首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 140 毫秒
1.
Removal of denitrifying phosphorus was verified in a laboratory anaerobic/anoxic sequencing batch reactor (A/A SBR). The results obtained demonstrated that the anaerobic/anoxic strategy can enrich the growth of denitrifying phosphorus removing bacteria (DPB) and take up phosphate under anoxic condition by using nitrate as the electron acceptor. The phosphorus removal efficiency was higher than 90% and the effluent phosphate concentration was lower than lmg·L-1 after the A/A SBR was operated in a steady-state. When the chemical oxygen demand(COD) of influent was lower than 180mg·L-1, the more COD in the influent was, the higher efficiency of phosphorus removal could be attained under anoxic condition. However, simultaneous presence of carbon and nitrate would be detrimental to denitrifying phosphorus removal. Result of influence of sludge retention time (SRT) on denitrifying phosphorus removal suggested that the decrease of SRT caused a washout of DPB and consequently the enhanced biological phosphorus  相似文献   

2.
厌氧/缺氧SBR反硝化除磷过程的研究   总被引:1,自引:0,他引:1       下载免费PDF全文
Removal of denitrifying phosphorus was verified in a laboratory anaerobic/anoxic sequencing batch reactor (A/A SBR). The results obtained demonstrated that the anaerobic/anoxic strategy can enrich the growth of denitrifying phosphorus removing bacteria (DPB) and take up phosphate under anoxic condition by using nitrate as the electron acceptor. The phosphorus removal efficiency was higher than 90% and the effluent phosphate concentration was lower than 1mg·L^-1 after the A/A SBR was operated in a steady-state. When the chemical oxygen demand(COD) of influent was lower than 180mg·L^-1, the more COD in the influent was, the higher efficiency of phosphorus removal could be attained under anoxic condition. However, simultaneous presence of carbon and nitrate would be detrimental to denitrifying phosphorus removal. Result of influence of sludge retention time (SRT) on denitrifying phosphorus removal suggested that the decrease of SRT caused a washout of DPB and consequently the enhanced biological phosphorus removal decreased with 8 days SRT. When the SRT was restored to 16 days, however, the efficiency of phosphorus removal was higher than 90%.  相似文献   

3.
一种利用脱氮硫杆菌的同步脱硫反硝化新工艺研究   总被引:4,自引:0,他引:4  
Thiobacillus denitrificans, a kind of autotrophic facultative bacteria, can oxidize sulfide into elemental sulfur or sulfate when nitrate was adopted as its electron accepter and carbon dioxide as its carbon resource under anoxic or anaerobic environment. In this way, nitrate is converted into nitrogen. In addition, ThiobaciWus denitrificans can accumulate sulfur extracellularly. In this study, in a process of simultaneous desulfurization and denitrification, a strain of Thiobacillus denitriificans is employed as sulfur-producer in the treatment of wastewater containing sulfide and nitrate. The key factors affecting this process are investigated through batch tests. The experimental results indicate that the sulfide concentration and the ratio of sulfide to nitrate (S2-/NO3-) in the influent are the key factors, and their suitable values are suggested to be 5/3 and no more than 300mg·L-1, respectively, in order to achieve high conversion of sulfur.  相似文献   

4.
A pilot-scale modified carbon source division anaerobic anoxic oxic (AAO) process with pre-concentration of returned activated sludge (RAS) was proposed in this study for the enhanced biological nutrient removal (BNR) of municipal wastewater with limited carbon source. The influent carbon source was fed in step while a novel RAS pre-concentration tank was adopted to improve BNR efficiency, and the effects of an influent carbon source distribution ratio and a RAS pre-concentration ratio were investigated. The results show that the removal efficiency of TN is mainly influenced by the carbon source distribution ratio while the TP removal relies on the RAS pre-concentration ratio. The optimum carbon source distribution ratio and RAS pre-concentration ratio are 60%and 50%, respectively, with an inner recycling ratio of 100%under the optimum steady operation of pilot test, reaching an average effluent TN concentration of 9.8 mg·L?1 with a removal efficiency of 63%and an average TP removal efficiency of 94%. The mechanism of nutrient removal is discussed and the kinetics is analyzed. The results reveal that the optimal carbon source distribution ratio provides sufficient denitrifying carbon source to each anoxic phase, reducing nitrate accumulation while the RAS pre-concentration ratio improves the condition of anaerobic zone to ensure the phosphorus release due to less nitrate in the returned sludge. Therefore, nitrifying bacteria, denitrifying bacteria and phosphorus accumulation organisms play an important role under the optimum condition, enhancing the performance of nutrient removal in this test.  相似文献   

