首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
During 2005-2007, a woodstove changeout program was conducted in a Rocky Mountain valley community in an effort to reduce ambient levels of PM(2.5). In addition to changes in ambient PM(2.5), an opportunity was provided to evaluate the changes in indoor air quality when old stoves were replaced with US Environmental Protection Agency (EPA)-certified woodstoves. PM(2.5) samples were measured in 16 homes prior to and following the changeout. For each sampling event, PM(2.5) mass was continuously measured throughout the 24-h sampling periods, and organic/elemental carbon (OC/EC) and associated chemical markers of woodsmoke were measured from quartz filters. Results showed that average PM(2.5) concentrations and maximum PM(2.5) concentrations were reduced by 71% and 76%, respectively (as measured by TSI DustTraks). Levoglucosan was reduced by 45% following the introduction of the new woodstove. However, the concentrations of resin acids, natural chemicals found in the bark of wood, were increased following the introduction of the new woodstove. There were no discernible trends in methoxphenol levels, likely due to the semi-volatile nature of the species that were measured. Although there is some uncertainty in this study regarding the amount of ambient PM infiltration to the indoor environment, these findings demonstrated a large impact on indoor air quality following this intervention. PRACTICAL IMPLICATIONS: Emissions from residential woodstoves are an important air quality issue (both indoors and ambient) in many regions throughout the US and the world. More specifically, woodstoves have been identified as a major source of PM(2.5) in valley locations throughout the Northern Rocky Mountains, where biomass combustion is the predominant source of home heating. In this study, we present results that demonstrate the dramatic reduction in PM(2.5) concentrations (as measured by TSI, Inc. DustTrak PM(2.5) air samplers) inside homes following the replacement of old, polluting woodstove with new EPA-certified woodstoves.  相似文献   

2.
A woodstove changeout program was conducted within 16 homes on the Nez Perce Reservation in Idaho to evaluate the effectiveness of a woodstove changeout in improving indoor air quality. PM2.5 samples were collected within the common area (rooms where the stoves were located) of the homes both before and after the installation of cleaner burning EPA-certified stoves. During the pre- and post-changeout sampling, indoor PM2.5 mass, Organic Carbon (OC), Elemental Carbon (EC), and chemical markers of woodsmoke (including levoglucosan) were measured.Sampling results from this study showed that indoor air quality was improved in 10 of the 16 homes following the woodstove changeout and educational training program. Five homes had increased indoor PM2.5 concentrations following the changeout, while one home did not have final PM2.5 results for comparison. The median pre-changeout PM2.5 mass (as measured by TSI DustTraks) was 39.2 μg/m3, with a median post-changeout concentration of 19.0 μg/m3. This resulted in an overall 52% reduction in median indoor PM2.5, a 36% reduction in mean indoor PM2.5 and a 60% reduction in PM2.5 spikes when the old stoves were replaced with EPA-certified stoves. Another significant finding of the project was that targeted education and outreach is a critical component of the overall success of the program. Effective messaging to homeowners on proper use of their new stove is a necessary task of a woodstove changeout.  相似文献   

3.
The literature on the contribution of kerosene lighting to indoor air particulate concentrations is sparse. In rural Uganda, kitchens are almost universally located outside the main home, and kerosene is often used for lighting. In this study, we obtained longitudinal measures of particulate matter 2.5 microns or smaller in size (PM2.5) from living rooms and kitchens of 88 households in rural Uganda. Linear mixed‐effects models with a random intercept for household were used to test the hypotheses that primary reported lighting source and kitchen location (indoor vs outdoor) are associated with PM2.5 levels. During initial testing, households reported using the following sources of lighting: open‐wick kerosene (19.3%), hurricane kerosene (45.5%), battery‐powered (33.0%), and solar (1.1%) lamps. During follow‐up testing, these proportions changed to 29.5%, 35.2%, 18.2%, and 9.1%, respectively. Average ambient, living room, and kitchen PM2.5 levels were 20.2, 35.2, and 270.0 μg/m3. Living rooms using open‐wick kerosene lamps had the highest PM2.5 levels (55.3 μg/m3) compared to those using solar lighting (19.4 μg/m3; open wick vs solar, P=.01); 27.6% of homes using open‐wick kerosene lamps met World Health Organization indoor air quality standards compared to 75.0% in homes using solar lighting.  相似文献   

