首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
OBJECTIVES: To compare cardiac output and stroke volume measured by multiplane transesophageal Doppler echocardiography with that measured by the thermodilution technique. DESIGN: Prospective direct comparison of paired measurements by both techniques in each patient. SETTING: Cardiac surgery and myocardial infarction intensive care units. PATIENTS: Twenty-nine patients, mean age (+/- SD) 67 +/- 8 years. Nineteen had undergone open heart surgery and 10 had suffered acute myocardial infarction. METHODS: Cardiac output and stroke volume were measured simultaneously by the thermodilution technique and multiplane transesophageal Doppler echocardiography via the transgastric view (119 +/- 8 degrees) with the sample volume positioned at the level of the left ventricular outflow tract. RESULTS: Stroke volume and cardiac output measurements were obtained in 29 of 33 patients (88%). Mean values were 50 +/- 13 mL and 4.8 +/- 1.3 L/min by Doppler and 51 +/- 14 mL and 4.9 +/- 1.4 L/min by thermodilution (r = 0.90, r = 0.91, p < 0.001). The mean differences in values obtained with the two techniques were 1 +/- 6 mL (2 +/- 12%) and 0.1 +/- 0.7 L/min (2 +/- 12%). CONCLUSIONS: Multiplane transesophageal echocardiography enhances the ability to estimate accurately cardiac output and stroke volume by providing new access to left ventricular outflow tract in critically ill patients.  相似文献   

2.
PURPOSE: To investigate whether there is a difference in the expression of adenovirus transgenes in human retinal pigment epithelial cells when the vector was exposed to the apical or basal surface, the effect of transgene expression on rod outer segment (ROS) phagocytosis and finally, the role of phagocytosis in gene transfer to RPE cells, using the Royal College of Surgeons (RCS) rat. METHODS: Monolayers of human retinal pigment epithelium (HRPE) or an RPE cell line (A407) had the apical or basal surfaces exposed to 10(7) pfu/ml of replication deficient adenovirus (Ad.RSV.betagal) carrying the beta-galactosidase marker gene, and the numbers of expressing cells were compared. Parallel cultures were infected and challenged with fluorescein-labelled bovine rod outer segments (FBROS). The fluorescence of infected versus uninfected cells was recorded for both challenged and unchallenged states, using fluorophotometric flow cytometry. Primary cultures of RCS rat RPE were established and the transgene uptake dynamics compared to control Long Evans rat RPE cells. RESULTS: The expression of transgene in HRPE and A407 cell cultures was an order of magnitude greater when the vector was exposed apically (analysis of variance p < 0.05). There was no difference in the phagocytic capacity of Ad.RSV.betagal-infected and -noninfected cells when challenged with FBROS. There was also no difference in the number of cells expressing transgene, when compared to the RCS or Long Evans control rat RPE. CONCLUSIONS: The surface of exposure in polarized retinal pigment epithelial cells affects the rate of uptake and expression of adenovirus. The defective ROS phagocytosis in RCS rat RPE cells did not lead to a decrease in transgene expression relative to the Long Evans control cells. Finally we have found that phagocytosis is not significantly altered with adenoviral transgene expression in this in vitro model.  相似文献   

3.
The penetration of four radioiodinated materials-Tyr-MIF-1, DAMGO, tyrosine, and albumin-into the periventricular tissue after ICV injection was studied in rats by film autoradiography. Rates of disappearance from the CNS for the injected compounds were also determined by computer-assisted image analysis of the autoradiographic images. The four materials showed distinct patterns of dispersion from the ventricular system, with Tyr-MIF-1 moving farthest into the parenchyma of the brain and albumin primarily restricted to the ventricular space. The other two compounds, tyrosine and DAMGO, had intermediate values. Tyr-MIF-1 also displayed the fastest rate of removal from the brain, which may represent the ability of the peptide to gain access to sites of saturable transport. By contrast, the exit from the brain of DAMGO was minimal, whereas the efflux of albumin and tyrosine was intermediate. These results show the utility of these methods in the simultaneous measurement of both the patterns of distribution within the CNS and the rates of removal from the CNS of compounds injected into the brain.  相似文献   

