首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We report a new method called metal affinity capture that when coupled with tandem mass spectrometry (MAC-MSMS) allows for the selective detection and identification of phosphopeptides in complex mixtures. Phosphopeptides are captured as ternary complexes with Ga(III) or Fe(III) and N(alpha),N(alpha)-bis(carboxymethyl)lysine (LysNTA) in solution and electrosprayed as doubly or triply charged positive ions. The gas-phase complexes uniformly dissociate to produce a common (LysNTA + H)+ ion that is used as a specific marker in precursor ion scans. The advantages of MAC-MSMS over the current methods of phosphopeptide detection are as follows. (1) MAC-MSMS uses metal complexes that self-assemble in solution at pH <5, which is favorable for the production of positive ions by electrospray. (2) Phosphorylation at tyrosine, serine, and threonine is detected by MAC-MSMS. (3) The phosphopeptide peaks in the mass spectra are encoded with the 69Ga-71Ga isotope pattern for selective recognition in mixtures. Detection by MAC-MSMS of singly and multiply phosphorylated peptides in tryptic digests is demonstrated at low-nanomolar protein concentrations.  相似文献   

2.
Due to its strong ultraviolet absorption, high salt tolerance, and little interference in the low molecular weight region, N-(1-naphthyl) ethylenediamine dihydrochloride (NEDC) has been applied as a matrix to measure the level of glucose in rat brain microdialysates by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) in combination with in vivo microdialysis. By monitoring the ion signals of (glucose + Cl)(-) in the mass spectra, we achieved a low detection limit of ~10 μM for glucose in 126 mM NaCl, which is a typical component in artificial cerebrospinal fluid, without prior sample purification. It is concluded that NEDC-assisted laser desorption/ionization (LDI) MS is a fast and general method for sensitive detection of small molecules (such as glucose and amino acids) in high ionic strength solutions.  相似文献   

3.
A high-throughput method for sequencing of N termini of proteins by using postsource decay (PSD) of matrix-assisted laser desorption/ionization mass spectrometry has been developed. After a protein blotted on the PVDF membrane was successively reduced, S-alkylated, and guanidinated, its N-amino group was coupled to biotinylcysteic acid. The protein was then extracted from the membrane and digested with trypsin. The derivatized N-terminal fragment was then specifically isolated from the tryptic digest with avidin resins, and its de novo sequencing was successfully performed by PSD utilizing a sulfonic acid group introduced to the N terminus.  相似文献   

4.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) combines information-rich chemical detection with spatial localization of analytes. For a given instrumental platform and analyte class, the data acquired can represent a compromise between analyte extraction and spatial information. Here, we introduce an improvement to the spatial resolution achievable with MALDI MSI conducted with standard mass spectrometric systems that also reduces analyte migration during matrix application. Tissue is placed directly on a stretchable membrane that, when stretched, fragments the tissue into micrometer-sized pieces. Scanning electron microscopy analysis shows that this process produces fairly homogeneous distributions of small tissue fragments separated and surrounded by areas of hydrophobic membrane surface. MALDI matrix is then applied by either a robotic microspotter or an artist's airbrush. Rat spinal cord samples imaged with an instrumental resolution of 50-250 μm demonstrate lipid distributions with a 5-fold high spatial resolution (a 25-fold increase in pixel density) after stretching compared to tissues that were not stretched.  相似文献   

5.
An atmospheric pressure (AP) MALDI imaging interface was developed for an orthogonal acceleration time-of-flight mass spectrometer and utilized to analyze peptides, carbohydrates, and other small biomolecules using infrared laser excitation. In molecular imaging experiments, the spatial distribution of mock peptide patterns was recovered with a detection limit of approximately 1 fmol/pixel from a variety of MALDI matrixes. With the use of oversampling for the image acquisition, a spatial resolution of 40 microm, 5 times smaller than the laser spot size, was achieved. This approach, however, required that the analyte was largely removed at the point of analysis before the next point was interrogated. Native water in plant tissue was demonstrated to be an efficient natural matrix for AP infrared laser desorption ionization. In soft fruit tissues from bananas, grapes, and strawberries, potassiated ions of the most abundant metabolites, small carbohydrates, and their clusters produced the strongest peaks in the spectra. Molecular imaging of a strawberry skin sample revealed the distribution of the sucrose, glucose/fructose, and citric acid species around the embedded seeds. Infrared AP MALDI mass spectrometric imaging without the addition of an artificial matrix enables the in vivo investigation of small biomolecules and biological processes (e.g., metabolomics) in their natural environment.  相似文献   

