1.
A brief review of the fate of micropollutants in membrane-based wastewater treatment due to sorption, stripping, biological degradation/transformation and membrane separation is discussed, to give an overview of these technologies due to the growing importance for water reuse purposes. Compared with conventional activated sludge treatment (CAS) micropollutant removal in membrane bioreactor (MBR) is slightly improved due to complete suspended solids removal and increased sludge age. For discharge to sensitive receiving waters advanced treatment, such as post-ozonation or activated carbon adsorption, is recommended. In water reuse plants nanofiltration (NF) and reverse osmosis (RO) efficiently reject micropollutants due to size exclusions as well as electrostatic and hydrophobic effects reaching potable quality. To remove micropollutants fully, additionally post-ozone or the addition of powdered activated carbon (PAC) have to be applied, which in parallel also reduce NDMA precursors. The concentrate has to be treated if disposed to sensitive receiving waters due to its high micropollutant concentration and ecotoxicity potential. The present review summarizes principles and capabilities for the most important membrane-based applications for wastewater treatment, i.e. porous membranes in MBRs (micro- or ultrafiltration) and dense membrane applications (NF and RO) for water reuse.  相似文献   

2.
Membrane bio-reactor for advanced textile wastewater treatment and reuse.   总被引:1,自引:0,他引:1  
Textile wastewater contains slowly- or non-biodegradable organic substances whose removal or transformation calls for advanced tertiary treatments downstream Activated Sludge Treatment Plants (ASTP). This work is focused on the treatment of textile industry wastewater using Membrane Bio-reactor (MBR) technology. An experimental activity was carried out at the Baciacavallo Wastewater Treatment Plant (WWTP) (Prato, Italy) to verify the efficiency of a pilot-scale MBR for the treatment of municipal wastewater, in which textile industry wastewater predominates. In the Baciacavallo WWTP the biological section is followed by a coagulation-flocculation treatment and ozonation. During the 5 months experimental period, the pilot-scale MBR proved to be very effective for wastewater reclamation. On average, removal efficiency of the pilot plant (93% for COD, 96% for ammonium and 99% for total suspended solids) was higher than the WWTP ones. Color was removed as in the WWTP. Anionic surf actants removal of pilot plant and WWTP were very similar (92.5 and 93.3% respectively), while the non-ionic surfactants removal was higher in the pilot plant (99.2 vs. 97.1). In conclusion the MBR technology demonstrated to be effective for textile wastewater reclamation, leading both to an improvement of pollutants removal and to a draw-plate simplification.  相似文献   

3.
This study examined the reuse potential of the effluents discharged from several unified wastewater treatment plants (WWTPs) of industrial parks in Taiwan, with designed capacity exceeding 10,000 CMD. Parameters were selected based on the relevant reuse purposes. The "potential recycling percentage", R of the WWTP effluent was defined as the maximal percentage of pure water extractable by the "ideal reverse osmosis module" while the RO retentate still met local effluent standards and required no treatment. The analytical results demonstrated that the WWTP effluents had potential for recycling. A pilot plant was installed in one of the WWTPs. The treatment process included a sand filter, an ultrafiltration unit (UF) and a reverse osmosis module (RO). Results of this study demonstrated that the production quantity and quality are stable and appropriate for various purposes, including both industrial and domestic applications.  相似文献   

4.
The paper expresses an attempt to tackle the problem due to the presence of micropollutants in wastewater which may be able to disrupt the endocrine system of some organisms. These kinds of compounds are ubiquitously present in municipal wastewater treatment plant (WWTP) effluents. The aim of this paper is to compare the fate of the alkylphenols-APs (4-(tert-octyl)) phenol, t-nonylphenol and 4-p-nonylphenol and the hormones (estrone, 17β-estradiol and 17α-ethinylestradiol) in a submerged anaerobic membrane bioreactor (SAMBR) pilot plant and in a conventional activated sludge wastewater treatment plant (CTP). The obtained results are also compared with the results obtained in a previous study carried out in an aerobic MBR pilot plant. The results showed that the APs soluble concentrations in the SAMBR effluent were always significantly higher than the CTP ones. Moreover, the analyses of the suspended fraction revealed that the AP concentrations in the SAMBR reactor were usually higher than in the CTP reactor, indicating that under anaerobic conditions the APs were accumulated in the digested sludge. The aerobic conditions maintained both in the CTP system and in the aerobic MBR favoured the APs and hormones degradation, and gave rise to lower concentrations in the effluent and in the reactor of these systems. Furthermore, the results also indicated that the degradation of APs under aerobic conditions was enhanced working at high solid retention time (SRT) and hydraulic retention time (HRT) values.  相似文献   

