共查询到20条相似文献,搜索用时 218 毫秒
1.
2.
钢筋混凝土结构在土木工程中已得到广泛应用,对房屋开间较大的建筑,若采用现浇平板楼板,则板厚,混凝土及钢筋用量大,自重大,不经济;若采用密肋楼板,则材料用量省,刚度大,比较经济合理。但是,密肋楼板有其自身的缺陷,比如板薄,保温、隔声效果差,板底露梁,不平整,并且模板量大,立模复杂,工期长等。本文介绍了贵阳市五岳新村某大开间房屋采用密肋楼板的设计与施工的改造方案。该工程为砖混结构,共8层,其平面如图1所示。各层平面的厨房、卫生间采用现浇平板,卧室采用预制的预应力空心板,客厅尺寸达到6·0m×6·6m,楼面装修按贴花岗岩考虑。图1标… 相似文献
3.
4.
5.
北京图书馆新馆工程中共有6个栋号约10万m~2建筑面积采用单、双向现浇密肋楼板结构体系,使用1200型组装式聚丙烯M型系列塑料模壳,其规格尺寸如表1所示。单向密肋楼板柱网6×7.2m,柱间有现浇梁相连,楼板纵向密肋(构造肋)下口宽5cm,高35cm;横向密肋(受力肋)下口宽12.5cm,高35cm。四周为现浇框架,两向密肋钢筋均锚入大梁内(图1)。 相似文献
6.
7.
无梁楼盖体系是近年来发展较为迅速的一项建筑结构技术。较之传统密肋梁结构体系具有结构高度小、板底平整、整体性好、施工方便等优点。但同时也存在楼板较厚、材料用量较多、抗弯刚度较小、柱子周边剪应力集中导致冲切破坏、抗震性能差等缺点。近年来广泛用于高层建筑地下室及地下车库。它用于地下室设计最大的优点是可以减少地下室总埋深,尤其是地下室楼层空间减小可节约通风设备长期供电的投入。下面就某工程三层地下室的无梁楼盖进行经济技术综合分析。 相似文献
8.
9.
现浇钢筋混凝土空心楼板结构,是继普通混凝土梁板、密肋楼板、无粘结预应力平板后开发的又一种现浇结构体系。该结构的特点是在普通混凝土楼板中埋入特制的高强混凝土薄壁空心管,并与混凝土浇筑为一体,具有受力性能好、材料省、自重轻、模板简单的优点。 相似文献
10.
1 工程概况青岛颐中大酒店超高层建筑造型新颖,建筑高度1888m,建筑面积73308m2,为四星级标准的国际大酒店。主体为框架剪力墙结构,地下2层、地上41层,分主楼、附楼两个部分。主楼结构由框架柱、弧形墙、梁、无粘结预应力楼板及普通钢筋砼楼板组成,标准层层高330m,无粘结预应力板厚230mm。附楼结构4层局部5层,由模壳楼板及普通钢筋砼楼板组成,层高450m。2 工程特点1)该建筑结构形式新颖复杂。墙体为弧形墙,其中暗梁、暗柱较多,梁柱墙交叉面钢筋纵横交错较为密集。主楼1~38层楼板均采用无粘结预应力钢筋砼,屋顶大坡度钢筋砼梁板,泵送… 相似文献
11.
12.
针对目前装配式建筑中常用的钢筋混凝土叠合楼板自重较大、工厂标准化生产的预制底板规格尺寸较小的问题,提出了一种由两块预制普通混凝土大板通过一条整体式接缝拼装,并后浇轻质页岩陶粒混凝土而成的大开间叠合楼板,页岩陶粒混凝土后浇层可有效减小楼板自重,提高楼板的保温、隔热和隔声性能。通过进行叠合板足尺试件的堆载试验,研究其在竖向荷载作用下的承载力、变形特征、破坏形态及整体式接缝的传力性能。结果表明,该大开间叠合板试件在正常使用极限状态下的跨中挠度和裂缝宽度均满足相关规范要求,且表现出明显的双向板裂缝分布特征,所采用的整体式接缝具有良好的传力性能,可以作为结构楼板使用。此外,有限元模型所选取的材料本构模型和接触面设定较为合理,计算结果与试验结果吻合良好,可用于轻质混凝土叠合楼板受力性能及影响参数分析。 相似文献
13.
对双向密肋楼板体系的优点进行了分析与总结,以天津某厂房结构中区格分析为例,比较了以塑料模壳为模板的混凝土密肋梁与普通梁结构体系的各项技术经济指标,经综合分析,前者较后者造价有大幅度降低。 相似文献
14.
15.
16.
The low damping properties of lightweight large span floor decks composed of a reinforced concrete slab on top of a steel space frame structure may lead to undesirable dynamic responses, even to ordinary human actions such as walking.This problem was investigated through laboratory tests performed on a 1:1 scale prototype of a composite floor deck structure. Experimental measurements were taken for the structure subjected to several dynamic human loads, especially those produced by the random walking of people.To compensate for the lack of damping, a passive control system was designed and installed in the composite structure prototype.The performance of the mechanical control devices was evaluated by means of straight comparisons between the experimental acceleration amplitudes obtained for the controlled and uncontrolled structure subjected to similar dynamic forces produced by one or more persons walking. The most relevant results for both time and frequency responses are presented and used to argue that small and low cost passive control devices can already be included in the design stage of a smart structure as effective accessories to substantially reduce vibrations induced by people in low damped large span composite floor decks. 相似文献
17.
18.
利用SAP2000软件对预应力张拉施工过程进行分析可知,考虑钢筋混凝土框架、肋梁楼盖以及支撑体系共同工作后,预应力张拉对边跨框架梁及其附近楼板内力和变形影响较大;考虑楼板的约束作用,框架梁反拱值、梁端压缩值和梁混凝土应力等与实测值较接近;考虑肋梁楼盖的三维计算模型更能反映实际工作状况。 相似文献
19.
简单描述了"蜂巢芯"结构的来源及原理,对"蜂巢芯"空腹密肋楼盖的功能特点作了详细论述,指出"蜂巢芯"空腹密肋楼盖提升了使用功能,降低了层高,隔热性能好,且施工方便快捷。 相似文献
20.
根据3块足尺页岩陶粒轻质混凝土双向叠合楼板试件和1块足尺现浇双向楼板对比试件的静力堆载试验结果,分析了双向叠合楼板预制底板的普通混凝土和后浇叠合层的页岩陶粒轻质混凝土采用相同强度等级时的挠度变形特点,并根据试验结果和弹性力学薄板理论推导了页岩陶粒轻质混凝土双向叠合楼板的挠度计算公式。推导了四边固支页岩陶粒混凝土和普通混凝土叠合板在竖向均布荷载作用下截面中和轴高度、抗弯刚度和挠度的计算表达式,并分别对挠度和初始刚度计算公式进行了修正,提出了考虑四边支承转动的页岩陶粒轻质混凝土双向叠合楼板挠度计算公式。结果表明:页岩陶粒轻质混凝土双向叠合楼板跨中位移呈现线弹性变化特征,页岩陶粒轻质混凝土材料的弹性模量、叠合楼板中设置的钢筋桁架以及双向叠合板的板端约束条件是影响叠合楼板刚度和跨中挠度的主要因素;采用所推导公式计算的页岩陶粒混凝土叠合楼板的挠度值与试验值吻合良好。 相似文献