相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
正交相位法是超声多普勒技术中提取双向性血流信息的一种重要方法。由于正交信号对之间通常存在幅度和相位的不平衡,从而导致了正、反血流信息的混淆,影响了平均频率,最大的估计和声谱图的正确显示,本文提出的补偿方法,让其中一个正交信号通过按一定要求设计的线性滤波器,从而得到幅度和相位基本平衡的正交信号对,提高了超声多普勒系统提取双向性血流的性能。  相似文献   

2.
Most of the important clinical indices of blood flow are estimated from the spectrograms of Doppler ultrasound (US) signals. Any noise may degrade the readability of the spectrogram and the precision of the clinical indiCes, so the spectral enhancement plays an important role in Doppler US signal processing. A new Doppler US spectral enhancement method is proposed in this paper and implemented in three main steps: the Gabor transform is used to compute the Gabor coefficients of a Doppler US signal, the spectral subtraction is performed on the magnitude of the Gabor coefficients, and the Gabor expansion with the spectral subtracted Gabor coefficients is used to reconstruct the denoised Doppler US signal. The different analysis and synthesis windows are examined in the Gabor transform and expansion. The signal-to-noise ratio (SNR) improvement together with the overall enhancement of spectrograms are examined on the simulated Doppler US signals from a femoral artery. The results show the denoising method based on the orthogonal-like Gabor expansion achieves the best denoising performance. The experiments on some clinical Doppler US signals from umbilical arteries confirm the superior denoising performance of the new method.  相似文献   

3.
Doppler ultrasound signal denoising based on wavelet frames   总被引:6,自引:0,他引:6  
A novel approach was proposed to denoise the Doppler ultrasound signal. Using this method, wavelet coefficients of the Doppler signal at multiple scales were first obtained using the discrete wavelet frame analysis. Then, a soft thresholding-based denoising algorithm was employed to deal with these coefficients to get the denoised signal. In the simulation experiments, the SNR improvements and the maximum frequency estimation precision were studied for the denoised signal. From the simulation and clinical studies, it was concluded that the performance of this discrete wavelet frame (DWF) approach is higher than that of the standard (critically sampled) wavelet transform (DWT) for the Doppler ultrasound signal denoising  相似文献   

4.
A complete 3-D ultrasonic pulsed Doppler system has been developed to measure quantitatively the velocity vector field of a fluid flow independently of the probe position. The probe consists of four 2.5 MHz piezocomposite ultrasonic transducers (one central transmitter and three receivers separated by 120°) to measure the velocity projections along three different directions. The Doppler shift of the three channels is calculated by analog phase and quadrature demodulation, then digitally processed to extract the mean velocity from the complex spectrum. The accuracy of the 3-D Doppler technique has been tested on a moving string phantom providing an error of about 4% for both amplitude and direction with an acquisition window of 100 ms  相似文献   

5.
吴昊  柴俊  安帅  夏澍 《发电技术》2020,41(2):186
针对采集变压器运行声信号时会混入噪声的情况,提出了基于稀疏分量分析-变分模态分解(sparse component analysis-variational modal decomposition,SCA-VMD)分离变压器运行声信号并降噪的方法。基于稀疏特性的欠定盲源分离能够在观测信号数目小于未知源信号数目的情况下实现源信号的有效分离,变分模态分解(VMD)能将一个多分量信号一次性分解为多个单分量信号。以两路观测信号作为输入,利用稀疏分量分析法(SCA)分离得到变压器运行声信号,再利用VMD将分离信号分解为4层本征模态函数(intrinsic mode function,IMF)分量,通过阈值滤波的方法对高频分量和低频分量进行去噪处理,利用新的IMF分量重构得到去噪信号。仿真试验和实际试验结果表明,该方法能实现对变压器运行声信号的有效分离和去噪处理。  相似文献   

6.
A number of arrangements are possible for deriving signals in phase quadrature from interferometers, so that bi-directional counting of the interference fringe movements can be carried out. Arrangements which avoid splitting the image field are preferred for laser light sources, and can give a better signal-to-noise ratio. In environments where the interferometer is subjected to vibration, the fringe counting system may be required to handle rapid reversals in the direction of movement. In these circumstances the rate of production of rapid counting signals of alternate direction may be considerably reduced by using an appropriate logic system between the interferometer and the counter.  相似文献   

7.
Linear equations for modeling echo signals from shift-variant systems forming ultrasonic B-mode, Doppler, and strain images are analyzed and extended. The approach is based on a solution to the homogeneous wave equation for random inhomogeneous media. When the system is shift-variant, the spatial sensitivity function-defined as a spatial weighting function that determines the scattering volume for a fixed point of time-has advantages over the point-spread function traditionally used to analyze ultrasound systems. Spatial sensitivity functions are necessary for determining statistical moments in the context of rigorous image quality assessment, and they are time-reversed copies of point-spread functions for shift variant systems. A criterion is proposed to assess the validity of a local shift-invariance assumption. The analysis reveals realistic situations in which in-phase signals are correlated to the corresponding quadrature signals, which has strong implications for assessing lesion detectability. Also revealed is an opportunity to enhance near- and far-field spatial resolution by matched filtering unfocused beams. The analysis connects several well-known approaches to modeling ultrasonic echo signals.  相似文献   

