首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The response of the Defence Science and Technology Laboratory (DSTL) PADC personal neutron dosemeter is strongly dependent upon neutron energy, with a range of 300-500 tracks per cm2 per mSv for energies between 1 and 5 MeV. Below 1 MeV the response drops off sharply. This lack of sensitivity is undesirable when the dosemeter is employed with the softened fission spectra encountered in the workplace. In order to incorporate a thermal response, a polypropylene converter doped with LiF has been placed directly in front of the PADC elements. Tritons produced in the thermal neutron reaction 6Li (n,t)alpha at 2.7 MeV will then penetrate the PADC, leaving a trail of damage. The reaction rate within the converter has been calculated using MCNP for thermal neutrons and a range of higher energies, while transport of the tritons is modelled using the SRIM/TRIM package to determine the resultant track density and depth distribution. The modelling and experimental work have demonstrated that a concentration of 0.2% natural lithium by weight results in a track density in a thermal field comparable with that produced per unit personal dose equivalent by neutrons greater than 1 MeV in the standard dosemeter. Additional MCNP modelling has demonstrated that the dosemeters' albedo response to intermediate energy neutrons can be enhanced considerably by placing a boron-doped shield in front of the converter and increasing its lithium concentration.  相似文献   

2.
3.
The neutron response was characterised for Al(2)O(3):C material coated with (6)Li(2)CO(3). Al(2)O(3):C material, an optically stimulated luminescent (OSL) dosemeter, which is sensitive to both photons and beta radiation but is mostly insensitive to neutron radiation. The Al(2)O(3):C material was coated with (6)Li(2)CO(3) to create a material sensitive to neutrons, beta and photon radiation. In this paper, the neutron response of this new OSL material (OSLN) will be compared with various other neutron measurement technologies in laboratory and field environments.  相似文献   

4.
The performance of a personal neutron dosemeter with a single silicon diode using a linear combination of its pulse height information was studied. Its dosimetric behaviour in fields with neutrons of different energy and directional distribution is shown for neutron energies ranging from thermal to 100 MeV and for directions of incidence ranging from frontal to lateral. The dosemeter is photon-insensitive and its dose detection threshold is at about 20 microSv. The dosimetric characteristics are compared with those of commercial dosemeters based on silicon detectors.  相似文献   

5.
Within the EC project EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'), different types of active neutron personal dosemeters (and some passive ones) were tested in workplace fields at nuclear installations in Europe. The results of the measurements which have been performed up to now are summarised and compared to our currently best estimates of the personal dose equivalent Hp(10). Under- and over-readings by more than a factor of two for the same dosemeter in different workplace fields indicate that in most cases the use of field-specific correction factors is required.  相似文献   

6.
The bubble detector is demonstrated as one of the best suitable neutron detectors for neutron dose rate measurements in the presence of high-intense gamma fields. Immobilisation of a volatile liquid in a superheated state and achieving uniform distribution of tiny superheated droplets were a practical challenge. A compact and reusable bubble detector with high neutron sensitivity has been developed at the Indira Gandhi Centre for Atomic Research by immobilising the superheated droplets in a suitable polymer matrix. Two types of bubble detectors have been successfully developed, one by incorporating isobutane for measuring fast neutron and another by incorporating Freon-12 for both fast and thermal neutron. The performance of the detector has been tested using 5 Ci Am-Be neutron source and the results are described.  相似文献   

7.
In this paper the present status of the Direct Ion Storage Neutron (DIS-N) prototype dosemeter (RADOS) is described. The separation of neutron from photon dose equivalent has been improved by adding tin shieldings. The neutron energy response has been changed by additional plastic covers containing 40% B4C in order to reduce the over-response to thermal neutrons. The responses of the dosemeters were determined for standard photon and neutron fields (monoenergetic neutrons, neutron sources and simulated workplace fields). Irradiations in real workplaces were also performed. The dependence of the neutron response on the angle of incidence was measured for different neutron sources.  相似文献   

8.
In order to develop an active-type personal dosemeter having suitable sensitivity to high-energy neutrons, the characteristic response of silicon surface barrier detector has been investigated experimentally and theoretically. An agreement of the shape of pulse-height distribution, its change with radiator thickness and the relative sensitivity was confirmed between the calculated and experimental results for 14.8-MeV neutrons. The angular dependence was estimated for other neutron energies, and found that the angular dependence decreased with the incident energy. The reason was also discussed with regard to the radiator thickness relative to maximum range of recoil protons.  相似文献   

