首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this paper, a novel integrated solar photovoltaic thermal absorption desalination system for freshwater and cooling production is proposed and analyzed thermodynamically. Ammonia–water pair is considered as a working fluid for the absorption system. Effect of average solar radiation for different months, time period of solar radiation availability in Abu Dhabi, salinity of seawater, and temperature of the seawater on energetic and exergetic COPs, production rate of freshwater, and overall performance of the system are investigated under different operating conditions. It is found that energetic and exergetic COPs, production rate of freshwater, energetic and exergetic utilization factors, and performance ratios vary greatly from one month to another because of the dynamic variation in solar radiation and its time of availability. The highest amount of freshwater is produced in the month of July as calculated to be 152 kg/h for a collector area of 100 m2 and solar power of 4.8 kW. The highest energetic and exergetic COPs and utilization factors are also obtained for the month of July. Moreover, the highest performance ratio is found to be 0.056 as obtained in the month of July when solar radiation intensity is highest as available for more than half of a day. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

2.
In this article, a thermodynamic investigation of solar power tower assisted multigeneration system with hydrogen production and liquefaction is presented for more environmentally-benign multigenerational outputs. The proposed multigeneration system is consisted of mainly eight sub-systems, such as a solar power tower, a high temperature solid oxide steam electrolyzer, a steam Rankine cycle with two turbines, a hydrogen generation and liquefaction cycle, a quadruple effect absorption cooling process, a drying process, a membrane distillation unit and a domestic hot water tank to supply hydrogen, electrical power, heating, cooling, dry products, fresh and hot water generation for a community. The energetic and exergetic efficiencies for the performance of the present multigeneration system are found as 65.17% and 62.35%, respectively. Also, numerous operating conditions and parameters of the systems and their effects on the respective energy and exergy efficiencies are investigated, evaluated and discussed in this study. A parametric study is carried out to analyze the impact of various system design indicators on the sub-systems, exergy destruction rates and exergetic efficiencies and COPs. In addition, the impacts of varying the ambient temperature and solar radiation intensity on the irreversibility and exergetic performance for the present multigeneration system and its components are investigated and evaluated comparatively. According to the modeling results, the solar irradiation intensity is found to be the most influential parameter among other conditions and factors on system performance.  相似文献   

3.
Renewable energy-based hydrogen production plants can offer potential solutions to both ensuring sustainability in energy generation systems and designing environmentally friendly systems. In this combined work, a novel solar energy supported plant is proposed that can generate hydrogen, electricity, heating, cooling and hot water. With the suggested integrated plant, the potential of solar energy usage is increased for energy generation systems. The modeled integrated system generally consists of the solar power cycle, solid oxide fuel cell plant, gas turbine process, supercritical power plant, organic Rankine cycle, cooling cycle, hydrogen production and liquefaction plant, and hot water production sub-system. To conduct a comprehensive thermodynamic performance analysis of the suggested plant, the combined plant is modeled according to thermodynamic equilibrium equations. A performance assessment is also conducted to evaluate the impact of several plant indicators on performance characteristics of integrated system and its sub-parts. Hydrogen production rate in the suggested plant according to the performance analysis performed is realized as 0.0642 kg/s. While maximum exergy destruction rate is seen in the solar power plant with 8279 kW, the cooling plant has the lowest exergy destruction rate as 1098 kW. Also, the highest power generation is obtained from gas turbine cycle with 7053 kW. In addition, energetic and exergetic efficiencies of solar power based combined cycle are found as 56.48% and 54.06%, respectively.  相似文献   

4.
This paper investigates the performance of a hydrogen refueling system that consists of a polymer electrolyte membrane electrolyzer integrated with photovoltaic arrays, and an electrochemical compressor to increase the hydrogen pressure. The energetic and exergetic performance of the hydrogen refueling station is analyzed at different working conditions. The exergy cost of hydrogen production is studied in three different case scenarios; that consist of i) off-grid station with the photovoltaic system and a battery bank to supply the required electric power, ii) on-grid station but the required power is supplied by the electric grid only when solar energy is not available and iii) on-grid station without energy storage. The efficiency of the station significantly increases when the electric grid empowers the system. The maximum energy and exergy efficiencies of the photovoltaic system at solar irradiation of 850 W m-2 are 13.57% and 14.51%, respectively. The exergy cost of hydrogen production in the on-grid station with energy storage is almost 30% higher than the off-grid station. Moreover, the exergy cost of hydrogen in the on-grid station without energy storage is almost 4 times higher than the off-grid station and the energy and exergy efficiencies are considerably higher.  相似文献   