8.
Autoregressive (AR) techniques are investigated by developing mean and maximum frequency estimators suitable for use in Doppler color flow mapping systems, where they are most needed. The estimators are based on low-order (for computational efficiency) AR models applied to complex signals whose real and imaginary parts are the in-phase and quadrature components of the analytical Doppler signal, respectively. A large number of simulated data sequences generated by a sinusoidal computer model and having different number of samples, spectral shapes, bandwidths, and signal-to-noise ratios are used to examine the performance (bias and variance) of the estimators in a systematic manner. Comparisons are made with the established autocorrelation technique, whose output is shown to be identical to one of the AR mean frequency estimators described.  相似文献   

9.
Blood flow measurement using Doppler ultrasound has become a useful tool for diagnosing cardiovascular diseases and as a physiological monitor. Recently, pocket-sized ultrasound scanners have been introduced for portable diagnosis. The present paper reports the implementation of a portable ultrasound pulsed-wave (PW) Doppler flowmeter using a smartphone. A 10-MHz ultrasonic surface transducer was designed for the dynamic monitoring of blood flow velocity. The directional baseband Doppler shift signals were obtained using a portable analog circuit system. After hardware processing, the Doppler signals were fed directly to a smartphone for Doppler spectrogram analysis and display in real time. To the best of our knowledge, this is the first report of the use of this system for medical ultrasound Doppler signal processing. A Couette flow phantom, consisting of two parallel disks with a 2-mm gap, was used to evaluate and calibrate the device. Doppler spectrograms of porcine blood flow were measured using this stand-alone portable device under the pulsatile condition. Subsequently, in vivo portable system verification was performed by measuring the arterial blood flow of a rat and comparing the results with the measurement from a commercial ultrasound duplex scanner. All of the results demonstrated the potential for using a smartphone as a novel embedded system for portable medical ultrasound applications.  相似文献   

10.
方昕  汪源源  王威琪 《声学技术》2006,25(4):304-308
超声多普勒技术作为一种无损检测手段被广泛应用于血管狭窄的检测。以往的血管狭窄仿真信号的研究仅限于双边狭窄的对称情况,文章提出了一种单边狭窄血管中超声多普勒信号的仿真方法。首先用有限元分析方法(FEM)计算出狭窄血管中血流流速场分布情况,然后用总体分布非参数估计法计算出超声多普勒信号的功率谱密度(PSD),再用余弦叠加法获取仿真的超声多普勒时域信号。用快速傅里叶变换(FFT)计算仿真超声多普勒信号的频谱,从中计算最大频率、平均频率和频谱宽度等参数,分析它们在不同流速和狭窄程度下的特征,为血管疾病的诊断提供敏感的参数。  相似文献   

11.
多普勒血流信号最大频率曲线的特征分析及应用   总被引:2,自引:2,他引:0       下载免费PDF全文
文章主要研究从超声多普勒血流信号的最大频率曲线中提取特征值,并用于临床血管疾病诊断的方法。先利用短时傅里叶变换分析采样所得的音频多普勒血流信号,接着用百分比法得到信号的最大频率曲线,然后提取最大频率曲线频谱各峰值的比作为特征值,并将它们用于血管疾病的诊断。通过对颈动脉多普勒血流信号的临床分析表明:此方法比传统的声谱参数法有更高的诊断准确性。  相似文献   

12.
张羽  汪源源  王威琪  刘斌 《声学技术》2000,19(4):197-200
本提出了利用离散小波框架结合软阈值的方法对超声多普勒信号进行降噪。通过对模拟多普勒信号和临床信号的降噪实验,发现利用小波框架的降噪方法可以获得比标准正交小波变换的降噪方法更好的降噪效果。  相似文献   

13.
针对试飞中发动机转静子碰摩故障信号,首先应用小波阈值方法对原始信号进行降噪处理,由此滤除高频噪声干扰,同时可保留含有重要故障特征的突变信息;对降噪后信号进行连续小波变换,时频分析结果具有很好的实时跟踪转速频率能力,且频带清晰,故障特征明显,为今后真实飞行载荷下的实时故障监测提供一种有效途径。  相似文献   

14.
A class of adapted mean frequency estimators is proposed for color flow mapping. These estimators can be fitted to the specific characteristics of a given Doppler signal to optimize the compromise between the range of analysable frequencies and the variance of mean frequency estimation. A sub-optimal estimator is derived for real-time applications, and an adaptive criterion based on the Doppler signal variance is developed for color flow mapping applications. Its performance is compared to that of the usual correlation phase estimator on simulated Doppler signals and on synthetic Doppler images. An improvement in image quality is achieved, mainly for low signal-to-noise ratio Doppler signals.  相似文献   

