首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A novel microfluidic device has been developed for on-chip transport, location, and quantal release monitoring of single cells. The microfluidic device consists of a plate of PDMS containing channels for introducing cells and stimulants and a glass substrate into which a cell micro-chamber was etched. The two tightly reversibly sealed plates can be separated for respective cleaning, which significantly extends the lifetime of the microchip that is frequently clogged in cell analysis experiments. Using hydraulic pressure, single cells were transported and located on the microfluidic chip. After location of a single PC12 cell on the microfluidic chip, the cell was stimulated by nicotine that was also introduced through the micro-channels, and the quantum release of dopamine from the cell was amperometricly detected with our designed carbon fiber microelectrode. The results have demonstrated the convenience and efficiency of using the microfluidic chip for monitoring of quantal release from single cells and have offered a facile method for the analysis of single cells on microfluidic devices.  相似文献   

2.
Jeong GS  Han S  Shin Y  Kwon GH  Kamm RD  Lee SH  Chung S 《Analytical chemistry》2011,83(22):8454-8459
Microfluidic cell culture assays are versatile tools for studying cell migration, particularly angiogenesis. Such assays can deliver precisely controlled linear gradients of chemical stimuli to cultured cells in a microfluidic channel, offering excellent optical resolution and in situ monitoring of cellular morphogenesis in response to a gradient. Microfluidic cell culture assays provide a chemical gradient subject to molecular diffusion, although cellular metabolism can perturb it. The actual gradient perturbed by cells has not been precisely described in the context of regulated cellular morphogenesis. We modeled the chemical gradient in a microfluidic channel by simulating the analyte(VEGF) distribution during cellular interactions. The results were experimentally verified by monitoring sprouting angiogenic response from a monolayer of human umbilical vein endothelial cells (hUVECs) into a type 1 collagen scaffold. The simulation provided a basis for understanding a real distribution of the analyte interrupted by cells in microfluidic device. The new protocol enables one to quantify the morphogenesis of hUVECs under a flat, less-steep, or steep gradient.  相似文献   

3.
4.
Bui MP  Li CA  Han KN  Choo J  Lee EK  Seong GH 《Analytical chemistry》2011,83(5):1603-1608
In this paper, we propose a microfluidic device that is capable of generating a concentration gradient followed by parallel droplet formation within channels with a simple T-junction geometry. Linear concentration gradient profiles can be obtained based on fluid diffusion under laminar flow. Optimized conditions for generating a linear concentration gradient and parallel droplet formation were investigated using fluorescent dye. The concentration gradient profile under diffusive mixing was dominated by the flow rate at sample inlets, while parallel droplet formation was affected by the channel geometry at both the inlet and outlet. The microfluidic device was experimentally characterized using optimal layout and operating conditions selected through a design process. Furthermore, in situ enzyme kinetic measurements of the β-galactosidase-catalyzed hydrolysis of resorufin-β-d-galactopyranoside were performed to demonstrate the application potential of our simple, time-effective, and low sample volume microfluidic device. We expect that, in addition to enzyme kinetics, drug screening and clinical diagnostic tests can be rapidly and accurately performed using this droplet-based microfluidic system.  相似文献   

5.
A microfluidic chip that allows for the continuous monitoring of cellular secretions from multiple independent living samples was developed. Performance of the device was characterized through the analysis of insulin secretion from islets of Langerhans. The chip contained four individual channel networks, each capable of performing electrophoresis-based immunoassays of the perfusate from islets. In the networks, islets were housed in a chamber that was continuously perfused with pressure-driven biological media at 0.6 microL min-1. Electroosmosis was used to pull perfusate containing secreted insulin into 4-cm-long reaction channels where it mixed with fluorescein isothiocyanate-labeled insulin and anti-insulin antibody for 60 s. The reaction streams were sampled at 6.25-s intervals and analyzed in parallel using an on-chip capillary electrophoresis separation with laser-induced fluorescence detection by a scanning confocal microscope. The limit of detection for insulin was 10 nM. The device was used to complete over 1450 immunoassays of biological samples in less than 40 min, allowing the parallel monitoring of insulin release from four islets every 6.25 s.  相似文献   