4.
Rural areas of developing countries are particularly reliant on biomass for cooking and heating. Women and children in these areas are often exposed to high levels of pollutants from biomass combustion that is associated with a range of respiratory symptoms. Domestic exposure to carbon monoxide (CO) and respirable particles (RSPs) in association with respiratory symptoms among women and children in Zimbabwe was investigated in 48 households. Health status and household characteristics were also recorded. In this study, indoor levels of CO and RSPs exceeded World Health Organization (WHO) air quality guidelines in over 95% of kitchens. The level of indoor air pollutants was associated with the area of kitchen windows and the length of cooking time combined with the level of fire combustion. Prevalence of respiratory symptoms was 94% for women and 77% for children. In addition, women reporting respiratory symptoms were exposed to higher levels of RSPs when compared with those reporting no respiratory symptoms. The study results indicated that levels of indoor air pollutants in rural Zimbabwe may contribute to respiratory symptoms in both women and children. PRACTICAL IMPLICATIONS: Levels of respirable particles and carbon monoxide in kitchens in rural Zimbabwe are unacceptably high and measures to reduce levels should be undertaken. Based on the study findings, recommendations for increasing the area of kitchen windows may be considered as a practical method of reducing indoor air pollutants in rural Zimbabwe.  相似文献   

5.
广州夏季高温高湿,基于广州城乡老年人的室内环境差异,通过问卷调查了解了116 名广州城乡老年人的室内居住环境, 并对5 户典型城市及5 户典型农村65 岁以上居民住宅的夏季室内环境进行了对比实测研究,测量每户住宅的客厅,卧室和卫 生间的温度、相对湿度及CO2、CO、PM2.5、挥发性有机物浓度。研究表明,广州农村住户夏季主要使用风扇降温,仅有约三 分之一住户同时使用空调,而城市住户均使用空调,大部分住户同时使用风扇;广州农村住户夏季室内平均空气温度比城市住 户低0.8 ℃,平均相对湿度比城市住户高21.6%;通风较差的住户室内CO2 浓度相对较高,所有实测城市及农村住户的CO、 PM2.5 的浓度都低于国家标准规定的极限值;广州城市住户的室内外PM2.5 浓度及室内总挥发性有机物的浓度总体高于农村住户。 广州农村老年人住宅应加强防潮处理,城市老年人住宅应加强通风换气,优选环保家具。  相似文献   

6.
Solid fuel burning cookstoves are a major source of household air pollution (HAP) and a significant environmental health risk in Sri Lanka. We report results of the first field study in Sri Lanka to include direct measurements of both real‐time indoor concentrations and personal exposures of fine particulate matter (PM2.5) in households using the two most common stove types in Sri Lanka. A purposive sample of 53 households was selected in the rural community of Kopiwatta in central Sri Lanka, roughly balanced for stove type (traditional or improved ‘Anagi’) and ventilation (chimney present or absent). At each household, 48‐h continuous real‐time measurements of indoor kitchen PM2.5 and personal (primary cook) PM2.5 concentrations were measured using the RTI MicroPEM? personal exposure monitor. Questionnaires were used to collect data related to household demographics, characteristics, and self‐reported health symptoms. All primary cooks were female and of an average age of 47 years, with 66% having completed primary education. Median income was slightly over half the national median monthly income. Use of Anagi stoves was positively associated with a higher education level of the primary cook (P = 0.026), although not associated with household income (P = 0.18). The MicroPEM monitors were well‐received by participants, and this study's valid data capture rate exceeded 97%. Participant wearing compliance during waking hours was on average 87.2% on Day 1 and 83.3% on Day 2. Periods of non‐compliance occurred solely during non‐cooking times. The measured median 48‐h average indoor PM2.5 concentration for households with Anagi stoves was 64 μg/m3 if a chimney was present and 181 μg/m3 if not. For households using traditional stoves, these values were 70 μg/m3 if a chimney was present and 371 μg/m3 if not. Overall, measured indoor PM2.5 concentrations ranged from a minimum of 33 μg/m3 to a maximum of 940 μg/m3, while personal exposure concentrations ranged from 34 to 522 μg/m3. Linear mixed effects modeling of the dependence of indoor concentrations on stove type and presence or absence of chimney showed a significant chimney effect (65% reduction; P < 0.001) and an almost significant stove effect (24% reduction; P = 0.054). Primary cooks in households without chimneys were exposed to substantially higher levels of HAP than those in households with chimneys, while exposures in households with traditional stoves were moderately higher than those with improved Anagi stoves. As expected, simultaneously measuring both indoor concentrations and personal exposure levels indicate significant exposure misclassification bias will likely result from the use of a stationary monitor as a proxy for personal exposure. While personal exposure monitoring is more complex and expensive than deploying simple stationary devices, the value an active personal PM monitor like the MicroPEM adds to an exposure study should be considered in future study designs.  相似文献   

