首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
High-frame rate ultrasound imaging is necessary to track fast deformation in ultrasound elasticity imaging, but the image quality may be degraded. Previously, we investigated the performance of strain imaging using numerical models of conventional and ultrafast ultrasound imaging techniques. In this paper, we performed experimental studies to quantitatively evaluate the strain images and elasticity maps obtained using conventional and high frame rate ultrasound imaging methods. The experiments were carried out using point target and tissue mimicking phantoms. The experimental results were compared with the results of numerical simulation. Our experimental studies confirm that the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and axial/lateral resolution of the displacement and strain images acquired using high-frame rate ultrasound imaging are slightly lower but comparable with those obtained using conventional imaging. Furthermore, the quality of elasticity images also exhibits similar trends. Thus, high-frame rate ultrasound imaging can be used reliably for static elasticity imaging to capture the internal tissue motion if the frame rate is critical.  相似文献   

2.
To overcome the inherent low frame rate of conventional ultrasound, we have previously presented a system that can be implemented on conventional ultrasound scanners for high-frame-rate imaging of monochromatic tissue motion. The system employs a sector subdivision technique in the sequencer to increase the acquisition rate. To eliminate the delays introduced during data acquisition, a motion phase correction algorithm has also been introduced to create in-phase displacement images. Previous experimental results from tissue- mimicking phantoms showed that the system can achieve effective frame rates of up to a few kilohertz on conventional ultrasound systems. In this short communication, we present a new pulse sequencing strategy that facilitates high-frame-rate imaging of monochromatic motion such that the acquired echo signals are inherently in-phase. The sequencer uses the knowledge of the excitation frequency to synchronize the acquisition of the entire imaging plane to that of an external exciter. This sequencing approach eliminates any need for synchronization or phase correction and has applications in tissue elastography, which we demonstrate with tissue-mimicking phantoms.  相似文献   

3.
In ultrasound elasticity imaging, strain decorrelation is a major source of error in displacements estimated using correlation techniques. This error can be significantly decreased by reducing the correlation kernel. Additional gains in signal-to-noise ratio (SNR) are possible by filtering the correlation functions prior to displacement estimation. Tradeoffs between spatial resolution and estimate variance are discussed, and estimation in elasticity imaging is compared to traditional time-delay estimation. Simulations and experiments on gel-based phantoms are presented. The results demonstrate that high resolution, high SNR strain estimates can be computed using small correlation kernels (on the order of the autocorrelation width of the ultrasound signal) and correlation filtering.  相似文献   

4.
In tissue the Young's modulus cannot be assumed constant over a wide deformation range. For example, direct mechanical measurements on human prostate show up to a threefold increase in Young's modulus over a 10% deformation. In conventional elasticity imaging, these effects produce strain-dependent elastic contrast. Ignoring these effects generally leads to suboptimal contrast (stiffer tissues at lower strain are contrasted against softer tissues at higher strain), but measuring the nonlinear behavior results in enhanced tissue differentiation. To demonstrate the methods extracting nonlinear elastic properties, both simulations and measurements were performed on an agar-gelatin phantom. Multiple frames of phase-sensitive ultrasound data are acquired as the phantom is deformed by 12%. All interframe displacement data are brought back to the geometry of the first frame to form a three-dimensional (3-D) data set (depth, lateral, and preload dimensions). Data are fit to a 3-D second order polynomial model for each pixel that adjusts for deformation irregularities. For the phantom geometry and elastic properties considered in this paper, reconstructed frame-to-frame strain images using this model result in improved contrast to noise ratios (CNR) at all preload levels, without any sacrifice in spatial resolution. From the same model, strain hardening at all preload levels can be extracted. This is an independent contrast mechanism. Its maximum CNR occurs at 5.13% preload, and it is a 54% improvement over the best case (preload 10.6%) CNR for frame-to-frame strain reconstruction. Actual phantom measurements confirm the essential features of the simulation. Results show that modeling of the nonlinear elastic behavior has the potential to both increase detectability in elasticity imaging and provide a new independent mechanism for tissue differentiation.  相似文献   

