首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
It is unclear whether new devices such as directional coronary atherectomy (DCA) or Palmaz-Schatz stent implantation improve long-term outcomes compared with conventional balloon angioplasty in patients with stable angina and de novo coronary artery lesions of type A or type B except for complete occlusive lesions investigated by the American College of Cardiology/American Heart Association task force on percutaneous transluminal coronary angioplasty. A total of 146 patients with stable angina and simple lesions were assigned to either conventional balloon angioplasty (62 patients), DCA (50 patients), or Palmaz-Schatz implantation (34 patients). The acute results and late outcomes were assessed by coronary angiography. The results of the three procedures were similar with respect to procedural success and complications. Patients who underwent stenting or DCA had a larger immediate increase in the diameter of the lumen and a larger luminal diameter immediately after the procedure than those who underwent balloon angioplasty. At six months follow-up, the patients treated by stenting continued to have a larger luminal diameter and a lower rate of restenosis than those treated with balloon angioplasty (2.30 +/- 0.66 vs 1.85 +/- 0.83 mm, p < 0.005; 5.9% vs 29%, p < 0.05) and DCA (2.30 +/- 0.66 vs 1.90 +/- 0.96 mm, p < 0.05; 5.9% vs 24%, NS). The patients treated with balloon angioplasty had a smaller late loss than those treated with DCA or Palmaz-Schatz stent. The patients treated with DCA had a larger loss index than those treated with balloon angioplasty or Palmaz-Schatz stent. Stenting was a significant factor in decreasing the rate of restenosis by logistic regression analysis, compared with balloon angioplasty. The angiographic outcomes were better in patients who received a stent than in those who received other treatments. This study suggests that even lesions stable for treatment by balloon angioplasty and DCA can also be treated with Palmaz-Schatz stents.  相似文献   

2.
BACKGROUND: Intracoronary stenting reduces the rate of restenosis after angioplasty in patients with new coronary lesions. We conducted a prospective, randomized, multicenter study to determine whether intracoronary stenting, as compared with standard balloon angioplasty, reduces the recurrence of luminal narrowing in restenotic lesions. METHODS: A total of 383 patients who had undergone at least one balloon angioplasty and who had clinical and angiographic evidence of restenosis after the procedure were randomly assigned to undergo standard balloon angioplasty (192 patients) or intracoronary stenting with a Palmaz-Schatz stent (191 patients). The primary end point was angiographic evidence of restenosis (defined as stenosis of more than 50 percent of the luminal diameter) at six months. The secondary end points were death, Q-wave myocardial infarction, bypass surgery, and revascularization of the target vessel. RESULTS: The rate of restenosis was significantly higher in the angioplasty group than in the stent group (32 percent as compared with 18 percent, P= 0.03). Revascularization of the target vessel at six months was required in 27 percent of the angioplasty group but in only 10 percent of the stent group (P=0.001). This difference resulted from a smaller mean (+/-SD) minimal luminal diameter in the angioplasty group (1.85+/-0.56 mm) than in the stent group (2.04+/-0.66 mm), with a mean difference of 0.19 mm (P=0.01) at follow-up. Subacute thrombosis occurred in 0.6 percent of the angioplasty group and in 3.9 percent of the stent group. The rate of event-free survival at 250 days was 72 percent in the angioplasty group and 84 percent in the stent group (P=0.04). CONCLUSIONS: Elective coronary stenting was effective in the treatment of restenosis after balloon angioplasty. Stenting resulted in a lower rate of recurrent stenosis despite a higher incidence of subacute thrombosis.  相似文献   

