首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Ten screw-shaped commercially pure titanium implants were inserted in 10 rabbit tibia. The implants with surrounding bone were harvested after 12 weeks. The samples were processed to be cut and ground. Histomorphometrical analyses of the bone-to-metal contact and the bone area around the entire implants were performed on transvertically cut sections at intervals, starting with 100 microns thick sections; then the same sections were further ground down to 50, 30 and 10 microns. The thicker the section the more bone-to-metal contacts were demonstrated. A statistically significant difference was obtained when comparing the 100-30, 100-10, 50-30 and the 50-10 microns thick sections. Comparing the area measurements of 100-10, 50-30, 50-10 and 30-10 microns revealed a statistically significant difference. Bone-to-metal contact measurements on ground sections that are too thick (over 30 microns) may result in overestimations of the 'true' bony contacts.  相似文献   

2.
The aim of the present investigation was to compare the effect of using autologous bone particles covered with a bioresorbable matrix barrier with the use of bone particles alone on bone augmentation at titanium implants installed in the rabbit tibia. Two Br?nemark System implants, one in each tibia, were inserted in each of 9 rabbits in such a way that 5 threads were not covered with bone. Autologous bone particles were harvested from the skull and placed over the exposed implant surfaces on each tibia. The bone graft on one tibia was covered with a Guidor Matrix Barrier, while the bone graft on the other tibia served as a control. After a healing period of 12 weeks, the animals were sacrificed and specimens taken for histomorphometrical analyses. The analyses showed that a significantly larger volume of augmented bone tissue had formed at the test sites. There were, however, no differences in the amount of mineralized bone. In fact, the difference in tissue volume was due to an increased amount of bone marrow at the test sites. The degree of mineralized bone to implant contact as well as the degree of mineralized bone within the threads at the test implants were similar to that at the controls. In conclusion, it was found that the coverage of particulate autologous bone grafts with a bioresorbable barrier resulted in a larger volume of augmented bone than the use of bone grafts not covered with a barrier.  相似文献   

3.
Several recent studies have investigated the effects of growth hormone (GH) on the healing of fractures and bone ingrowth, but with conflicting results. The negative results may be due to antibody formation against injected GH or because some experimental models are able to prove only positive GH effects. In this study, we wanted to investigate the effect of GH on implant integration in bone. To avoid potential formation of antibodies against injected GH, we used a model with transgenic mice overexpressing bovine GH (bGH). Titanium implants were inserted in the forehead of the mice. 4 months after insertion, the implants were cut out en bloc with the surrounding bone. The calcified specimens were cut and ground to a thickness of approximately 10 microns. Histomorphometry demonstrated significantly more direct bone-to-metal contact in the transgenic mice than in the nontransgenic littermates. Our findings indicate that systemic administration of GH in humans may improve implant integration in bone.  相似文献   

4.
The aim of the present experimental investigation was to study the morphological and dimensional changes of bone, augmented at titanium implants by a membrane technique, taking place after membrane removal. In 12 rabbits, screw-shaped titanium implants were inserted in the tibial metaphyses in such a way that 5 threads became uncovered with bone. Surgery was performed on 2 occasions in order to retrieve specimens with different follow-up times. An e-PTFE barrier and a titanium device were used to provide space for bone formation. In 1 tibia of each rabbit, the membranes and spacers were removed after 8 weeks of healing, and the implants followed for 16 more weeks. Impressions were taken at day 0 and after 8 and 24 weeks of healing and plaster models were produced. In the contralateral tibiae, implants were inserted either 16 or 8 weeks prior to sacrifice. Measurements were made on the plaster models in 3 dimensions at 35 points around each implant in a coordinate measuring machine. Specimens taken 8, 16 and 24 weeks after insertion were analysed by means of light microscopical morphometry. The coordinate measurements showed that, in mean, 1.92 mm of bone had been formed during the first 8 weeks. A statistically significant loss of the height of the newly formed bone (0.70 mm) and thereby reduction of bone volume was found 24 weeks postoperatively. The volume decrease of the newly formed bone was more pronounced beside the implants than over the implant body. The histology showed that woven bone had been formed at the implants after 8 weeks. Further bone formation and remodelling and a net increase of mineralized bone were seen. The degree of bone-implant contact and bone area in the threads increased with time. The present study showed that coordinate measurements on plaster models, obtained from the experimental areas, in combination with histology, form a useful technique to study long-term changes of augmented bone. It was found that bone formed by a barrier membrane technique, decreased in volume during a 16-week follow-up period after barrier removal. Less dimensional changes were observed for the bone formed over the implant body, indicating that a solid surface may have a stabilizing effect on the augmented bone.  相似文献   