5.
An elasticity microscope images tissue stiffness at fine resolution. Possible applications include dermatology, ophthalmology, pathology, and tissue engineering. In addition, if the resolution approaches cellular dimensions, then this system may be very useful in understanding tissue micromorphology. Elasticity images can be reconstructed from displacement and strain fields measured throughout the specimen during controlled external loading. High frequency ultrasound is used to obtain these images by tracking coherent speckle motion during deformation. In this paper, methods are presented to track speckle in two dimensions with near unity correlation coefficients using a high frequency, single element focused transducer. These techniques include improved means for speckle tracking. Procedures to control boundary conditions for consistent specimen deformation and scanning techniques required to obtain a plane-strain state in the imaging plane are also discussed. To test these methods, a 50 MHz elasticity microscope was constructed  相似文献   

6.
In freehand elastography, quasi-static tissue compression is applied through the ultrasound probe, and the corresponding axial strain is estimated by calculating the time shift between consecutive echo signals. This calculation typically suffers from a poor signal-to-noise ratio or from the decorrelation between consecutive echoes resulting from an erroneous axial motion impressed by the operator. This paper shows that the quality of elastograms can be improved through the integration of two distinct techniques in the strain estimation procedure. The first technique evaluates the displacement of the tissue by analyzing the phases of the echo signal spectra acquired during compression. The second technique increases the displacement estimation robustness by averaging multiple displacement estimations in a high-frame-rate imaging system, while maintaining the typical elastogram frame-rate. The experimental results, obtained with the Ultrasound Advanced Open Platform (ULA-OP) and a cyst phantom, demonstrate that each of the proposed methods can independently improve the quality of elastograms, and that further improvements are possible through their combination.  相似文献   

7.
The feasibility of estimating and imaging scatterer size using backscattered ultrasound signals and spectral analysis techniques was demonstrated previously. In many cases, size estimation, although computationally intensive, has proven to be useful for monitoring, diagnosing, and studying disease. However, a difficulty that is encountered in imaging scatterer size is the large estimator variance caused by statistical fluctuations in echo signals from random media. This paper presents an approach for reducing these statistical uncertainties. Multiple scatterer size estimates are generated for each image pixel using data acquired from several different directions. These estimates are subsequently compounded to yield a single estimate that has a reduced variance. In this feasibility study, compounding was achieved by translating a sectored-array transducer in a direction parallel to the acquired image plane. Angular compounding improved the signal-to-noise ratio (SNR) in scatterer size images. The improvement is proportional to the square root of the effective number of statistically independent views available for each image pixel.  相似文献   

8.
Ultrasound elasticity imaging shows promise as a new way for early detection of cancers by assessing the elastic characteristics of soft tissue. So far the commonly used approach involves solving the so-called inverse elasticity problem of recovering elastic parameters from displacement measurements. We propose a finite-elementbased nonlinear scheme to estimate the elasticity distribution of soft tissue from multi-compressed ultrasound radio frequency (RF) data. An experimental ultrasound workstation has been developed to acquire multi-compressed data. A composite probe was employed as the compression plate. The contact forces and torques were acquired at the same time as imaging. Axial displacements under different static loads are estimated from the RF data before and after deformation using a cross-correlation technique. The confidence of displacement estimates is employed as a weighting factor in solving the objective function describing the inverse elasticity reconstruction problem. A novel splitand- merge strategy is employed over the image sequence in which strain images are used to provide a priori knowledge of the relative stiffness distribution of the tissue to constrain the inverse problem solution. The experimental study has allowed us to investigate the performance of our approach in the controlled environment of simulated and phantom data. For a simulated single inclusion model with 5% axial displacement estimation error, the L2-error between the target and the reconstructed Young's modulus was found to be about 1%. In vivo validation of the proposed method has been carried out and some preliminary results are presented.  相似文献   