15.
赵奎  杨道学  曾鹏  王晓军  钟文  龚囱  闫雷 《振动与冲击》2021,(5):179-185,210
针对岩石声发射(AE)信号的低信噪比、随机性强、非平稳性等特点,提出了一种基于总体经验模态(EEMD)及单通道盲源分离(SCBSS)的AE信号滤波方法。将含有背景噪声的AE信号进行EEMD分解,得到一系列按频率从高到低排列的本征模函数(IMF);提取高频背景噪声信号与观测信号构建虚拟多通道观测信号;利用快速不动点优化算法(FastICA)对构建的虚拟多通道观测信号进行盲源分离(BSS),进而得到滤波后的AE信号。通过构造含噪声AE信号进行数值仿真实验及实测数据分析,将基于EEMD及SCBSS滤波方法与小波阈值滤波方法进行比较。实验结果表明:小波阈值滤波方法会导致滤波后的AE信号频域信息失真,影响滤波后的AE信号上升时间,能量等参数识别;该方法可以对含噪声AE信号进行有效地滤波处理,能够较好地滤除AE信号中的非平稳随机噪声,并且能够保护滤波后的AE信号频域信息。  相似文献   

16.
冠脉内超声多普勒血流信号的极点特征   总被引:1,自引:0,他引:1       下载免费PDF全文
研究冠脉内超卢多普勒血流信号的极点特征,期望为微循环障碍等缺血性心脏病的诊断提供客观指标。先对冠脉内超声多普勒血流信号分段建立自回归滑动平均(Auto-regressive&moving-average,即ARMA)模型,获取一个心动用期信号的极点分布,计算极点分布的特征参数。通过分析18例冠脉内超声多普勒血流信号,得出若干个对冠脉微循环障碍敏感的特征参数。结果表明:冠脉内超声多普勒血流信号的极点特征参数,可以一定程度反映冠脉循环的状况。  相似文献   

17.
For pt.I see ibid., vol.50, no.3, p.267-78 (2003). This paper presents an application of continuous wave ultrasound Doppler velocity measurements to two-phase flow in pipes. In many petroleum wells, the multiphase flow is separated into two phases: the first is a liquid phase and the second is a gas phase with small scatterers. The problem of multiphase velocity profile measurements has not been satisfactorily solved by classical approaches due to the multiphase nature of the fluid and the presence of colored noise, which introduces a significant bias in classical frequency estimators. We propose the use of resolution frequency techniques to overcome the classical limitations. Direct estimation of Doppler frequency then obtained using either time frequency maximum frequency or arguments of poles of the parametric model that identifies the Doppler part of the signal is discussed. The tests made with synthetic Doppler signals and two-phase flow have demonstrated the excellent performance of the high resolution techniques based on reassignment and parametric techniques.  相似文献   

18.
Linear equations derived from the scattering matrix approach to the two-port resonator were solved, and analytical expressions for the normalized SAW amplitudes were obtained. Asynchronous and synchronous resonators were analyzed numerically. It was shown that the output of the two-port resonator is a sum of two signals. In the case of the asynchronous resonator, these signals are in phase at a resonance frequency; for the synchronous resonator, they are in phase quadrature, which causes the higher insertion loss of the synchronous resonator  相似文献   

19.
Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 MHz high-frequency array ultrasound imaging system. Phantom studies show that the Doppler flow mode of the dual mode is capable of measuring the flow velocity from 0.1 to 15 cm s−1 with high accuracy (p-value = 0.974 > 0.05). In the in vivo study of zebrafish, both TD and Doppler flow signals were simultaneously obtained from the zebrafish heart for the first time, and the synchronized valve motions with the blood flow signals were identified. In the longitudinal study on the zebrafish heart regeneration, the parameters for diagnosing the diastolic dysfunction, for example, E/Em < 10, E/A < 0.14 for wild-type zebrafish, were measured, and the type of diastolic dysfunction caused by the amputation was found to be similar to the restrictive filling. The diastolic function was fully recovered within four weeks post-amputation.  相似文献   

20.
小波信号消噪及阈值函数的一种改进方法   总被引:4,自引:0,他引:4  
对于非平稳信号,小波多尺度分解是一种有效的信号去噪方法。介绍了阈值计算的Stein的无偏风险估计子(SURE)阈值、多分辨率SURE阈值和平移不变阈值,以及硬取阈值、软取阈值估计子,同时提出了一种新的小波消噪阈值选取方法,提出了相关参数的确定原则;并与硬取阈值、软取阈值进行比较,仿真结果表明,消噪效果有明显的改观。  相似文献   