6.
The rotating ball inlet (ROBIN) is presented in a new design for on-line matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS). This method uses a capillary to deliver a matrix and analyte solution to the surface of a rotating ball upon which MALDI is carried out. The ball is in contact with a polymer gasket surrounding the capillary. Sample adhering to the surface of the ball is dragged past the gasket into the vacuum of the mass spectrometer where it is irradiated by a pulsed UV laser, and the resulting ions are mass-separated in a linear time-of-flight mass spectrometer. The mechanical sample introduction prevents clogging of the vacuum interface by matrix crystals or frozen solvent. Preliminary results from flow injection analysis (FIA) suggest that the new interface does not introduce a significant peak-tailing or memory effect. The system is capable of 20-30 h of continuous operation with a flow rate of 2 microL/min before cleaning of the ball is needed. With the prototype inlet, concentration detection limits are at the low micromolar level.  相似文献   

7.
A matrix-assisted laser desorption ionization (MALDI) mass spectrometry-based approach is applied to identify active site domains within influenza neuraminidase that bind the antiviral inhibitors zanamivir (ZANA) and 2-deoxy-2,3-didehydro-N-acetylneuraminic acid (DANA). Combined data from the tryptic and Glu-C endoproteinase digests of neuraminidase-inhibitor complexes have identified binding peptides that contain the active site residues Arg118, Glu119, Arg156, Glu276, and Tyr406. The binding of these residues was confirmed from the analysis of available X-ray crystal structures. The ability to identify peptides within the active sites of proteins and likely binding residues provides both a rapid and relatively high throughput approach with which to screen protein-drug interactions by MALDI mass spectrometry.  相似文献   

8.
In-source decay (ISD) fragmentation as combined with matrix-assisted laser desorption/ionization (MALDI) mass spectrometry allows protein sequencing directly from mass spectra. Acquisition of MALDI-ISD mass spectra from tissue samples is achieved using an appropriate MALDI matrix, such as 1,5-diaminonaphthalene (DAN). Recent efforts have focused on combining MALDI-ISD with mass spectrometry imaging (MSI) to provide simultaneous sequencing and localization of proteins over a thin tissue surface. Successfully coupling these approaches requires the development of new data analysis tools, but first, investigating the properties of MALDI-ISD as applied to mixtures of protein standards reveals a high sensitivity to the relative protein ionization efficiency. This finding translates to the protein mixtures found in tissues and is used to inform the development of an analytical pipeline for data analysis in MALDI-ISD MS imaging, including software to identify the most pertinent spectra, to sequence protein mixtures, and to generate ion images for comparison with tissue morphology. The ability to simultaneously identify and localize proteins is demonstrated by using the analytical pipeline on three tissue sections from porcine eye lens, resulting in localizations for crystallins and cytochrome c. The variety of protein identifications provided by MALDI-ISD-MSI between tissue sections creates a discovery tool, and the analytical pipeline makes this process more efficient.  相似文献   

9.
The utility of atmospheric pressure infrared MALDI mass spectrometry (AP IR-MALDI) was assessed for plant metabolomics studies. Tissue sections from plant organs, including flowers, ovaries, aggregate fruits, fruits, leaves, tubers, bulbs, and seeds were studied in both positive and negative ion modes. For leaves, single laser pulses sampled the cuticle and upper epidermal cells, whereas multiple pulses were demonstrated to ablate some mesophyll layers. Tandem mass spectra were obtained with collision-activated dissociation to aid with the identification of some observed ions. In the positive mode, most ions were produced as potassium, proton, or sometimes sodium ion adducts, whereas proton loss was dominant in the negative ion mode. Over 50 small metabolites and various lipids were detected in the spectra including, for example, 7 of the 10 intermediates in the citric acid cycle. Key components of the glycolysis pathway occurring in the plant cytosol were found along with intermediates of phospholipid biosynthesis and reactants or products of amino acid, nucleotide, oligosaccharide, and flavonoid biosynthesis. AP IR-MALDI mass spectrometry was used to follow the fluid transport driven by transpiration and image the spatial distributions of several metabolites in a white lily (Lilium candidum) flower petal.  相似文献   