5.
Histometric evaluations as a function of time were performed with zirconium implants during the healing period in 10 Wistar rats. The implants (7 mm x 1 mm x 0.1 mm) were placed in the right tibia of the animals. Five rats were killed after 14 days and the remainder were sacrificed 30 days after implantation. The tibiae were resected, radiographed, and embedded in poly(methyl methacrylate). Three cross-sections were obtained transverse to the major axis of each tibia. Osseointegrated tissue thickness, percentage of direct bone-to-implant contact, and osseointegrated tissue volume were evaluated for each specimen. Bone formation was observed on the surface of the implanted strip that was in contact with tibia marrow. This method is proposed for the evaluation of the first stage of healing of bone in contact with different implant materials subjected to various surface treatment.  相似文献   

6.
This pilot study analyzed the bone reactions to early loaded titanium plasma-sprayed implants. A total of 24 titanium plasma-sprayed implants (12 in the maxilla and 12 in the mandible) (Primary Healing Implant, Legnano) were inserted into four Macaca fascicularis monkeys with instruments specially designed to obtain a precise fit of the implant in the bone socket. A metal superstructure was cemented into 10 mandibular and 10 maxillary implants 15 days after implant insertion. The four remaining implants were used as controls. Eight months after implant placement, a block section was carried out, the defect was filled with nonresorbable hydroxyapatite, and all 24 implants were retrieved. The implants were treated to obtain thin ground sections that were examined under normal and polarized light. Histologic analysis showed that bone was observed around the implant surface in all implants. Morphometric analysis demonstrated that bone lined 67.2% (SD = 3.1%) of the maxillary implant surface, and 80.71% (SD = 4.6%) of the mandibular implant surface. No differences were found in the percentage of bone-implant contact in the control implants. In the loaded implants, however, the bone around the implants had a more compact appearance. The study demonstrated that it is possible to obtain a high percentage of bone-implant contact in early loaded titanium plasma-sprayed implants.  相似文献   

7.
The objective of this study was to analyze the efficacy and correlation between clinical and histologic parameters used to evaluate oral implants. After extraction of the premolars and a healing time of 4 months in 16 Dutch goats, four Br?nemark implants were placed in the maxillary left and right premolar regions. After a healing time of 6 months, followed by another 4 months with the permucosal abutments, the goats were sacrificed and the jaws were block-resected. Before histologic preparation, long-cone radiographs were made and Periotest scores of the implants were recorded. Bone level measured histomorphometrically were found to be 0.85 mm more apically, compared to that measured radiologically (P = .001). Furthermore, statistically significant correlations (P > 0.2) were not found between the Periotest values of the calcium-phosphate-coated and uncoated implants for (1) the first thread in contact with bone, or (2) with the total number of threads in contact with bone. It was concluded that the radiologic data overscored the real marginal bone level around screw-shaped oral implants, and that the Periotest device is neither able to discriminate between the first thread nor between the total number of threads in contact with bone.  相似文献   

