首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Yan Wang  Fan Wu  Peihong Wu 《火与材料》2020,44(2):283-295
This paper investigates the effects of passenger blockage on smoke flow properties in longitudinally ventilated tunnel fires. A series of numerical simulations were conducted in a 1/5 small-scale tunnel with the different heat release rates (50-100 kW), longitudinal ventilation velocities (0.5-1 m/s), passenger blockage lengths (2-6 m), and ratios (0.17-0.267). The typical smoke flow properties in different tunnel fire scenarios are analyzed, and the results show that under the same heat release rate and longitudinal ventilation velocity, the smoke back-layering length, maximum smoke temperature, and downstream smoke layer height decrease with increasing passenger blockage length or ratio. The Li correlations can well predict the smoke back-layering length and maximum smoke temperature in tunnel fire scenarios without the passenger blockage. When the passenger blockage exists, the modified local ventilation velocity that takes the blockage length and ratio into account has been proposed to correct the Li correlations. The smoke back-layering length and maximum smoke temperature with the different blockage lengths and ratios can be predicted by the modified correlations, which are shown to well reproduce the simulation results.  相似文献   

2.
Fires in enclosures equipped with mechanical ventilation remain one of the key issues for fire safety assessment in multifamily homes and industries. Therefore, a wide variation of methods for preventing smoke spread through the ventilation system exist and are applied, in performance‐based designs. Through the use of the heating, ventilation and air conditioning (HVAC) model in the fire dynamics simulator, several different common and less common methods for preventing smoke spread in the ventilation system were tested. The effects on smoke spread with changing building leakage and fire growth rates were also investigated. The results were evaluated by determining the total soot spread from the fire room to other compartments connected to the ventilation system, as well as soot/thermal load on the fans and system in general. The maximum and average heat release rate was also of interest and hence compared between systems. It was found that, while many methods perform similar, a few proven methods, such as fire and smoke dampers, performed very well with very little smoke spread to the rest of the system. The study should be considered as an introduction to implementing a similar methodology in specific cases because different ventilations systems will present very different challenges and weaknesses. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

3.
Large confined space has high incidence of fires, which seriously threatens the safety of people working there. Understanding the distribution of smoke in such large space is critical to fire development prediction and smoke control. Three improved methods for the stratification interface prediction of fire smoke are developed, including of improved intra-variance, integral ratio and N-percentage methods. In these methods, the interface height is determined by the vertical temperature distribution based on a three-layer smoke zone model, which is an improvement of a two-layer zone model. Thereafter, the three improved methods are applied to several typical fire cases simulated CFD to predict the smoke interface, and their applicability and reliability are verified by comparison of the smoke stratification results with the filed simulation results. Results show that the three improved methods can effectively determine the location of the three-layer zone model's interface, and they have the ability to predict smoke interface for fires with different fire source types and ventilation conditions.  相似文献   

4.
To address the effect of metro train blockage on the critical ventilation velocity in a long tunnel, a series of scenarios were conducted numerically through this study, including different fire sizes (5-10 MW), metro train lengths (80-120 m), and blockage ratios (φ, 0.50, and 0.57). It is known from the numerical results that the metro train length shows a limited effect on the critical ventilation velocity, which is because the longitudinal ventilation has become stable before reaching the fire source to prevent smoke back-layering, and increasing the metro train length only increases the distance of stabilizing the longitudinal ventilation. The blockage ratio shows an obvious influence on the critical ventilation velocity, which is because the presence of the metro train can obviously reduce the flow cross-sectional area of the tunnel. An empirical model is developed as well, while it is known that the critical ventilation velocity increases with the one-third power of dimensionless heat release rate and (1-φ). The research outcomes of this study provide a technical guide for the design of the metro tunnel and the relevant emergency management of fire rescue under fire conditions.  相似文献   

5.
通风方式对化工车间火灾影响的实例分析   总被引:1,自引:1,他引:0  
连煜洪 《广州化工》2011,39(6):196-198
在分析化工企业火灾危险性的基础上,建立了化工车间火灾危险度分析数学模型。根据工程实际,分别对正常工业通风和火灾后事故通风工况进行了火灾危险度计算。计算结果表明事故通风及防排烟系统启动后,能有效的降低车间的火灾危险性等级。研究结果用于指导化工厂通风系统设计及提高消防安全管理水平。  相似文献   

6.
赵波 《河北化工》2013,(6):82-84,87
煤与瓦斯突出矿井和高瓦斯矿井必须建立地面固定抽采瓦斯系统,同时具有煤层瓦斯预抽和采空区瓦斯抽采方式的矿井,根据需要分别建立高、低负压抽采瓦斯系统。为了加强对瓦斯抽采的监测,瓦斯抽采矿井应当配备瓦斯抽采监控系统,实时监控管网参数及设备的开停状态等。通过监测系统可以一目了然的对该地区的抽采参数进行检测,采取有效手段控制抽采量,真正意义上实现了分源抽采、监测监控。  相似文献   