5.
In order to enhance phosphorus removal in traditional step-feed anoxic/oxic nitrogen removal process,a modified pilot-scale step-feed anaerobic/anoxic/oxic (SFA2/O) system was developed,which combined a reactor similar to UCT-type configuration and two-stage anoxic/oxic process.The simultaneous nitrogen and phosphorus removal capacities and the potential of denitrifying phosphorus removal,in particular,were investigated with four different feeding patterns using real municipal wastewater.The results showed that the feeding ratios(Q1)in the first stage determined the nutrient removal performance in the SFA2/O system.The average phosphorus removal efficiency increased from 19.17% to 96.25% as Q1 was gradually increased from run 1 to run 4,but the nitrogen removal efficiency exhibited a different tendency,which attained a maximum 73.61% in run 3 and then decreased to 59.62% in run 4.As a compromise between nitrogen and phosphorus removal,run 3 (Q1=0.45Qtotal) was identified as the optimal and stable case with the maximum anoxic phosphorus uptake rate of 1.58mg·(g MLSS)-1·h-1.The results of batch tests showed that ratio of the anoxic phosphate uptake capacity to the aerobic phosphate uptake capacity increased from 11.96% to 36.85% with the optimal influent feeding ratio to the system in run 3,which demonstrated that the denitrifying polyP accumulating organisms could be accumulated and contributed more to the total phosphorus removal by optimizing the inflow ratio distribution.However,the nitrate recirculation to anoxic zone and influent feeding ratios should be carefully controlled for carbon source saving.  相似文献   

6.
A lab-scale anaerobic-anoxic-oxic (A^2O) process used to treat a synthetic brewage wastewater was investigated. The objectives of the study were to identify the existence of denitrifying phosphorus removing bacteria (DPB), evaluate the contribution of DPB to biological nutrient removal and enhance the denitrifying phosphorus removal in A^2O bioreactors. Sludge analysis confirmed that the average anoxic P uptake accounted for approximately 70% the total amount of P uptake, and the ratio of anoxic P uptake rate to aerobic P uptake rate was 69%. In addition, nitrate concentration in the anoxic phase and different organic substrate introduced into the anaerobic phase had significant effect on the anoxic P uptake. Compared with conventional A^2O processes, good removal efficiencies of COD, phosphorus, ammonia and total nitrogen (92.3%, 95.5%, 96% and 79.5%, respectively) could be achieved in the anoxic P uptake system, and aeration energy consumption was saved 25%. By controlling the nitrate recirculation flow in the anoxic zone, anoxic P uptake could be enhanced, which solved the competition for organic substrates among poly-P organisms and denitrifiers successfully under the COD limiting conditions. Therefore, in wastewater treatment plants the control system should be applied according to the practical situation to optimize the operation.  相似文献   