4.
In the present study, experimental exposures to hyperbaric oxygen (HBO2) were performed (30-min exposure to 2.8 bar (280 kPa) pure oxygen). During all phases of the experiment, blood flow velocity in the right middle cerebral artery was monitored with transcranial Doppler (TCD) sonography. Time courses of heart rate, blood pressure, respiratory rate, end-tidal CO2, and TCD mean velocity (Vmean) are described for a group of 23 subjects during uncomplicated exposure to HBO2 and for three subjects who showed signs of central nervous system (CNS) O2 toxicity, including one subject with a HBO2-induced generalized tonic-clonic seizure. Hyperbaric oxygen decreased Vmean an effect that could not completely be explained by changes in end-tidal CO2. The findings of the present study are in agreement with the concept that an increase in partial oxygen pressure is the primary factor underlying CNS O2 toxicity. Of the variables analyzed, the TCD Vmean is the most valuable variable for monitoring a HBO2 exposure. The Vmean showed the most pronounced change during HBO2 application, and in one subject a sudden increase in Vmean during HBO2 exposure heralded toxicity before clinical signs. It should be realized, however, that the small series of subjects with toxicity in this study does not allow us to draw definite conclusions.  相似文献   

5.
6.
We investigated whether multiplane transesophageal Doppler echocardiography using transgastral views allows determination of pressure gadients and valve areas in patients with aortic stenosis. This technique was feasible in 35 of 39 patients (90%), with highly significant correlations with results obtained from transthoracic Doppler echocardiography and cardiac catheterization, thus offering an alternative approach for quantification of aortic stenosis.  相似文献   

7.
We report an unusual finding of ostial stenosis of an anomalous left main coronary artery originating from the pulmonary artery in a symptom-free adolescent girl. Transesophageal echocardiography with Doppler color imaging correctly identified all of the salient features of this anomaly including proximal stenoses of the right and left coronary arteries. These findings were subsequently confirmed at cardiac catheterization.  相似文献   

8.
BACKGROUND: Coronary blood reserve is the capacity of coronary vessels to vasodilate and thereby to increase the blood flow, when the heart needs more energy. However, when a coronary stenosis occurs, the capacity to vasodilate is reduced or completely diminished. It is then necessary to use all the tools useful in evaluating the functional conditions of the coronary vessels. Above all, the intracoronary Doppler technique is used to measure the velocity of blood flow. Our purpose was to evaluate a non-invasive tool "Multiplane Transesophageal Echocardiography" in the study of velocity of the anterior descendent artery before and after adenosine infusion. METHODS: At first, we studied 28 patients (pts), which we divided in two groups: Group A, 18 pts 59.38 +/- 8.23 mean age, 15 M. and 3 F., with anterior descending disease; Group B 10 pts, 59.20 +/- 8.48 mean age, 7 M. and 3 F, without significant stenosis (> 75%). Echocardiography examinations were performed with a 5 MHz multiplane probe, connected to a 1000 Hewlett Parkard echocardiography. Before the test, Diazepam 1 mg i.v. and Lidocaine spray were administered to the patients. We introduced the transesophageal probe and after choosing the best position of the aortic short axis view, we studied the anterior descending artery and measured the maximum and mean diastolic and sistolic velocities (V.MAX D., V.MN.D., V.MAX S., V.MN.S.). RESULTS: Transesophageal echocardiography allowed us to study the anterior descending artery in 95% of pts. There were no side effects, except for one pt affected by severe bradicardia. In Group B there was an increase of the diastolic and sistolic velocity after adenosine infusion, resulting twice greater they the rest values. The adenosine/rest velocities ratios were statistically significant (V.MAX D. p < 0.02) (V.MN.D. p < 0.03). CONCLUSION: Our results demonstrated an higher capacity of the Multiplane Transesophageal Echocardiography in studiing coronary blood reserve. We used adenosine, as a vasodilator drug, because of its short half-life and because it can be replatedly infused. The flow velocity values increased up to more than twice the rest values only in normal subjects.  相似文献   