7.
Investigation of smoke bifurcation flow has been receiving more attentions, however, delicate quantitative analyses on different regions of the bifurcation flow have rarely been addressed. In this study, a series of small-scale experiments were conducted to investigate smoke bifurcation flow in longitudinal ventilated tunnels. Results show that when longitudinal ventilation velocity increases to a certain value, the smoke bifurcation phenomenon emerges, and a low-temperature region forms in the center of the tunnel. Similar to the natural conditions, smoke development under relatively strong ventilation can also be subdivided into four regions. With the increase of ventilation velocity, the ceiling impact region, side wall impact region, and convergence region of two smoke streams move further downstream, indicating that the bifurcation phenomenon becomes more evident. A simple model is proposed based on theoretical analysis and experimental phenomenon to predict two characteristic lengths of smoke bifurcation flow: the offset distance of ceiling impact region and the length of low-temperature region. Both characteristic lengths increase with ventilation velocity and can be well correlated with the dimensionless ventilation velocity defined in Equation (2) ( V ). The results of this work could provide references for both tunnel ventilation designers and fire science researchers.  相似文献   

8.
Characteristics of smoke particulates generated from a coal fire in a ventilated model tunnel were investigated by laser optical transmission and by electron microscopy. Average particle diameter and mass concentration of the smoke were determined as a function of the temperature and stoichimoetry of the coal tunnel fire. Smoke particle sizes ranged from 0.2 to 0.9 μm, with larger particle sizes associated with higher smoke concentrations. These coal smoke data are relevant to several aspects of underground mine safety including the development and location of smoke detection instruments, the understanding of the fire (toxic fume) hazard, and the development of new fire protection and control techniques.  相似文献   

9.
Eight free burning and two sprinklered fire tests were performed with electrical cable trays and live digital switch racks in a large enclosure to simulate telecommunications central office (TCO) fires started by electrical overheating. Very‐slow‐growing (non‐flaming), slower‐growing (partially flaming) and low‐intensity‐faster‐growing (flaming) fires releasing gray‐white, gray, and black smoke, respectively, were observed in the tests. Under quiescent conditions present in the unvented enclosure fire tests for cables, very‐slow‐growing fires were detected in about 1452 s, whereas the slower‐growing fires were detected in about 222 s by commercial fire detectors. Under ventilation conditions typical of TCOs, detection times were very similar for the five types of commercial TCOs fire detectors used in the tests. The average detection times for slower‐growing fires (cable fires) and low‐intensity‐faster‐growing fires (digital switch rack fires) were 242±17% and 249±11%s respectively. The TCO procedures to reduce smoke damage from fires (on fire detection, inlet ventilation flow is turned off and exhaust flow is turned on) were found to be beneficial. The extent of smoke damage decreased significantly with an increase in the exhaust flow rate. The chloride ion mass deposition suggested that equipment recovery would be possible in the smoke environment if the cable vapor concentration could be reduced below about 3 g/m3. The metal corrosion rate was found proportional to the 0.6th power of the smoke concentration, similar to that found for the corrosion of metal surfaces exposed to aqueous solutions of HCl and HNO3 and for acid rain with no protective layer at the surface. Sprinkler water was found to wash down the smoke deposits on the surfaces with little indication of corrosion enhancement. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

10.
The determination of toxic components from fire gases is difficult because the environment is hot, reactions are often temperature dependent, and a lot of soot may be produced. Due to the different properties of the gas components, a different time‐consuming procedure for each species has traditionally been used. The use of FTIR (Fourier transform infrared) spectrometers as a continuous monitoring technique overcomes many of the problems in smoke gas analyses. FTIR offers an opportunity to set up a calibration and prediction method for each gas showing a characteristic spectral band in the infrared region of the spectrum. The objective of the SAFIR project was to further develop the FTIR gas analysis of smoke gases to be an applicable and reliable method for the determination of toxic components in combustion gases related to fire test conditions. The optimum probe design, filter parameters and the most suitable sampling lines in terms of flow rate, diameter, construction material and operating temperature have been specified. In the large scale, special concern was given to the probe design and the effects of the probe location as well as practical considerations of the sampling line length. Quantitative calibration and prediction methods have been constructed for different components present in smoke gases. Recommendations on how to deal with interferents, non‐linearities and outliers have been provided and a verification method for the spectrometer for unexpected variations and for the different models have been described. FTIR measurement procedures in different fire test scenarios have been studied using the recommendations of this project for measurement techniques and analysis and an interlaboratory trial of the FTIR technique in smoke gas analysis was carried out to define the repeatability and reproducibility of the method in connection with a small scale fire test method, the cone calorimeter. Copyright © 2000 John Wiley & Sons Ltd.  相似文献   

