首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Sustainable operation of an anaerobic sewage sludge digester requires the effective shuttling of carbon from complex organic material to methane gas. The accumulation of intermediates and metabolic products such as volatile fatty acids and hydrogen gas not only reveal inefficiency within the digestion process, but can be detrimental to reactor operation at sufficiently high levels. Eight anaerobic digesters (1 mesophilic and 7 thermophilic) were operated in order to determine the effect of steady-state digestion temperature on the operational stability and performance of the digestion process. Replicate reactors operated at 57.5 degrees C, the highest temperature studied, were prone to accumulation of volatile fatty acids (4052 and 3411 mg/L as acetate) and gaseous hydrogen. Reactors operated at or below 55 degrees C showed no such accumulation of intermediate metabolites. Overall methanogenesis was also greatly reduced at 57.5 degrees C (0.09 L CH4/g VS fed) versus optimal methane formation at 53 degrees C (0.40 L CH4/g VS fed). Microbial community assessment and free energy calculations suggest that the accumulation of fatty acids and hydrogen, and relatively poor methanogenic performance at 57.5 degrees C are likely due to temperature limitations of thermophilic aceticlastic methanogens.  相似文献   

2.
A thermal hydrolysis pilot plant with direct steam injection heating was designed and constructed. In a first period the equipment was operated in batch to verify the effect of sludge type, pressure and temperature, residence time and solids concentration. Optimal operation conditions were reached for secondary sludge at 170 degrees C, 7 bar and 30 minutes residence time, obtaining a disintegration factor higher than 10, methane production increase by 50% and easy centrifugation In a second period the pilot plant was operated working with continuous feed, testing the efficiency by using two continuous anaerobic digester operating in the mesophilic and thermophilic range. Working at 12 days residence time, biogas production increases by 40-50%. Integrating the energy transfer it is possible to design a self-sufficient system that takes advantage of this methane increase to produce 40% more electric energy.  相似文献   

3.
Anaerobic digestion (AD) is the preferred option to stabilize sludge. However, the rate limiting step of solids hydrolysis makes it worth modifing the conventional mesophilic AD in order to increase the performance of the digester. The main strategies are to introduce a hydrolysis pre-treatment, or to modify the digestion temperature. Among the different pre-treatment alternatives, the thermal hydrolysis (TH) at 170 degrees C for 30 min, and the ultrasounds pre-treatment (US) at 30 kJ/kg TS were selected for the research, while for the non-conventional anaerobic digestion, the thermophilic (TAD) and the two-stage temperature phased AD (TPAD) were considered. Four pilot plants were operated, with the same configuration and size of anaerobic digester (200 L, continuously fed). The biogas results show a general increase compared to the conventional digestion, being the highest production per unit of digester for the process combining the thermal pre-treatment and AD (1.4 L biogas/L digester day compared to the value of 0.26 obtained in conventional digesters). The dewaterability of the digestate became enhanced for processes TH + AD and TPAD when compared with the conventional digestate, while it became worse for processes US + AD and TAD. In all the research lines, the viscosity in the digester was smaller compared to the conventional (which is a key factor for process performance and economics), and both thermal pre-treatment and thermophilic digestion (TAD and TPAD) assure a pathogen free digestate.  相似文献   

4.
With several advantages over the conventional mesophilic anaerobic digestion, such as better sludge quality and higher biogas production, thermophilic anaerobic digestion is regarded as a promising alternative for sludge digestion. Primary and activated sludges are complex materials, and historically, analysis of kinetics has been largely on whole sludge, without analysis of individual components. This paper analyses relative digestion kinetics of pure substrates designed to target main stages of sludge digestion under thermophilic and mesophilic conditions. Hydrolysis rate of cellulose was significantly influenced by temperature with hydrolysis coefficients of--at 55 degrees C (0.7 +/- 0.1 day(-1)), 60 degrees C (0.8 +/- 0.2 day(-1)), 65 degrees C (1.1 +/- 0.2 day(-1)) and 70 degrees C (1.2 +/- 0.2 day(-1)) over 38 degrees C (0.4 +/- 0.1 day(-1)). This strongly follows the Arrhenius relationship, with an activation energy (E(A)) of 31 +/- 4 kJ mol(-1), corresponding to an increase of 1.5x for each 10 degrees C of temperature increase. Glucose uptake was rapid with a wide variety of fermentation products detected under mesophilic conditions, while uptake was slower under thermophilic conditions with acetate and propionate being dominant products. Propionate acetogenesis and acetate-utilizing methanogenesis kinetics were not influenced by temperatures. Hydrolysis is widely regarded as a rate-limiting step in sludge digestion, thus improvements in hydrolysis rates as measured during this study have the potential for significant improvements in overall apparent sludge digestion rates.  相似文献   