6.
We have developed a novel approach for interfacing ionically conductive membranes with microfluidic systems using phase-changing sacrificial layers. Imprinted microchannels in a polymer substrate are filled with a heated liquid that solidifies at room temperature, a monomer solution is placed over the protected channels and polymerized to form a rigid semipermeable copolymer, and then the protective layer is melted and removed, leaving an open microchannel interfaced with a polymer membrane. We have applied this method in miniaturizing electric field gradient focusing (EFGF) and carrying out on-chip protein preconcentration. A semipermeable copolymer in the EFGF microchips fills a region of changing cross-sectional area, which allows a gradient in electric field to be established when an electrical potential is applied. Our technique provides microchip EFGF devices that offer 3-fold improved resolution in protein focusing compared with capillary-based systems. In addition, these EFGF microchips can separate peptide samples with resolution similar to what is obtained in capillary electrophoresis microdevices, and the micro-EFGF systems enrich analytes by a factor of >150. Finally, we have fabricated membrane-integrated microfluidic devices that can concentrate protein samples (R-phycoerythrin) over 10 000-fold to facilitate microchip capillary electrophoresis. Interfacing microchannels with ion-permeable membranes has great potential to enhance microchip analysis of biomolecules.  相似文献   

7.
Li X  Li PC 《Analytical chemistry》2005,77(14):4315-4322
A microfluidic method to study the contraction of a single cardiac myocyte (heart muscle cell) has been developed. This method integrates various single-cell operations as well as on-chip dye loading, and quantitative analysis of intracellular calcium concentration, [Ca2+]i. After the channel enlargement by on-chip etching to accommodate large-sized cardiac myocytes, a single cell is selected and retained at a V-shaped cell retention structure within the microchip. Owing to the fragile property of the cardiac myocytes that could easily be damaged by centrifugation, the calcium-sensitive fluorescent dye was loaded in the cell by on-chip dye loading. This on-chip method minimized the damage to the cells from the use of a centrifuge in the conventional method and provided a way of cellular analysis of fragile cells. Subsequently, quantitative analysis of [Ca2+]i of a single cardiac myocyte by fluorescence measurement was achieved for the first time in a microfluidic chip, thanks to the intracellular calcium stimulant of ionomycin. The resting [Ca2+]i of the cardiomyocyte determined was consistent with the literature value. From the spontaneous contraction study, it was found that fluorescence intensity cannot represent the [Ca2+]i variation accurately, which implied the importance of the quantitative analysis of [Ca2+]i.  相似文献   

8.
Presented is a novel approach for an integrated micro total analysis system (microTAS) based on a microfluidic on-chip device that supports ultrasensitive confocal detection of fluorescent cells and particles and subsequently allows for their precise sorting in the fluid phase with respect to spectroscopic properties, such as brightness and color. The hybrid silicone elastomer/glass chip first comprises a branched channel system to initiate fluid mixing and to hydrodynamically focus the sample solution down to a thin flow layer, matching the size of the confocal detection volume placed at that position and, thus, providing a high detection efficiency. In the subsequent on-chip module, the dispersed cells or particles can be sorted into two different output channels. The sorting process is realized by a perpendicular deflection stream that can be switched electrokinetically. The performance of the automated sorting routine is demonstrated by precise partition of a mixture of differently colored fluorescent beads. Moreover, the specifically branched channel geometry allows for direct implementation of reaction steps prior to detection and sorting, which is demonstrated by inducing a selective recognition reaction between the fluorescent protein R-phycoerythrin and a mixture of live bacterial cells exhibiting or lacking the respective surface antigens.  相似文献   

9.
We developed a microfluidic chip that provides rapid temperature changes and accurate temperature control of the perfusing solution to facilitate patch-clamp studies. The device consists of a fluid channel connected to an accessible reservoir for cell culture and patch-clamp measurements. A thin-film platinum heater was placed in the flow channel to generate rapid temperature change, and the temperature was monitored using a thin-film resistor. We constructed the thermal chip using SU-8 on a glass wafer to minimize the heat loss. The chip is capable of increasing the solution temperature from bath temperature (20 degrees C) to 80 degrees C at an optimum heating rate of 0.5 degrees C/ms. To demonstrate the ability of the thermal chip, we have conducted on-chip patch-clamp recordings of temperature-sensitive ion channels (TRPV1) transfected HEK293 cells. The heat-stimulated currents were observed using whole-cell and cell-attached patch configurations. The results demonstrated that the chip can provide rapid temperature jumps at the resolution of single-ion channels.  相似文献   