10.
The investigation of a MALDI triple quadrupole instrument for the analysis of spirolide toxins in phytoplankton samples is described in this study. A high-frequency (kHz) laser was employed for MALDI, generating a semicontinuous ion beam, thus taking advantage of the high duty cycle obtained in sensitive triple quadrupole MRM experiments. Initially, several experimental parameters such as type of organic matrix and concentration, solvent composition, and matrix-to-analyte ratio were optimized, and their impact on sensitivity and precision of the obtained ion currents for a reference spirolide, 13-desmethyl-C, was studied. In all quantitative experiments, excellent linearities in the concentration range between 0.01 and 1.75 microg/mL were obtained, with R2 values of 0.99 or higher. The average precision of the quantitative MALDI measurements was 7.4+/-2.4% RSD. No systematic errors were apparent with this method as shown by a direct comparison to an electrospray LC/MS/MS method. Most importantly, the MALDI technique was very fast; each sample spot was analyzed in less than 5 s as compared to several minutes with the electrospray assay. To demonstrate the potential of the MALDI triple quadrupole method, its application to quantitative analysis in several different phytoplankton samples was investigated, including crude extracts and samples from mass-triggered fractionation experiments. 13-Desmethyl spirolide C was successfully quantified in these complex samples at concentration levels from 0.05 to 90.4 microg/mL (prior to dilution to have samples fall within the dynamic range of the method) without extensive sample preparation steps. The versatility of the MALDI triple quadrupole method was also exhibited for the identification of unknown spirolide analogues. Through the use of dedicated linked scan functions such as precursor ion and neutral loss scans, several spirolide compounds were tentatively identified directly from the crude extract, without the usual time-consuming chromatographic preseparation steps. Moreover, high-quality CID spectra were obtained for low-abundant spirolides present in the phytoplankton samples.  相似文献   

11.
A new sample ionization technique, atmospheric pressure matrix-assisted laser desorption/ionization (AP MALDI), was coupled with a commercial ion trap mass spectrometer. This configuration enables the application-specific selection of external atmospheric ionization sources: the electrospray/APCI (commercially available) and AP MALDI (built in-house), which can be readily interchanged within minutes. The detection limit of the novel AP MALDI/ion trap is 10-50 fmol of analyte deposited on the target surface for a four-component mixture of peptides with 800-1700 molecular weight. The possibility of peptide structural analysis by MS/MS and MS3 experiments for AP MALDI-generated ions was demonstrated for the first time.  相似文献   

12.
The direct profiling of proteins present in tissue sections for several organs of the mouse has been accomplished using matrix-assisted laser desorption ionization (MALDI) mass spectrometry (MS). Fresh tissue was sectioned and blotted on a conductive polyethylene membrane. The dried membrane blot was coated with matrix, typically sinapinic acid, and directly analyzed in the mass spectrometer. Generally, well over 100 peptide/protein signals in the 2000-30,000 Da range were observed, with 30-50 having relatively high signal intensities. Analysis of different areas of the same tissue gave remarkably similar mass spectra with greater than 90% homology. However, different parts of a segmented tissue, such as the proximal, intermediate, and distal colon, gave some unique protein signals. After treatment of the tissue blot with protease and subsequent MALDI MS analysis using postsource decay methods for peptide sequencing, some of the proteins were identified. The unique protein profiles measured from these tissue blots also showed differences from strain to strain of the mouse, with genetically similar strains having very similar patterns.  相似文献   

13.
Bahr U  Aygün H  Karas M 《Analytical chemistry》2008,80(16):6280-6285
While MALDI-MS is widely accepted for quality control of synthetic oligonucleotides, this method has been regarded as not applicable for a control of the purity and correct annealing of double strands. The results presented here show that the double-strand intensities measured by MALDI-MS maintain and reflect the solution conditions. Using a single-stranded RNA as internal standard, the double-strand intensity can be determined by measuring the intensity ratio of the single strands to the standard under "native" conditions and after denaturation with formic acid. For siRNAs with fully matched 20-21 base pairs, relative intensities of the double strands are between 94 and 97.2%. The stability determined by MALDI-MS for different RNA duplexes correlates well with calculated T m values and the content of G-C pairs. Furthermore, the quantification method enables one to determine an excess of one single strand and the contribution of duplex formation by truncated strands. The results show that MALDI-MS is a fast and reliable method for quality control of synthetic siRNA.  相似文献   