5.
In this paper, we propose a novel integrated geothermal absorption system for hydrogen liquefaction, power and cooling productions. The effect of geothermal, ambient temperature and concentration of ammonia-water vapor on the system outputs and efficiencies are studied through energy and exergy analyses. It is found that both energetic and exergetic coefficient of performances (COPs), and amounts of hydrogen gas pre-cooled and liquefied decrease with increase in the mass flow rate of geothermal water. Moreover, increasing the temperature of geothermal source degrades the performance of the quadruple effect absorption system (QEAS), but at the same time it affects the liquefaction production rate of hydrogen gas in a positive way. However, an increase in ambient temperature has a negative effect on the liquefaction rate of hydrogen gas produced as it decreases from 0.2 kg/s to 0.05 kg/s. Moreover, an increase in the concentration of the ammonia-water vapor results in an increase in the amount of hydrogen gas liquefied from 0.07 kg/s to 0.11 kg/s.  相似文献   

6.
In this article, an extensive thermodynamic performance assessment for the useful products from the solar tower and high-temperature steam electrolyzer assisted multigeneration system is performed, and also its sustainability index is also investigated. The system under study is considered for multi-purposes such as power, heating, cooling, drying productions, and also hydrogen generation and liquefaction. In this combined plant occurs of seven sub-systems; the solar tower, gas turbine cycle, high temperature steam electrolyzer, dryer process, heat pump, and absorption cooling system with single effect. In addition, the energy and exergy performance, irreversibility and sustainability index of multigeneration system are examined according to several factors, such as environment temperature, gas turbine input pressure, solar radiation and pinch point temperature of HRSG. Results of thermodynamic and sustainability assessments show that the total energetic and exergetic efficiency of suggested paper are calculated as 60.14%, 58.37%, respectively. The solar tower sub-system has the highest irreversibility with 18775 kW among the multigeneration system constituents. Solar radiation and pinch point temperature of HRSG are the most critical determinants affecting the system energetic and exergetic performances, and also hydrogen production rate. In addition, it has been concluded that, the sustainability index of multigeneration suggested study has changed between 2.2 and 3.05.  相似文献   

7.
In this paper, a combined power plant based on the dish collector and biomass gasifier has been designed to produce liquefied hydrogen and beneficial outputs. The proposed solar and biomass energy based combined power system consists of seven different subplants, such as solar power process, biomass gasification plant, gas turbine cycle, hydrogen generation and liquefaction system, Kalina cycle, organic Rankine cycle, and single-effect absorption plant with ejector. The main useful outputs from the combined plant include power, liquid hydrogen, heating-cooling, and hot water. To evaluate the efficiency of integrated solar energy plant, energetic and exergetic effectiveness of both the whole plant and the sub-plants are performed. For this solar and biomass gasification based combined plant, the generation rates for useful outputs covering the total electricity, cooling, heating and hydrogen, and hot water are obtained as nearly 3.9 MW, 6584 kW, 4206 kW, and 0.087 kg/s in the base design situations. The energy and exergy performances of the whole system are calculated as 51.93% and 47.14%. Also, the functional exergy of the whole system is calculated as 9.18% for the base working parameters. In addition to calculating thermodynamic efficiencies, a parametric plant is conducted to examine the impacts of reference temperature, solar radiation intensity, gasifier temperature, combustion temperature, compression ratio of Brayton cycle, inlet temperature of separator 2, organic Rankine cycle turbine and pump input temperature, and gas turbine input temperature on the combined plant performance.  相似文献   