5.
In order to characterize the nitrogen conversion characteristics in a thermophilic aerobic digestion (TAD) system, a laboratory study has been conducted with the analysis of effluent gas and microbial community in the sludge samples. The lab TAD system was operated with HRT of 3 days and 60 degrees C. Based on the nitrogen mass balance, it has been found that about 2/3 of the daily load of nitrogen was converted to the gaseous form of nitrogen whereas cellular transformation and unmetabolized nitrogen accounted for about 1/3. Among the gaseous nitrogen transformation, significant amount of influent nitrogen had been converted to N2 gas (29% of influent N) and N2O (9% of influent N). Ammonia conversion was only 28% of influent N. The detection of N2O gas is a clear indication of the biological nitrogen reduction process in the thermophilic aerobic digester. No conclusive evidence for the existence of aerobic deammonification has been found. The microbial community analysis showed that thermophilic bacteria such as Bacillus thermocloacae, Bacillus sp. and Clostridial groups dominated in this TAD reactor. The diverse microbial community in TAD sludge may play an important role in removing both strong organics and nitrogen from piggery waste.  相似文献   

6.
The City of Los Angeles, Bureau of Sanitation, has implemented thermophilic anaerobic sludge digestion at the Hyperion and Terminal Island Treatment Plants (HTP and TITP). A two-stage continuous-batch process was established at HTP, while a single-stage sequencing batch process was established at TITP. This was to evaluate compliance with the Class A pathogen reduction requirements of U.S. EPA 40 CFR Part 503. A rapid increase of the digester temperature at TITP from 57.5 to 65.5 degrees C caused an increase of the volatile fatty acid to alkalinity ratio, a decline in digester performance, and an elevated production of methyl mercaptan and hydrogen sulfide. A rapid increase of the digester temperature at HTP from 54 to 58 degrees C caused an elevated production of methyl mercaptan, but the effect on the volatile fatty acid to alkalinity ratio and digester performance was insignificant. It is likely that these effects observed at TITP and HTP were transient responses to rapid changes in temperature.  相似文献   

7.
Simulation studies for a full-scale anaerobic unit of a wastewater treatment plant (WWTP) were performed using the anaerobic digestion model no. 1 (ADM1). The anaerobic full-scale plant consists of one mesophilic and one thermophilic digester, operated in an anaerobic sequential batch reactor (ASBR) mode, and sludge enrichment reactors (SER) for each digester. The digesters are fed with a mixture of vegetable waste and process wastewater from the food factory. Characteristics such as COD(total), N(total) and NH(4)-N concentrations in the influent and effluent of the digester and SERs were measured and used for input fractionation. Parameters such as level, pH, biogas amount and composition in the digester were measured online and used for calibration. For simulation studies, different temperatures and operation modes with varying chemical oxygen demand (COD) input loads corresponding to feedstocks such as fruits, vegetables and grain were analysed and compared. Higher gas production and digestion efficiency in the thermophilic reactor and in shorter cycles were found and confirmed at full scale. Serial operation mode increased the gas production, but pH inhibition occurred earlier. Feeding only biosolids into digester I and the effluent of digester I together with process water into digester II further improved gas production in serial operation mode.  相似文献   

8.
In general, mesophilic anaerobic digestion of sewage sludge is more widely used compared to thermophilic digestion, mainly because of the lower energy requirements and higher stability of the process. However, the thermophilic anaerobic digestion process is usually characterised by accelerated biochemical reactions and higher growth rate of microorganisms resulting in an increased methanogenic potential at lower hydraulic retention times. Furthermore, thermal pre-treatment is suitable for the improvement of stabilization and could be realized at relatively low cost especially at low temperatures. The present study investigates the effect of the pre-treatment at 70 degrees C on thermophilic (55 degrees C) anaerobic digestion of primary and secondary sludge in continuously operated digesters. Thermal pre-treatment of primary and secondary sludge at 70 degrees C enhanced the removal of organic matter and the methane production during the subsequent anaerobic digestion step at 55 degrees C. It also greatly contributed to the destruction of pathogens present in primary sludge. Finally it results in enhanced microbial activities of the subsequent anaerobic step suggesting that the same efficiencies in organic matter removal and methane recovery could be obtained at lower HRTs.  相似文献   