3.
With the increasing clinical application of new devices for percutaneous coronary revascularization, maximization of the acute angiographic result has become widely recognized as a key factor in maintained clinical and angiographic success. What is unclear, however, is whether the specific mode of action of different devices might exert an additional independent effect on late luminal renarrowing. The purpose of this study was to investigate such a difference in the degree of provocation of luminal renarrowing (or 'restenosis propensity') by different devices, among 3660 patients, who had 4342 lesions successfully treated by balloon angioplasty (n = 3797), directional coronary atherectomy (n = 200), Palmaz-Schatz stent implantation (n = 229) or excimer laser coronary angioplasty (n = 116) and who also underwent quantitative angiographic analysis pre- and post-intervention and at 6-month follow-up. To allow valid comparisons between the groups, because of significant differences in coronary vessel size (balloon angioplasty = 2.62 +/- 0.55 mm, directional coronary atherectomy = 3.28 +/- 0.62 mm, excimer laser coronary angioplasty = 2.51 +/- 0.47 mm, Palmaz-Schatz = 3.01 +/- 0.44 mm; P < 0.0001), the comparative measurements of interest selected were the 'relative loss' in luminal diameter (RLoss = loss/vessel size) to denote the restenosis process, and the 'relative lumen at follow-up' (RLfup = minimal luminal diameter at follow up/vessel size) to represent the angiographic outcome. For consistency, lesion severity pre-intervention was represented by the 'relative lumen pre' (RLpre = minimal luminal diameter pre/vessel size) and the luminal increase at intervention was measured as 'relative gain' (relative gain = gain/ vessel size). Differences in restenosis propensity between devices was evaluated by univariate and multivariate analysis. Multivariate models were constructed to determine relative loss and relative lumen at follow-up, taking account of relative lumen pre-intervention, lesion location, relative gain, vessel size and the device used. In addition, model-estimated relative loss and relative lumen at follow-up at given relative lumen pre-intervention relative gain and vessel size, were compared among the four groups. Significant differences were detected among the groups both with respect to these estimates, as well as in the degree of influence of progressively increasing relative gain, on the extent of renarrowing (relative loss) and angiographic outcome (relative lumen at follow-up), particularly at higher levels of luminal increase (relative gain). Specifically, lesions treated by balloon angioplasty or Palmaz-Schatz stent implantation (the predominantly 'dilating' interventions) were associated with more favourable angiographic profiles than directional atherectomy or excimer laser (the mainly 'debulking' interventions). Significant effects of lesion severity and location, as well as the well known influence of luminal increase on both luminal renarrowing and late angiographic outcome were also noted. These findings indicate that propensity to restenosis after apparently successful intervention is influenced not only by the degree of luminal enlargement achieved at intervention, but by the device used to achieve it. In view of the clinical implications of such findings, further evaluation in larger randomized patient populations is warranted.  相似文献   

4.
OBJECTIVES: A study was set up to validate the safety and feasibility of intravascular ultrasound-guided stenting without subsequent anticoagulation, and its impact on the 6 months restenosis rate. METHODS: The study was designed to be multicentred, prospective, and observational. RESULTS: One hundred and sixty-one patients with stable angina and a de novo coronary artery lesion were enrolled. In four patients, the implantation of a Palmaz-Schatz (with spiral bridge) stent had failed. One of these four patients died 3 days following bypass surgery. In two other patients, intravascular ultrasound assessment was not performed. One hundred and twenty-five of the remaining 155 patients (81%) were treated with aspirin (100 mg x day(-1)), because all three criteria for optimized stent expansion were met. Twenty-two of the remaining 38 patients (25%), in whom at least one criterion was not met were treated with aspirin and acenocoumarol (3 months, INR 2.5-3.5), while 16 patients only received aspirin. Stent thrombosis was documented in two patients (1.3%) for which repeat angioplasty was performed. During the hospital stay, there were no deaths or Q-wave myocardial infarctions. Five patients (3.2%) sustained a non-Q-wave myocardial infarction. During the follow-up period (198+/-38 days, complete for all patients, except one), one patient (0.6%) sustained a Q-wave myocardial infarction, one (0.6%) underwent bypass surgery, and repeat angioplasty was performed in nine patients (5.7%). In two of the nine patients, repeat angioplasty involved another lesion. Therefore, the target lesion revascularization rate during follow-up was 4.5% (seven patients). At quantitative coronary angiography, the minimal lumen diameter (mean+/-SD) increased from 1.12+/-0.34 mm before to 2.89+/-0.35 mm after stenting. Repeat angiography at 6 months was performed in 144 patients (92%). The minimal lumen diameter at follow-up was 2.12+/-0.67 mm. Restenosis (diameter stenosis of 50% or more) was documented in 12 patients or 8.3%. When the two patients with documented stent thrombosis are included, the restenosis rate amounts to 97%. CONCLUSIONS: These data confirm that, in selected patients, stents can safely be implanted without the use of systemic anticoagulation, provided optimal stent expansion is achieved. The exact role of intravascular ultrasound in the achievement of these results needs to be established by appropriately designed studies. In the meantime, intravascular ultrasound coupled with the Palmaz-Schatz stent incorporating a spiral bridge, may have contributed considerably to the immediate angiographic outcome, which in turn may explain the favourable clinical and angiographic outcome at 6 months.  相似文献   