5.
Textile industries carry out several fiber treatments using variable quantities of water, from five to forty times the fiber weight, and consequently generate large volumes of wastewater to be disposed of. Membrane Bio-reactors (MBRs) combine membrane technology with biological reactors for the treatment of wastewater: micro or ultrafiltration membranes are used for solid-liquid separation replacing the secondary settling of the traditional activated sludge system. This paper deals with the possibility of realizing a new section of one existing WWTP (activated sludge + clariflocculation + ozonation) for the treatment of treating textile wastewater to be recycled, equipped with an MBR (76 l/s as design capacity) and running in parallel with the existing one. During a 4-month experimental period, a pilot-scale MBR proved to be very effective for wastewater reclamation. On average, removal efficiency of the pilot plant (93% for COD, and over 99% for total suspended solids) was higher than the WWTP ones. Color was removed as in the WWTP. Anionic surfactants removal of pilot plant was lower than that of the WWTP (90.5 and 93.2% respectively), while the BiAS removal was higher in the pilot plant (98.2 vs. 97.1). At the end cost analysis of the proposed upgrade is reported.  相似文献   

6.
Pharmaceuticals are continually being introduced into the influent of municipal wastewater treatment plants (WWTPs). Developing a better understanding of pharmaceutical removal mechanisms within the different treatment processes is vital in preventing downstream contamination of our water resources. In this study, ibuprofen, a popular over-the-counter pain reliever, was monitored by taking wastewater samples throughout the City of Guelph municipal WWTP. Greater than 95% of ibuprofen was found to be removed in the aeration tank, with aerobic biodegradation being the dominant mechanism. For comparison, first-order kinetics were used to quantify ibuprofen biodegradation in a conventional WWTP aeration tank and in a membrane bioreactor (MBR) pilot plant. The rate constants, k biol, for the conventional tank and the MBR were determined to be (-6.8+/-3.3) L/g SS*d and (-8.4+/-4.0) L/g SS*d, respectively. These two rate constants were found to be statistically similar. Preliminary study of a biological nutrient removal pilot system also suggests that ibuprofen can be anaerobically degraded.  相似文献   

7.
Despite the well-known potential and performance of combined biological and ozonation processes for wastewater treatment, only few full-scale applications are published. Beside the synergistic effects of such process combination, which lead to oxidation of recalcitrant and inhibitory compounds or intermediates by enhancement of their biodegradability, the key for raising applicability is the improvement of the ozonation efficiency. An overview about the history and progress of full-scale applications, which deals with combined ozonation and biological treatment is given. Recently more than 40 applications exist, but many of them are not published. Therefore, a couple of selected not yet published applications have been mentioned in this paper. Landfill leachate and industrial wastewater treatment were mostly applicated, while treatment of municial wastewater treatment plant (WWTP) effluents are of increasing interest due to several advantages such as disinfection, decolourisation and removal of persistent dissolved organic carbon (DOC) for water re-use and groundwater recharge.  相似文献   

8.
Water shortage has become an emerging environmental issue. Reclamation of the effluent from municipal wastewater treatment plant (WWTP) is feasible for meeting the growth of water requirement from industries. In this study, the results of a pilot-plant setting in Futian wastewater treatment plant (Taichung, Taiwan) were presented. Two processes, sand filter - ultrafiltration - reverse osmosis (SF-UF-RO) and sand filter - electrodialysis reversal (SF-EDR), were operated in parallel to evaluate their stability and filtrate quality. It has been noticed that EDR could accept inflow with worse quality and thus required less pretreatment compared with RO. During the operation, EDR required more frequent chemical cleaning (every 3 weeks) than RO did (every 3 months). For the filtrate quality, the desalination efficiency of SF-EDR ranged from 75 to 80% in continuous operation mode, while the conductivity ranged from 100 to 120 μS/cm, with turbidity at 0.8 NTU and total organic carbon at 1.3 mg/L. SF-EDR was less efficient in desalinating the multivalent ions than SF-UF-RO was. However for the monovalent ions, the performances of the two processes were similar to each other. Noticeably, total trihalomethanes in SF-EDR filtrate was lower than that of SF-UF-RO, probably because the polarization effects formed on the concentrated side of the EDR membrane were not significant. At the end of this study, cost analysis was also conducted to compare the capital requirement of building a full-scale wastewater reclamation plant using the two processes. The results showed that using SF-EDR may cost less than using SF-UF-RO, if the users were to accept the filtrate quality of SF-EDR.  相似文献   

