 共查询到20条相似文献,搜索用时 15 毫秒
1.
The adsorption and desorption of volatile organic compounds (VOCs) in relation to material surfaces were conducted to control indoor air quality. The VOC removal performance of building materials using sorption effects was validated in cases related to poor indoor air quality that occurred during non-ventilation periods during intermittent-ventilation situations. The objective of this investigation is to present the contaminant removal efficiency and practicality of a prototype air cleaner which uses sorption effects. Toluene and formaldehyde were used as pollutant sources and were continuously emitted into the test chamber. Effects due to the number of sorption units, operation time and mode of contaminant removal performance were examined. The sorption materials evaluated in this investigation were a porous material, zeolite, pumice stone and hydro-corn. As a result of the experiments, zeolite exhibited relatively high contaminant removal efficiency with toluene, and zeolite and the porous material exhibited high removal efficiency with formaldehyde for both one-cycle and two-cycle sorption modes. Moreover, significant removal performances were observed in the numerical analysis of the continuous-operation mode.  相似文献   

2.
This paper employs the state space method to characterize transportation of indoor gaseous pollutant in steady airflow field. From the differential equations governing contaminant transportation in space, the state space equation for transportation is proposed and the analytical solution is obtained. In the method, the matrix covering hologram of the transportation is derived. The state space equation is validated with the analytic solution for the case of the simultaneous transportation of the pollution for piston flow. Similarly, the concentration from the proposed method for a 2-D case also agrees well with the result from CFD method based on the experimentally validated flow field. Based upon the analytic solution of the state equation, it is easily known that the influence of the initial concentration distribution and the pollution source on the concentration at the specific point. In addition, assisted by Chen’s zero equation turbulence model [1], the concentration field for a 3-D case is simulated by the presented method. It is found that there exists a regular stage at which the relative effect of the initial concentration distribution and the source on the concentration field will not change with time.  相似文献   

3.
Sekhar SC  Tham KW  Cheong KW 《Indoor air》2003,13(4):315-331
An integrated indoor air quality (IAQ)-energy audit methodology has been developed in this study in Singapore, which provides a rigorous and systematic method of obtaining the status-quo assessment of an 'IAQ signature' in a building. The methodology entails a multi-disciplinary model in obtaining measured data pertaining to different dimensions within the built environment such as the physical, chemical, biological, ventilation, and occupant response characteristics. This paper describes the audit methodology and presents the findings from five air-conditioned office buildings in Singapore. The research has also led to the development of an indoor pollutant standard index (IPSI), which is discussed in this paper. Other performance indicators such as, the ventilation index and the energy index as well as the building symptom index (BSI) are also presented and discussed in the context of an integrated approach to IAQ and energy. Several correlation attempts were made on the various symptoms, indoor air acceptability, thermal comfort, BSI and IPSI, and while BSI values are found to correlate among them as well as with IAQ and THERMAL COMFORT acceptability, no such correlation was observed between BSI and IPSI. This would suggest that the occupants' perception of symptoms experienced as well as environmental acceptability is quite distinct from IAQ acceptability determined from empirical measurements of indoor pollutants, which reinforces the complex nature of IAQ issues.  相似文献   

4.
In recognition of the fact that building materials are an important source of indoor radon, second only to soil, surface radon exhalation fluxes have been extensively measured from the samples of these materials. Based on this flux data, several researchers have attempted to predict the inhalation dose attributable to radon emitted from walls and ceilings made up of these materials. However, an important aspect not considered in this methodology is the enhancement of the radon flux from the wall or the ceiling constructed using the same building material. This enhancement occurs mainly because of the change in the radon diffusion process from the former to the latter configuration. To predict the true radon flux from the wall based on the flux data of building material samples, we now propose a semi-empirical model involving radon diffusion length and the physical dimensions of the samples as well as wall thickness as other input parameters. This model has been established by statistically fitting the ratio of the solution to radon diffusion equations for the cases of three-dimensional cuboidal shaped building materials (such as brick, concrete block) and one dimensional wall system to a simple mathematical function. The model predictions have been validated against the measurements made at a new construction site. This model provides an alternative tool (substitute to conventional 1-D model) to estimate radon flux from a wall without relying on 226Ra content, radon emanation factor and bulk density of the samples. Moreover, it may be very useful in the context of developing building codes for radon regulation in new buildings.  相似文献   