5.
We evaluated acute and long-term clinical and angiographic results of elective Palmaz-Schatz coronary stent implantation for left anterior descending coronary artery (LAD) ostial stenosis in 23 consecutive patients. Eight patients had stable angina, 14 had unstable angina, and 1 had recent myocardial infarction. Sixteen patients had single-vessel, 5 had double-vessel, and 2 had triple-vessel disease. Clinical success without major complications (death, acute myocardial infarction, emergency coronary artery bypass grafting) was obtained in all cases and technical success in 20 cases (86.9%). After stenting, minimal lumen diameter increased from 1.05 +/- 0.45 mm to 2.89 +/- 0.52 mm (p < 0.001), and percent diameter stenosis decreased from 65.49% +/- 13.36% to 2.94% +/- 19.93% (p < 0.001). One case of subacute thrombosis and no major bleeding occurred. Twenty patients were followed-up for 6 months, during which no acute cardiac event (death, acute myocardial infarction) was observed. Eighteen patients were eligible for follow-up coronary angiography; restenosis (> or = 50% diameter stenosis) was observed in 4 (22.2%). Minimal lumen diameter was 1.77 +/- 0.55 mm, percent diameter stenosis was 39.66% +/- 17.62%, late loss was 1.01 +/- 0.69 mm, net gain was 0.79 +/- 0.55 mm, and loss index (late loss/acute gain) was 0.53 +/- 0.37. This study suggests that elective Palmaz-Schatz stent implantation may be a safe and successful treatment of LAD ostial lesions and provides a large increase in lumen diameter.  相似文献   

6.
OBJECTIVES: The purpose of this prospective single-center study was to evaluate the longer-term outcome of Palmaz-Schatz stenting in the treatment of native coronary and saphenous vein bypass graft disease. BACKGROUND: The STRESS (Stent Restenosis Study) and BENESTENT (Belgian Netherlands Stent) trials have demonstrated a decrease in both angiographic restenosis and the need for repeat revascularization in the 1st year for vessels treated by stenting rather than balloon angioplasty. Longer-term (1 to 5 years) clinical results of Palmaz-Schatz stenting are not yet well established. Late migration of the stent, metal fatigue, endarteritis and late restenosis have all been proposed as potential late clinical complications of coronary stent implantation. METHODS: The study cohort consisted of 175 consecutive patients who underwent elective placement of 194 Palmaz-Schatz stents in 185 vessels. Clinical events (death, myocardial infarction, recurrent angina or any revascularization) were assessed at 6 weeks, 2, 4 and 6 months, 1 year and yearly thereafter. Clinical follow-up was available on all patients at a mean +/- SD of 54 +/- 17 months. RESULTS: Angiographic success was achieved in 173 patients (98.9%); angiographic restenosis was observed at 6 months in 26.1% of target sites. The survival rate was 86.7% at 5 years, with a 5-year event-free survival rate decreasing progressively to 50.7%, reflecting primarily repeat revascularization procedures (41.2% at 5 years). However, the rate of repeat revascularization of the treatment site (target site revascularization [TSR]) was 14.4%, 17.7% and 19.8% at 1, 3 and 5 years, respectively, with late (> 1 year) TSR driven by in-stent restenosis in only 3 patients (1.7%). Rates of both 5-year survival (70.5% vs. 93.4%) and event-free survival (21.1% vs. 63.3%) were lower for patients who underwent saphenous vein graft (SVG) stenting than for those with native coronary artery stenting. However, 5-year TSR rates were similar for SVGs (21.9%) and native vessels (19.2%), indicating that the higher incidence of repeat revascularization for SVGs was due to an increase in non-TSR, driven by progressive disease at other sites. CONCLUSIONS: The long-term outcome of stenting shows stability of the treated lesion, with only a slight increase in TSR between 2 and 5 years (17.1% to 19.8%). The progressive increase in repeat revascularization over that period (24% to 41%) and most ongoing late events can be attributed to the progression of coronary disease at other sites, rather than to late deterioration of the stent result itself. Such non-TSR events account for the majority of clinical events in the patients who underwent SVG stenting.  相似文献   

7.
The Palmaz-Schatz (PS) stent has effectively reduced restenosis; however its rigidity makes it sometimes difficult or impossible to deliver. The initial and follow-up outcomes with the ACS Multi-Link stent (deployed from April to November 1995) were evaluated in 70 patients (79 lesions): unplanned in 34% (abrupt closure 1%; threatened closure 5%; suboptimal results 28%) and planned in 66%. Three to six month follow-up angiograms were analyzable in 67 lesions; 96% procedural (in nine lesions PS stenting had failed) and 95% clinical success were achieved. In-hospital mortality was 1.4%. Myocardial infarction occurred in 2.9%, and subacute stent thrombosis in 1.4%. Stenting improved immediately the minimal luminal diameter (from 0.97+/-0.41 mm to 2.72+/-0.31 mm), but at 6 months it had decreased to 1.89+/-0.44 mm. Angiographic restenosis (<50% diameter stenosis) occurred in 11, a rate of 16.4%; target lesion revascularization (TLR) was required in six (re-PTCA in five or bypass surgery in one; 6/67=8.7%). Actuarial 1-2 year survival rate was 91%, 80% surviving free from major complications or need for TLR. We conclude that the ACS Multi-Link stent can be implanted in lesions unsuited for the PS stent with a high success rate, and an anticipated restenosis rate perhaps comparable to with the PS stent.  相似文献   