7.
A pilot-scale,pre-anoxic-anaerobic oxidation ditch was used in this study to treat municipal wastewater with limited carbon source.A novel return activated sludge(RAS) pre-concentration tank was adopted for improv-ing the phosphorus removal efficiency and the effects of RAS pre-concentration ratio were studied.Under the opti-mal operational condition,the suspended total phosphorus(STP) and the total phosphorus(TP) removal efficiencies were around 58.9% and 63.9% respectively and the effluent-P was lower than 0.8 mg·L-1.The reason is that with the optimal RAS pre-concentration ratio,nitrate is completely removed with endogenous carbon source and the secondary phosphorus release is strictly restrained in the pre-anoxic tank.Therefore,the anaerobic phosphorus release and the carbon source uptake by phosphorus accumulation organisms(PAOs) in the sludge,which are ex-tremely important to the phosphorus removal process,can be fully satisfied.Furthermore,the oxidation-reduction potential is proved to be suitable for controlling the RAS pre-concentration ratio due to influent fluctuation and varied conditions.The novel modified system is also beneficial for PAO accumulation.  相似文献   

8.
The nitrite accumulation in the denitrification process is investigated with sequencing batch reactor (SBR) treating pre-treated landfill leachate in anoxic/anaerobic up-flow anaerobic sludge bed (UASB). Nitrite accumulates obviously at different initial nitrate concentrations (64.9,54.8,49.3 and 29.5 mg•L-1) and low temperatures, and the two break points on the oxidation-reduction potential (ORP) profile indicate the completion of nitrate and nitrite reduction. Usually, the nitrate reduction rate is used as the sole parameter to characterize the denitrification rate, and nitrite is not even measured. For accuracy, the total oxidized nitrogen (nitrate + nitrite) is used as a measure, though details characterizing the process may be overlooked. Additionally, batch tests are conducted to investigate the effects of C/N ratios and types of carbon sources on the nitrite accumulation during the denitrification. It is observed that carbon source is sufficient for the reduction of nitrate to nitrite, but for further reduction of nitrite to nitrogen gas, is deficient when C/N is below the theoretical critical level of 3.75 based on the stoichiometry of denitrification. Five carbon sources used in this work, except for glucose, may cause the nitrite accumulation. From experimental results and cited literature, it is concluded that Alcaligene species may be contained in the SBR activated-sludge system.  相似文献   

9.
曝气生物滤池中含苦味酸废水的COD降解动力学特性   总被引:4,自引:1,他引:3       下载免费PDF全文
An empirical model for COD removal in a biological aerated filter (BAF) in the presence of 2,4,6-trinitrophenol (TNP) was developed, which related effluent COD to influent COD or hydraulic loading rate along the bed height. The overall reaction rate for substrate biodegradation could be described as pseudo first order. The experimental data of COD removal against reactor height were used to calculate the parameters in the empirical model. The COD concentration at different reactor height was expressed as a function of influent COD concentration and hydraulic loading rate, and , respectively, under the experimental condi-tion. The models may be used to predict the COD removal profiles along the reactor height at different hydraulic loading rates and influent COD concentration for design, selection and sizing of BAF.  相似文献   

10.
A novel full scale modified A2O (anoxic/anaerobic/aerobic/pre-anoxic)-membrane bioreactor (MBR) plant combined with the step feed strategy was operated to improve the biological nutrient removal (BNR) from low C/N ratio municipal wastewater in Southern China. Transformation of organic carbon, nitrogen and phosphorus, and membrane fouling were investigated. Experimental results for over four months demonstrated good efficiencies for chemical oxygen demand (COD) and NH4^+-N removal, with average values higher than 84.5%and 98.1%, re-spectively. A relatively higher total nitrogen (TN) removal efficiency (52.1%) was also obtained at low C/N ratio of 3.82, contributed by the configuration modification (anoxic zone before anaerobic zone) and the step feed with a distribution ratio of 1:1. Addition of sodium acetate into the anoxic zone as the external carbon source, with a theoretical amount of 31.3 mg COD per liter in influent, enhanced denitrification and the TN removal efficiency in-creased to 74.9%. Moreover, the total phosphate (TP) removal efficiency increased by 18.0%. It is suggested that the external carbon source is needed to improve the BNR performance in treating low C/N ratio municipal waste-water in the modified A^2O-MBR process.  相似文献   