8.
In this paper, a parametric study of the triple effect absorption cooling system (TEACS) integrated with solar photo-voltaic/thermal (PV/T), geothermal, and Linde–Hampson cycle is conducted. The effect of different operating parameters on the COPs, ratio ‘n’, amount of hydrogen gas pre-cooled, amount of hydrogen liquefied, and utilization factor of the integrated system are studied. It is found that when mass flow rate of air increases the energetic and exergetic COPs decrease in an exponential form from 2.6 to 1.9, and 0.4 to 0.3, respectively. The amounts of hydrogen gas pre-cooled and hydrogen liquefied decrease from 0.39 kg/s to 0.32 kg/s and 0.082 kg/s and 0.066 kg/s, respectively with increase in mass flow rate of air. Moreover, the amounts of hydrogen gas pre-cooled and hydrogen liquefied decrease from 0.42 to 0.27, and 0.088 to 0.066, respectively with increase in mass flow rate of geothermal. In addition, energetic and exergetic utilization factors of integrated system decrease from 0.059 to 0.037, and 0.21 and 0.13, respectively with increase in mass flow rate of geothermal.  相似文献   

9.
In this study, exergoeconomic and environmental impact analyses, through energy, exergy, and sustainability assessment methods, are performed to investigate a hybrid version renewable energy (including wind and solar) based hydrogen and electricity production system. The dead state temperatures considered here are 10 °C, 20 °C and 30 °C to undertake a parametric study. An electrolyzer and a metal hydride tank are used for hydrogen production and hydrogen storage, respectively. Also, the Proton Exchange Membrane Fuel Cell (PEMFC) and battery options are utilized for electricity generation and storage, respectively. As a result, the energy and exergy efficiencies and the sustainability index for the wind turbine are found to be higher than the ones for solar photovoltaic (PV) system. Also, the overall exergy efficiency of the system is found to be higher than the corresponding overall energy efficiency. Furthermore, for this system, it can be concluded that wind turbine with 60 gCO2/month is more environmentally-benign than the solar PV system with 75 gCO2/month. Finally, the total exergoeconomic parameter is found to be 0.26 W/$, when the energy loss is considered, while it is 0.41 W/$, when the total of exergy loss and destruction rates are taken into account.  相似文献   

10.
In this paper, a solar power-based combined plant for power, hydrogen, methane, ammonia and urea production is proposed. A parabolic trough collector is utilized for the system prime mover. Moreover, steam Rankine cycle, organic Rankine cycle, hydrogen production and compression subsystem, ammonia, methane and urea production units, single-effect absorption cooling unit, and freshwater production plant are integrated together to develop the present system for better system performance and cost-effectiveness and reduced environmental impact. In order to analyze and evaluate the proposed multigeneration plant, thermodynamic, parametric and economic studies are performed. According to the assessment results, it is found that energetic and exergetic efficiencies of the present multigeneration plant are 66.12% and 61.56%, respectively. The comparisons of the subsystem and overall plant efficiencies show that the highest energetic and energetic efficiencies belong to freshwater production plant by 79.24% and 75.62%, respectively. In addition, the present parametric analysis indicates that an increase in the reference temperature, solar radiation intensity and working pressure of the solar process has a positive effect on the plant's performance. The cost analysis reveals that as the solar radiation intensity and the working pressure of the solar process increase, the hydrogen generation cost decreases. Furthermore, the hydrogen generation cost is achieved to be 1.94 $/kgH2 at 650 W/m2 of the solar radiation intensity, with other parameters remaining constant.  相似文献   

11.
The present study develops a new solar and geothermal based integrated system, comprising absorption cooling system, organic Rankine cycle (ORC), a solar-driven system and hydrogen production units. The system is designed to generate six outputs namely, power, cooling, heating, drying air, hydrogen and domestic hot water. Geothermal power plants emit high amount of hydrogen sulfide (H2S). The presence of H2S in the air, water, soils and vegetation is one of the main environmental concerns for geothermal fields. In this paper, AMIS(AMIS® - acronym for “Abatement of Mercury and Hydrogen Sulphide” in Italian language) technology is used for abatement of mercury and producing of hydrogen from H2S. The present system is assessed both energetically and exergetically. In addition, the energetic and exergetic efficiencies and exergy destruction rates for the whole system and its parts are defined. The highest overall energy and exergy efficiencies are calculated to be 78.37% and 58.40% in the storing period, respectively. Furthermore, the effects of changing various system parameters on the energy and exergy efficiencies of the overall system and its subsystems are examined accordingly.  相似文献   