8.
Technical advancement and new anti-thrombotic regimens have recently shown so much improvement in the results of coronary stenting that the conventional contra-indication for stenting in small coronary arteries (<3 mm) needs to be revised. We undertook a prospective pilot study of elective Palmaz-Schatz stenting in de novo lesions located in coronary arteries of less than 3 mm diameter. Fifty consecutive patients (63 +/- 9 years) with stable (n = 38) and unstable angina (n = 12) were included. Philips-DCI quantitative coronary analysis was used to measure reference diameter, minimal lumen diameter and percent diameter stenosis before PTCA, after stenting and at 6-month angiographic follow-up study. All measurements were performed after intracoronary injection of nitroglycerin (300 microg). All patients received ticlopidine (250 mg/day) and aspirin (100 mg/day). The mean lesion length was 9 +/- 3 mm. The balloon size used for stent delivery was 2.75 mm in 30 patients and 2.5 mm in 20 patients and the mean balloon inflation pressure used for stent deployment was 12 +/- 2 atm. All stents were deployed successfully. In-hospital complications occurred in two patients, diagonal branch occlusion at day 2 requiring emergency PTCA in one and a hematoma at the femoral puncture site requiring surgery in the other. Major adverse cardiac event (MACE) rate remained 2% (nonfatal infarct in one). Follow-up angiography (n = 46, 92%) at 6 +/- 3 months showed a 30% restenosis rate. Target vessel revascularization (TVR) rate was 13%. We conclude that elective stenting in small coronary arteries is feasible and involves an acceptable risk of restenosis.  相似文献   

9.
BACKGROUND: Experimental studies suggest that the antiproliferative effect of heparin after arterial injury is maximized by pretreatment. No previous studies of restenosis have used a pretreatment strategy. We designed this study to determine whether treatment with nadroparin, a low-molecular-weight heparin, started 3 days before the procedure and continued for 3 months, affected angiographic restenosis or clinical outcome after coronary angioplasty. METHODS AND RESULTS: In a prospective multicenter, double-blind, randomized trial, elective coronary angioplasty was performed on 354 patients who were treated with daily subcutaneous nadroparin (0.6 mL of 10,250 anti-Xa IU/mL) or placebo injections started 3 days before angioplasty and continued for 3 months. Angiography was performed just before and immediately after angioplasty and at follow-up. The primary study end point was angiographic restenosis, assessed by quantitative coronary angiography 3 months after balloon angioplasty. Clinical follow-up was continued up to 6 months. Clinical and procedural variables and the occurrence of periprocedural complications did not differ between groups. At angiographic follow-up, the mean minimal lumen diameter and the mean residual stenosis in the nadroparin group (1.37+/-0.66 mm, 51.9+/-21.0%) did not differ from the corresponding values in the control group (1.48+/-0.59 mm, 48.8+/-18.9%). Combined major cardiac-related clinical events (death, myocardial infarction, target lesion revascularization) did not differ between groups (30.3% versus 29.6%). CONCLUSIONS: Pretreatment with the low-molecular-weight heparin nadroparin continued for 3 months after balloon angioplasty had no beneficial effect on angiographic restenosis or on adverse clinical outcomes.  相似文献   

10.
BACKGROUND: Coronary stenting has reduced restenosis in focal de novo lesions, but its impact has been less pronounced in complex lesion subsets. Preliminary data suggest a role for plaque burden in promoting intimal hyperplasia after stent implantation. The aim of this study was to test the hypothesis that plaque removal with directional atherectomy before stent implantation may lower the intensity of late neointimal hyperplasia, reducing the incidence of in-stent restenosis. METHODS AND RESULTS: Seventy-one patients with 90 lesions underwent directional atherectomy before coronary stenting. Intravascular ultrasound-guided stenting was performed in 73 lesions (81%). Clinical success was achieved in 96% of patients. Procedural complications were as follows: emergency bypass surgery in 1 patient (1.4%), who died 2 weeks later; Q-wave myocardial infarction in 2 patients (2.8%); and non-Q-wave myocardial infarction in 8 patients (11.3%). None of the patients had stent thrombosis at follow-up. Angiographic follow-up was performed in 89% of eligible patients at 5.7+/-1.7 months. Loss index was 0.33 (95% CI, 0.26 to 0.40), and angiographic restenosis was 11% (95% CI, 5% to 20%). Clinical follow-up was performed in all patients at 18+/-3 months. Target lesion revascularization was 7% (95% CI, 3% to 14%). CONCLUSIONS: Directional atherectomy followed by coronary stenting could be performed with good clinical success rate. Also, these data point to a possible reduction in angiographic restenosis and a significant reduction in the need for repeated coronary interventions. Therefore, a randomized clinical trial seems appropriate to test the validity of this approach.  相似文献   

