首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
空气曝气与纯氧曝气生物滤池应用于污水深度处理的研究   总被引:3,自引:2,他引:3  
采用两种不同气源的曝气生物滤池对污水处理厂二级出水进行深度处理中试研究.结果表明,空气曝气和纯氧曝气生物滤池对COD_(Mn)的去除率相近,分别为30.5%和30.9%;以纯氧为气源的生物滤池硝化能力远强于空气曝气生物滤池,氨氮总去除率77.4%,出水氨氮为2.1~6.3 mg/L;纯氧曝气提高了滤池上部氨氮去除效果,维持滤池内溶解氧在6 mg/L以上,沿水流方向使pH逐渐下降.纯氧曝气生物滤池是污水深度处理中去除氨氮的有效工艺.  相似文献   

2.
不同填料曝气生物滤池启动挂膜试验研究   总被引:1,自引:0,他引:1  
不同填料曝气生物滤池在相同条件下进行挂膜试验。进水流向为上流式,挂膜方式为复合接种挂膜,即先用活性污泥闷曝接种,然后逐步提高进水流速,直到滤料表面形成稳定的生物膜。结果表明:33 d后挂膜成功,在温度为16~24℃,水力停留时间(HRT)为1 h,DO为6 mg/L的情况下,陶粒BAF对CODMn和NH3—N的去除率分别为23%和80%;沸石BAF的去除率分别为27%和84%;组合填料BAF去除效果最好,去除率分别为32%和92%。  相似文献   

3.
Aerobic biological treatment of digested sludge was studied in a continuously operated laboratory set-up. An aerated reactor was filled with thermophilically digested sludge from the Moscow wastewater treatment plant and inoculated with special activated sludge. It was then operated at the chemostat mode at different flow rates. Processes of nitrification and denitrification, as well as dephosphatation, occurred simultaneously during biological aerobic treatment of thermophilically digested sludge. Under optimal conditions, organic matter degradation was 9.6%, the concentrations of ammonium nitrogen and phosphate decreased by 89 and 83%, respectively, while COD decreased by 12%. Dewaterability of digested sludge improved significantly. The processes were found to depend on hydraulic retention time, oxygen regime, and temperature. The optimal conditions were as follows: hydraulic retention time 3-4 days, temperature 30-35 degrees C, dissolved oxygen levels 0.2-0.5 mg/L at continuous aeration or 0.7-1 mg/L at intermittent aeration. Based on these findings, we propose a new combined technology of wastewater sludge treatment. The technology combines two stages: anaerobic digestion followed by aerobic biological treatment of digested sludge. The proposed technology makes it possible to degrade the sludge with conversion of approximately 45% volatile suspended solids to biogas, to improve nitrogen and phosphorus removal in reject water from sludge treatment units, and to achieve removal of malodorous substances after 8-9 days of anaerobic-aerobic sludge treatment.  相似文献   

4.
Nitrification is a key step for reliable biological nitrogen removal. In order to enhance nitrification in the activated sludge (AS) process, membrane-attached biofilm (MAB) was incorporated in a conventional activated sludge tank. Simultaneous organic carbon removal and nitrification of the MAB incorporated activated sludge (AS + MAB) process was investigated with continuous wastewater treatment. The effluent TOC concentration of AS and the AS + MAB processes were about 6.3 mg/L and 7.9 mg/L, respectively. The TOC removal efficiency of both AS and AS + MAB were above 95% during the wastewater treatment, indicating excellent organic carbon removal performance in both processes. Little nitrification occurred in the AS process. On the contrary, successful nitrification was obtained with the AS + MAB process with nitrification efficiency of about 90%. The volumetric and surface nitrification rates were about 0.14 g/Ld and 6.5 g/m2d, respectively. The results clearly demonstrated that nitrification in the conventional AS process was boosted by MAB. Furthermore, the microfaunal population in the AS + MAB process was different from that in the AS process. The high concentration of rotifers in the AS + MAB process was expected to decrease the generation of excess sludge in the process.  相似文献   

