large plate number range of the free kinetic plot are no longer accessible if applying a maximal column length constraint of Lmax = 30 cm. In the plate number range that remains accessible, the investigated sub-2 mum particle columns in any case perform (at least for the presently considered parabene separation) better than the 3.5 mum particle columns or silica monolith, especially if considering the use of system pressures exceeding 400 bar. The constrained kinetic plot method can also be used to select the best-suited column length from an available product gamma to perform a separation with a preset number of plates. One of the optimization results that is obtained in this case is that sometimes a significant gain in analysis time can be obtained by selecting a longer column, yielding the desired plate number at a larger velocity than that for a shorter column.  相似文献   

19.
Micelle-mimetic ionene-based stationary phases for high-performance liquid chromatography (HPLC) are prepared by attaching [3,16]- and [3,22]-ionenes to aminopropyl silica through a carbon-nitrogen bond. These [x,y]-ionenes are polyelectrolytic molecules consisting of dimethylammonium charge centers interconnected by alternating alkyl chain segments containing x and y methylene groups, some of which can form aggregate species whose properties mimic those of conventional surfactant micelles. These ionene-bonded stationary phases were characterized using different recommended HPLC test mixtures. Test solute chromatographic behavior on the ionene phases was found to be similar to that of intermediate oligomeric or polymeric C-18 and/or phenyl phases, depending upon the specific test mixture employed. In addition, the phases exhibit significant solute shape recognition ability. The ionene stationary phases were successfully employed for the separation of the components of the recommended ASTM reversed-phase test mixture, as well as for ortho-, meta- and para-disubstituted benzenes and other positional or geometric isomeric compounds. The ionene materials allow for chromatographic separations under either reversed-phase or ion-exchange conditions. The retention mechanism on these multimodal phases can occur by hydrophobic partitioning or electrostatic interactions, depending upon the characteristics of the components of the analyte mixture (neutral or anionic). The effects of alteration of the percent organic modifier, flow rate and temperature of the mobile phase on chromatographic retention and efficiency on these phases were briefly examined.  相似文献   

20.
This work explores the use of 20-microm-i.d. polymeric polystyrene-divinylbenzene monolithic nanocapillary columns for the LC-ESI-MS analysis of tryptic digest peptide mixtures. In contrast to the packing of microparticles, capillary columns were prepared, without the need of high pressure, in fused-silica capillaries, by thermally induced in situ copolymerization of styrene and divinylbenzene. The polymerization conditions and mobile-phase composition were optimized for chromatographic performance leading to efficiencies over 100000 plates/m for peptide separations. High mass sensitivity (approximately 10 amol of peptides) in the MS and MS/MS modes using an ion trap MS was found, a factor of up to 20-fold improvement over 75-microm-i.d. nanocolumns. A wide linear dynamic range (approximately 4 orders of magnitude) was achieved, and good run-to-run and column-to-column reproducibility of isocratic and gradient elution separations were found. As samples, both model proteins and tissue extracts were employed. Gradient nano-LC-MS analysis of a proteolytic digest of a tissue extract, equivalent to a sample size of approximately 1000 cells injected, is presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号