5.
Although negative air ionizer is commonly used for indoor air cleaning, few studies examine the concentration gradient of negative air ion (NAI) in indoor environments. This study investigated the concentration gradient of NAI at various relative humidities and distances form the source in indoor air. The NAI was generated by single-electrode negative electric discharge; the discharge was kept at dark discharge and 30.0 kV. The NAI concentrations were measured at various distances (10-900 cm) from the discharge electrode in order to identify the distribution of NAI in an indoor environment. The profile of NAI concentration was monitored at different relative humidities (38.1-73.6% RH) and room temperatures (25.2+/-1.4 degrees C). Experimental results indicate that the influence of relative humidity on the concentration gradient of NAI was complicated. There were four trends for the relationship between NAI concentration and relative humidity at different distances from the discharge electrode. The changes of NAI concentration with an increase in relative humidity at different distances were quite steady (10-30 cm), strongly declining (70-360 cm), approaching stability (420-450 cm) and moderately increasing (560-900 cm). Additionally, the regression analysis of NAI concentrations and distances from the discharge electrode indicated a logarithmic linear (log-linear) relationship; the distance of log-linear tendency (lambda) decreased with an increase in relative humidity such that the log-linear distance of 38.1% RH was 2.9 times that of 73.6% RH. Moreover, an empirical curve fit based on this study for the concentration gradient of NAI generated by negative electric discharge in indoor air was developed for estimating the NAI concentration at different relative humidities and distances from the source of electric discharge.  相似文献   

6.
The performance of an air cleaner is evaluated by the clean air delivery rate (CADR), which is defined as the measure of the delivery of contaminant-free air. Herein, we conducted comparative analyses of various particulate air filters with various collection efficiencies. We installed each filter in identical commercial air cleaners to determine the effects of the collection efficiency on the CADR. Three different filters (E11, E12, and H13 classes) were prepared to determine the effects of the filter collection efficiency and pressure drop on the air cleaner performance (ie, the CADR). Based on experimental data, filters E11 and E12 had similar CADRs and flow rates. However, filter H13, which had the highest collection efficiency and the lowest flow rate, had the lowest CADR. This indicates that even if a filter with higher collection efficiency is installed in an air cleaner, the larger pressure drop causes a reduction in the air flow rate. The CADR value is widely distributed for a flow rate range for commercially available models; however, the collection efficiencies for most air cleaners on the market lie in a narrow range. Therefore, the flow rate has the most direct impact on the performance of a commercial air cleaner.  相似文献   

7.
This paper describes the present state and the changes in indoor air pollution levels by Volatile Organic Compounds (VOCs) in houses in Japan, as revealed through measurements of indoor VOC concentrations and investigations on the actual conditions in the residential environment by means of a questionnaire survey covering a total of more than 10,000 newly built houses over six years (from 2000 to 2005). The VOCs initially measured were formaldehyde, toluene, xylene, and ethylbenzene, followed by the subsequent inclusion of styrene and acetaldehyde.  相似文献   

8.
This paper presents a case to investigate the effect of partitions in an office on the performance of under floor air supply ventilation system via computational fluid dynamics. The assessment is in terms of thermal comfort and indoor air quality with the use of a validated computer model. The results indicate that the partitions may significantly affect airflow and performance of a under floor air supply ventilation system. In particular, the presence of a gap above the partition wall is able to improve air distribution owing to less air re-circulation in the upper zone. Its effect on thermal comfort and indoor air quality indicators are evaluated.  相似文献   

9.
Ultraviolet germicidal irradiation (UVGI) uses UVC radiation produced by low pressure mercury vapor lamps to control biological air contaminants. Ambient air velocity and temperature have a strong effect on lamp output by influencing the lamp surface cold spot temperature. In-duct UVGI systems are particularly susceptible to ambient effects due to the range of velocity and temperature conditions they may experience. An analytical model of the effect of ambient conditions on lamp surface temperature was developed for three common lamp types in cross flow from a convective–radiative energy balance assuming constant surface temperature. For one lamp type, a single tube standard output lamp, UVC output and cold spot temperature data were obtained under typical in-duct operating conditions. Over an ambient temperature range of 10–32.2 °C and an air velocity range of 0–3.25 m/s, measured cold spot temperature varied from 12.7 to 41.9 °C and measured lamp output varied by 68% of maximum. Surface temperatures predicted by the heat transfer model were 6–17 °C higher than corresponding measured cold spot temperatures, but were found to correlate well with cold spot temperature via a two-variable linear regression. When corrected using this relationship, the simple model predicted the cold spot temperature within 1 °C and lamp UVC output within ±5%. To illustrate its practical use, the calibrated lamp model was employed in a simulation of the control of a contaminant in a single-zone ventilation system by an in-duct UVGI device. In this example, failure to account for the impact of ambient condition effects resulted in under-prediction of average space concentration by approximately 20% relative to a constant output system operating at maximum UVC output.  相似文献   