12.
A renewable energy based integrated system is developed to meet the total energy demands of a house located off-grid, and a thermodynamic analysis through energy and exergy methodologies is conducted for analysis, evaluation, and performance assessment. The present novel multigeneration system is mainly driven through the animal residues produced at the farm house. The proposed novel system is composed of nine main units namely, a biomass combustor, photovoltaic (PV) panels, parabolic solar trough collectors, thermoelectric generators, organic Rankine cycle, electrolyzer, homogeneous charged compression ignition (HCCI) engine, absorption chiller, and reverse osmosis (RO) unit. Biomass combustor runs an organic Rankine turbine for additional power during peak loads. The exhaust of gas turbine generates cooling to meet the cooling demand of the residential area of the farm house. PV panels are incorporated to generate hydrogen through electrolyzer. A HCCI engine generates power to compensate peak load as well as charging the farming vehicles of the farm house. The RO unit with energy recovery Pelton turbine produces fresh water for farming and residential use. The advanced integration of subsystems, thermoelectric generators and efficient utilization of waste, improves significant amount of energetic and exergetic efficiencies of overall multigenerational system. The energy and exergy efficiencies are enhanced in the order of 4.8% and 6.3%, respectively, after incorporating innovative cooling system to the PV modules. The overall energy and exergy efficiencies of the proposed multigeneration system with and without thermoelectric are found to be 67.6% and 57.1%, and 68.9% and 58.4%, respectively.  相似文献   

13.
Hydrogen is an essential component of power-to-gas technologies that are needed for a complete transition to renewable energy systems. Although hydrogen has zero GHG emissions at the end-use point, its production could become an issue if non-renewable, and pollutant energy and material resources are used in this step. Therefore, a crucial step for the fully developed hydrogen economy is to find alternative hydrogen production methods that are clean, efficient, affordable, and reliable. With this motivation, in this study, an integrated and continuous type of hydrogen production system is designed, developed, and investigated. This system has three components. There is a solar spectral splitting device (Unit I), which splits the incoming solar energy into two parts. Photons with longer wavelength is sent to the photovoltaic thermal hybrid solar collector, PV/T, (Unit II) and used for combined heat and power generation. Then the remaining part is transferred to the novel hybrid photoelectrochemical-chloralkali reactor (Unit III) for simultaneous H2, Cl2, and NaOH production. This system has only one energy input, which is the solar irradiation and five outputs, namely H2, Cl2, NaOH, heat, and electricity. Unlike most of the studies in the literature, this system does not use only PV or only a photoelectrochemical reactor. With this approach, solar energy utilization is maximized, and the wasted portion is minimized. By selecting PV/T rather than PV, the performance of the panels is maximized because recovering the by-product heat as a system output in addition to electricity, and the PV/T has less waste and higher efficiency. The present reactor does not use any additional electron donors, so the wastewater discharge is only depleted NaCl solution, which makes the system significantly cleaner than the ones available in the literature. The specific aim of this study is to demonstrate the optimum operating parameters to reach the maximum achievable production rates and efficiencies while keeping the exergy destruction as little as possible. In this study, there are four case studies, and in each case study, one decision variable is optimized to get the desired performance results. Within the selected operating parameter range, all performance criteria (except exergy destruction) are normalized and ranked for proper comparison. The maximum production rates and efficiencies with the least possible exergy destruction are observed at the operating temperature of 30 °C. At 30 °C, 4.18 g/h H2, 127.55 g/h Cl2, 151 W electricity, and 716 W heat are produced with an exergy destruction rate of 95.74 W and 78% and 30% energy and exergy efficiencies, respectively.  相似文献   