11.
鹿钦礼  王晓玲 《当代化工》2012,(3):308-311,327
以低C/N比污水为处理对象、基于物料平衡分析,研究了在MUCT工艺中硝化液内循环比与COD降解转化、PHA的代谢、磷的转移以及氮的转化等4个过程的关系。进水COD浓度恒定为(290±10)mg/L,TN浓度恒定为(55±0.5)mg/L,TP浓度恒定为(7.0±0.5)mg/L,改变硝化液内循环比,测定各反应段及出水COD、TN、TP浓度以及污泥中的PHA含量。试验结果表明:厌氧段去除的COD的63%~67%左右转化为PHA,在第二缺氧段和好氧段,PHA被消耗用于吸收污水中的磷,硝化液内循环比对第二缺氧段的消耗量有较明显的影响;硝化液内循环比对磷的释放过程影响较小,是第二缺氧段的吸磷过程的主要影响因素。  相似文献   

12.
流量分配比对改良A/O分段进水脱氮除磷特性的影响   总被引:4,自引:0,他引:4  
采用改良A/O分段进水工艺处理我国南方低浓度、低碳氮比城市生活污水。在进水COD/TN为5.16,HRT为8.7 h,SRT为15 d,MLSS为5.66 g·L-1,污泥回流比为75%,厌氧/缺氧/好氧体积比为4∶8∶10条件下,通过设置6种不同进水流量分配比,控制各好氧段DO为1~1.5 mg·L-1,经过150 d的连续运行,得到系统最佳流量分配比为20%∶35%∶35%∶10%;在此工况下COD、氨氮、总氮、总磷出水水质分别为33.05 mg·L-1、0.58 mg·L-1、9.26 mg·L-1、0.46 mg·L-1,出水优于国家GB 18918-2002一级A排放标准。原水COD绝大部分作为厌氧释磷和反硝化脱氮所需碳源,系统对碳源有效利用率达74%;DO和ORP 的协同控制可以作为系统厌氧放磷段的控制参数;同时亦可作为缺氧段反硝化完成和好氧段硝化完成的指示性参数。  相似文献   

13.
多点进水改良型复合A2/O处理低C/N污水   总被引:1,自引:0,他引:1       下载免费PDF全文
李思敏  杜国帅  唐锋兵 《化工学报》2013,64(10):3805-3811
以低C/N比城市生活污水为研究对象,重点考查了改良A2/O工艺的脱氮除磷性能。原水按一定比例分配给厌氧池和缺氧池,以合理分配厌氧释磷和缺氧反硝化所需的碳源;在好氧池和缺氧池中分别投加填料,以稳定系统的硝化和反硝化效果,提高系统的脱氮性能;厌氧池和缺氧池出水都直接进入好氧池。在进水COD/TN平均为5.54,HRT为11 h,SRT为15 d,MLSS为3000~4000 mg·L-1,污泥回流比为50%条件下,通过三种不同进水分配比以及三种混合液回流比的对比试验研究,得到系统最佳进水分配比5:5,对分配脱氮和除磷所需碳源更加合理;而混合液回流比为200%,过高会破坏缺氧池的溶解氧环境,过低又会导致缺氧池反硝化作用不能充分发挥。在最优工况下COD、NH3-N、TN和TP出水水质分别为29.7、0.1、11.8和0.42 mg·L-1,平均去除率分别达到87.8%、99.7%、72.4%和91.3%,出水优于国家GB 18918-2002一级A排放标准,并且在缺氧池中发生了明显的反硝化除磷现象。  相似文献   

14.
为解决现有SBR工艺的容积交换率低、运行稳定性不足等问题,提出了基于污泥转移的SBR工艺,介绍了基于污泥转移SBR工艺的基本概念和原理,研究了在推荐工况下的除污性能。结果表明,该工艺对COD的平均去除率>80%,出水COD稳定在45 mg.L-1左右。出水NH4+-N、TN随进质量水浓度的增加而增加,但平均去除率分别稳定在94%和64%。磷酸盐的平均去除率为96%,出水磷酸盐质量浓度稳定在0.3 mg.L-1以下。  相似文献   