11.
OBJECTIVE: The purpose of this study was to evaluate acute angiographic success, in-hospital complications and long-term outcome after intracoronary stenting in patients with cardiac allograft vasculopathy. BACKGROUND: The application of conventional interventional modalities to treat discrete lesions in patients with cardiac allograft vasculopathy is associated with higher procedural morbidity, mortality and higher restenosis compared to atherosclerotic coronary artery disease. Elective coronary stenting has been shown to lower restenosis rates and improve long-term outcome in selected patients with native coronary artery disease; however, its safety and efficacy in reducing restenosis in patients with cardiac allograft vasculopathy is unknown. METHODS: Ten patients with 19 discrete lesions in a major coronary artery without diffuse distal disease underwent intracoronary stenting using Palmaz-Schatz stents. The average stent size was 3.4 mm, and the stent/artery ratio was 0.99+/-0.07. Eight of ten (80%) patients received antiplatelet therapy (aspirin plus ticlopidine) only. RESULTS: Procedural success was 100% with no in-hospital stent thrombosis, Q-wave myocardial infarction or death. Minimal luminal diameter increased from 0.83+/-0.38 mm to 3.23+/-0.49 mm after stenting. Diameter stenosis decreased from 74.91+/-11.52% to 5.90+/-4.09% after stenting. Follow-up angiography was performed in 8 of 10 (80%) patients and 16 of 19 (84%) lesions. Target lesion revascularization was required in 2 of 10 (20%) patients and 3 of 16 (19%) lesions. Allograft survival was 7 of 10 (70%) at the end of 22+/-11 months follow-up. CONCLUSIONS: Intracoronary stenting can be performed safely with excellent angiographic success in selected patients with cardiac allograft vasculopathy. The restenosis rate appears to be low despite the aggressive nature of the disease. A multicenter study with a larger number of patients is required to assess its efficacy in reducing restenosis and improving allograft survival.  相似文献   

12.
BACKGROUND: Treatment of stenosis in saphenous-vein grafts after coronary-artery bypass surgery is a difficult challenge. The purpose of this study was to compare the effects of stent placement with those of balloon angioplasty on clinical and angiographic outcomes in patients with obstructive disease of saphenous-vein grafts. METHODS: A total of 220 patients with new lesions in aortocoronary-venous bypass grafts were randomly assigned to placement of Palmaz-Schatz stents or standard balloon angioplasty. Coronary angiography was performed during the index procedure and six months later. RESULTS: As compared with the patients assigned to angioplasty, those assigned to stenting had a higher rate of procedural efficacy, defined as a reduction in stenosis to less than 50 percent of the vessel diameter without a major cardiac complication (92 percent vs. 69 percent, P<0.001), but they had more frequent hemorrhagic complications (17 percent vs. 5 percent, P<0.01). Patients in the stent group had a larger mean (+/-SD) increase in luminal diameter immediately after the procedure (1.92+/-0.30 mm, as compared with 1.21+/-0.37 mm in the angioplasty group; P<0.001) and a greater mean net gain in luminal diameter at six months (0.85+/-0.96 vs. 0.54+/-0.91 mm, P=0.002). Restenosis occurred in 37 percent of the patients in the stent group and in 46 percent of the patients in the angioplasty group (P=0.24). The outcome in terms of freedom from death, myocardial infarction, repeated bypass surgery, or revascularization of the target lesion was significantly better in the stent group (73 percent vs. 58 percent, P = 0.03). CONCLUSIONS: As compared with balloon angioplasty, stenting of selected venous bypass-graft lesions resulted in superior procedural outcomes, a larger gain in luminal diameter, and a reduction in major cardiac events. However, there was no significant benefit in the rate of angiographic restenosis, which was the primary end point of the study.  相似文献   