10.
A new form of microchip isoelectric focusing that allows efficient coupling with pretreatment processes is reported. The sample is conveyed in a carrier ampholyte solution to the separation channel that is connected at both ends by two V-shaped lead channels, which supply electrode solutions to the connection point and complete the electrical connection to off-chip electrodes. The relatively high electric conductivity of the electrode solutions compared with that of the pH gradient enables focusing with a 2% loss of applied voltage at the electrodes using the lead channels. A glass microchip was constructed specifically for this configuration. The channel wall was coated with polydimethylacrylamide, and the IEF chip was operated in a chip holder equipped with on-chip connector valves. A plug of fluorescence-labeled peptide p I markers with p I values ranging from 3.64 to 9.56 with carrier ampholyte solution (pH 3-10) was introduced into the separation channel. When the plug reached the channel segment (24 mm in length) between the connection points with the electrolyte lead channels, isoelectric focusing was started after filling the lead channels with electrolyte solutions. The peptide markers were observed using scanning fluorescence detection. The entire range of the pH gradient was established in the segment after approximately 2 min. Isoelectric focusing of three consecutively injected sample plugs containing different p I markers was demonstrated.  相似文献   

11.
Mao H  Holden MA  You M  Cremer PS 《Analytical chemistry》2002,74(19):5071-5075
This paper describes a reusable platform that can apply a linear temperature gradient to a lab-on-a-chip device. When a planar microfluidic device with a series of microchannels is placed on top of the platform with the channels perpendicular to the gradient, each channel is held at a discrete temperature. This allows temperature-dependent data for chemical or biochemical species flowed into the device to be obtained in a concurrent fashion. As a demonstration, a melting curve for dsDNA is performed by collecting all the data simultaneously. The gradient is stable enough to easily distinguish between 30-mers where the complement strand contains a single C-A mismatch or a single T-G mismatch or is a perfect match. On the other hand, a temperature gradient can be formed parallel to the direction of flow of the microchannels. This allows the temperature in each channel to vary continuously as the liquid flows downstream. If each microchannel in the array contains a distinct pH value, ionic strength, species concentration, or chemical composition, then a high-throughput two-variable experiment can be performed. We demonstrate this mode of data collection by measuring the fluorescence yield of fluorescein dye molecules in aqueous solution simultaneously as a function of concentration and temperature.  相似文献   

12.
Microfluidic devices made from poly(dimethylsiloxane) (PDMS) are gas permeable and have been used to provide accurate on-chip oxygen regulation. However, pervaporation in PDMS devices can rapidly lead to dramatic changes in solution osmotic pressure. In the present study, we demonstrate a new method for on-chip oxygen control using pre-equilibrated aqueous solutions in gas-control channels to regulate the oxygen content in stagnant microfluidic test chambers. An off-chip gas exchanger is used to equilibrate each control solution prior to entering the chip. Using this strategy, problems due to pervaporation are considerably reduced. An integrated PDMS-based oxygen sensor allows accurate real-time measurements of the oxygen within the microfluidic chamber. The measurements were found to be consistent with predictions from finite-element modeling.  相似文献   

13.
A miniaturized system for DNA mutation analysis, utilizing temperature gradient gel electrophoresis (TGGE) in a polycarbonate (PC) microfluidic device, is reported. TGGE reveals the presence of sequence heterogeneity in a given heteroduplex sample by introducing a thermal denaturing gradient that results in differences between the average electrophoretic mobilities of DNA sequence variants. Bulk heater assemblies are designed and employed to externally generate temperature gradients in spatial and temporal formats along the separation channels. TGGE analyses of model mutant DNA fragments, each containing a single base substitution, are achieved using both single- and 10-channel parallel measurements in a microfluidic platform. Additionally, a comprehensive polymer microfluidic device containing an integrated microheater and sensor array is developed and demonstrated for performing spatial TGGE for DNA mutation analysis. The device consists of two PC modular substrates mechanically bonded together. One substrate is embossed with microchannels, and the other contains a tapered microheater, lithographically patterned along with an array of temperature sensors. Compared with the external heating approaches, the integrated platform provides significant reduction in power requirement and thermal response time while establishing more accurate and highly effective control of the temperature gradient for achieving improved separation resolution.  相似文献   