10.
To analyze the thermal performance and indoor air quality (IAQ) in building simultaneously and quickly, we have developed an integrated modeling tool to simulate the dynamic indoor multi-parameters distributions and concentrations. The tool can take the parameters including indoor temperature, indoor humidity, and pollutant concentrations (e.g., volatile organic compounds (VOC) CO2, particulate matter (PM)), as well as the heating/cooling load of heating, ventilating, and air-conditioning (HVAC) system into account. It couples a new zonal approach based on room air age. This paper presents the basic concept and flow chart in developing the modeling tool, and demonstrates the tool's application in a hypothetical health care building. The tool could be used for design of HVAC system with IAQ control devices and for the simultaneous analysis of thermal performance and IAQ in buildings.  相似文献   

11.
Theatres are the most complex of all auditorium structures environmentally. They usually have high heat loads, which are of a transient nature as audiences come and go, and from lighting which changes from scene to scene, and they generally have full or nearly full occupancy. Theatres also need to perform well acoustically, both for the spoken word and for music, and as sound amplification is less used than in other auditoria, background noise control is critically important. All these factors place constraints on the ventilation design, and if this is poor, it can lead to the deterioration of indoor air quality and thermal comfort. To analyse the level of indoor air quality and thermal comfort in a typical medium-sized mechanically ventilated theatre, and to identify where improvements could typically be made, a comprehensive post-occupancy evaluation study was carried out on a theatre in Belgrade. The evaluation, based on the results of monitoring (temperature, relative humidity, CO2, air speed and heat flux) and modelling (CFD), as well as the assessment of comfort and health as perceived by occupants, has shown that for most of the monitored period the environmental parameters were within the standard limits of thermal comfort and IAQ. However, two important issues were identified, which should be borne in mind by theatre designers in the future. First, the calculated ventilation rates showed that the theatre was over-ventilated, which will have serious consequences for its energy consumption, and secondly, the displacement ventilation arrangement employed led to higher than expected complaints of cold discomfort, probably due to cold draughts around the occupants’ feet.  相似文献   

12.
A case of suspected indoor ammonia contamination from concrete was investigated in an airline company office in Beijing. A standardized questionnaire on indoor environment perceptions, medical symptoms and psychosocial work environment was distributed to all staff, and compared with a reference group of office workers from the same company in Stockholm. Temperature, relative humidity, formaldehyde, volatile organic compounds (VOC), ammonia, and carbon dioxide were measured both in Beijing and Stockholm. In Beijing mould and bacteria were also measured. Totally 95% (N = 14) participated. The Beijing staff reported a higher rate of complaints regarding poor work satisfaction, and work stress as compared to the Stockholm reference group. In the total material (N = 203) the psychosocial environment was related to general symptoms (headache and tiredness) but not odour perception or mucous membrane symptoms. Controlling for age, smoking habits, and psychosocial work environment the Beijing staff had more complaints on unpleasant odour and mucous membrane symptoms. An increased indoor concentration of ammonia (3–6 ppm) and benzene (26.8 μg/m3) was measured in the indoor air in the Beijing office, as compared to the office in Stockholm (<0.1 ppm ammonia and 0.4 μg/m3 benzene). The ammonia contamination in the Beijing office was confirmed, the probable source being additives in the concrete. The ammonia level was well below the Swedish threshold limit values (TLV) (25 ppm). In addition the exposure to benzene, an indicator of traffic exhaust pollution was high both indoors and outdoors in Beijing, possible related to increased levels of odour complaints and mucous membrane irritation.  相似文献   

13.
Both high and low indoor relative humidity (RH) directly impact Indoor Air Quality (IAQ), an important school health concern. Prior school studies reported a high prevalence of mold, roaches, and water damage; however, few examined associations between modifiable classroom factors and RH, a quantitative indicator of dampness. We recorded RH longitudinally in 134 North Carolina classrooms (n = 9066 classroom‐days) to quantify the relationships between modifiable classroom factors and average daily RH below, within, or above levels recommended to improve school IAQ (30–50% or 30–60% RH). The odds of having high RH (>60%) were 5.8 [95% Confidence Interval (CI): 2.9, 11.3] times higher in classrooms with annual compared to quarterly heating, ventilating, and air‐conditioning (HVAC) system maintenance and 2.5 (95% CI: 1.5, 4.2) times higher in classrooms with HVAC economizers compared to those without economizers. Classrooms with direct‐expansion split systems compared to chilled water systems had 2.7 (95% CI: 1.7, 4.4) times higher odds of low RH (<30%). When unoccupied, classrooms with thermostat setbacks had 3.7 (95% CI: 1.7, 8.3) times the odds of high RH (>60%) of those without setbacks. This research suggests actionable decision points for school design and maintenance to prevent high or low classroom RH.  相似文献   