14.
A new configuration of solar energy-driven integrated system for ammonia synthesis and power generation is proposed in this study. A detailed dynamic analysis is conducted on the designed system to investigate its performance under different radiation intensities. The solar heliostat field is integrated to generate steam that is provided to the steam Rankine cycle for power generation. The significant amount of power produced is fed to the PEM electrolyser for hydrogen production after covering the system requirements. A pressure swing adsorption system is integrated with the system that separates nitrogen from the air. The produced hydrogen and nitrogen are employed to the cascaded ammonia production system to establish increased fractional conversions. Numerous parametric studies are conducted to investigate the significant parameters namely; incoming beam irradiance, power production using steam Rankine cycle, hydrogen and ammonia production and power production using TEGs and ORC. The maximum hydrogen and ammonia production flowrates are revealed in June for 17th hour as 5.85 mol/s and 1.38 mol/s and the maximum energetic and exergetic efficiencies are depicted by the month of November as 25.4% and 28.6% respectively. Moreover, the key findings using the comprehensive dynamic analysis are presented and discussed.  相似文献   

15.
In the proposed study, the thermodynamic performance assessment of ocean thermal energy conversion (OTEC) based hydrogen generation and liquefaction system are evaluated. In this context, the energetic and exergetic analyses of integrated system are conducted for multigeneration. This integrated process is consisted of the heat exchangers, turbine, condenser, pumps, solar collector system, hot storage tank, cold storage tank and proton exchange membrane (PEM) electrolyzer. In addition to that, the impacts of different design indicators and reference ambient parameters on the exergetic performance and exergy destruction rate of OTEC based hydrogen production system are analyzed. The energetic and exergetic efficiencies of integrated system are founded as 43.49% and 36.49%, respectively.  相似文献   

16.
In this paper, a new renewable energy-based cogeneration system for hydrogen and electricity production is developed. Three different methods for hydrogen production are integrated with Rankine cycle for electricity production using solar energy as an energy source. In addition, a simple Rankine cycle is utilized for producing electricity. This integrated system consists of solar steam reforming cycle using molten salt as a heat carrier, solar steam reforming cycle using a volumetric receiver reactor, and electrolysis of water combined with the Rankine cycle. These cycles are simulated numerically using the Engineering Equation Solver (EES) based on the thermodynamic analyses. The overall energetic and exergetic efficiencies of the proposed system are determined, and the exergy destruction and entropy generation rates of all subcomponents are evaluated. A comprehensive parametric study for evaluating various critical parameters on the overall performance of the system is performed. The study results show that both energetic and exergetic efficiencies of the system reach 28.9% and 31.1%, respectively. The highest exergy destruction rates are found for the steam reforming furnace and the volumetric receiver reforming reactor (each with about 20%). Furthermore, the highest entropy generation rates are obtained for the steam reforming furnace and the volumetric receiver reforming reactor, with values of 174.1 kW/K and 169.3 kW/K, respectively. Additional parametric studies are undertaken to investigate how operating conditions affect the overall system performance. The results report that 60.25% and 56.14% appear to be the highest exergy and energy efficiencies at the best operating conditions.  相似文献   

17.
A novel configuration of hybrid wind-solar PV based cascaded ammonia synthesis is proposed in this article. A comprehensive dynamic analysis is conducted in this study which is substantial to explore the system functionality under different atmospheric conditions as the power achieved by the wind farm source is dependent on the wind speed and power extracted from the solar PV source depends upon solar radiation intensities. The system is designed to supply the electrical output extracted from the wind-solar PV sources to the proton exchange membrane electrolyser after meeting the system work requirements for hydrogen production. The produced hydrogen reacts with nitrogen separated from pressure swing adsorption to synthesize ammonia. A cascaded ammonia synthesis system is employed in this study to achieve high fractional conversion and simulated using Aspen Plus V11. Toronto is chosen as the geographical location for the dynamic simulation. The minimum exergetic efficiency is found to be 19.21% during the month of December and maximum exergetic efficiency is determined as 26.06% during the month of April. Similarly, the minimum energetic efficiency is found to be 18% during December and maximum energetic efficiency was determined as 24.42% during the month of April. In addition, the results obtained from comprehensive dynamic analyses are presented and discussed.  相似文献   