5.
Boras wastewater treatment plant is being upgraded to comply with the new effluent standards for nitrogen. Three different configurations have been tested in parallel in full scale in the existing activated sludge plant The Biodenitro operated line showed the best performance because of the flexible adjustment of the nitrification and denitrification capacity. The adjustment was made off-line with the aid of continuous ammonia and nitrate measurements. On-line sensors are now installed permanently at Boris wastewater treatment plant and will be used for on-line dynamic control of the nitrogen removal in a Biodenitro configuration. The plant capacity will be further increased by Killing in the aeration tanks in situations with high hydraulic load.  相似文献   

6.
With a view to a reduction of the discharge from combined water outflow, the increase of the influent to a wastewater treatment plant can be an efficient solution, for cases in which the discharge concentration of the wastewater treatment plant would not deteriorate significantly as a result. Through bypassing the aeration with combined water and a direct feed of the combined water into the final clarification (Mina-Process) the specific sludge volume loading, which is significant to the efficiency of the final clarification, will not be raised. But the adsorption capability of the aerated sludge, the sedimentation effect of the final clarification, and the partial recirculation over return-sludge can be used for an elimination of suspended solids, chemical oxygen demand (COD), ammonia and phosphate from the combined wastewater. In large-scale tests in Wilhelmshaven (160,000 PE), removal efficiencies for the elimination in the bypass of 75% of COD, 60% of ammonia and 89% of suspended solids were reached. In comparison with conventional procedures for combined water treatment (e.g. storage volumes, soil filter) the Mina-Process has the possibility to achieve a highly efficient and economical combined water treatment by using the capability of existing clarifiers.  相似文献   

7.
The South-Budapest Wastewater Treatment Plant (SBWWTP) had been operated as a high-load activated sludge (AS) plant since the middle of the 60s. According to the requirements proposed by the water authorities the treatment process had to be upgraded into nutrient (phosphorus and nitrogen) removal. The upgrade of the plant comprised implementation of BIOFOR type nitrifying (NP) and post-denitrifying (DN) biofilters downstream of the AS stage. Phosphorus removal was obtained by chemical precipitation that can be done at five different points for feeding ferric-sulfate (Fe2(SO4)3). Partial flow recirculation was administered from the nitrifying BIOFOR unit ahead of the AS basin for pre-denitrification utilizing raw wastewater as carbon source. The plant performance was monitored since the test operation period for 25 months. Experience revealed that significant nitrification occurs in the high-load activated sludge basin originally designed for carbon removal. During the summer period (characterized by temperature of 20-25 degrees C) about 37-42% ammonium conversion rate was observed in the reactor. The decreasing temperature in the wintertime resulted in lower nitrification rates, of about 6-10%. The combined activated sludge-biofiltration process proved its viability in the removal of organic matter, nitrogen and phosphorus. In this special configuration the AS system plays a key role in the nitrogen and organic matter removal.  相似文献   

8.
Wastewater treatment systems using bio-films that grow attached to a support media are an alternative to the widely used suspended growth activated sludge process. Different fixed growth biofilm reactors are commercially used for the treatment of municipal as well as industrial wastewater. In this paper a fairly new fixed growth biofilm system, the submerged fixed bed biofilm reactor (SFBBR), is discussed. SFBBRs are based on aerated submerged fixed open structured plastic media for the support of the biofilm. They are generally operated without sludge recirculation in order to avoid clogging of the support media and problems with the control of the biofilm. Reactor and process design considerations for these reactors are reviewed. Measures to ensure the development and maintenance of an active biofilm are examined. SFBBRs have been applied successfully to small wastewater treatment plants where complete nitrification but no high degree of denitrification is necessary. For the pre-treatment of industrial wastewater the use of SFBBRs is advantageous, especially in cases of wastewater with high organic loading or high content of compounds with low biodegradability. Performance data from exemplary commercial plants are given. Ongoing research and development efforts aim at achieving a high simultaneous total nitrogen (TN) removal of aerated SFBBRs and at improving the efficiency of TN removal in anoxic SFBBRs.  相似文献   