14.
Abstract This study deals with the modeling of air pollution in apartments from laboratory measurements of source strengths, using formaldehyde and Total Volatile Organic Compounds (TVOCs) as model pollutants. The sources in two test apartments were grouped into two: building-related sources and occupant-related sources. The measured source strengths and ventilation rates were used for the prediction of concentrations expected in the apartments. These predictions were compared to measurements in the apartment over 12 months. The conclusions were that the model predictions based on emission rates measured in the laboratory can be used to predict the long-term concentration of the two model pollutants in the apartments. Considering the measured differences in ventilation between the apartments, an occupant emission rate of between 0.2 and 0.3 mg/h/kg body weight could be estimated. Based on previous suggested limits of acceptable exposures of humans to VOCs, an acceptable average emission rate of VOCs from building materials in general was estimated to be about 30 (μ/m2/h. The modeling showed that during the first 200 days, building materials dominated the emissions. After this, sources relating to the occupants dominated. On average about half of the VOC pollution originated from the building materials.  相似文献   

15.
Previous studies have found that classrooms are often inadequately ventilated, with the resultant increased risk of negative impacts on the pupils. This paper describes a series of field measurements that investigated the indoor air quality, thermal comfort and acoustic performance of nine recently built secondary schools in England. The most significant conclusion is that the complex interaction between ventilation, thermal comfort and acoustics presents considerable challenges for designers. The study showed that while the acoustic standards are demanding it was possible to achieve natural ventilation designs that met the criteria for indoor ambient noise levels when external noise levels were not excessive. Most classrooms in the sample met the requirement of limiting the daily average CO2 concentration to below 1500 ppm but just a few met the need to readily provide 8 l/s per person of fresh air under the easy control of the occupants. It would seem that the basic requirement of 1500 ppm of CO2 is achieved as a consequence of the window areas being just sufficient to provide the minimum of 3 l/s per person at low and intermittent occupancy. Thermal comfort in the monitored classrooms was mostly acceptable but temperatures tended to be much higher in practice than the design assumed.  相似文献   

16.
Unlike commercial premises, the indoor air quality of residences is more dynamic, uncontrolled, and prone to human behavioral changes. In consequence, measuring the health benefit gains derived from improving indoor air quality in residences is more complicated. To overcome this, a human thermal comfort model was first integrated with indoor microenvironment models, and subsequently linked with appropriate concentration-response and economic data for estimating the economic benefit gains derived from improving indoor air quality in residences for an adult and an elderly person. In this study, the development of the model is illustrated by using a typical residential apartment locating at the worst air quality neighborhood in Hong Kong and the daily weather profiles between 2002 and 2006. Three types of personal intervention measures were examined in the study: (i) using air cleaner in residence, (ii) changing time spent in residence, and (iii) relocating to a better air quality neighborhood. Our results revealed that employing air cleaners with windows closed in residence throughout the entire year was the most beneficial measure as it could provide the greatest annual health benefit gains. It would give a maximum of HK$2072 in 5-year cumulative benefit gain for an adult and HK$1700 for an elderly person. Employing air cleaners with windows closed in only cool season (October through March) could give the highest marginal return per dollar spent. The benefit gains would become smaller when windows were opened to a greater extent. By contrast, relocating to a better air quality neighborhood and changing the time spent in residence did not appeal to be beneficial intervention measures.  相似文献   