8.
We hypothesized that reduced stem stiffness of orthopaedic implants contributes to a high risk of loosening, since interface stresses and relative motions may exceed a tolerable range. To study this hypothesis, three types of load-bearing implant with different stiffnesses were inserted into the tibia of the goat. Histological analysis was performed of bone repair after insertion of the implant, bone ingrowth, interface disruption and loosening. A finite element model of the configuration provided the quantitative range of interface stresses and relative motions for the present experiment. The implants were made out of stainless steel, hollow titanium and a thin titanium core covered with a polyacetal coating. The stiffness ratios of these implants were approximately 10:4:1, respectively. All implants were coated with a layer of hydroxyapatite (HA) in order to minimize the possible biological effects of the different implant materials. Irrespective of the type of implant, there was a repair phase that lasted 6-12 weeks. The stiff implants functioned well. Large areas of bone bonding to the HA layer were found after the repair phase at 12 weeks postoperatively. After 24 weeks, some signs of loosening were observed. More loosening occurred with the hollow titanium and polyacetal implants, mainly during the repair phase. Three hollow titanium and three polyacetal coated implants survived this period, and were killed after 24 weeks. The integrity of the HA layer at the bone-implant interface of the titanium implants was good. In the polyacetal implants, the repair reaction of the cortical bone was incomplete. Bone ingrowth into HA was largely lacking. In conclusion, we found significant differences in the repair and interface reactions around implants of different stiffness. Stiff implants showed favourable initial interface conditions for bone ingrowth. Intermediate and flexible implants provoked unfavourable interface conditions for initial bone ingrowth. The finite element study showed that the flexible stems produce larger micromotions and higher interface stresses at the bone-prosthesis interface than the stiff stems, indicating an explanation for the histological findings.  相似文献   

9.
Since August 1989, 35 consecutive patients were treated with immediate implants to replace 50 teeth requiring extractions as a result of root fractures, endodontic instability, nonrestorable carious lesions, or periodontal disease. Defects relative to the implant were morphologically grouped and were treated for bone regeneration with demineralized freeze-dried crushed cancellous bone (DFDBA), e-PTFE membrane, or both. Thread exposure initially ranged from 4 to 20 threads, while implant lengths varied from 8.5 to 18 mm. The mean implant length was 15 mm, with mean thread exposure of 11.34 threads, or 54% of the threaded length of the implant. Reentry confirmed 100% thread coverage in all but one implant in the no-wall group treated with DFDBA alone. Histologic evaluation of three cases confirmed viability of the regenerated bone. The patients were followed through April 1993, with 49 implants (98%) remaining osseointegrated and functional, supporting the predictability of immediate implant placement. The age of the patients ranged from 16 to 80 years, hence implant placement considerations relative to adolescents are also discussed.  相似文献   

10.
The bone formation around titanium implants with varied surface properties is investigated. Machined and electropolished samples with and without thick, anodically formed surface oxides were prepared, surface characterized and inserted in the cortical bone of rabbits (1, 3 and 6 weeks). Scanning electron microscopy, scanning Auger electron spectroscopy and atomic force microscopy revealed marked differences in oxide thickness, surface topography and roughness, but no significant differences in surface chemical composition, between the different groups of implants. Light microscopic morphology and morphometry showed that all implants were in contact with bone and had a large proportion of bone within the threads at 6 weeks. The smooth, electropolished implants, irrespective of anodic oxidation, were surrounded by less bone than the machined implants after 1 week. After 6 weeks the bone volume as well as the bone-implant contact were lower for the merely electropolished implants than for the other three groups. Our study shows that a high degree of bone contact and bone formation are achieved with titanium implants which are modified with respect to oxide thickness and surface topography. However, the result with the smooth (electropolished) implants indicates that a reduction of surface roughness, in the initial phase, decreases the rate of bone formation in rabbit cortical bone.  相似文献   