9.
OBJECTIVE: Transesophageal echocardiographic analysis of color Doppler characteristics of mitral valvular regurgitation jets. DESIGN: Transesophageal echocardiographic prospective study. SETTING: Ambulatory patients referred to Echocardiographic Laboratory of Gregorio Mara?on General Hospital, Madrid, Spain. MATERIAL AND METHODS: We studied a group of 100 consecutive patients with mitral regurgitation diagnosis. In each patient we calculated the degree of severity, percentage of wall intersection, maximal traced area, axis direction, atrial depth, maximal transversal diameter, perimeter and angle of the mitral regurgitation jet. We divided the entire population in three different groups according to the jet direction in central (CJ), eccentric (EJ) and wall jets (WJ). MAIN RESULTS: The direction of the mitral regurgitation jet was central in 49%, eccentric in 33% and impinging the left atrial wall in 18%. The mitral regurgitation jet angle was in the CJ 80 +/- 11 degrees, EJ 33 +/- 10 degrees and WJ 6 +/- 7 degrees. Maximal mitral regurgitant traced area in CJ was 732 +/- 104 mm2, EJ was 593 +/- 110 mm2 and WJ was 267 +/- 80 mm2. Maximal regurgitant jet depth in CJ was 36 +/- 17 mm, EJ 30 +/- 15 mm and WJ 49 +/- 14 mm. The perimeter of the mitral regurgitation jet in the CJ was 87 +/- 22 mm, EJ was 68 +/- 22 mm and WJ was 92 +/- 30 mm. CONCLUSIONS: Color Doppler quantification criteria are not useful in all patients with mitral regurgitation jets. The presence of atrial walls close to the mitral regurgitation jet area is an important factor in the mitral regurgitation color Doppler evaluation.  相似文献   

10.
OBJECTIVE: To give a detailed evaluation on main pulmonary artery blood velocity patterns, in patients with ischemic heart disease and to provide recommendations for pulsed Doppler sample volume placement, in order to optimize cardiac output estimation. METHODS: Using magnetic resonance phase and esophageal color Doppler velocity mapping in 12 patients with ischemic heart disease and undergoing coronary artery by-pass grafting, very similar data on pulmonary artery blood velocity patterns were provided for comparison with each other. RESULTS: Peak blood velocities were located in the inferior half of the main pulmonary artery cross-sectional area. Early after peak systole the highest velocities shifted towards the superior/left (major curvature) with a simultaneous decrease in velocities inferiorly. The velocity decrease further evolved into retrograde flow to the inferior/right (minor curvature). This feature was significantly enhanced compared to earlier findings in healthy volunteers. The mean temporal blood velocity profiles were asymmetrically skewed, thereby giving unreliable cardiac output estimates based on single point Doppler blood velocity recordings. The error incurred may amount to more than 100% in extreme cases. According to our data, optimal assessment of cardiac output should be based on multiple sample volumes placed along the inferior/right to superior/left diameter. CONCLUSIONS: MR-phase velocity mapping and multiplane transesophageal color Doppler recordings provided similar blood velocity patterns in patients with ischemic heart disease. The skewness of the mean temporal blood velocity profile is enhanced compared with healthy subjects, resulting in error in the assessment of CO by means of pulsed Doppler echocardiography. By using multiple Doppler sample volumes, the error can be minimized.  相似文献   

11.
Genetic variation in correlations among size-related traits of head, thorax, and wings was examined in Drosophila buzzatii, by comparing the pattern of the Phenotypic Correlation Matrix (Rp) between inversion karyotypes of the second chromosome. No similarity in Rp was observed between some karyotypes in a natural population. The pattern of Rp in wild-reared heterokaryotypes, but not in homokaryotypes, was similar to the whole population represented by laboratory-reared flies. While phenotypic correlations in wild-reared flies were found to be larger than in laboratory-reared flies, similarity in the pattern of Rp was very high for one homokaryotype reared in both environments: the relatively homogeneous lab environment and the more variable field environment. While no such a similarity across environments was detected between different karyotypes, the pattern of Rp was similar for a same homokaryotype in different populations. Thus, the lack of karyotypic similarity in Rp is, at least partially, genetic. These results indicate that chromosomal inversions are factors affecting genetic correlations among traits known to be phenotypically correlated with adult fitness components in this species.  相似文献   

12.
J Vargas-Barrón 《Canadian Metallurgical Quarterly》1995,131(2):133-8; discussion 138-40
Eleven patients who underwent pulmonary valve autograft to aortic position with placement of bovine pericardial prosthesis in pulmonary position were studied with echocardiography. Transthoracic echocardiography, was performed on all patients before surgery. Transesophageal echocardiograms were practiced during the surgical procedure. The latter technique aided in immediate postoperative evaluation. Transthoracic and transesophageal echocardiography provide a practical and valuable means of investigating the pre, trans and postoperative conditions of patients undergoing Ross surgery.  相似文献   