9.
Tissue elasticity can be estimated from displacement and strain images acquired under controlled deformation. We extend this approach for coronary arteries, deformed and imaged by an integrated angioplasty balloon and ultrasonic imaging probe. Because the lumen cross section of a severely occluded artery is not circular, we have also developed a technique to perform all motion computations in the reference frame of the lumen's geometric center. This coordinate system is independent of the imaging catheter and consequently referencing to this frame removes artifacts associated with probe motion within the balloon during deformation. Displacements and strains estimated by phase-sensitive correlation-based speckle tracking were used to distinguish arterial plaques in simulated coronary arteries of differing elastic moduli: hard, soft, and homogenous. We have also applied these methods to images of a homogeneous gelatin phantom collected with the integrated probe. The maximum phantom displacement was about 40 pm, and the maximum radial normal strain was about 4% (absolute value). The spatial dependence of these quantities shows good agreement with theoretically predicted values  相似文献   

10.
11.
This paper describes a new ultrasound-based system for high-frame-rate measurement of periodic motion in 2-D for tissue elasticity imaging. Similarly to conventional 2-D flow vector imaging, the system acquires the RF signals from the region of interest at multiple steering angles. A custom sector subdivision technique is used to increase the temporal resolution while keeping the total acquisition time within the range suitable for real-time applications. Within each sector, 1-D motion is estimated along the beam direction. The intra- and inter-sector delays are compensated using our recently introduced delay compensation algorithm. In-plane 2-D motion vectors are then reconstructed from these delay-compensated 1-D motions. We show that Young's modulus images can be reconstructed from these 2-D motion vectors using local inversion algorithms. The performance of the system is validated quantitatively using a commercial flow phantom and a commercial elasticity phantom. At the frame rate of 1667 Hz, the estimated flow velocities with the system are in agreement with the velocity measured with a pulsed-wave Doppler imaging mode of a commercial ultrasound machine with manual angle correction. At the frame rate of 1250 Hz, phantom Young's moduli of 29, 6, and 54 kPa for the background, the soft inclusion, and the hard inclusion, are estimated to be 30, 11, and 53 kPa, respectively.  相似文献   

12.
Ultrasonic strain imaging that uses signals from conventional diagnostic ultrasound systems is capable of showing the contrast of tissue elasticity, which provides new diagnostically valuable information. To assess and improve the diagnostic performance of ultrasonic strain imaging, it is essential to have a quantitative measure of image quality. Moreover, it is useful if the image quality measure is simple to interpret and can be used for visual feedback while scanning and as a training tool for operator performance evaluation. This report describes the development of a novel quantitative method for systematic performance assessment that is based on the combination of measures of the accuracy of motion tracking and consistency among consecutive strain fields. The accuracy of motion tracking assesses the reliability of strain images. The consistency among consecutive strain images assesses the signal quality in strain images. The clinical implications of the proposed method to differentiate good or poor strain images are discussed. Results of experiments with tissue-mimicking phantoms and in vivo breast-tissue data demonstrate that the performance measure is a useful method for automatically rating elasticity image quality.  相似文献   

13.
Doppler-based flow analysis methods require acquisition of ultrasound data at high spatio-temporal sampling rates. These rates represent a major technical challenge for ultrasound systems because a compromise between spatial and temporal resolution must be made in conventional approaches. Consequently, ultrasound scanners can either provide full quantitative Doppler information on a limited sample volume (spectral Doppler), or averaged Doppler velocity and/or power estimation on a large region of interest (Doppler flow imaging). In this work, we investigate a different strategy for acquiring Doppler information that can overcome the limitations of the existing Doppler modes by significantly reducing the required acquisition time. This technique is called ultrafast compound Doppler imaging and is based on the following concept: instead of successively insonifying the medium with focused beams, several tilted plane waves are sent into the medium and the backscattered signals are coherently summed to produce high-resolution ultrasound images. We demonstrate that this strategy allows reduction of the acquisition time by a factor of up to of 16 while keeping the same Doppler performance. Depending on the application, different directions to increase performance of Doppler analysis are proposed and the improvement is quantified: the ultrafast compound Doppler method allows faster acquisition frame rates for high-velocity flow imaging, or very high sensitivity for low-flow applications. Full quantitative Doppler flow analysis can be performed on a large region of interest, leading to much more information and improved functionality for the physician. By leveraging the recent emergence of ultrafast parallel beamforming systems, this paper demonstrates that breakthrough performances in flow analysis can be reached using this concept of ultrafast compound Doppler.  相似文献   