11.
The aim of this study was to evaluate clinically, histologically and histometrically the use of anorganic bovine bone matrix (i.e. Bio-oss) as a grafting material for maxillary sinus augmentation procedures. In 4 adult male rhesus monkeys (i.e. Macaca mulatta) the 1st, 2nd and 3rd maxillary molars on one side of the jaws were extracted. The remaining bone between the alveolar crest and the bottom of the sinus was then reduced to 3-4 mm. After 3 months, maxillary sinus augmentation procedures were performed on one side of the jaws in each monkey and the sinuses were grafted with the bovine bone matrix. At that time, 2 IMZ pure titanium plasma coated implants were immediately placed into the augmented sinuses (i.e. simultaneous implants-loaded group). After 4 months, 2 additional similar implants were placed into these previously augmented sinuses (i.e. delayed implants-loaded group). Four months later, the abutment connection was performed and all 4 implants were loaded with a gold-alloy bridge for 6 months (i.e. until sacrifice of the animals). The contralateral side of each monkey received the same treatment with the exception that the extractions were performed 7 months after those in the opposite side and that the implants in this side were not loaded. Thus, 2 additional study groups (i.e. simultaneous implants-unloaded group and delayed implants-unloaded group) were obtained. Clinically, all loaded implants were stable at the day of sacrifice. Histologically, the grafted sinuses exhibited significant bone formation with integration of the bovine bone matrix particles to the new bone. Direct mineralized bone-to-implant contact was greater for the delayed implant placement groups than for the implants installed simultaneously with the sinus augmentation. Furthermore, the percentage of direct mineralized bone-to-implant contact was greater in the residual bone than in the augmented area. It was concluded that the anorganic bovine bone matrix facilitated bone formation and implant osseointegration in the augmented sinuses and that the delayed implant placement in combination with the sinus augmentation procedure seemed to be preferable.  相似文献   

12.
This study examined the influence of diabetes mellitus on bone formation around cylindrical titanium (Ti) implants (1.0 mm in diameter and 1.5 mm in length) inserted transcortically and extending into the medullary canal of rat tibiae using light and fluorescence microscopies and image processing. Forty-eight male Wistar King A rats (age 5 weeks) were used in this experiment. Streptozotocin was injected intraperitoneally to induce diabetes and the serum glucose concentration was checked to ensure the induction of diabetes prior to implant placement and at the time of sacrifice. The animals were sacrificed 7, 28, 56, or 84 days after placement. Toluidine blue-stained undecalcified sections were prepared for histological observation and image analysis. The Ti implants in the control group became increasingly encapsulated with a bone layer. The implants in the diabetes-induced (DI) group were also surrounded with a thin bone layer. Abundant adipocytes were observed in the DI group as compared with the control group. Quantitative evaluation indicated that the control group showed a significantly higher percent of bone contact, and thickness of surrounding bone and area than the DI group. Consequently, the present study suggests that uncontrolled diabetes would hinder bone formation around Ti implants in rats.  相似文献   

13.
Many studies have shown enhanced bone apposition to implants coated with hydroxyapatite, but the optimum implant texture, especially in abnormal trabecular bone, is unclear. The purpose of this project was to evaluate the histological and mechanical properties of cylindrical implants with three different surface textures that were placed in the cancellous bone of the distal femur of the rabbit after the production of an inflammatory knee arthritis. The three implant surfaces included a beaded surface (Group A), a beaded surface coated with hydroxyapatite (Group B), and a smooth surface coated with hydroxyapatite (Group C). The right knees of 36 rabbits were injected with carrageenan twice a week for 2 weeks. Then bilateral implantations were performed, with 12 rabbits in each group receiving identical implants in the right and left knees. The rabbits were killed 6 weeks after surgery. Mechanical (push-out test) and histomorphometric analyses were performed to determine the quality and quantity of bone ingrowth. In Group A, there was virtually no direct contact (a 20-60-microm clearance) between the bone and the beaded surfaces. Direct contact between the bone and the implant surfaces was seen in Groups B and C. The thickness and number of trabeculae were smaller on the arthritic side than on the control side for all groups but were not different between groups for either the control or the arthritic side. Mechanical testing showed that the shear strength of the interface was weaker on the arthritic side in all groups. The results suggest that inflammatory arthritis induced by carrageenan may influence the quality of local bone (osteopenic changes) and hence compromise the bone apposition and mechanical stability of the interface between the implant and bone.  相似文献   