9.
Several studies show that a more detailed characterisation of the particulate matter in municipal wastewater gives a better understanding and prediction of removal efficiencies of physical-chemical treatment techniques and the application of optimal chemical dosages. Such a characterisation should include the distribution of contaminants over various particle sizes. This article describes a method and results of experimental and full-scale investigations, conducted to determine how contaminants in wastewater are distributed over different particle sizes. For this purpose, particle size fractionations of wastewater influents originating from more than thirteen WWTP were carried out. One of these fractionations (WWTP Venray) is shown and interpreted in this article. First, the wastewaters were fractionated into 5 to 6 particle fractions (45, 5.0, 1.0/1.2, 0.45 and 0.1 microm) after which the fractions were analyzed for various water quality parameters like organic components, nutrients, salts, solids and turbidity. Based on the results the effects of removal of the different size fractions on design of the biological treatment and energy balance of a wastewater treatment plant can be assessed. The method also indicates whether a certain wastewater is efficiently treatable with physical-chemical pre-treatment methods. It is concluded wastewater fractionation on particle size is very useful, but that wastewater characteristics and particle size distributions should not be generalised, but have to be interpreted as indications for a certain average wastewater composition. To give more insight into the distribution of contaminants over particle size and the particle removal potential, a specific wastewater fractionation has to be carried out per WWTP.  相似文献   

10.
Influent--effluent monitoring by comprehensive chemical analyses was conducted at the Avedoere wastewater treatment plant (WWTP) during 2002. In one programme, the same samples were tested for algal toxicity by the ISO 8692 method. Based on evaluation of 17 hazardous substances (including 7 heavy metals), there was a quite good agreement between calculated and measured toxic units. In another programme, influent--effluent monitoring for 11 pharmaceuticals and specific hormones showed high removal rates, except for sulphamethizol and furosemide. High removal is probably due to WWTP operation with long SRTs. Effluent biomonitoring of freshwater mussels showed only bioaccumulation for: diethylphthalate, LAS, EOX as well as Cr and Ni. Surprisingly, no bioaccumulation could be observed for 100 other specific organic compounds and 8 other heavy metals (including Hg, Cd and Pb).  相似文献   

11.
This study presents a good example for the tertiary treatment of biologically treated piggery wastewater using vibratory shear enhanced RO membrane (VSEP RO). Through a simple process combination, utilizing Bioceramic SBR(BCS) and VSEP RO, at Gimhae plant livestock wastewater is treated excellently to meet the strict effluent standards. Application of RO membrane directly to the biologically treated effluent has been successful without any pretreatment to reduce high suspended solids. The combination of VESP UF followed by RO filtration processes produced a higher recovery rate in the 3-week pilot test.  相似文献   

12.
A full-scale plant of an MBR system treating livestock wastewater has shown impressive results. The Cheorwon County Environmental Authorities adopted the MBR process with UF membrane for retrofitting the old plant, which removes organic matter, nitrogen and phosphorus at a high level. According to 6 months operation data, BOD and SS removal were about 99.9% and COD(Mn), TN and TP removal were 92.0%, 98.3% and 82.7%, respectively. It is considered that the temperature at the bioreactor has to be controlled to be below 40 degrees C so as to ensure sufficient nitrification. It appeared that the MBR system is competitive with other conventional technologies for treatment of livestock wastewater such as piggery waste.  相似文献   

13.
Discharge waters from activated sludge processes in the pulp and paper industry and from a municipal wastewater treatment plant were filtered with various nanofiltration (NF) and low pressure reverse osmosis (RO) membranes. The purpose was to study flux, retention, and permeate quality after membrane filtration by using a high shear (CR-250/2) filter. The suitability of the achieved permeates for reuse at the industrial site is also discussed. The NF permeate was practically free from colour and organic compounds but contained significant amount of inorganic compounds e.g. chloride ions, especially when a high amount of sulphate containing discharge waters were filtered, in which case a low pressure RO membrane was needed to successfully remove monovalent anions. Organic compounds were almost completely retained by NF and RO membranes and organic carbon in the permeate was less than 10 mg/dm3 on average. The achieved permeate can easily be reused in paper production. Nanofiltration has a significantly higher flux and also a lower fouling tendency than reverse osmosis but it passes through monovalent ions when there is a high sulphate concentration in the water. Therefore, RO might be needed in such cases to produce excellent process water.  相似文献   