7.
Approximately half of all children under two years of age in Bangladesh suffer from an acute lower respiratory infection (ALRI) each year. Exposure to indoor biomass smoke has been consistently associated with an increased risk of ALRI in young children. Our aim was to estimate the effect of indoor exposure to particulate matter (PM2.5) on the incidence of ALRI among children in a low‐income, urban community in Bangladesh. We followed 257 children through two years of age to determine their frequency of ALRI and measured the PM2.5 concentrations in their sleeping space. Poisson regression was used to estimate the association between ALRI and the number of hours per day that PM2.5 concentrations exceeded 100 μg/m3, adjusting for known confounders. Each hour that PM2.5 concentrations exceeded 100 μg/m3 was associated with a 7% increase in incidence of ALRI among children aged 0–11 months (adjusted incidence rate ratio (IRR) 1.07, 95% CI 1.01–1.14), but not in children 12–23 months old (adjusted IRR 1.00, 95% CI 0.92–1.09). Results from this study suggest that reducing indoor PM2.5 exposure could decrease the frequency of ALRI among infants, the children at highest risk of death from these infections.  相似文献   

8.
Household humidification is widely practiced to combat dry indoor air. While the benefits of household humidification are widely perceived, its implications to the indoor air have not been critically appraised. In particular, ultrasonic humidifiers are known to generate fine particulate matter (PM). In this study, we first conducted laboratory experiments to investigate the size, quantity, and chemical composition of PM generated by an ultrasonic humidifier. The mass of PM generated showed a correlation with the total alkalinity of charge water, suggesting that CaCO3 is likely making a major contribution to PM. Ion chromatography analysis revealed a large amount of SO42− in PM, representing a previously unrecognized indoor source. Preliminary results of organic compounds being present in humidifier PM are also presented. A whole-house experiment was further conducted at an actual residential house, with five low-cost sensors (AirBeam) monitoring PM in real time. Operation of a single ultrasonic humidifier resulted in PM2.5 concentrations up to hundreds of μg m−3, and its influence extended across the entire household. The transport and loss of PM2.5 depended on the rate of air circulation and ventilation. This study emphasizes the need to further investigate the impact of humidifier operation, both on human health and on the indoor atmospheric chemistry, for example, partitioning of acidic and basic compounds.  相似文献   

9.
Biomass combustion for cooking and heating releases particulate matter (PM2.5) that contributes to household air pollution. Fuel and stove types affect the chemical composition of household PM, as does infiltration of outdoor PM. Characterization of these impacts can inform future exposure assessments and epidemiologic studies, but is currently limited. In this study, we measured chemical components of PM2.5 (water-soluble organic matter [WSOM], ions, black carbon, elements, organic tracers) in rural Chinese households using traditional biomass stoves, semi-gasifier stoves with pelletized biomass, and/or non-biomass stoves. We distinguished households using one stove type (traditional, semi-gasifier, or LPG/electric) from those using multiple stoves/fuels. WSOM concentrations were higher in households using only semi-gasifier or traditional stoves (31%-33%) than in those with exclusive LPG/electric stove (13%) or mixed stove use (12%-22%). Inorganic ions comprised 14% of PM in exclusive LPG/electric households, compared to 1%-5% of PM in households using biomass. Total PAH content was much higher in households that used traditional stoves (0.8-2.8 mg/g PM) compared to those that did not (0.1-0.3 mg/g PM). Source apportionment revealed that biomass burning comprised 27%-84% of PM2.5 in households using biomass. In all samples, identified outdoor sources (vehicles, dust, coal combustion, secondary aerosol) contributed 10%-20% of household PM2.5.  相似文献   