14.
Laser-induced mixing in microfluidic channels   总被引:2,自引:0,他引:2  
We demonstrate a novel strategy for mixing solutions and initiating chemical reactions in microfluidic systems. This method utilizes highly focused nanosecond laser pulses from a Q-switched Nd:YAG laser at lambda = 532 nm to generate cavitation bubbles within 100- and 200-microm-wide microfluidic channels containing the parallel laminar flow of two fluids. The bubble expansion and subsequent collapse within the channel disrupts the laminar flow of the parallel fluid streams and produces a localized region of mixed fluid. We use time-resolved imaging and fluorescence detection methods to visualize the mixing process and to estimate both the volume of mixed fluid and the time scale for the re-establishment of laminar flow. The results show that mixing is initiated by liquid jets that form upon cavitation bubble collapse and occurs approximately 20 micros following the delivery of the laser pulse. The images also reveal that mixing occurs on the millisecond time scale and that laminar flow is re-established on a 50-ms time scale. This process results in a locally mixed fluid volume in the range of 0.5-1.5 nL that is convected downstream with the main flow in the microchannel. We demonstrate the use of this mixing technique by initiating the horseradish peroxidase-catalyzed reaction between hydrogen peroxide and nonfluorescent N-acetyl-3,7-dihydroxyphenoxazine (Amplex Red) to yield fluorescent resorufin. This approach to generate the mixing of adjacent fluids may prove advantageous in many microfluidic applications as it requires neither tailored channel geometries nor the fabrication of specialized on-chip instrumentation.  相似文献   

15.
The T-sensor is a recently developed microfluidic chemical measurement device that exploits the low Reynolds number flow conditions in microfabricated channels. The interdiffusion and resulting chemical interaction of components from two or more input fluid streams can be monitored optically, allowing measurement of analyte concentrations on a continuous basis. In a simple form of T-sensor, the concentration of a target analyte is determined by measuring fluorescence intensity in a region where the analyte and a fluorescent indicator have interdiffused. An analytical model has been developed that predicts device behavior from the diffusion coefficients of the analyte, indicator, and analyte--indicator complex and from the kinetics of the complex formation. Diffusion coefficients depend on the local viscosity which, in turn, depends on local concentrations of all analytes. These relationships, as well as reaction equilibria, are often unknown. A rapid method for determining these unknown parameters by interpreting T-sensor experiments through the model is presented.  相似文献   

16.
We describe a microfluidic device for generating nonlinear (exponential and sigmoidal) concentration gradients, coupled with a microwell array for cell storage and analysis. The device has two inputs for coflowing multiple aqueous solutions, a main coflow channel and an asymmetrical grid of fluidic channels that allows the two solutions to combine at intersection points without fully mixing. Due to this asymmetry and diffusion of the two species in the coflow channel, varying amounts of the two solutions enter each fluidic path. This induces exponential and sigmoidal concentration gradients at low and high flow rates, respectively, making the microfluidic device versatile. A key feature of this design is that it is space-saving, as it does not require multiplexing or a separate array of mixing channels. Furthermore, the gradient structure can be utilized in concert with cell experiments, to expose cells captured in microwells to various concentrations of soluble factors. We demonstrate the utility of this design to assess the viability of fibroblast cells in response to a range of hydrogen peroxide (H(2)O(2)) concentrations.  相似文献   

17.
Integrating multiple analytical processes into microfluidic devices is an important research area required for a variety of microchip-based analyses. A microfluidic system is described that achieves preparative separations by intelligent fraction collection of attomole quantities of sample. The device consists of a main microfluidic channel used to perform electrophoresis, which is interconnected at 90 degrees to two vertically displaced channels via a nanocapillary array membrane. The membrane interconnect contains nanometer-diameter pores that provide fluidic communication between the channels. Sample injection and analyte collection are controlled by application of an electrical bias between the microfluidic channels across the nanocapillary array. After the separation, the automated transfer of the FITC-labeled Arg, Gln, and Gly bands occurs; a fluorescence detector located at the separation/collection channel interconnect is used to generate a triggering signal that initiates suitable voltages to allow near-quantitative transfer of analyte from the separation channel to the second fluidic layer. The ability to achieve such sample manipulations from mass-limited samples enables a variety of postseparation processing events.  相似文献   