14.
This paper presents the results of the long-term operation and monitoring of membrane fouling at several full-scale MF/RO water recycling facilities operated by Agbar in Spain. It was demonstrated that membranes give very reliable treatment enabling the production of high-grade recycled water, well disinfected and with the removal of all priority substances. The high organic and salt concentrations of raw wastewater combined to extremely high variations justified the implementation of sand filtration to protect MF/RO membranes. Membrane autopsy was used to better understand the predominant fouling mechanisms and optimise down-stream operation and membrane cleaning strategy. The main membrane pathologies are described with recommendation of an adequate cleaning strategy.  相似文献   

15.
Membrane bioreactor (MBR) technology is a very reliable and extensively tested solution for biological wastewater treatment. Nowadays, separate treatment of highly polluted wastewater streams especially from hospitals and other health care facilities is currently under investigation worldwide. In this context, the MBR technology will play a decisive role because an effluent widely cleaned up from solids and nutrients is absolutely mandatory for a subsequent further elimination of organic trace pollutants. Taking hospital wastewater as an example, the aim of this study was to investigate to what extent MBR technology is an adequate 'pre-treatment' solution for further elimination of trace pollutants. Therefore, we investigated - within a 2-year period - the performance of a full-scale hospital wastewater treatment plant (WWTP) equipped with a MBR by referring to conventional chemical and microbiological standard parameters. Furthermore, we measured the energy consumption and tested different operating conditions. According to our findings the MBR treatment of the hospital wastewater was highly efficient in terms of the removal of solids and nutrients. Finally, we did not observe any major adverse effects on the operation and performance of the MBR system which potentially could derive from the composition of the hospital wastewater. In total, the present study proved that MBR technology is a very efficient and reliable treatment approach for the treatment of highly polluted wastewater from hospitals and can be recommended as a suitable pre-treatment solution for further trace pollutant removal.  相似文献   

16.
Micropollutants as pharmaceutical active compounds (PhACs), residuals of personal care products or endocrine disrupting chemicals are of increasing interest in water pollution control. In this context the removal efficiencies of sewage treatment plants (STPs) are of importance, as their effluents are important point sources for the release of those substances into the aquatic environment. Activated sludge based wastewater treatment is the worldwide prevalently used treatment technique. In conventional plants the separation of treated wastewater and sludge occurs via sedimentation. A new development is the application of membrane technology for this separation step. The studies focus on the influence of the solids retention time (SRT) on the removal efficiency, as the SRT is the most important parameter in the design of STPs. A conventional activated sludge plant (CASP) and a membrane bioreactor (MBR) were operated at different SRTs. The substances selected are the antiepileptic carbamazepine, the analgesics diclofenac and ibuprofen, the lipid regulator bezafibrate, the polycyclic musks tonalide and galaxolide and the contraceptive 17alpha-ethinylestradiole. No significant differences in the removal efficiency were detected. Due to the absence of suspended solids in the MBR effluent, substances with high adsorption potential could be retained to slightly higher amounts.  相似文献   