10.
Indoor air pollution (IAP) from biomass fuels contains high concentrations of health damaging pollutants and is associated with an increased risk of childhood pneumonia. We aimed to design an exposure measurement component for a matched case-control study of IAP as a risk factor for pneumonia and severe pneumonia in infants and children in The Gambia. We conducted co-located simultaneous area measurement of carbon monoxide (CO) and particles with aerodynamic diameter <2.5 microm (PM(2.5)) in 13 households for 48 h each. CO was measured using a passive integrated monitor and PM(2.5) using a continuous monitor. In three of the 13 households, we also measured continuous PM(2.5) concentration for 2 weeks in the cooking, sleeping, and playing areas. We used gravimetric PM(2.5) samples as the reference to correct the continuous PM(2.5) for instrument measurement error. Forty-eight hour CO and PM(2.5) concentrations in the cooking area had a correlation coefficient of 0.80. Average 48-h CO and PM(2.5) concentrations in the cooking area were 3.8 +/- 3.9 ppm and 361 +/- 312 microg/m3, respectively. The average 48-h CO exposure was 1.5 +/- 1.6 ppm for children and 2.4 +/- 1.9 ppm for mothers. PM(2.5) exposure was an estimated 219 microg/m3 for children and 275 microg/m3 for their mothers. The continuous PM(2.5) concentration had peaks in all households representing the morning, midday, and evening cooking periods, with the largest peak corresponding to midday. The results are used to provide specific recommendations for measuring the exposure of infants and children in an epidemiological study. PRACTICAL IMPLICATIONS: Measuring personal particulate matter (PM) exposure of young children in epidemiological studies is hindered by the absence of small personal monitors. Simultaneous measurement of PM and carbon monoxide suggests that a combination of methods may be needed for measuring children's PM exposure in areas where household biomass combustion is the primary source of indoor air pollution. Children's PM exposure in biomass burning homes in The Gambia is substantially higher than concentrations in the world's most polluted cities.  相似文献   

11.
Few measurements of exposure to secondhand smoke (SHS) in close proximity to a smoker are available. Recent health studies have demonstrated an association between acute (<2 h) exposures to high concentrations of SHS and increased risk of cardiovascular and respiratory disease. We performed 15 experiments inside naturally ventilated homes and 16 in outdoor locations, each with 2–4 non‐smokers sitting near a cigarette smoker. The smoker's and non‐smokers' real‐time exposures to PM2.5 from SHS were measured by using TSI SidePak monitors to sample their breathing zones. In 87% of the residential indoor experiments, the smoker received the highest average exposure to SHS, with PM2.5 concentrations ranging from 50–630 μg/m3. During the active smoking period, individual non‐smokers sitting within approximately 1 m of a smoker had average SHS exposures ranging from negligible up to >160 μg/m3 of PM2.5. The average incremental exposure of the non‐smokers was higher indoors (42 μg/m3, = 35) than outdoors (29 μg/m3, = 47), but the overall indoor and outdoor frequency distributions were similar. The 10‐s PM2.5 averages during the smoking periods showed great variability, with multiple high concentrations of short duration (microplumes) both indoors and outdoors.  相似文献   