18.
Parabolic dish solar collector system has capability to gain higher efficiency by converting solar radiations to thermal heat due to its higher concentration ratio. This paper examines the exergo-economic analysis, net work and hydrogen production rate by integrating the parabolic dish solar collector with two high temperature supercritical carbon dioxide (s-CO2) recompression Brayton cycles. Pressurized water (H2O) is used as a working fluid in the solar collector loop. The various input parameters (direct normal irradiance, ambient temperature, inlet temperature, turbine inlet temperature and minimum cycle temperature) are varied to analyze the effect on net power output, hydrogen production rate, integrated system energetic and exergetic efficiencies. The simulations has been carried out using engineering equation solver (EES). The outputs demonstrate that the net power output of the integrated reheat recompression s-CO2 Brayton system is 3177 kW, whereas, without reheat integrated system has almost 1800 kW net work output. The overall energetic and exergetic efficiencies of former system is 30.37% and 32.7%, respectively and almost 11.6% higher than the later system. The hydrogen production rate of the solarized reheat and without reheat integrated systems is 0.0125 g/sec and 0.007 g/sec, accordingly and it increases with rise in direct normal irradiance and ambient temperature. The receiver has the highest exergy destruction rate (nearly 44%) among the system components. The levelized electricity cost (LEC) of 0.2831 $/kWh with payback period of 9.5 years has proved the economic feasibility of the system design. The increase in plant life from 10 to 32 years with 8% interest rate will decrease the LEC from (0.434-0.266) $/kWh. Recuperators have more potential for improvement and their cost rate of exergy is higher as compared to the other components.  相似文献   

19.
In this paper, an attempt is made to investigate the performance characteristics of a photovoltaic (PV) and photovoltaic-thermal (PV/T) system based on energy and exergy efficiencies, respectively. The PV system converts solar energy into DC electrical energy where as, the PV/T system also utilizes the thermal energy of the solar radiation along with electrical energy generation. Exergy efficiency for PV and PV/T systems is developed that is useful in studying the PV and PV/T performance and possible improvements. Exergy analysis is applied to a PV system and its components, in order to evaluate the exergy flow, losses and various efficiencies namely energy, exergy and power conversion efficiency. Energy efficiency of the system is calculated based on the first law of thermodynamics and the exergy efficiency, which incorporates the second law of thermodynamics and solar irradiation exergy values, is also calculated and found that the latter is lower for the electricity generation using the considered PV system. The values of “fill factor” are also determined for the system and the effect of the fill factor on the efficiencies is also evaluated. The experimental data for a typical day of March (27th March 2006) for New Delhi are used for the calculation of the energy and exergy efficiencies of the PV and PV/T systems. It is found that the energy efficiency varies from a minimum of 33% to a maximum of 45% respectively, the corresponding exergy efficiency (PV/T) varies from a minimum of 11.3% to a maximum of 16% and exergy efficiency (PV) varies from a minimum of 7.8% to a maximum of 13.8%, respectively.  相似文献   

20.
In this study, a new solar power assisted multigeneration system designed and thermodynamically analyzed. In this system, it is designed to perform heating, cooling, drying, hydrogen and power generation with a single energy input. The proposed study consists of seven sub-parts which are namely parabolic dish solar collector, Rankine cycle, organic Rankine cycle, PEM-electrolyzer, double effect absorption cooling, dryer and heat pump. The effects of varying reference temperature, solar irradiation, input and output pressure of high-pressure turbine and pinch point temperature heat recovery steam generator are investigated on the energetic and exergetic performance of integration system. Thermodynamic analysis result outputs show that the energy and exergy performance of overall study are computed as 48.19% and 43.57%, respectively. Moreover, the highest rate of irreversibility has the parabolic dish collector with 24,750 kW, while the lowest rate of irreversibility is calculated as 5745 kW in dryer. In addition, the main contribution of this study is that the solar-assisted multi-generation systems have good potential in terms of energy and exergy efficiency.  相似文献   