15.
厌氧段HRT对A2N工艺反硝化除磷脱氮效果的影响   总被引:7,自引:0,他引:7  
为了考察厌氧段水力停留时间(HRT)对A2N工艺反硝化除磷脱氮效果的影响,采用连续流双污泥反硝化除磷脱氮装置以生活污水为处理对象,研究了厌氧段在不同HRT时系统的除磷脱氮效果,以及厌氧段不同HRT对系统处理过程的影响。结果表明,厌氧段是A2N工艺实现反硝化除磷脱氮的关键阶段。当厌氧段的HRT过长时,虽然溶解性PO4^3-的总释放量增加,但是后续的缺氧吸磷量和总氮的去除量并没有相应地增加。厌氧段的HRT时间过短,反硝化聚磷菌(DPB)在此对进水中易降解COD(CODRB)吸收不完全,导致后续缺氧吸磷量下降,同时影响了系统的除磷和脱氮效果。在处理实际生活污水水质时,厌氧段的HRT为2h即可满足除磷和脱氮要求。  相似文献   

16.
采用实验室规模连续流厌氧-缺氧-好氧(A/A/O)工艺处理人工模拟生活污水,考察了不同碳氮比(C/N)和溶解氧(DO)工况下改变缺氧池容积对A^2/O工艺脱氮除磷效果的影响。结果表明,在低C/N和好氧阶段DO含量较低时,增大缺氧池容积有利于提高TN的去除率和除磷效率,在COD/ρ(TN)(ρ(TN)≈40 mg/L)约为7,DO的质量浓度在0.9~1.2 mg/L的条件下,缺氧池容积增加1倍,TN去除率可达71.1%,PO4^3--P去除率可达94.0%;在高C/N和好氧阶段DO含量较高时,增大缺氧池容积在提高TN去除率和改善出水水质方面效果不显著。  相似文献   

17.
碳氮比对AAO-BAF工艺运行性能的影响   总被引:3,自引:0,他引:3       下载免费PDF全文
AAO-BAF工艺由厌氧-缺氧-好氧反应器和曝气生物滤池组成,属于外硝化反硝化除磷工艺。以实际生活污水为处理对象,通过调节进水COD浓度(从211 mg·L-1增加到675 mg·L-1),研究了进水COD和TN的比(C/N)对AAO-BAF工艺运行性能的影响。结果表明,进水有机物浓度低或高,可以通过限制厌氧释磷量或竞争AAO反应器缺氧区的NO3-,从而影响工艺的反硝化除磷效果。当进水C/N大于4,小于7时,AAO-BAF工艺对COD、TN和PO43-的去除率分别可达86%、78%和90%以上。很高的C/N(如9.5)会使缺氧区内存在大量挥发性脂肪酸(VFA),导致普通反硝化菌迅速消耗反硝化聚磷菌(DPAOs)的电子受体NO3-。  相似文献   

18.
为了提高污水脱氮除磷的效率,研究采用序批式反应器(SBR工艺)厌氧、好氧和缺氧(AOA)的运行方式富集反硝化聚磷菌(DPB),实现同步脱氮除磷。结果表明:在好氧段投加甲醇作为碳源(25—40 mg/L)可有效抑制好氧吸磷,对硝化反应影响较小,能够在缺氧段实现同时反硝化脱氮除磷。SBR反应器稳定运行10个月,当进水NH4+-N、PO43--P分别为30,15 mg/L时,总氮(TN)和PO43--P的平均去除率分别为82.5%和92.1%。聚磷菌能够利用硝酸盐作为电子受体,DPB占总聚磷菌的比例达到44.8%。与A2O运行方式相比,AOA运行方式更有利于实现DPB的富集。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号