9.
The objective of the present work was to evaluate the effect of hydraulic retention time (HRT) on hydrolysis and acidogenesis for the pretreatment processes: acid phase digestion (APD) and autothermal thermophilic aerobic digestion (ATAD) using blended municipal sludge. The effect of the different pretreatment steps on mesophilic anaerobic digestion (MAD) was evaluated in terms of methane yield, keeping the operating conditions of the MAD the same for all systems. Best operating conditions for both APD and ATAD were observed for 2.5 d HRT with high total volatile fatty acids (tVFA), and the highest methane yield observed for MAD. No significant difference was observed between the two processes in terms of overall volatile solids (VS) reduction with same total HRT. The autothermal process produced heat of 14,300 J/g VS removed from hydrolytic and acetogenic reactions without compromising overall methane yields when the HRT was 2.5 d or lower and the total O2 used was 0.10 m3 O2/g VS added or lower. However, the process needs the input of oxygen and engineering analysis should balance these differences when considering the relative merits of the two pretreatment processes. This is the first study of its kind directly comparing these two viable pretreatment processes with the same sludge.  相似文献   

10.
Anaerobic digestion can adapt to free ammonia to a certain extent. During the anaerobic digestion of slaughterhouse waste, however, an ammonia concentration of up to 15 g Nl(-1) can be reached in the sludge liquid and this will even inhibit adapted sludge. To lower this concentration, a fraction of the digester liquid must therefore be continuously separated from the digested sludge and the free ammonia stripped before the liquid is recycled to the digester. A mesophilic laboratory digester was successfully operated with an ammonium concentration of 4-5g l(-1) and a pH of 8.0-8.4. After free ammonia stripping, the excess liquid was treated in a laboratory SBR for nitrogen and phosphorus removal before being added to the receiving water. The effluent had no toxic effect on daphnia and algae.  相似文献   

11.
To maintain a stable thermophilic (55 degrees C) anaerobic digestion treating toilet paper-containing garbage, it is necessary to operate the digester at long hydraulic retention time (HRT) and low organic loading rate (OLR). Critical conditions of the digestion were investigated by operating the digester at HRT 23 days and OLR 3.4 gCOD(Cr)/L/d (R1) or HRT 14 days and OLR 5.6 gCOD/Cr)/L/d (R2) separately. Characteristics of methanogenesis of the two digesters were examined by measuring gas generation volume and volatile fatty acids (VFA) concentration, and the populations of four anaerobic acidogens and three methanogens were analyzed using quantitative PCR method. In digester R1, methanogenic activity was unstable but it could be recovered by stopping feeding as though VFA accumulation occurred. The population of acidogens and two methanogens were maintained at 10(11) - 10(13) copies/L, however, the population of Methanoculleus could not be recovered after methanogenesis recovering. In digester R2, the period of methanogenesis was significantly shorter than that in digester R1. Both the acidogens and the methanogens could not be maintained at a stable concentration. It is suggested that the critical HRT to sustain the population of acidogens in this process should be longer than 14 days and for all kinds of methanogens, HRT should be longer than 23 days.  相似文献   

12.
High rate anaerobic technologies offer cost-effective solutions for "sewage" treatment in the temperate climate of Palestine and Jordan. However, local sewage characteristics demand amendments to the conventional UASB reactor design. A solution is found in a parallel operating digester unit that stabilises incoming solids and enriches the UASB sludge bed with methanogenic activity. The digester operational conditions were assessed by operating eight CSTRs fed with primary sludge. The results showed a high degree of sludge stabilization in the parallel digesters at SRTs>or=10 and 15 days at process temperatures of 35 and 25 degrees C, respectively. The technical feasibility of the UASB-digester combination was demonstrated by continuous flow pilot-scale experiments. A pilot UASB reactor was operated for 81 days at 6 hours HRT and 15 degrees C and was fed with raw domestic sewage. This period was subsequently followed by an 83 day operation period incorporating a parallel digester unit, which was operated at 35 degrees C. The UASB-digester combination achieved removal efficiencies of total, suspended, colloidal and dissolved CODs of respectively 66, 87, 44 and 30%. Preliminary model calculations indicated that a total reactor volume of the UASB-digester system corresponding to 8.6 hours HRT might suffice for sewage treatment in Palestine.  相似文献   