13.
The aim of this study was to determine the role of Doppler echocardiography in establishing the prognosis of Stages to 4 cardiac failure. The echocardiographic indices of left ventricular filling were correlated with catheter data and the 2 year out come of patients. The study population included 54 patients examined prospectively in the context of an evaluation of their cardiac failure. Two years after the initial examination, 19 patients were dead or transplanted. Of the remaining 35 patients, 18 were reevaluated at 6 months. Of the echocardiographic parameters, "hyper normal" mitral flow with a high E/A ration indicated poor prognosis; when E/A > 2, the one year survival was 50% and the 2 year survival 42%. There was overlap between the groups of dead or transplanted and surviving patients only when the E/A ratio was between 2 and 3. The patients with E/A < 2 were all alive without any major events at 2 years. All patients with E/A > 3 had a poor prognosis. The E/A ratio was closely correlated with pulmonary capillary pressure levels (p < 0.001, r = 0.55) and lees closely with cardiac index (p < 0.05, r = 0.4) and radionuclide ejection fraction (p < 0.05, r = 0.28). After 6 months' vasodilator treatment with an angiotensin converting enzyme inhibitor (captopril) the E/A ratio decreased significantly from 1.85 +/- 0.78 to 1.0 0.55 (p < 0.02). A "hyper-normal" mitral flow is related to many factors, including high left ventricular filling pressures, mitral regurgitation and reduced left ventricular compliance. This appearance of mitral flow is a poor prognosis factor in severe cardiac failure.  相似文献   

14.
Blood flow velocity waveforms were recorded by color Doppler ultrasound from intraplacental villous and umbilical arteries in 20 normal and 23 severe preeclamptic pregnancies. The results of the resistance index measurements in intraplacental villous arteries were 0.51 +/- 0.037 and 0.55 +/- 0.052 in healthy controls and preeclamptics respectively, which was not significantly different. Resistance indices showed a decrease through the umbilical cord from fetus to placenta in both groups. We also noted that Doppler examination of the umbilical cord might be an early indicator of fetal compromise. Detectable intraplacental villous flows were in normal limits even in patients with abnormally high umbilical resistance indices and failure to detect villous artery color Doppler flow signals is probably associated with fetal compromise. We conclude that Doppler measurements from the intraplacental arteries cannot be used in clinical management of patients with severe preeclampsia.  相似文献   

15.
PURPOSE: The aim of the study was to establish the prognostic value and clinical implications of blood flow velocity measurements by Doppler guide wires during peripheral laser-assisted percutaneous transluminal angioplasty (PTLA). METHODS: 39 patients presenting with symptomatic peripheral arterial obstructive disease underwent angiography and blood flow velocity assessment by Doppler guide wire (0.018") prior to and following PTLA. Both quantitative angiography (QCA) for measurement of luminal diameters and Doppler assessment of maximum peak velocities (MPV) were performed 2 cm proximal, over and 2 cm distal to stenoses. The results were compared with the following clinical endpoints: 1. Short-term clinical improvement by AHA-criteria during first follow-up examination and 2. criteria for patency suggested by Rutherford [12] within 1 year (1-22 months). RESULTS: Angiography demonstrated initial success of PTLA in all patients. Relative diameter stenosis decreased from 70 +/- 0.04% to 17 +/- 0.05%. Mean clinically category improved from 2.7 +/- 0.1 to 1.2 +/- 0.1 following intervention. Mean grade of clinical improvement was 2.8 +/- 0.1. 22/39 patients demonstrated event-free follow-up examinations. Doppler measurements of MPV post PTLA in the proximal reference segment correlated with clinical outcome. MPV > or = 90 cm/s was associated with good primary success, unlimited walking capacity and event-free follow-up. MPV > or = 70 cm/s predicted an improvement of short-term clinical outcome by 2 grades (predictive value 80%). MPV < 70 cm/s was associated with both minor primary clinical improvement (+/- 0, +1) and increased incidence of restenosis during follow-up. CONCLUSION: Following PTLA, MPV adds information to angiographic success. MPV > or = 90 cm/s in a proximal reference segment following PTLA predicts good clinical outcome, whereas MPV < 70 cm/s is associated with minor primary clinical success and increased rates of restenosis.  相似文献   