17.
Air flow and the associated indoor carbon dioxide concentrations have been extensively monitored in 62 classrooms of 27 naturally ventilated schools in Athens, Greece. The specific ventilation patterns as well as the associated carbon dioxide concentrations, before, during and after the teaching period are analysed in detail. During the teaching period, only 23% of the measured classrooms presented a flow rate higher than the recommended value of 8 l/p/s while the mean daily fluctuation was close to 40%. About, 52% of the classrooms presented a mean indoor CO2 concentration higher than 1000 ppm. The specific experimental data have been compared against existing ventilation rates and carbon dioxide concentrations using published information from 287 classrooms of 182 naturally ventilated schools and 900 classrooms from 220 mechanically ventilated schools. The relation between the air flow rates and the corresponding indoor carbon dioxide is analysed and then compared to the existing data from naturally and mechanically ventilated schools. It is found that all three data sets present a CO2 concentration equal to 1000 ppm for air flows around 8 l/p/s. Specific adaptive actions to improve the indoor environmental quality have been recorded and the impact of indoor and ambient temperatures as well as of the carbon dioxide concentration on window opening is analysed in detail. A clear relation is found, between the indoor temperature at which the adapting action takes place and the resulting air flow rate. In parallel, a statistically significant relation between window opening and the indoor–outdoor temperature difference has been established.  相似文献   

18.
A randomized controlled trial was carried out to measure the impact of an intervention on ventilation, indoor air contaminants, and asthma symptoms of children. Eighty‐three asthmatic children living in low‐ventilated homes were followed over 2 years. Several environmental parameters were measured during the summer, fall, and winter. The children were randomized after Year 1 (43 Intervention; 40 Control). The intervention included the installation of either a Heat Recovery Ventilator (HRV) or Energy Recovery Ventilator (ERV). During the fall and winter seasons, there was a significant increase in the mean ventilation rate in the homes of the intervention group. A statistically significant reduction in mean formaldehyde, airborne mold spores, toluene, styrene, limonene, and α‐pinene concentrations was observed in the intervention group. There was no significant group difference in change in the number of days with symptoms per 14 days. However, there was a significant decrease in the proportion of children who experienced any wheezing (≥1 episode) and those with ≥4 episodes in the 12‐month period in the intervention group. This study indicates that improved ventilation reduces air contaminants and may prevent wheezing. Due to lack of power, a bigger study is needed.  相似文献   

19.
Portable air cleaners are increasingly used in polluted areas in an attempt to reduce human exposure; however, there has been limited work characterizing their effectiveness at reducing exposure. With this in mind, we recruited forty-three children with asthma from suburban Shanghai and deployed air cleaners (with HEPA and activated carbon filters) in their bedrooms. During both 2-week filtration and non-filtration periods, low-cost PM2.5 and O3 air monitors were used to measure pollutants indoors, outdoors, and for personal exposure. Indoor PM2.5 concentrations were reduced substantially with the use of air cleaners, from 34 ± 17 to 10 ± 8 µg/m3, with roughly 80% of indoor PM2.5 estimated to come from outdoor sources. Personal exposure to PM2.5 was reduced from 40 ± 17 to 25 ± 14 µg/m3. The more modest reductions in personal exposure and high contribution of outdoor PM2.5 to indoor concentrations highlight the need to reduce outdoor PM2.5 and/or to clean indoor air in multiple locations. Indoor O3 concentrations were generally low (mean = 8±4 ppb), and no significant difference was seen by filtration status. The concentrations of pollutants and the air cleaner effectiveness were highly variable over time and across homes, highlighting the usefulness of real-time air monitors for understanding individual exposure reduction strategies.  相似文献   

20.
Monitoring of human reactions to the emission of formaldehyde and volatile organic compounds (VOC) from four commonly used building materials was carried out. The building materials were: a painted gypsum board, a rubber floor, a nylon carpet, and a particle board with an acid-curing paint. The exposures were performed in climate chambers. The air quality was quantified on the decipol scale by a trained panel, measurements of formaldehyde and VOC being performed simultaneously. The irritating potency of the materials was measured by a mouse bioassay. The VOC measurements showed several malodorants and irritants. Some abundant VOC identified in the head-space analyses were absent in the climate chamber air. The rubber floor and the nylon carpet exhibited a marked increase in decipols compatible with a number of odorous VOC identified in the air. A high formaldehyde concentration (minimum 743μg/m3) was measured for the particle board coated with an acid-curing paint. This was not reflected by a corresponding relatively high decipol value but a long-lasting irritating potency was observed in the mouse bioassay. TVOC sampled on Tenax and expressed in mass per volume as well as in molar concentration, and decipol evaluation both have limitations and should be used with caution as indicators of (perceived) indoor air quality. Eye irritation expressed by means of the eye index reflecting the tear film quality index (comprised of break-up time, foam formation, thickness of the precorneal lipid layer of the tear film, and epithelial damage) was found to be insensitive to formaldehyde and a VOC mixture but sensitive to TVOC concentrations of 1–2 mg/m3. Lipophilic VOC may be the cause of reduced tear film quality by destabilization of the lipid multilayer of the tear film.  相似文献   