14.
The clinical applicability of high-intensity focused ultrasound (HIFU) for noninvasive therapy is currently hampered by the lack of robust and real-time monitoring of tissue damage during treatment. The goal of this study is to show that the estimation of local tissue elasticity from shear wave imaging (SWI) can lead to a precise mapping of the lesion. HIFU treatment and monitoring were respectively performed using a confocal setup consisting of a 2.5-MHz single element transducer focused at 34 mm on ex vivo samples and an 8-MHz ultrasound diagnostic probe. Ultrasound-based strain imaging was combined with shear wave imaging on the same device. The SWI sequences consisted of 2 successive shear waves induced at different lateral positions. Each wave was created with pushing beams of 100 μs at 3 depths. The shear wave propagation was acquired at 17,000 frames/s, from which the elasticity map was recovered. HIFU sonications were interleaved with fast imaging acquisitions, allowing a duty cycle of more than 90%. Thus, elasticity and strain mapping was achieved every 3 s, leading to real-time monitoring of the treatment. When thermal damage occurs, tissue stiffness was found to increase up to 4-fold and strain imaging showed strong shrinkages that blur the temperature information. We show that strain imaging elastograms are not easy to interpret for accurate lesion characterization, but SWI provides a quantitative mapping of the thermal lesion. Moreover, the concept of shear wave thermometry (SWT) developed in the companion paper allows mapping temperature with the same method. Combined SWT and shear wave imaging can map the lesion stiffening and temperature outside the lesion, which could be used to predict the eventual lesion growth by thermal dose calculation. Finally, SWI is shown to be robust to motion and reliable in vivo on sheep muscle.  相似文献   

15.
High frame-rate ultrasound RF data acquisition has been proved to be critical for novel cardiovascular imaging techniques, such as high-precision myocardial elastography, pulse wave imaging (PWI), and electromechanical wave imaging (EWI). To overcome the frame-rate limitations on standard clinical ultrasound systems, we developed an automated method for multi-sector ultrasound imaging through retrospective electrocardiogram (ECG) gating on a clinically used open architecture system. The method achieved both high spatial (64 beam density) and high temporal resolution (frame rate of 481 Hz) at an imaging depth up to 11 cm and a 100% field of view in a single breath-hold duration. Full-view imaging of the left ventricle and the abdominal aorta of healthy human subjects was performed using the proposed technique in vivo. ECG and ultrasound RF signals were simultaneously acquired on a personal computer (PC). Composite, full-view frames both in RF- and B-mode were reconstructed through retrospective combination of seven small (20%) juxtaposed sectors using an ECG-gating technique. The axial displacement of the left ventricle, in both long-axis and short-axis views, and that of the abdominal aorta, in a long-axis view, were estimated using a RF-based speckle tracking technique. The electromechanical wave and the pulse wave propagation were imaged in a cineloop using the proposed imaging technique. Abnormal patterns of such wave propagation can serve as indicators of early cardiovascular disease. This clinical system could thus expand the range of applications in cardiovascular elasticity imaging for quantitative, noninvasive diagnosis of myocardial ischemia or infarction, arrhythmia, abdominal aortic aneurysms, and early-stage atherosclerosis.  相似文献   