9.
The effect of rain events on effluent quality dynamics was studied at a full scale activated sludge wastewater treatment plant which has a process solution incorporating pre-denitrification in activated sludge with post-nitrification in trickling filters. The incoming wastewater flow varies significantly due to a combined sewer system. Changed flow conditions have an impact on the whole treatment process since the recirculation to the trickling filters is set by the hydraulic limitations of the secondary settlers. Apart from causing different hydraulic conditions in the plant, increased flow due to rain or snow-melting, changes the properties of the incoming wastewater which affects process performance and effluent quality, especially the particle removal efficiency. A comprehensive set of on-line and laboratory data were collected and analysed to assess the impact of rain events on the plant performance.  相似文献   

10.
At a large Austrian municipal wastewater treatment plant enhanced stabilisation of anaerobically digested sewage sludge was required in order to get a permit for landfill disposal of the dewatered stabilized sludge. By implementing a post-aeration treatment after anaerobic digestion the organic content of the anaerobically well digested sludge can be decreased by 16%. Investigations at this plant showed that during digested sludge post-aeration anoxic phases are needed to provide stable process conditions. In this way the pH value can be kept in a more favourable range for micro-organisms and concrete structures. Additionally, under the process conditions applied nitrite accumulation would inhibit the stabilisation process if denitrification is not adequately applied. By optimising the aeration/pause ratio approximately 45% of total nitrogen in digested sludge can be removed. NH4-removal occurs through nitrification and denitrification with an efficiency of 98%. This significantly improves nitrogen removal efficiency at the wastewater treatment plant. The costs/benefit analysis shows that post-aeration of digested sludge results in an increase of total annual costs for wastewater treatment of only 0.84%, corresponding to 0.19 Euro/pe/a. Specific costs for nitrogen removal (0.32 Euro/kgN) are comparable with other biological processes for N-removal in reject water.  相似文献   

11.
Sewage plants can experience dimethyl sulphide (DMS) odour problems by at least one mg/L dimethylsulphoxide (DMSO) waste residue in plant influent, through a DMSO/DMS reduction mechanism. This bench-scale batch study simulates in bottles the role of poor aeration in wastewater treatment on the DMSO/DMS and sulphate/H2S reduction. The study compares headspace concentrations of sulphide odorants developed by activated sludge (closed bottles, half full) after six hours under anoxic versus anaerobic conditions, with 0 versus 2 mg/L DMSO addition. Anoxic sludge (0.1 - 2 mg/L dissolved oxygen, DO) with DMSO resulted in about 50 ppmv DMS and no other sulphide, while DMSO-free sludge was free of detectable sulphides. Anaerobic sludge (no measurable DO to the point of sulphate reduction) with DMSO resulted in 22/4/37 ppmv of H2S/methanethiol (MT)/DMS, while DMSO-free sludge resulted in 44/8/2 ppmv of H2S/MT/DMS. It is concluded that common "anoxic" aeration tank zones with measurable DO in bulk water but immeasurable DO inside sludge flocs (nitrate reducing) experience DMSO reduction to DMS that is oxidation resistant and becomes the most important odorant. Under anaerobic conditions, H2S from sulphate reduction becomes an additional important odorant. A strategy is developed that allows operators to determine from the quantity of different sulphides whether the DMSO/DMS mechanism is important at their wastewater plant.  相似文献   

12.
The Rya WWTP in Göteborg, Sweden is a highly loaded activated sludge plant which has been upgraded to remove nitrogen and to increase the biologically treated flow by 33% to reduce bypassing. Severe site restrictions made it difficult to increase the plant area. This was solved using a compact process based on tertiary nitrification in trickling filters and recirculation to a highly loaded activated sludge unit for denitrification. The necessary volumes were achieved by expanding the plant upwards, thus making it possible to place the trickling filters a in part of the area occupied by the former aeration basins. The recirculation of trickling filter effluent made it necessary to double the secondary settler capacity. This was solved by retrofitting the existing settlers as stacked settlers with a second tray on top of the original basin. The considerations behind process selection and plant design and costs are described.  相似文献   

13.
曝气生物滤池(BAF)用于建筑中水处理试验研究   总被引:1,自引:0,他引:1  
曝气生物滤池是一种介于生物接触氧化法与生物流化床之间的生物膜污水处理工艺,其紧凑性、能耗及运行维护亦介于两者之间,非常适合用于建筑中水处理。为检验曝气生物滤池处理建筑中水的性能,分别采用人工配水和洗浴废水进行了试验测定和实际验证。验证试验表明,经曝气生物滤池处理后的洗浴废水几乎不需任何后续处理(混凝、沉淀、过滤)便可满足中水回用标准要求。  相似文献   