18.
Microfabricated system for parallel single-cell capillary electrophoresis   总被引:4,自引:0,他引:4  
Munce NR  Li J  Herman PR  Lilge L 《Analytical chemistry》2004,76(17):4983-4989
Performing single-cell electrophoresis separations using multiple parallel microchannels offers the possibility of both increasing throughput and eliminating cross-contamination between different separations. The instrumentation for such a system requires spatial and temporal control of both single-cell selection and lysis. To address these problems, a compact platform is presented for single-cell capillary electrophoresis in parallel microchannels that combines optical tweezers for cell selection and electromechanical lysis. Calcein-labeled acute myloid leukemia (AML) cells were selected from an on-chip reservoir and transported by optical tweezers to one of four parallel microfluidic channels. Each channel entrance was manufactured by F2-laser ablation to form a 20- to 10-microm tapered lysis reservoir, creating an injector geometry effective in confining the cellular contents during mechanical shearing of the cell at the 10-microm capillary entrance. The contents of individual cells were simultaneously injected into parallel channels resulting in electrophoretic separation as recorded by laser-induced fluorescence of the labeled cellular contents.  相似文献   

19.
A novel concept for assembling various chemical functions onto a single microfluidic device is proposed. The concept, called a capillary-assembled microchip, involves embedding chemically functionalized capillaries into a lattice microchannel network fabricated on poly(dimethylsiloxane) (PDMS). The network has the same channel dimensions as the outer dimensions of the capillaries. In this paper, we focus on square capillaries to be embedded into a PDMS microchannel network having a square cross section. The combination of hard glass square capillary and soft square PDMS channel allows successful fabrication of a microfluidic device without any solution leakage, and which can use diffusion-based two-solution mixing. Two different types of chemically modified capillaries, an ion-sensing capillary and a pH-sensing capillary, are prepared by coating a hydrophobic plasticized poly(vinyl chloride) membrane and a hydrophilic poly(ethyleneglycol) membrane containing functional molecules onto the inner surface of capillaries. Then, they are cut into appropriate lengths and arranged on a single microchip to prepare a dual-analyte sensing system. The concept proposed here offers advantages inherent to using a planar microfluidic device and of chemical functionality of immobilized molecules. Therefore, we expect to fabricate various types of chemically functionalized microfluidic devices soon.  相似文献   

20.
Microfluidic chip devices are shown to be attractive platforms for performing microscale voltammetric analysis and for integrating voltammetric procedures with on-chip chemical reactions and fluid manipulations. Linear-sweep, square-wave, and adsorptive-stripping voltammograms are recorded while electrokinetically "pumping" the sample through the microchannels. The adaptation of voltammetric techniques to microfluidic chip operation requires an assessment of the effect of relevant experimental variables, particularly the high voltage used for driving the electroosmotic flow, upon the background current, potential window, and size or potential of the voltammetric signal. The exact potential window of the chip detector is dependent upon the driving voltage. Manipulation of the electroosmotic flow opens the door to hydrodynamic modulation (stopped-flow) and reversed-flow operations. The modulated analyte velocity permits compensation of the microchip voltammetric background. Reversal of the driving voltage polarity offers extended residence times in the detector compartment. Rapid square-wave voltammetry/flow injection operation allows a detection limit of 2 x 10(-12) mol (i.e., 2 pmol) of 2,4,6-trinitrotoluene (TNT) in connection with 47 nL of injected sample. The ability of integrating chemical reactions with voltammetric detection is demonstrated for adsorptive stripping measurements of trace nickel using the nickel-dimethylglyoxime model system. The voltammetric response is characterized using catechol, hydrazine, TNT, and nickel as test species. The ability to perform on-chip voltammertic protocols in advantageous over nanovial voltammetric operations that lack a liquid-handling capability. Coupling the versatility of microfluidic chips with the rich information content of voltammetry thus opens an array of future opportunities.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号