14.
The aim of this study was to evaluate guided bone regeneration (GBR) around dental implants placed in atrophic alveolar ridges using an experimental, nonporous bioresorbable barrier. In 8 Rhesus monkeys, the maxillary canines and lateral incisors were extracted bilaterally and the remaining alveoli were reduced to create atrophic ridges. After a healing period of 3 months, soft tissue expansion was performed using a subperiosteal tissue expander. After 1 month of tissue expansion, and IMZ implant was placed in the atrophic ridge on each side in such a way that its coronal 4 mm to 5 mm remained circumferentially exposed above the bone level. The test implants were covered with a bioresorbable barrier made of poly (D,L-lactid-co-trimethylencarbonate) in a 70/30 ratio, whereas the control implants were covered with a nonresorbable expanded polytetrafluoroethylene (e-PTFE) barrier. The e-PTFE barriers were stabilized with titanium minipins while the bioresorbable barriers were analogously fixed using bioresorbable minipins made of poly (L-lactid-co-D,L-lactid) 70/30. Clinical healing progressed uneventfully in both groups and no soft tissue dehiscences occurred. Histometric and histomorphometric analyses were performed 5 months post surgery. Both test and control implants exhibited direct bone-to-implant contact to variable extents. The mean direct mineralized bone-to-implant contact length fraction was 32% of the total implant length in the test sites and 58% in the control sites. Control sites exhibited significantly greater bone fill compared to the experimental sites (P < 0.001). Histologic observations of test specimens demonstrated a moderate inflammatory reaction related to the degradation and resorption products of the barrier. In conclusion, the nonresorbable e-PTFE GBR barrier was found to be superior to the bioresorbable barriers tested in the present investigation.  相似文献   

15.
The specific aim of this study was to determine the response of alveolar bone after it was augmented vertically using distraction osteogenesis and subsequently loaded with implant restorations. Four dogs each had four implants placed horizontally into an edentulous mandibular quadrant and, after integration, a distraction osteogenesis device was fabricated in the laboratory. An osteotomy was made to allow the crest of the alveolar ridge to be distracted vertically. After 10 mm of vertical distraction, the device was stabilized with light cured resin. Following bone fill confirmation of the distraction gap at 10 weeks, two implants were placed into the ridges, one in distracted bone and one in nondistracted bone. After 4 months for implant integration, freestanding prostheses were fabricated. Crestal bone levels were evaluated throughout the period of function. Animals were sacrificed after 1 year of loading, for histologic evaluation of the bone. The vertical ridge augmentation averaged 8.85 +/- 1.05 mm after 10 weeks of healing following distraction, without change over 1 year of implant loading. Histologic examination showed that bone had formed between the distracted segments, creating an augmented ridge. The average thickness of the labial cortex in the distraction gap was significantly thinner than the lingual cortex in distracted bone and the lingual and labial nondistracted cortical bone. The presence of the dental implant did not significantly affect cortical bone thickness. Serial sections showed that implants remained integrated and functional without soft tissue inflammation. Dental implants placed into alveolar ridges augmented with the technique of distraction osteogenesis maintained bone and were functional for the length of this study.  相似文献   

16.
The response of mandibular bone to identical geometry LTI carbon, carbon-coated aluminum oxide, and uncoated aluminum oxide blade-type dental implants in baboons for 2 years was evaluated using histologic, microradiographic, and scanning electron microscopic methods. In addition, a quantitative histologic analysis was performed identifying the type, amount, and distribution of tissue surrounding the dental implant systems. This is the final phase of a study investigating the effect of implant elastic modulus and implant surface chemical composition on the performance of dental implants. Previous studies have utilized clinical and radiographic evaluations, postretrieval mechanical testing, and finite element stress analysis to evaluate the dental implant performance. The results of the histologic study revealed a direct implant-bone interface with no intervening soft tissue in 16 of the 21 implants (76%). A fibrous tissue interface was observed in 5 of 21 implants (24%). Quantitative histologic results for the implants with a direct implant-bone interface showed statistically larger crestal cortical plates (p less than 0.05) and greater area fraction crestal cancellous bone (p less than 0.05) in the LTI carbon implant compared to the carbon-coated and uncoated aluminum oxide implants. The carbon-coated and uncoated aluminum oxide implants demonstrated statistically greater area fraction cancellous bone at the inferior region of the implant (p less than 0.05) and thinned and reduced crestal cortical plates when compared to the LTI carbon implants. The results indicate that significant stress shielding of the crestal bone had occurred with the rigid carbon-coated and uncoated aluminum oxide implants when compared to the LTI carbon implants which had a material elastic modulus similar to cortical bone. Based upon the histologic results, it appears that the LTI carbon implants with the direct implant-bone interface exhibited a greater potential for long-term successful performance compared to the aluminum oxide substrate implants.  相似文献   