13.
The potential of a mesophilic-thermophilic-mesophilic anaerobic digestion system was investigated with respect to improvement of both digestion and sanitation efficiencies during treatment of liquid cattle manure. The pilot plant produced a high methane yield from liquid dairy cattle manure of 0.24 m3 (kg VSfed)(-1) Considering the low system loading rate of 1.4-1.5 kg VS (m3 d)(-1), digestion efficiency compared to conventional processes did not appear improved. The minimum guaranteed retention time in the tubular thermophilic reactor was increased compared to a continuously stirred tank reactor. Levels of intestinal enterococci in raw liquid manure as determined with cultivation methods were reduced by 2.5 -3 log units to a level of around 10(2) cfu/mL. This sanitizing effect was achieved both during mesophilic-thermophilic-mesophilic and thermophilic-mesophilic treatment, provided the thermophilic digester was operated at 53-55 degrees C. A change in feeding interval from 1 h to 4 h did not significantly alter methane yield and sanitation efficiency. It was proposed that a two-stage, thermophilic-mesophilic anaerobic digestion system would be able to achieve the same sanitizing effect and equal or better digestion efficiency at lower costs.  相似文献   

14.
This work elucidates the effects of pretreatment of secondary sludge by microwave irradiation on anaerobic digestion. The soluble chemical oxygen demand (COD) concentration increased up to 22% as microwave irradiation time increased, which indicated the sludge particles disintegrated. Three identical automated bioreactors with working volume of 5 l were used as anaerobic digesters at mesophilic temperature (35 degrees C). The reactors were separately fed with sludge with microwave pretreated- and control- sludge at different hydraulic retention times (HRT). The volatile solid (VS) reduction in the control operation was approximately 23.2 +/- 1.3%, while it was 25.7 +/- 0.8% for the reactors with the pretreated sludge. The average biogas production rate with the pretreated sludge at 8, 10, 12, and 15 days HRTs was 240 +/- 11, 183 +/- 9, 147 +/- 8, and 117 +/- 7 ml/l/d respectively, while those with the control sludge were 134 +/- 12 and 94 +/- 7 ml/l/d at 10 and 15 days HRTs. Maximum rates of COD removal and methane production with the pretreated sludge were 64% and 79% higher than those of the control system, respectively.  相似文献   

15.
The performance of a novel high-rate anaerobic process, the anaerobic digestion elutriated phased treatment (ADEPT) process, for treating a slurry-type piggery waste (55 g COD/L and 37 g TS/L) was investigated. The ADEPT process consists of an acid elutriation slurry reactor for hydrolysis and acidification, followed by an upflow anaerobic sludge bed reactor for methanification. This process provides stable and high system performance with short HRT (7.4 d) and better effluent quality (2 g SCOD/L and 0.68 g VSS/L) due to the alkaline pH condition for hydrolysis/acidification phase, high refractory solids removal and ammonia toxicity reduction. The optimum pH and HRT for hydrolysis/acidogenesis of the piggery waste were 9 and 5 days at both 35 degrees C and 55 degrees C conditions. The hydrolysis and acidification rate in the mesophilic reactor were 0.05 d(-1) and 0.11 d(-1), meaning that hydrolysis was a limiting step. SCOD production by the hydrolysis was about 0.26 g SCOD/g VS(fed) (3.6 g SCOD/g VS reduction). Methane production and content in the system were 0.3 L CH4/g VS(fed) (0.67 L CH4/g VS destroyed) and 80%, respectively, corresponding to 0.23 L CH4/g COD removal (@STP).  相似文献   

16.
Previously, we found that the newly isolated Clostridium sp. strain JC3 became the dominant cellulose-degrading bacterium in thermophilic methanogenic sludge. In the present study, the behavior of strain JC3 in the thermophilic anaerobic digestion process was investigated quantitatively by molecular biological techniques. A cellulose-degrading experiment was conducted at 55 degrees C with a 9.5 L of anaerobic baffled reactor having three compartments (Nos. 1, 2, 3). Over 80% of the COD input was converted into methane when 2.5 kgCOD m(-3) d(-1) was loaded for an HRT of 27 days. A FISH probe specific for strain JC3 was applied to sludge samples harvested from the baffled reactor. Consequently, the ratio of JC3 cells to DAPI-stained cells increased from below 0.5% (undetectable) to 9.4% (compartment 1), 13.1% (compartment 2) and 21.6% (compartment 3) at day 84 (2.5 kgCOD m(-3)d(-1)). The strain JC3 cell numbers determined by FISH correlated closely with the cellulose-degrading methanogenic activities of retained sludge. A specific primer set targeting the cellulase gene (cellobiohydrolaseA: cbhA) of strain JC3 was designed and applied to digested sludge for treating solid waste such as coffee grounds, wastepaper, garbage, cellulose and so on. The strain JC3 cell numbers determined by quantitative PCR correlated closely with the cellulose-sludge loading of the thermophilic digester. Strain JC3 is thus important in the anaerobic hydrolysis of cellulose in thermophilic anaerobic digestion processes.  相似文献   