12.
Improving air quality in indoor environments where people live is of importance to protect human health. In this systematic review, we assessed the effectiveness of personal-level use of air filtration units in reducing indoor particulate matters (PM) concentrations under real-world situations following systematic review guidelines. A total of 54 articles were included in the review, in which 20 randomized controlled/crossover trials that reported the changes in indoor fine PM (PM2.5) concentrations were quantitatively assessed in meta-analysis. Standardized mean differences (SMDs) were calculated for changes in indoor PM concentrations following air filtration interventions. Moderate-to-large reductions of 11%–82% in indoor PM2.5 concentrations were observed with SMD of −1.19 (95% CI: −1.50, −0.88). The reductions in indoor PM concentrations varied by geographical locations, filtration technology employed, indoor environmental characteristics, and air pollution sources. Most studies were graded with low-to-moderate risk of bias; however, the overall certainty of evidence for indoor PM concentration reductions was graded at very low level. Considering the effectiveness of indoor air filtration under practical uses, socio-economic disparities across study populations, and costs of air filter replacement over time, our results highlight the importance of reducing air pollution exposure at the sources.  相似文献   

13.
Qian Z  He Q  Kong L  Xu F  Wei F  Chapman RS  Chen W  Edwards RD  Bascom R 《Indoor air》2007,17(2):135-142
Diverse indoor combustion sources contribute to the indoor air environment. To evaluate the effect of these sources on human respiratory health, we examined associations between respiratory conditions and household factors in the 2360 children's fathers (mean = 38.4 years old) and associations between lung function and household factors in 463 primary school children (mean = 8.3 years old) from Wuhan, China. Factor analysis developed new uncorrelated 'factor' variables. Unconditional logistic regression models or linear regression models, controlling for important covariates, estimated the respiratory health effects. Coal smoke derived from home heating ('heating coal smoke') was associated with high adult reporting of persistent cough, persistent phlegm, and wheeze. Cooking coal smoke was associated with physician-diagnosed adult asthma and decreased forced vital capacity (FVC), and forced expiratory volume at 1 s (FEV(1)) in children. The presence of any home cigarette smoker was associated with more reports of persistent cough, persistent phlegm, cough with phlegm, and bronchitis. Our study suggests that in Wuhan, there may be independent respiratory health effects of different indoor combustion sources and their exposure factors for these study populations. PRACTICAL IMPLICATIONS: We conclude that multiple indoor air pollution sources could have adverse respiratory health effects on both children and middle-aged men in the city of Wuhan, China. These results may have implications for the Wuhan local government, the Chinese government, or other related organizations in efforts on protecting public health through regulation of indoor air pollution from indoor combustion sources.  相似文献   

14.
Little is known whether parent's indoor environment quality (IEQ)-related symptoms or health perceptions influence the risk of self- or parent-reported symptoms in their children. We assessed (i) the association of parents’ IEQ-related symptoms with IEQ-related symptoms in their children at school and (ii) whether parental IEQ-related health worry increases the risk for children's symptoms. We used two Finnish studies: a national, population-based survey of indoor air and related health problems (n = 611 parents) and a subset of survey for all primary school pupils (grade 3–6) and their parents in Helsinki, which also included school IEQ-related symptoms reported by children (n = 1617 parent-child dyads). In the school survey, parent's own symptoms increased strongly their reporting of their children's symptoms at school (aOR 4.0, 95% CI 2.7–6.0 for parents experiencing a lot of symptoms) and also symptoms reported by the child itself (aOR 2.2, 95% CI 1.5–3.1). Similar, but slightly weaker associations were seen with parental IEQ-related health worries. Results remained unchanged when adjusted for the IEQ of school buildings or parental and children's allergic diseases. Similar associations were seen in the national survey between parent's symptoms at work and child's symptoms at school. The results suggest that parents’ health perceptions may increase the reporting of children's IEQ-related symptoms even more than is typically seen for many indoor air contaminants.  相似文献   