13.
Conventional balloon angioplasty treatment of aorto-ostial stenoses in native coronary arteries and saphenous vein grafts is associated with a low primary success rate, a high complication rate and a high incidence of restenosis. The short-term outcome of Palmaz-Schatz stent implantation in aorto-ostial lesions was compared with that of balloon angioplasty. Thirteen patients underwent stent implantation for 13 de novo lesions (four in the left main coronary trunk, two in the right coronary artery, seven in the vein graft) between January 1994 and December 1995. Fourteen patients underwent balloon angioplasty for 14 de novo lesions (five in the left main coronary trunk, four in the right coronary artery, five in the vein graft between January 1986 and April 1992. Both groups had similar clinical characteristics. Initial success was obtained in all patients in the stent group, compared with 71% of the balloon angioplasty group. Insufficient dilation was the main cause for such failure in the balloon angioplasty group. Baseline reference diameters were similar (3.40 +/- 0.65 mm in the stent group vs 3.36 +/- 0.42 mm in the balloon angioplasty group) and there was no difference in baseline minimal luminal diameter (1.41 +/- 0.74 vs 1.08 +/- 0.56 mm). Minimal luminal diameter was significantly greater in the stent group than in the balloon angioplasty group at both post-procedure and follow-up examinations (post: 3.36 +/- 0.58 vs 2.69 +/- 0.45 mm, p < 0.01; follow-up: 2.33 +/- 0.96 vs 1.52 +/- 0.68 mm, p < 0.05). There was no subacute occlusion in either group. The overall angiographic restenosis rate (> 50% stenosis) was lower in the stent group (17%) than in the balloon angioplasty group: the restenosis rates of native lesions were 0% in the stent group and 40% in the balloon angioplasty group; those of saphenous vein graft lesions were 33% in the stent group and 50% in the balloon angioplasty group. Although the number of patients was limited, these results suggest that Palmaz-Schatz stent implantation may be a safe and effective strategy for treating aorto-ostial lesions in both native coronary arteries and saphenous vein grafts.  相似文献   

14.
This study compares the immediate and long-term outcomes of a primary coronary stenting strategy with primary balloon angioplasty with stent bailout in the treatment of patients with acute myocardial infarction (AMI). One hundred forty-seven consecutive patients who underwent primary balloon angioplasty with stent bailout (n = 94) or primary stenting (n = 53) for AMI were clinically followed for 8.1 +/- 5.7 and 8.5 +/- 4.5 months, respectively. Immediate results, as well as in-hospital and long-term ischemic events (death, reinfarction, and repeat revascularization) were compared between both groups. Angiographic success was 91.5% in the balloon angioplasty group and 94% in the stent group. In-hospital and late follow-up combined ischemic events were 22 of 94 (23%) versus 0 of 53 (0%); p < 0.001 and 33 of 78 (42%) versus 13 of 53 (25%), p = 0.04 for the balloon angioplasty and stent groups, respectively. At 6 months, the cumulative probability of repeat target lesion revascularization was higher in the balloon angioplasty group (47% vs 18%, p = 0.0006) as was the probability of late target revascularization (36% vs 18%, p = 0.046); the cumulative event-free survival after 6 months was significantly lower in the balloon angioplasty group (44% vs 80%, p = 0.0001). This study demonstrates that a primary stent placement strategy in patients with AMI is safe, feasible, and superior to primary balloon angioplasty with stent bailout. Primary stenting results in a larger postprocedural minimal luminal diameter, a lower early and late recurrent ischemic event rate, and a lower incidence of target lesion revascularization at follow-up.  相似文献   

15.
OBJECTIVES: The purpose of this prospective study was to evaluate the immediate results and the 6-month angiographic recurrent restenosis rate after balloon angioplasty for in-stent restenosis. BACKGROUND: Despite excellent immediate and mid-term results, 20% to 30% of patients with coronary stent implantation will present an angiographic restenosis and may require additional treatment. The optimal treatment for in-stent restenosis is still unclear. METHODS: Quantitative coronary angiography (QCA) analyses were performed before and after stent implantation, before and after balloon angioplasty for in-stent restenosis and on a 6-month systematic coronary angiogram to assess the recurrent angiographic restenosis rate. RESULTS: Balloon angioplasty was performed in 52 patients presenting in-stent restenosis. In-stent restenosis was either diffuse (> or =10 mm) inside the stent (71%) or focal (29%). Mean stent length was 16+/-7 mm. Balloon diameter of 2.98+/-0.37 mm and maximal inflation pressure of 10+/-3 atm were used for balloon angioplasty. Angiographic success rate was 100% without any complication. Acute gain was lower after balloon angioplasty for in-stent restenosis than after stent implantation: 1.19+/-0.60 mm vs. 1.75+/-0.68 mm (p=0.0002). At 6-month follow-up, 60% of patients were asymptomatic and no patient died. Eighteen patients (35%) had repeat target vessel revascularization. Angiographic restenosis rate was 54%. Recurrent restenosis rate was higher when in-stent restenosis was diffuse: 63% vs. 31% when focal, p=0.046. CONCLUSIONS: Although balloon angioplasty for in-stent restenosis can be safely and successfully performed, it leads to less immediate stenosis improvement than at time of stent implantation and carries a high recurrent angiographic restenosis rate at 6 months, in particular in diffuse in-stent restenosis lesions.  相似文献   