11.
冯同竹 《河北化工》2014,(4):123-124
针对显德汪矿1采区9号煤区域小煤矿破坏严重,受CO等有毒有害气体威胁的情况,通过采取三相泡沫注浆、喷洒阻化剂、构筑均压通风系统、安装束管监控系统、喷涂堵漏等一系列综合防灭火技术的研究与应用,有效防止了灾害的发生,保证了该区域工作面的安全采掘,取得了明显效果,对同类条件下的矿井防火具有一定的指导作用。  相似文献   

12.
Countries in the EU are in the process of changing over to a harmonized reaction‐to‐fire classification based on the Construction Products Directive (CPD, 89/106/EC) relating to construction products. It aims to remove technical barriers to trade arising from national laws and regulations, thus enabling the creation of a single European market in construction products. To scrutinize scenario‐dependent effects on burning characteristics, representative building products have been tested using alternative test methods simulating more or less identical fire stages. The test methods were the SBI test and ISO 5658‐4. Comparison of the methods also allowed evaluation with regard to the valid risk assessment of the classification system to be expected. A correlation between different test procedures may be expected as far as the main fire parameters are concerned. The quantitative generation of smoke is, however, primarily a function of the burning rate. Qualitatively smoke density depends on the decomposition conditions — temperature and ventilation — so the time during which a product is involved in the fire is essential for the assessment of smoke density. To quantify the relevant parameters, systematic investigations were made with beech using test procedures ASTM E 662 and DIN 53436/7. Copyright © 2000 John Wiley & Sons, Ltd.  相似文献   

13.
In more and more tunnels, natural ventilation mode with vertical shafts has been gradually employed. However, there are few studies investigating the influences of fire and shaft positions on natural ventilation performance currently. Therefore, this study investigated the effects of the transverse distance from fire source to tunnel sidewall, the longitudinal distance from fire source to shaft, and the transverse distance from shaft to sidewall on natural ventilation effectiveness in a tunnel fire by using Fire Dynamics Simulator. The typical characteristic parameters of smoke, such as mass flow rate, temperature distribution, and velocity vector were analyzed; besides, the phenomenon of plug‐holing was discussed. The results have shown that the mass flow rate of gas exhausted by the shaft decreases slightly with the increase of longitudinal distance from fire source to shaft. When the longitudinal distance from fire source to shaft is constant, changing the transverse distance from shaft to sidewall will have a more obvious effect on the effectiveness of exhausting smoke than changing the transverse distance from fire source to sidewall; in addition, the phenomenon of plug‐holing is more serious when the shaft is close to the sidewall.  相似文献   

14.
This study investigated the efficacy of the full transverse exhaust method for smoke extraction in tunnel fires. It examines factors such as the number and layout of air supply and exhaust outlets, analyzing their impact on smoke spread, tunnel temperature, visibility, and airflow. The results demonstrate that the full transverse exhaust method effectively controls smoke emissions in raised highway tunnels. It limits smoke spread, reduces tunnel temperature, and effectively controls the fire-affected area. The number and layout of outlets significantly influence smoke dispersion, with fewer exhaust outlets providing better smoke control and optimizing the tunnel environment. However, insufficient outlets disrupt gas flow stability. The position of exhaust outlets affects smoke distribution, and caution is advised to prevent directing fresh air flow toward the fire. Opening an equal number of exhaust outlets on one side of the fire source yields superior smoke extraction results, reducing tunnel ceiling temperatures and minimizing risks to personnel and structures. Though stabilization may take longer, this configuration proves advantageous. The study offers valuable insights and practical guidelines for implementing the full transverse smoke control method in real-world scenarios.  相似文献   

15.
Fei Tang  Yuantao Zhu  Lei Chen 《火与材料》2020,44(7):1004-1012
Smoke is the main cause of death in tunnel fires. It is one of the important measures to maintain smoke stratification in the early stage of tunnel fire. This article focused on experimentally studying the combined effect of lateral concentrated smoke extraction and longitudinal ventilation on the smoke stratification, which never be revealed before. The velocity of the smoke layer and air layer, vertical temperature distribution, and the flow patterns of the smoke were measured. It was found that the longitudinal ventilation and lateral concentrated smoke extraction would affect the flow of the smoke and change the shear velocity between the smoke layer and air layer, then, the patterns of the smoke layer will be affected. And the flow patterns with Froude (Fr) number can be classified into three categories: (a)Fr < 0.6 , with stable smoke stratification; (b) 0.6 < Fr < 0.85 , with a stable smoke stratification but the blurring interface; and (c) Fr > 0.85 , the smoke layer is completely unstable. The result can provide a reference for ventilation design of immersed tube tunnels.  相似文献   