15.
Y. Yoda  K. Tamura  M. Shima 《Indoor air》2017,27(5):955-964
Endotoxins are an important biological component of particulate matter and have been associated with adverse effects on human health. There have been some recent studies on airborne endotoxin concentrations. We collected fine (PM2.5) and coarse (PM10‐2.5) particulate matter twice on weekdays and weekends each for 48 hour, inside and outside 55 homes in an urban city in Japan. Endotoxin concentrations in both fractions were measured using the kinetic Limulus Amebocyte Lysate assay. The relationships between endotoxin concentrations and household characteristics were evaluated for each fraction. Both indoor and outdoor endotoxin concentrations were higher in PM2.5 than in PM10‐2.5. In both PM2.5 and PM10‐2.5, indoor endotoxin concentrations were higher than outdoor concentrations, and the indoor endotoxin concentrations significantly correlated with outdoor concentrations in each fraction (R2=0.458 and 0.198, respectively). Indoor endotoxin concentrations in PM2.5 were significantly higher in homes with tatami or carpet flooring and in homes with pets, and lower in homes that used air purifiers. Indoor endotoxin concentrations in PM10‐2.5 were significantly higher in homes with two or more children and homes with tatami or carpet flooring. These results showed that the indoor endotoxin concentrations were associated with the household characteristics in addition to outdoor endotoxin concentrations.  相似文献   

16.
Dutta A  Mukherjee B  Das D  Banerjee A  Ray MR 《Indoor air》2011,21(2):165-176
This study aims to investigate whether indoor air pollution (IAP) from biomass fuel use was associated with hypertension, platelet hyperactivity, and elevated levels of oxidized low-density lipoprotein (oxLDL) and anticardiolipin antibody (aCL). We enrolled 244 biomass fuel-using (median age 34 year) and 236 age-matched control women who cooked with liquefied petroleum gas (LPG). Enzyme-linked immunosorbent assay was used to measure oxLDL in plasma and aCL in serum, flow cytometry for P-selectin expression on platelet and reactive oxygen species (ROS) generation by leukocytes, aggregometry for platelet aggregation, spectrophotometry for superoxide dismutase (SOD) in erythrocytes, and laser photometer for particulate matter <10 and 2.5 μm in diameter (PM(10) and PM(2.5), respectively) in cooking areas. Biomass users had three times more particulate pollution in kitchen, had higher prevalence of hypertension (29.5 vs. 11.0% in control, P < 0.05), elevated oxLDL (170.6 vs. 45.9 U/l; P < 0.001), platelet P-selectin expression (9.1% vs. 2.4%), platelet aggregation (23.2 vs. 15.9 Ohm), raised aCL IgG (28.7% vs. 2.1%), IgM (8.6% of vs. 0.4%), and ROS (44%) but depleted (13%) SOD. After controlling potential confounders, the changes were positively associated with PM(10) and PM(2.5) in indoor air, suggesting a positive association between IAP and increased cardiovascular risk. PRACTICAL IMPLICATIONS: The study showing high risk of developing cardiovascular diseases (CVD) among poor, underprivileged women in their reproductive ages in rural India is important from public health perspectives. It may motivate the government and the regulatory agencies of the country to take a serious note of the indoor air pollution (IAP) from biomass fuel use as it threatens the health of millions of women, children, and the elderly who mostly stay indoor. We hope the findings will strengthen the demand for setting up a standard for indoor air quality in the country in the line of national ambient air quality standard. The findings may also inspire the authorities to take measures for the reduction in IAP by improving housing, kitchen ventilation, and cook stoves. Moreover, the parameters used in this study can be utilized for large, population-based studies to identify women at a higher risk of developing CVD so that medical intervention can be taken at the formative stage of a disease.  相似文献   

17.
Burning solid fuels to fulfill daily household energy needs results in chronic exposure to household air pollution (HAP), which is among the world's greatest health risks. This paper presents the results of a cross‐sectional study of cookstove usage, fuel consumption, and indoor PM2.5 concentrations in rural and urban Honduran homes cooking with the Envirofit HM‐5000 metal plancha stove (n = 32) as compared to control households using baseline cooking technologies (n = 33). Temperature‐based stove usage measurements showed high HM‐5000 acceptance, with significant displacement of the traditional cookstoves at both the urban (99%, P < .05) and rural study sites (75%, P < .05). However, longer‐term usage data collected in peri‐urban households showed that participants cooked on the HM‐5000 more frequently during the 3‐day monitoring period than during the following 3 weeks. Average indoor PM2.5 was 66% lower in HM‐5000 households as compared to control households (P < .05). Lower indoor PM2.5 concentrations observed in participant homes as compared to control households, supported by high usage and traditional stove displacement, suggest the potential for the HM‐5000 to yield health improvements in adopting Honduran households.  相似文献   