16.
In the first paper, the superiority of linear FM signals was shown in terms of signal-to-noise ratio and robustness to tissue attenuation. This second paper in the series of three papers on the application of coded excitation signals in medical ultrasound presents design methods of linear FM signals and mismatched filters, in order to meet the higher demands on resolution in ultrasound imaging. It is shown that for the small time-bandwidth (TB) products available in ultrasound, the rectangular spectrum approximation is not valid, which reduces the effectiveness of weighting. Additionally, the distant range sidelobes are associated with the ripples of the spectrum amplitude and, thus, cannot be removed by weighting. Ripple reduction is achieved through amplitude or phase predistortion of the transmitted signals. Mismatched filters are designed to efficiently use the available bandwidth and at the same time to be insensitive to the transducer's impulse response. With these techniques, temporal sidelobes are kept below 60 to 100 dB, image contrast is improved by reducing the energy within the sidelobe region, and axial resolution is preserved. The method is evaluated first for resolution performance and axial sidelobes through simulations with the program Field II. A coded excitation ultrasound imaging system based on a commercial scanner and a 4 MHz probe driven by coded sequences is presented and used for the clinical evaluation of the coded excitation/compression scheme. The clinical images show a significant improvement in penetration depth and contrast, while they preserve both axial and lateral resolution. At the maximum acquisition depth of 15 cm, there is an improvement of more than 10 dB in the signal-to-noise ratio of the images. The paper also presents acquired images, using complementary Golay codes, that show the deleterious effects of attenuation on binary codes when processed with a matched filter, also confirmed by presented simulated images.  相似文献   

17.
Estimation of displacement location for enhanced strain imaging   总被引:2,自引:0,他引:2  
Ultrasonic strain imaging usually begins with displacement estimates computed using finite-length sections of RF ultrasound signals. Amplitude variations in the ultrasound are known to perturb the location at which the displacement estimate is valid. If this goes uncorrected, it is a significant source of estimation noise, which is amplified when displacement fields are converted into strain images. We present a study of this effect based on theoretical analysis and practical experiments. A correction method based on the analysis is tested on phase zero and correlation coefficient strain imaging, and compared to the amplitude compression techniques of earlier studies. We also test adaptive strain estimation to provide a benchmark, but the performance of our new method matches or surpasses this benchmark under normal scanning conditions. Furthermore, the new correction is suitable for real time applications owing to its extreme computational simplicity.  相似文献   

18.
In ultrasound strain and elasticity imaging, an accurate and cost-effective sub-pixel displacement estimator is required because strain/elasticity imaging quality relies on the displacement SNR, which can often be higher if more computational resources are provided. In this paper, we introduce an autocorrelation-based method to cost-effectively improve subpixel displacement estimation quality. To quantitatively evaluate the performance of the autocorrelation method, simulated and tissue-mimicking phantom experiments were performed. The computational cost of the autocorrelation method is also discussed. The results of our study suggest the autocorrelation method can be used for a real-time elasticity imaging system.  相似文献   

19.
In recent years, novel quantitative techniques have been developed to provide noninvasive and quantitative stiffness images based on shear wave propagation. Using radiation force and ultrafast ultrasound imaging, the supersonic shear imaging technique allows one to remotely generate and follow a transient plane shear wave propagating in vivo in real time. The tissue shear modulus, i.e., its stiffness, can then be estimated from the shear wave local velocity. However, because the local shear wave velocity is estimated using a time-of- flight approach, reflected shear waves can cause artifacts in the estimated shear velocity because the incident and reflected waves propagate in opposite directions. Such effects have been reported in the literature as a potential drawback of elastography techniques based on shear wave speed, particularly in the case of high stiffness contrasts, such as in atherosclerotic plaque or stiff lesions. In this letter, we present our implementation of a simple directional filter, previously used for magnetic resonance elastography, which separates the forward- and backward-propagating waves to solve this problem. Such a directional filter could be applied to many elastography techniques based on the local estimation of shear wave speed propagation, such as acoustic radiation force imaging (ARFI), shearwave dispersion ultrasound vibrometry (SDUV), needle-based elastography, harmonic motion imaging, or crawling waves when the local propagation direction is known and high-resolution spatial and temporal data are acquired.  相似文献   

20.
高频超声成像以其高分辨和实时性好等优势成为近年来医学超声成像领域研究的热点。但由于超声的衰减随频率增加呈指数级升高,导致高频超声信号幅值小,图像信噪比低。为了增强高频超声成像的信噪比,近年来编码发射(又称编码激励)技术得到了越来越多的研究和应用。文章对近几年国内外编码发射技术在医学高频超声成像方面的应用和研究进展进行了综述,重点分析了Chirp码、巴克(Barker)码和格雷(Golay)码3种主要编码发射技术在高频超声成像方面应用的优缺点,并综合对比了各种编码发射技术在高频成像方面的应用前景。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号