14.
间歇曝气氧化沟工艺脱氮除磷和节能研究   总被引:3,自引:0,他引:3  
为了降低氧化沟工艺的运行能耗,采用连续进水间歇曝气的运行方式对某中型氧化沟工艺污水处理厂进行了改造研究.该方式将硝化菌控制在硝化动力学的高效率段,提高了硝化菌的硝化效率,降低了曝气能耗;有效避免了过量曝气,从而降低了出水NO-3-N的浓度,NO-3-N对厌氧区释放磷的影响同时降低,提高了生物除磷效率.研究表明:采用间歇曝气的运行方式,使污水处理厂在出水NH3-N达标的基础上,提高了TN和TP的去除率;经过改造该污水处理厂TN和TP的去除率分别由45%、35%提高到65%和84%;该工艺在不改变原有氧化沟污水处理厂基础设施的基础上,仅对运行方式进行优化调控,使全厂的平均电耗降低了21.5%.  相似文献   

15.
A new configuration of the moving-bed biofilm reactor process with pre-denitrification and nitrification was investigated in a pilot plant, which is fed with urban raw wastewater, the primary settler is located between the anoxic and the aerobic reactors, and primary sludge is recycled to the anoxic reactor as a hybrid pre-denitrification. The carriers used in the experiments are made of high-density polyethylene, with a diameter of 10 mm and a specific surface area of 400 m(2)/m(3). The new process was compared with conventional pre-denitrification-nitrification using in-series reactors fed with settled wastewater. The new configuration achieved an increase of 45% for the denitrification rate and of 30% for the nitrification rate when compared with conventional configuration. These results were analysed in light of the calibration study of the mixed-culture biofilm (MCB) model and simulations in AQUASIM 2.1 platform. Regarding denitrification, the high values obtained in the new configuration were attributed to a higher removal of the slowly biodegradable substrate (Xs) in the anoxic reactor due to the use of raw wastewater and sludge recycle. Accordingly, the amounts of heterotrophic biomass (XH) and Xs obtained in simulations were higher in both the biofilm and the bulk liquid. Regarding nitrification, the higher values were attributed to a lower removal of Xs in the aerobic reactors and accordingly, a lower accumulation of heterotrophic biomass in the biofilm was found in the simulations.  相似文献   

16.
Septic wastewater, characterised by the appearance of sulphide, is known to cause problems in sewage systems (corrosion and odour), at treatment plants (e.g. inhibition, sludge bulking) and for human beings (toxicity). Sulphide formation in sewers may be prevented by increasing the redox potential, either by oxygen/air injection (aerobic conditions) or dosage of nitrate (anoxic conditions). The effect on the nitrification capacity in a biofilm process of an anoxic wastewater as compared to a septic wastewater has been studied. The main change in wastewater quality as a result of nitrate dosage is reduced concentrations of organic matter and insignificant sulphide concentrations. The results show that a sulphide concentration of 0.5 mg/1 had a considerable negative effect on the nitrification activity. The sulphide and the higher concentrations of organic matter in the septic wastewater caused together a 30–40% reduction of the nitrification capacity as compared to the anoxic wastewater, even with pre-aeration and pre-precipitation with Fe3+. The removal of organic matter in the sewer as a result of the anoxic conditions created by the addition of nitrate, resulted in a maximum nitrification capacity when particulate organic matter was removed by pre-precipitation.  相似文献   