17.
Design considerations for wastewater treatment by reverse osmosis.   总被引:2,自引:0,他引:2  
Reverse Osmosis is finding increasing use for the treatment of municipal and industrial wastewaters due to the growing demand for high quality water in large urban areas. The growing success of membranes in this application is related to improved process designs and improved membrane products. Key factors which have been determined to result in successful operation of large-scale plants will be discussed. Factors which play a key role in the use of RO membranes include ultra or microfiltration pretreatment, low fouling membranes, flux rate, recovery and control of fouling and scaling. In particular, high flux rates can be used when UF or MF pretreatment is used. These technologies remove most of the suspended particles that would normally cause heavy fouling of lead elements. Typically, fluxes in the range of 17-21 lmh lead to cleaning frequencies in the range of 3-4 months. By combining the use of membrane pretreatment and chloramination of the feed water through chlorine addition, two of the primary sources of RO membrane fouling can be controlled. The use of chloramine has become a proven means to control biofouling in a membrane for wastewater applications. The other significant problems for RO membranes result from organics fouling by dissolved organics and scaling due to saturation of marginally soluble salts. The former can be a significant problem for membranes, due to the strong attraction forces. To some extent, these can be mitigated by making the membrane surface more hydrophilic or changing the charge of the membrane surface. To minimize fouling, many plants are turning to low fouling membranes. Extensive studies have demonstrated that the membrane surface is hydrophilic, neutrally charged over a broad pH range, and more resistant to organic adsorption. Also, an analysis of the potential scaling issues will be reviewed. In particular, calcium phosphate has been found to be one of the key scalants that will limit RO system recovery rate. Calcium phosphate concentrations can reach high values in many wastewaters, and scaling of this compound is not often modeled in most RO projection software. Various process options will be presented to evaluate the most economic means of avoiding phosphate scaling. Finally, data from major RO wastewater treatment plants will be presented to show how the RO membranes operate under actual conditions, utilizing many of these design features. Long-term data from the 2.6 mgd Bedok demonstration Plant demonstrate that the RO membranes operate consistently on wastewater. Experiences from the 8.5 mgd (32,000 m3/day) Bedok and 10.5 mgd (40,000 m3/day) Kranji plants will also be presented. These large plants started operation in the fall of 2002 and have demonstrated an effective means to reclaim high quality water from difficult source waters, such as municipal wastewaters.  相似文献   

18.
Life Cycle Assessment was used to evaluate environmental impacts associated to a full-scale wastewater treatment plant (WWTP) in Barcelona Metropolitan Area, with a treatment capacity of 2 million population equivalent, focussing on energy aspects and resources consumption. The wastewater line includes conventional pre-treatment, primary settler, activated sludge with nitrogen removal, and tertiary treatment; and the sludge line consists of thickening, anaerobic digestion, cogeneration, dewatering and thermal drying. Real site data were preferably included in the inventory. Environmental impacts of the resulting impact categories were determined by the CLM 2 baseline method. According to the results, the combustion of natural gas in the cogeneration engine is responsible for the main impact on Climate Change and Depletion of Abiotic Resources, while the combustion of biogas in the cogeneration unit accounts for a minor part. The results suggest that the environmental performance of the WWTP would be enhanced by increasing biogas production through improved anaerobic digestion of sewage sludge.  相似文献   

19.
Installing membranes for solid-liquid separation into biological nutrient removal (BNR) activated sludge (AS) systems makes a profound difference not only to the design of the membrane bio-reactor (MBR) BNR system itself, but also to the design approach for the whole wastewater treatment plant (WWTP). In multi-zone BNR systems with membranes in the aerobic reactor and fixed volumes for the anaerobic, anoxic and aerobic zones (i.e. fixed volume fractions), the mass fractions can be controlled (within a range) with the inter-reactor recycle ratios. This zone mass fraction flexibility is a significant advantage of MBR BNR systems over BNR systems with secondary settling tanks (SSTs), because it allows changing the mass fractions to optimise biological N and P removal in conformity with influent wastewater characteristics and the effluent N and P concentrations required. For PWWF/ADWF ratios (fq) in the upper range (fq approximately 2.0), aerobic mass fractions in the lower range (f(maer) < 0.60) and high (usually raw) wastewater strengths, the indicated mode of operation of MBR BNR systems is as extended aeration WWTPs (no primary settling and long sludge age). However, the volume reduction compared with equivalent BNR systems with SSTs will not be large (40-60%), but the cost of the membranes can be offset against sludge thickening and stabilisation costs. Moving from a flow unbalanced raw wastewater system to a flow balanced (fq = 1) low (usually settled) wastewater strength system can double the ADWF capacity of the biological reactor, but the design approach of the WWTP changes away from extended aeration to include primary sludge stabilisation. The cost of primary sludge treatment then has to be offset against the savings of the increased WWTP capacity.  相似文献   

20.
The occurrence of filamentous bacteria was investigated in 15 French pulp and paper activated sludge wastewater treatment plant (WWTP). Large filamentous populations were present in most of the plants. Identification carried out with conventional methods based on morphological features and staining techniques showed that the four main filamentous bacteria encountered in these industrial WWTP and responsible for bulking belong to the genera Thiothrix sp., Type 021 N, Haliscomenobacter hydrossis and Type 0092. During two years a specific survey was performed for three of these WWTP showing recurrent bulking phenomena. Data from WWTP performance, chemical data and filaments characterization were compared to correlate the presence of specific filaments with process operating conditions.  相似文献   