16.
In preparation for a vasodilator study on chronic obstructive pulmonary disease (COPD), we investigated the reliability of recently described pulsed Doppler techniques for estimating pulmonary artery pressure (PAP) and cardiac output (CO). Our aims were to determine the following: (1) the imaging success rate for pulsed Doppler measurements; (2) the repeatability of the measurements, and interobserver and intraobserver variability; and (3) the accuracy of Doppler compared with catheter measurements. Doppler studies were attempted in 81 patients (cardiac disease [23], COPD [22], sleep apnea [32], and normal subjects [4]). Suitable images were obtained in 68 subjects (84 percent) and in 76 subjects (94 percent) for PAP and CO estimations, respectively. The lowest imaging success rates were in COPD patients (68 percent for PAP and 86 percent for CO estimation). Repeatability of the techniques was assessed in four cardiac patients and three healthy volunteers by performing four replicate studies in each subject over 1 h. Intrasubject coefficient of variation was < 10 percent for PAP and < 5 percent for CO. The intraobserver variability for Doppler estimation of systolic and mean PAP was 5.5 percent and 5.8 percent, respectively. The corresponding values for interobserver variability were 6.7 percent and 6.2 percent. Intraobserver and interobserver variability for "nongeometric" method of estimating CO was 5.1 percent and 5.9 percent, respectively. Agreement was good between catheter-measured and Doppler-estimated PAP in the 27 patients tested (cardiac [19] and COPD [8]) for both mean and systolic pressures (r = 0.96 and r = 0.97, respectively). The correlations between thermodilution and Doppler estimations of CO in eight COPD patients were 0.77 ("geometric" technique) and 0.97 ("nongeometric" technique). We conclude that pulsed Doppler techniques can be used to obtain accurate and reproducible quantitative information on pulmonary hemodynamics in a wide range of patients. Suitable Doppler images can be obtained in more than two thirds of COPD patients.  相似文献   

17.
The literature at this time does not give convincing evidence for use of pyridoxine as the sole treatment when confronted with a patient with idiopathic CTS. It may be of value as an adjunct in conservative therapy through altered perception of pain and increased pain threshold. For patients not responsive to conservative therapy, surgical decompression of the carpal canal is the treatment of choice.  相似文献   

18.
AIM OF THE STUDY: To verify changes of pulmonary venous flow pattern before and after surgical or percutaneous correction of valvular heart disease. METHODS: The pulmonary venous flow pattern was studied by transesophageal echocardiography in 27 patients affected with heart valve disease (11 mitral insufficiency, 10 mitral stenosis, 2 aortic stenosis and 4 pulmonary stenosis), before and after surgical or percutaneous correction. Pulmonary venous flow velocity variables measured included peak systolic and diastolic flow velocities (VmaxS and VmaxD), systolic and diastolic velocity time integrals (IS and ID) and their respective ratios (VmaxS/VmaxD and IS/ID). Paired Student's t-test was used for analysis of data; a p value < 0.05 was considered statistically significant. RESULTS: In mitral stenosis and insufficiency, as well as in pulmonary stenosis, the VmaxS/VmaxD and IS/ID ratios were constantly < 1. Aortic stenosis, on the contrary, showed a normal preoperative pattern of pulmonary venous flow, which did not change after correction. All other successful corrections (17 surgeries, 4 angioplasties) were characterised by an increase of VmaxS/VmaxD and IS/ID ratios. (Mitral stenosis: VmaxS/VmaxD 0.80 +/- 0.31 vs 1.4 +/- 0.5, p = 0.006; IS/ID 0.86 +/- 0.77 vs 1.62 +/- 0.62, p = 0.016. Severe mitral insufficiency: VmaxS/VmaxD -0.71 +/- 0.32 vs 1.19 +/- 0.32, p < 0.0001; IS/ID 0.41 +/- 0.19 vs 1.04 +/- 0.31, p = 0.006. Moderate mitral insufficiency: VmaxS/Vmax D 0.38 +/- 0.04 vs 0.95 +/- 0.06, p = 0.001; IS/ID 0.32 +/- 0.05 vs 0.95 +/- 0.07, p = 0.02. Pulmonary stenosis: VmaxS/VmaxD 0.43 +/- 0.23 vs 1.09 +/- 0.35, n.s. e IS/ID 0.49 +/- 0.34 vs 0.92 +/- 0.65, n.s.). Failure to return to a normal pulmonary venous pattern was observed in the 2 cases of partially successful mitral valvuloplasty (one of which was subsequently transformed into a mitral valve replacement with immediate normalisation of the pattern) and in the 2 cases of incomplete relief of a pulmonary stenosis after pulmonary valvuloplasty. CONCLUSIONS: Though preliminary, these observations suggest a high sensitivity of this method and, therefore, a possible role of pulmonary venous pattern studies in the assessment of the efficacy of treatment in mitral and pulmonary valve disease.  相似文献   