17.
RATIONALE AND OBJECTIVES: We developed a method for volumetric image deblurring in spiral (helical) computed tomography (CT) scanning with a three-dimensional (3D) Gaussian point spread function (PSF) to improve the quality of temporal bone spiral CT images for assessing the position of cochlear implants electrodes. METHODS: A patient was scanned after cochlear implantation, and the temporal bone was reconstructed into a volume with 128 voxels per dimension, 0.1 mm per voxel side, and x 10 gray-scale expansion. The 3D PSF in spiral CT imaging was assumed to be Gaussian separable transversely and longitudinally. Standard deviations of the PSF were derived and subjectively adjusted. The image was then deconvolved using Wiener filtering and maximum-likelihood deconvolution methods. Image quality was assessed both visually and quantitatively using cross-sectional area at half of the maximum (CAHM) of the implanted array as the figure of merit. RESULTS: Substantial image deblurring was achieved via deconvolution. Subjectively, anatomic structures were more clearly shown. Deconvolution reduced the CAHM by approximately one third, on average. Three-dimensional deconvolution had better image quality than two-dimensional deconvolution. The maximum-likelihood method produced superior image quality but took longer to process relative to Wiener filtering. CONCLUSION: Volumetric image deblurring is practical with a Gaussian PSF. The maximum-likelihood method is preferred if time permits. Deconvolution facilitates the study of fine details of the temporal bone and cochlear implant.  相似文献   

18.
钼棒材的均匀性对后续产品质量有着重要影响。将一根覫90 mm纯钼棒沿纵向和横向均匀切割,获得边部和芯部各30个检测样本,通过对试样的晶粒数、硬度、密度的检测和C、O、Fe、K含量测试,根据检测数据的分布,评价了试样的均匀性。  相似文献   

19.
Osseointegration is a histometric process that occurs gradually over a period of time. The load that an implant is able to bear depends upon, among other parameters, the quality of the bone-implant contact. For 8 years the damping capacity of 1,182 Br?nemark implants inserted consecutively in 315 patients was measured using the Periotest method. The following clinical observations were made: (1) a relationship was found between implants with a specific Periotest value range that, at the moment of the transepithelial connection, were considered to be clinically stable, asymptomatic, and whose radiograph image was not radiolucent; (2) a relationship was found between clinically nonintegrated implants with a different Periotest value range; (3) variations in the Periotest value were related to the type of bone in which the implant was placed; (4) a small percentage of borderline implants with a Periotest value between the osseointegrated and the nonosseointegrated Periotest values was detected; (5) the percentage of secondary failures was related to an initial Periotest value corresponding to a borderline implant; (6) the healing time of each implant was individualized in accordance with the successively obtained Periotest value; (7) the load and the design of the prosthesis were individualized; (8) early detection of failing implants before fabrication of prostheses is possible; (9) communication was improved between the surgeon and the prosthodontist; and (10) variations in Periotest value were related to bone remodeling. The sensitivity of the principal clinical test in evaluating osseointegration is discussed regarding the moment of its application. The use of Periotest values as an initial success criteria of an implant is proposed.  相似文献   

20.
The authors present a histologic analysis of 19 Branemark titanium implants retrieved for different causes: four implants were removed for abutment fracture, one for dental nerve dysesthesia, two for bone overheating, two for peri-implantitis, nine for mobility, one for unknown causes. In the implants removed for fracture a high bone-implant contact percentage was present (71.83 +/- 4.96%) with compact, mature bone at the interface. The picture of the failure due to bone overheating was characteristic with the presence of bone sequestra and of a gap between implant and bone filled by lymphocytes and plasma cells: many bacteria surrounded the necrotic bone and no newly regenerated bone was present. In peri-implantitis an inflammatory infiltrate was observed in the peri-implant tissues: a dense fibrous connective tissue was present around implants failed for mobility. The microscopical picture is certainly extremely important in identifying the causal determinants of an implant failure.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号