9.
Over the last few years IPSN has been developing a small, tissue equivalent proportional counter (TEPC) with multielement geometry for personal radiation protection monitoring. This paper presents the last prototype, which is insensitive to microphony, and the experimental results. Numerical modelling results using CERN codes are partly presented and allow an understanding of the nuclear and electrostatic physics involved in a TEPC.  相似文献   

10.
Variations in the energy dependence of response of neutron personal dosemeters cause systematic errors in the readings obtained in workplace fields. The magnitude of these errors has been determined theoretically by folding measured and calculated workplace energy distributions with dosemeter response functions, to determine the response of a given personal dosemeter in that field. These results have been analysed with consideration of the dosemeter response to various calibration spectra, and with reference to different workplaces. The dosemeters in the study are discussed in terms of the workplaces for which they can be suitably calibrated. Deficiencies in the published neutron energy distributions are identified.  相似文献   

11.
This paper mainly aims at presenting the measurements and the results obtained with the electronic personal neutron dosemeter Saphydose-N at different facilities. Three campaigns were led in the frame of the European contract EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields'). The first one consisted in the measurements at the IRSN French research laboratory in reference neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources ((241)AmBe; (252)Cf; (252)Cf(D(2)O)\Cd) and a realistic spectrum (CANEL/T400). The second one was performed at the Krümmel Nuclear Power Plant (Germany) close to the boiling water reactor and to a spent fuel transport cask. The third one was realised at Mol (Belgium), at the VENUS Research Reactor and at Belgonucléaire, a fuel processing factory.  相似文献   

12.
Ionisation chambers are sensitive to both neutrons and photons. In order to produce a neutron dosemeter based on an ion chamber a double-chamber system which allows for differential readings has to be built. The system consists of one chamber with high neutron sensitivity (e.g. A-150 or polyethylene with 10B or 6Li compounds) and one chamber with low neutron sensitivity (e.g. graphite or Teflon). Different combined dosemeter prototypes were produced and their responses for standard photon and neutron radiation fields, as well as various field spectra, were determined. The feasibility of neutron dosimetry with ion chambers and direct ion storage (DIS) electronics has been proved. The results obtained with prototype dosemeters indicate the system's promising potential for legal approval in the future. Apart from dosimetric properties, the advantages of the system are its small size and weight, easy readout and relatively low production cost.  相似文献   

13.
A CMOS active pixel sensor, originally designed for the tracking of minimum ionising charged particles in high-energy physics, has been recently used for the detection of fast neutrons. Data were taken at the IRSN Cadarache facility with a (241)Am-Be ISO source and a polyethylene radiator. A high-intrinsic efficiency (1.2 x 10(-3)) has been obtained. It is in good agreement with both calculations and a MCNPX Monte Carlo simulation. This experiment paves the way for a fully electronic personal neutron dosemeter.  相似文献   

14.
Lithium-gadolinium-borate (LGB) dispersed as microcrystals within the plastic scintillator BC-490 is a promising material for accurate neutron dosimetry in mixed n/gamma fields. Spectral information > 1 MeV is obtained by capture gating proton recoil events in the plastic scintillator to subsequent capture in (6)Li. Below 1 MeV, isolated capture events in either gadolinium or (6)Li give energy information in this region. Discrimination based on capture gating is used to reject false coincidences due to gamma rays or incorrectly gated neutron events. A detailed Monte Carlo model has been created in MCNPX that predicts the energy response of the LGB spectrometer in the capture-gated mode of operation. X-ray microtomography has been performed on the detector in order to obtain the LGB microcrystal distribution within the plastic scintillator, and this is incorporated into the model. The way in which the calculated response functions can be included in an unfolding procedure is outlined.  相似文献   

15.
This paper presents the results of measurements made with the electronic personal neutron Saphydose-N during the four campaigns of the European contract EVIDOS (EValuation of Individual DOSimetry in mixed neutron and photon radiation fields). These measurements were performed at Institute for Radiological Protection and Nuclear Safety (IRSN) in France (C0), at the Krümmel Nuclear Power Plant in Germany (C1), at the VENUS Research Reactor and the Belgonucléaire fuel processing plant in Belgium (C2) and at the Ringhals Nuclear Power Plant in Sweden (C3). The results for Saphydose-N are compared with reference values for dose equivalent.  相似文献   