16.
W. K. Chow 《火与材料》1995,19(3):101-108
Performance of three fire zone models BR12, CCFM.VENTS and CFAST in simulating forced ventilation fires with low heat release and high ventilation rates were studied experimentally. A fire chamber of length 4.0 m, width 3.0 m height 2.8 m with adjustable ventilation rates was used. Burning tests were carried out with wood cribs and methanol to study the preflashover stage of a compartmental fire and the effect of ventilation. The mass loss rate of fuel, temperature distribution of the compartment and the air intake rate were measured. The heat release rates of the fuel were calculated from the measured mass loss rate. The smoke temperature was used as the validation parameter. A scoring system is proposed to compare the results predicted by the three models. An empirical expression for calculating the smoke temperature is assessed. Lastly, the Computational Fluid Dynamics technique is also used for comparing the simulated fire environment.  相似文献   

17.
This study investigated the influence of the longitudinal airflow on the smoke propagation in a tunnel by large-eddy simulation, which is now widely applied to study the turbulent flow. The smoke movement characteristics were studied in detail, with varying the longitudinal airflow in the tunnel. Six fire scenarios have been simulated with Fire Dynamics Simulator (FDS) and the results of the longitudinal distribution of CO concentration, temperature distribution, interface height, stratification, and the efficiency of smoke extraction in the tunnel have been analyzed to evaluate the different fire cases. FDS predicted a CO concentration distribution compared to calculated values using the Hu model. Furthermore, the predicted maximum smoke temperatures are compared to those given by the Kurioka model. A reasonably good agreement has been obtained for both models. The obtained results showed that the increase of the forced airflow velocity has for results a loss of stratification and significant decrease in the efficiency of extraction.  相似文献   

18.
The critical ventilation velocity is almost the most well‐investigated fire phenomenon in the tunnel fire research field whereas previous studies have always investigated it when the fire source is distant from the downstream tunnel exit. Fortunately, a recent study provided a set of data on the critical ventilation velocity for tunnel fires occurring near tunnel exits by small‐scaled experiments, nevertheless, with a lack of further analysis. To demonstrate the relationship of the critical ventilation velocity and the distance between the fire and tunnel exit more explicitly and detailedly, a quantitative and graphical study was carried out and a correlation was presented in this paper. Inspired by this, a set of small‐scaled experiments were carried out to investigate the influence of different longitudinal fire locations on maximum smoke temperature under the tunnel ceiling. Results show that unlike the critical ventilation velocity, the maximum smoke temperature was not obviously affected by longitudinal fire location. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
Passenger vehicle fires present a significant fire hazard in enclosed car parks. Accordingly, this hazard is often used as a design fire scenario for the application of fire protection systems. Specific fire protection standards, like NFPA 88A:2019 and NFPA 502:2020 in the United States (US) or BS 7346-7:2013, NBN 21-208-2:2014, VDI 6019-1:2006, NEN 6098:2010 and ITB 493:2015 in Europe, provide varying requirements for car park fire protection. Car parks fire strategies, especially when smoke control systems are used, often make use of performance-based methods, in which fire growth (ie, heat release rate [HRR]) plays a fundamental role. The chosen HRR can influence the specification of car park construction and on smoke control system calculations. This article presents a review of 44 full-scale car fire tests together with Polish and British passenger car fire statistics from the last 8 years. Based on the collected data and the averaged tests, HRR values provided in this article could assist local authorities and stakeholders determine optimal fire safety design criteria for car parks.  相似文献   

20.
The combustion characteristics of methanol‐gasoline blends pool fires were studied in a series of full‐scale tunnel experiments conducted with different methanol and gasoline blends. The parameters were measured including the mass loss rate, the pool surface temperature, the fire plume centerline temperature, the ceiling temperature, the smoke layer temperature profile, the flame height, and the smoke layer interface height. The gasoline components were analyzed by GC‐MS. The effects of azeotropism on the combustion characteristics of the different blends were discussed. On the basis of the results of the fire plume centerline temperature, the ceiling temperature, and the flame height, it shows that the tunnel fire regime gradually switches from fuel controlled to ventilation controlled with increasing gasoline fractions in the blends. The fire plume can be divided into 3 regions by the fire plume centerline temperature for the different blends. The N‐percentage rule to determine the smoke layer interface height is found to be applicable for tunnel fires with different blends for N = 26.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