16.
BACKGROUND: The VERAS study (VErringerung der Restenoserate nach Angioplastie durch ein Somatostatin-analogon [Prevention of Restenosis Following Angioplasty With a Somatostatin Analogue]) was a placebo-controlled trial to evaluate the effects of octreotide for the prevention of restenosis after coronary angioplasty. Octreotide is a somatostatin analogue with antiproliferative properties on smooth muscle cell growth in vitro that limits myointimal thickening of arteries in balloon injury models. METHODS AND RESULTS: Patients received either octreotide or placebo, starting 1 hour before angioplasty and continued for 3 weeks. The minimal luminal diameters before and after angioplasty and at 6-month follow-up were analyzed with a digital quantitative algorithm. Of the initial 274 patients recruited, 217 (108 in the octreotide group and 109 in the placebo group) could be analyzed after a complete 6-month evaluation: the minimal luminal diameters were 1.67+/-0.57 mm in the octreotide-treated group and 1.66+/-0.64 mm in the placebo group (two-paired P=.70), and the relative losses were 0.16+/-0.22 and 0.13+/-0.21 (two-paired P=.27). The restenosis rates were also identical in both treatment groups: final diameter stenosis > or =50% (34.3% versus 33.9%, two-paired P=1.0), loss of > or =50% of the initial gain (34.3% versus 33.9%, two-paired P=1.0), and absolute reduction of minimal luminal diameter >0.72 mm (29.6% versus 24.8%, two-paired P=.45). Likewise, there was no difference with regard to the incidence of clinical events (death, myocardial infarction, bypass operations, reintervention). Octreotide was well tolerated, with the exception of gastrointestinal side effects, which were three times more common than in the placebo group. CONCLUSIONS: Octreotide did not reduce the angiographically determined restenosis rate or the incidence of major clinical events after coronary angioplasty.  相似文献   

17.
Catheter-based radiotherapy to inhibit restenosis after coronary stenting   总被引:1,自引:0,他引:1  
BACKGROUND: In animal models of coronary restenosis, intracoronary radiotherapy has been shown to reduce the intimal hyperplasia that is a part of restenosis. We studied the safety and efficacy of catheter-based intracoronary gamma radiation plus stenting to reduce coronary restenosis in patients with previous restenosis. METHODS: Patients with restenosis underwent coronary stenting, as required, and balloon dilation and were then randomly assigned to receive catheter-based irradiation with iridium-192 or placebo. Clinical follow-up was performed, with quantitative coronary angiographic and intravascular ultrasonographic measurements at six months. RESULTS: Fifty-five patients were enrolled; 26 were assigned to the iridium-192 group and 29 to the placebo group. Angiographic studies were performed in 53 patients (96 percent) at a mean (+/-SD) of 6.7+/-2.2 months. The mean minimal luminal diameter at follow-up was larger in the iridium-192 group than in the placebo group (2.43+/-0.78 mm vs. 1.85+/-0.89 mm, P=0.02). Late luminal loss was significantly lower in the iridium-192 group than in the placebo group (0.38+/-1.06 mm vs. 1.03+/-0.97 mm, P=0.03). Angiographically identified restenosis (stenosis of 50 percent or more of the luminal diameter at follow-up) occurred in 17 percent of the patients in the iridium-192 group, as compared with 54 percent of those in the placebo group (P= 0.01). There were no apparent complications of the treatment. CONCLUSIONS: In this preliminary, short-term study of patients with previous coronary restenosis, coronary stenting followed by catheter-based intracoronary radiotherapy substantially reduced the rate of subsequent restenosis.  相似文献   