16.
In the framework of the EVIDOS project, funded by the EC, measurements were carried out using dosemeters, based on ionisation chambers with direct ion storage (DIS-N), at several workplace fields, namely, at a fuel processing plant, a boiling and a pressurised water reactor, and near transport and storage casks. The measurements and results obtained with the DIS-N in these workplaces, which are representative for the nuclear industry, are described in this study. Different dosemeter configurations of converter and shielding materials were considered. The results are compared with values for personal dose equivalent which were assessed within the EVIDOS project by other partners. The advantages and limitations of the DIS-N dosemeter are discussed.  相似文献   

17.
An advanced-type small, light, multi-functional electronic personal dosemeter has been developed using silicon semiconductor radiation detectors for dose management of workers at nuclear power plants and accelerator facilities. This dosemeter is 62 x 82 x 27 mm(3) in size and approximately 130 g in weight, which is capable of measuring personal gamma ray and neutron dose equivalents, Hp(10), simultaneously. The neutron dose equivalent can be obtained using two types of silicon semiconductors: a slow-neutron sensor (<1 MeV) and a fast-neutron sensor (>1 MeV). The slow neutron sensor is a 10 x 10 mm(2) p-type silicon on which a natural boron layer is deposited around an aluminium electrode. The fast neutron sensor is also a 10 x 10 mm(2) p-type silicon crystal on which an amorphous silicon hydride is deposited. The neutron energy response corresponding to the fluence-to-dose-equivalent conversion coefficient given by ICRP Publication 74 has been evaluated using a monoenergetic neutron source from 250 keV to 15 MeV at the Fast Neutron Laboratory of Tohoku University. As the result, the Hp(10) response to neutrons in the energy range of 250 keV and 4.4 MeV within +/-50% difference has been obtained.  相似文献   

18.
A neutron dosemeter which offers instant read-out has been developed for nuclear criticality accidents. The system is based on gels containing emulsions of superheated dichlorodifluoromethane droplets, which vaporise into bubbles upon neutron irradiation. The expansion of these bubbles displaces an equivalent volume of gel into a graduated pipette, providing an immediate measure of the dose. Instant read-out is achieved using an array of transmissive optical sensors which consist of coupled LED emitters and phototransistor receivers. When the gel displaced in the pipette crosses the sensing region of the photomicrosensors, it generates a signal collected on a computer through a dedicated acquisition board. The performance of the device was tested during the 2002 International Accident Dosimetry Intercomparison in Valduc, France. The dosemeter was able to follow the initial dose gradient of a simulated accident, providing accurate values of neutron kerma; however, the emulsion was rapidly depleted of all its drops. A model of the depletion effects was developed and it indicates that an adequate dynamic range of the dose response can be achieved by using emulsions of smaller droplets.  相似文献   

19.
The monitoring of radon exposure at workplaces is of great importance. Up to now passive measurement systems have been used for the registration of radon gas. Recently an electronic radon gas personal dosemeter came onto the market as an active measurement system for the registration of radon exposure (DOSEman; Sarad GmbH, Dresden, Germany). In this personal monitor, the radon gas diffuses through a membrane into a measurement chamber. A silicon detector system records spectroscopically the alpha decays of the radon gas and of the short-lived progeny 218Po and 214Po gathered onto the detector by an electrical field. In this work the calibration was tested and a proficiency test of this equipment was made. The diffusion behaviour of the radon gas into the measurement chamber, susceptibility to thoron, efficiency, influence of humidity, accuracy and the detection limit were checked.  相似文献   

20.
Since 1993, the Institute for Radiological Protection and Nuclear Safety (IRSN) has lead, in association with Electricité de France (EDF), a R&D study of a neutron personal electronic dosemeter. This dosemeter, called 'Saphydose-N', is manufactured by the SAPHYMO company. This paper presents first the optimisation of some detector components using Monte Carlo calculations, and second the test of the manufactured Saphydose-N under radiation following the IEC 1323 standard's recommendations for active personal neutron dosemeters. The measurements with the manufactured dosemeter were performed on the one hand at PTB (Physikalisch-Technische Bundesanstalt) in mono-energetic neutron fields and, on the other hand at IRSN in neutron fields generated by a thermal facility (SIGMA), radionuclide ISO sources and a realistic spectrum (CANEL/T400). The manufactured dosemeter Saphydose-N was also tested during measurement campaigns of the European programme EVIDOS ('Evaluation of Individual Dosimetry in Mixed Neutron and Photon Radiation Fields') at different nuclear workplaces. The study showed that Saphydose-N complies with the recommendations of standard IEC 1323 and can be used at any workplace with no previous knowledge of the neutron field characteristics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号