18.
Hairdressers are exposed to particulate matter (PM), a known air pollutant linked to adverse health effects. Still, studies on occupational PM exposures in hair salons are sparse. We characterized indoor air PM concentrations in three salons primarily serving an African/African American (AA) clientele, and three Dominican salons primarily serving a Latino clientele. We also assessed the performance of low-cost sensors (uRAD, Flow, AirVisual) by comparing them to high-end sensors (DustTrak) to conduct air monitoring in each salon over 3 days to quantify work shift concentrations of PM2.5, respirable PM (RPM), and PM10. We observed high spatial and temporal variability in 30-min time-weighted average (TWA) RPM concentrations (0.18–5518 μg/m3). Readings for the uRAD and AirVisual sensors were highly correlated with the DustTrak (R2 = 0.90–0.99). RPM 8-hour TWAs ranged from 18 to 383 µg/m3 for AA salons, and 9–2115 µg/m3 for Dominican salons. Upper 95th percentiles of daily RPM exposures ranged from 439 to 2669 µg/m3. The overall range of 30-min TWA PM2.5 and PM10 concentrations was 0.13–5497 and 0.36-,541 μg/m3, respectively. Findings suggest that hairdressers could be overexposed to RPM during an 8-hour shift. Additional comprehensive monitoring studies are warranted to further characterize temporal and spatial variability of PM exposures in this understudied occupational population.  相似文献   

19.
We measured particulate matter (PM), acrolein, and other indoor air contaminants in eight visits to grocery stores in California. Retail stores of other types (hardware, furniture, and apparel) were also sampled on additional visits. Based on tracer gas decay data, most stores had adequate ventilation according to minimum ventilation rate standards. Grocery stores had significantly higher concentrations of acrolein, fine and ultrafine PM, compared to other retail stores, likely attributable to cooking. Indoor concentrations of PM2.5 and acrolein exceeded health guidelines in all tested grocery stores. Acrolein emission rates to indoors in grocery stores had a mean estimate about 30 times higher than in other retail store types. About 80% of the indoor PM2.5 measured in grocery stores was emitted indoors, compared to only 20% for the other retail store types. Calculations suggest a substantial increase in outdoor air ventilation rate by a factor of three from current level is needed to reduce indoor acrolein concentrations. Alternatively, acrolein emission to indoors needs to be reduced 70% by better capturing of cooking exhaust. To maintain indoor PM2.5 below the California annual ambient standard of 12 μg/m3, grocery stores need to use air filters with an efficiency rating higher than the MERV 8 air filters commonly used today.  相似文献   

20.
The aim of this study was to explore the association between the building-related occupants’ reported health symptoms and the indoor pollutant concentrations in a sample of 148 office rooms, within the framework of the European OFFICAIR research project. A large field campaign was performed in 37 office buildings among eight countries, which included (a) 5-day air sampling of volatile organic compounds (VOCs), aldehydes, ozone, and NO2 (b) collection of information from 1299 participants regarding their personal characteristics and health perception at workplace using online questionnaires. Stepwise and multilevel logistic regressions were applied to investigate associations between health symptoms and pollutant concentrations considering personal characteristics as confounders. Occupants of offices with higher pollutant concentrations were more likely to report health symptoms. Among the studied VOCs, xylenes were associated with general (such as headache and tiredness) and skin symptoms, ethylbenzene with eye irritation and respiratory symptoms, a-pinene with respiratory and heart symptoms, d-limonene with general symptoms, and styrene with skin symptoms. Among aldehydes, formaldehyde was associated with respiratory and general symptoms, acrolein with respiratory symptoms, propionaldehyde with respiratory, general, and heart symptoms, and hexanal with general SBS. Ozone was associated with almost all symptom groups.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号