18.
This study was designed to test the hypothesis that patients fulfilling intravascular ultrasound (IVUS) criteria for optimal coronary stent implantation show a reduction in the restenosis rate at 6 months. IVUS guidance for stent dilation may be associated with facilitated stent implantation and an increased acute luminal gain, but it has not yet been determined, whether and to what extent this procedure is associated with a reduction in the restenosis rate. IVUS-guided optimization of Palmaz-Schatz stent placement was performed in 125 consecutive patients, 64 of whom fulfilled IVUS-criteria for optimal stent placement. Another 125 patients served as the non-IVUS control group. In 107 patients (86%) of the non-IVUS control group and 105 patients (84%) of the IVUS group, angiographic follow-up was performed. The IVUS group of patients revealed a significantly lower restenosis rate of 20.9% as compared with 29.9% in the control group (P = 0.033). Patients that met IVUS criteria for optimal stent placement had a larger minimal lumen diameter immediately after stent implantation (3.13 +/- 0.44 vs. 2.95 +/- 0.47 mm; P = 0.045) and at 6-month follow-up (2.23 +/- 0.78 vs. 1.87 +/- 0.76 mm; P = 0.019) as well as a significantly lower restenosis rate (13.5% vs. 28.3%; P = 0.038) as compared with patients that did not fulfil these criteria. Our data suggest that patients fulfilling IVUS criteria for optimal stent placement demonstrate a reduced risk for the development of restenosis. Thus, IVUS investigation identifies factors predictive of restenosis after coronary stent placement.  相似文献   

19.
Between February 1995 to August 1997, 120 patients underwent elective stent implantation for isolated proximal left anterior descending coronary artery stenosis. Their age ranged from 31 to 72 years (mean: 50.8 +/- 10.2) and the majority (89%) were males. All patients had angina, documented myocardial ischemia or both and 70 percent or more luminal diameter stenosis in the proximal left anterior descending before the origin of any branch. Majority (62.5%) of the treated lesions were type A. Successful deployment of the stent at the target site was achieved in all patients without any major in-hospital complications, including myocardial infarction, emergency bypass graft surgery or death. Clinical follow-up, ranging from 6 to 31 months (mean: 18.5 +/- 8.1, median: 20), was available in 87 out of 92 (94.5%) eligible patients who had completed at least six months after the procedure. Freedom from angina, myocardial infarction, target lesion revascularization and death was observed in 90.8, 100, 95.4 and 97.7 percent of patients, respectively. By the Kaplan-Meier estimate, an event-free survival (absence of death, myocardial infarction, recurrence of angina or revascularization) was 95.4 percent at six months, 89.5 percent at 12 and 18 months and 82.7 percent at 24 to 31 months of follow-up. Only 10 (11.5%) patients developed any event and TLR was required in 4.6 percent of patients. In conclusion, elective stenting for isolated proximal left anterior descending stenosis can be achieved safely and successfully in all patients without any adverse in-hospital events. This modality of treatment also provides long-term benefits in terms of reduction in major cardiovascular events and need for subsequent revascularization.  相似文献   

20.
OBJECTIVES: This study sought to evaluate preintervention and postintervention intravascular ultrasound studies for potential predictors of angiographic restenosis and to use ultrasound predictors of restenosis to enhance our understanding of the pathophysiology of the restenosis disease process. BACKGROUND: Restenosis remains the major limitation of percutaneous transcatheter coronary revascularization. Although its mechanisms remain incompletely understood, numerous studies have identified some of the clinical, anatomic and procedural risk factors for restenosis. Intravascular ultrasound imaging of target lesions before and after catheter-based treatment consistently demonstrates more target lesion calcium, more extensive reference segment atherosclerosis, smaller final lumen dimensions, significant residual plaque burden and a greater degree of tissue trauma than is evident by angiography. METHODS: Intravascular ultrasound studies were performed in 360 nonstented native coronary artery lesions (final diameter stenosis 18 +/- 11%) in 351 patients for whom follow-up angiographic data were available 6.4 +/- 3.6 months later. Hospital charts were reviewed, and qualitative and quantitative coronary angiographic and intravascular ultrasound analyses were performed by independent core laboratories. Four dependent angiographic end points were tested: restenosis as a binary definition (> or = 50% diameter stenosis at follow-up) was the primary end point; follow-up diameter stenosis, late lumen loss and follow-up minimal lumen diameter were the secondary end points. RESULTS: Reference vessel size, the preintervention quantitative coronary angiographic assessment of lesion severity and the postintervention intravascular ultrasound cross-sectional measurements predicted the late angiographic results. In particular, the intravascular ultrasound postintervention cross-sectional narrowing (plaque plus media cross-sectional area divided by external elastic membrane cross-sectional area) predicted the primary end point (restenosis) and two of the three secondary end points (follow-up diameter stenosis and late lumen loss) and was therefore the most consistent predictor of restenosis. CONCLUSIONS: Intravascular ultrasound variables are more powerful and consistent predictors of angiographic restenosis than currently accepted clinical or angiographic risk factors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号