17.
The process of anaerobic thermophilic digestion of municipal wastewater sludge with a recycled part of thickened digested sludge, was studied in semi-continuous laboratory digesters. This modified recycling process resulted in increased solids retention time (SRT) with the same hydraulic retention time (HRT) as compared with traditional digestion without recycling. Increased SRT without increasing of HRT resulted in the enhancement of volatile substance reduction by up to 68% in the reactor with the recycling process compared with 34% in a control conventional reactor. Biogas production was intensified from 0.3 L/g of influent volatile solids (VS) in the control reactor up to 0.35 L/g VS. In addition, the recycling process improved the dewatering properties of digested sludge.  相似文献   

18.
Continuous Stirred Tank Reactors (CSTRs), operated in batch mode, were used to evaluate the feasibility of psychrophilic (low temperature) digestion of perennial rye grass in a long term experiment (150 days) for the first time. The reactors were operated in parallel at 3 different temperatures, 10, 15 and 37 degrees C. Hydrolysis, acidification and methanogenesis were assessed by VS degradation, by soluble chemical oxygen demand (SCOD) and volatile fatty acids (VFA) production, and by methane production, respectively. Hydrolysis was the rate-limiting step at all temperatures and the rates and extent of hydrolysis were considerably lower at 15 and 10 degrees C, than at 37 degrees C. The total VS degradation was 53%, 34% and 19% at 37, 15 and 10 degrees C, respectively. Acidification was not affected by temperature and VFA production and consumption was balanced in all cases, except at 10 degrees C. Methane yields were 0.215 m3 CH4 kg(-1) VS(-1) added, 0.160 m3 CH4 kg(-1) VS(-1) added and 0.125 m3 CH4 kg(-1) VS(-1) added at 37, 15 and 10 degrees C, respectively. Methanogenesis was not strongly affected at 15 C but it became rate-limiting at 10 degrees C. Overall, the solid degradation and methane production performance under psychrophilic conditions was encouraging and greater than previously reported. Considering the non-acclimated, mesophilic nature of the inoculum, there are grounds to believe that low-temperature anaerobic digestion of grass could be feasible if coupled to efficient hydrolysis of the biomass.  相似文献   

19.
Membrane-coupled anaerobic digestion utilizes a concept of simultaneous sludge digestion and thickening. Membranes may successfully be applied to eliminate the need for thickening polymers and avoid their likely inhibitory effect on anaerobic biomass. A 550 L completely mixed anaerobic digester was operated under mesophilic conditions (35 degrees C). Two ultrafiltration membrane systems were evaluated for their potential in membrane-coupled anaerobic digestion: vibrating and cross flow. A volatile solids reduction of 590% was achieved at an average mixed liquor suspended solids concentration of 1.8%. The substrate utilization rate was 1.3 d(-1). The vibrating membrane operated at a flux of 1.6-2.0 m3/m2-d and the tubular membrane fluxes in the range 3.4-3.6 m3/m2-d.  相似文献   

20.
Anaerobic digestion for the treatment of sludge in wastewater treatment plants has been reported to produce a low organic loaded effluent with an acceptable economic cost. But in the last years, new regulations and the increasing sludge production invite us to find an alternative and/or to improve the process efficiency. Moreover, the use of the effluent as fertilizer in agriculture imposes more restrictions on digestion process product and its micropollutant contents to protect the environment. In this study, a performance of the anaerobic digestion under mesophilic and thermophilic conditions at different hydraulic retention times (HRT) is assessed and the removal efficiencies of two important compounds or family compounds (Polycyclic Aromatic Hydrocarbons, PAH, and Di-2-(Ethyl-Hexyl)-Phthalate, DEHP) are evaluated. A positive effect of thermophilic temperature was observed on both micropollutants' biodegradation. However, HRT effect also had an important role for DEHP and low molecular weighted PAH removal.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号