17.
A 104-mm (4-inch) diameter pilot-scale biological aerated filter (BAF) with a media depth of 2.5 m (8.3 feet) was operated with an anaerobic, anoxic and oxic zone at a temperature of 23 degrees C. The medium for the anaerobic and anoxic zones was 10 mm diameter sand while the medium for the oxic zone was 5 mm diameter sand. The influent sCOD and total nitrogen concentrations in the feedwater were approximately 250 mg/L and 35 mg N/L, respectively. sCOD removal at optimum hydraulic retention time (HRT) of 3 h with recirculation rates of 100, 200 and 300% in the column was above 96%. Nitrification was found to be more than 96% for 3 h HRT at 200 and 300% recirculation. Total nitrogen removal was consistent at more than 80% for 4 and 6 h HRT at 300% recirculation. For 3 h HRT and 300% recirculation, total nitrogen removal was approximately 79%. The ammonia loading rates for maximum ammonia removed were 0.15 and 0.19 kg NH3-N/m3-day for 100 and 200% recirculation, respectively. The experimental results demonstrated that the BAF can be operated at an HRT of 3h with 200-300% recirculation rates with more than 96% removal of sCOD and ammonia and at least 75% removal of total nitrogen.  相似文献   

18.
Installing membranes for solid-liquid separation into biological nutrient removal (BNR) activated sludge (AS) systems makes a profound difference not only to the design of the membrane bio-reactor (MBR) BNR system itself, but also to the design approach for the whole wastewater treatment plant (WWTP). In multi-zone BNR systems with membranes in the aerobic reactor and fixed volumes for the anaerobic, anoxic and aerobic zones (i.e. fixed volume fractions), the mass fractions can be controlled (within a range) with the inter-reactor recycle ratios. This zone mass fraction flexibility is a significant advantage of MBR BNR systems over BNR systems with secondary settling tanks (SSTs), because it allows changing the mass fractions to optimise biological N and P removal in conformity with influent wastewater characteristics and the effluent N and P concentrations required. For PWWF/ADWF ratios (fq) in the upper range (fq approximately 2.0), aerobic mass fractions in the lower range (f(maer) < 0.60) and high (usually raw) wastewater strengths, the indicated mode of operation of MBR BNR systems is as extended aeration WWTPs (no primary settling and long sludge age). However, the volume reduction compared with equivalent BNR systems with SSTs will not be large (40-60%), but the cost of the membranes can be offset against sludge thickening and stabilisation costs. Moving from a flow unbalanced raw wastewater system to a flow balanced (fq = 1) low (usually settled) wastewater strength system can double the ADWF capacity of the biological reactor, but the design approach of the WWTP changes away from extended aeration to include primary sludge stabilisation. The cost of primary sludge treatment then has to be offset against the savings of the increased WWTP capacity.  相似文献   

19.
TEMPEST is a new interactive simulation program for the estimation of the wastewater temperature in sewers. Intuitive graphical user interfaces assist the user in managing data, performing calculations and plotting results. The program calculates the dynamics and longitudinal spatial profiles of the wastewater temperature in sewer lines. Interactions between wastewater, sewer air and surrounding soil are modeled in TEMPEST by mass balance equations, rate expressions found in the literature and a new empirical model of the airflow in the sewer. TEMPEST was developed as a tool which can be applied in practice, i.e., it requires as few input data as possible. These data include the upstream wastewater discharge and temperature, geometric and hydraulic parameters of the sewer, material properties of the sewer pipe and surrounding soil, ambient conditions, and estimates of the capacity of openings for air exchange between sewer and environment. Based on a case study it is shown how TEMPEST can be applied to estimate the decrease of the downstream wastewater temperature caused by heat recovery from the sewer. Because the efficiency of nitrification strongly depends on the wastewater temperature, this application is of practical relevance for situations in which the sewer ends at a nitrifying wastewater treatment plant.  相似文献   

20.
曝气生物滤池升级改造中深度脱氮的试验研究   总被引:1,自引:0,他引:1  
某城市污水处理厂以曝气生物滤池(BAF)为主要处理工艺,现面临升级改造。设计处理水量2m3/d的中试装置,分别进行前置反硝化和以甲醇为碳源的后置反硝化试验研究,并优化各处理单元的运行参数。其中前置反硝化工艺回流比为125%,单池水力停留时间为20min,CN池和N池的气水比分别为4∶1和3∶1,后置反硝化工艺的水力停留时间为45min,CN池和N池的气水比分别为6∶1和5∶1,甲醇投加量为30mg/L。通过核算建设成本与运行费用,推荐了以前置反硝化为核心的升级改造方案。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号