19.
BACKGROUND: Left internal mammary artery Doppler flow velocity assessment during the Azoulay maneuver (patient's legs are passively lifted up and actively maintained by the patient) can increase the information on the anastomosis quality after left internal mammary artery to left anterior descending coronary artery grafting after the left anterior, small thoracotomy operation. METHODS: One hundred patients had an early postoperative angiography and a Doppler flow velocity assessment at rest and during the Azoulay maneuver. Peak and mean systolic velocities, peak and mean diastolic velocities, and peak and mean diastolic to systolic velocity ratios were recorded in all patients. RESULTS: In 95 patients with no restrictive conduit or anastomosis, peak and mean diastolic to systolic velocity ratios increased during the Azoulay maneuver; all but 1 patient showed at least one ratio equal to or greater than 1. In 4 patients with restrictive conduit or anastomosis, peak and mean diastolic to systolic velocity ratios were always less than 1 during the Azoulay maneuver. In the patient with an occluded conduit these ratios were less than 0.6. CONCLUSIONS: Peak and mean diastolic to systolic velocity ratios less than 1 during the Azoulay maneuver are suggestive of conduit or anastomosis malfunction. If we limit the angiographic controls to these patients, it is very likely that a pathologic anastomosis or conduit will not be missed.  相似文献   

20.
BACKGROUND: Left atrial spontaneous echo contrast (LASEC), a putative marker of thrombo-embolic risk, is commonly located in the left atrial appendage (LAA). The aims of this work were to evaluate, using multiplane transesophageal echography, the echocardiographic determinants, specifically LAA outflow Doppler velocity, in the presence of SEC in patients with rheumatic MS. METHODS: Transthoracic and transesophageal echocardiographic tests were performed on 61 patients. The patients were divided into 3 groups based on the presence and type of valvular disease. Patients in group I (n = 28) presented with rheumatic mitral stenosis (MS). Patients in group II (n = 18) presented with valvular heart disease other than MS, and patients in group III (n = 15) had no history of valvular heart disease. The left atrium and appendage were examined for the presence of spontaneous echocontrast and thrombus, using multiplane echo scopy with transducer rotation. Minimal and maximal appendage areas were measured, on a computer-assisted bablet, by tracing a line from the top of the limbus of the left upper pulmonary vein to the appendage endocardial border. The LAA ejection fraction was calculated according to the formula: (maximal area-minimal area)/maximal area. Mitral valvular condition was evaluated with transthoracic and transesophageal echocardiography. Left atrial appendage blood flow velocity profiles were obtained with pulsed-wave Doppler at the orifice of the LAA. RESULTS: LASEC was present in 18 of 28 patients with mitral stenosis (64.3%). Patients with LASEC showed a greater incidence of atrial fibrillation (14/18 vs 12/43, p < 0.005), larger LAD (53.67 +/- 8.74 vs 40.54 +/- 14.85, p < 0.005), smaller LAAEF (38.7 +/- 1.53 vs 69.5 +/- 24.0, p < 0.05), smaller LAAMEV (20.28 +/- 10.07 vs 2.95 +/- 25.11, p < 0.005) and smaller LAAMFV (24.6 +/- 12.23 vs 36.00 +/- 11.01, p < 0.01), when compared with patients without LASEC. For group I, LAAEF, LAAMEV and LAAFV were smaller in patients with SEC than in patients without SEC (p < 0.005, p < 0.05, p < 0.01). However LAD values were similar for patients with and without SEC (53.67 +/- 8.75 vs 54.20 +/- 18.81, p = NS). Both LAAMEV and LAAMFV were related to SEC in patients with atrial fibrillation. However, LAD did not show the same trend. CONCLUSIONS: LASEC is more commonly observed in patients with rheumatic mitral stenosis or atrial fibrillation. Both LAAMEV and LAAMFV are associated with SEC in these patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号