14.
Kim TY  Brun YV  Reilly JP 《Analytical chemistry》2005,77(13):4185-4193
The effect of esterification on MALDI ion yield is investigated by using alcohols having different aliphatic chain lengths. For peptides whose ionization yields increase with derivatization, more hydrophobic alcohols tend to yield greater peak enhancements. The completeness of the reaction increases from propanol to methanol. Undesired solvolysis of the amide group in the side chain of Asn or Gln leads to unexpected ester products. Ethanol is suggested as the optimal alcohol for esterification in proteomics experiments since it yields almost complete esterification without substantial solvolysis. Ethanol esterification was employed to facilitate the identification of gel-separated proteins.  相似文献   

15.
The design and operation of a microfluidic device for sample preparation in MALDI mass spectrometry of peptides and proteins is described. It is particularly useful for proteomics applications and for mass determination of proteins in salt- and detergent-containing solutions. The system consists of a flow channel with two conductive areas or electrical junctions where proteins and peptides are retained by means of an electric field. The microfluidic device is made of PEEK tubing, and the junctions are covered with a conductive polymeric membrane. A syringe pump connected to the device produces a flow stream, and injection of sample is carried out manually via hydrodynamic pressure. Proteolytic peptides and intact proteins in salt- and detergent-containing acidic media were captured at the cathode junction followed by exchange of the original solution to a solvent suitable for subsequent mass spectrometry. Using this principle, a significant desalting effect was obtained for tryptic peptides in mass-mapping experiments. Protein sequence coverages were high (up to 40%) at subpicomole levels with results better than those obtained using reversed-phase solid-phase extraction. In contrast to the latter technique, the microfluidic device has the capacity to efficiently remove detergents such as CHAPS before peptide mapping and protein analysis.  相似文献   

16.
A new method for improving low-concentration sample recovery and reducing sample preparation steps in matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) is presented. In the conventional approach, samples are typically desalted and/or concentrated with various techniques and deposited on the MALDI target as small droplets. In this work, we describe a new approach in which an elastomeric device is reversibly sealed on the MALDI target to form a multi-well plate with the MALDI target as the base of the plate. The new format allows a larger volume (5-200 microL) of samples to be deposited on each spot and a series of sample handling processes, including desalting and concentrating, to be performed directly on the MALDI target. Several advantages have been observed: (i) multiple sample transferring steps are avoided; (ii) recovery of low-concentration peptides during sample preparation is improved using a novel desalting method that utilizes the hydrophobic surface of the elastomeric device; and (iii) sequence coverage of the peptide mass fingerprinting map is improved using a novel method in which proteins are immobilized on the hydrophobic surface of the elastomeric device for in-well trypsin digestion, followed by desalting and concentrating the digestion products in the same well.  相似文献   

17.
Surface modification of MALDI probes is an attractive approach for combining bioaffinity isolation of targeted biomolecules with mass spectrometric analysis of the captured species. In this work, we demonstrate that a polymer thin film, produced by pulsed rf plasma polymerization of allylamine and deposited directly on a MALDI probe, can be subsequently biotinylated to develop a bioaffinity capture MALDI probe. The synthesis and characterization of the probe by XPS, FT-IR, and AFM is described, and the selective isolation of avidin from a three-component mixture of avidin, lysozyme, and cytochrome c is presented. These initial results offer encouragement for the further exploration of rf plasma polymer deposition as a novel approach for the development of on-probe affinity capture MALDI probes.  相似文献   

18.
Imaging mass spectrometry (IMS) that utilizes matrix-assisted laser desorption/ionization (MALDI) technology can provide a molecular ex vivo view of resected organs or whole-body sections from an animal, making possible the label-free tracking of both endogenous and exogenous compounds with spatial resolution and molecular specificity. Drug distribution and, for the first time, individual metabolite distributions within whole-body tissue sections can be detected simultaneously at various time points following drug administration. IMS analysis of tissues from 8 mg/kg olanzapine dosed rats revealed temporal distribution of the drug and metabolites that correlate to previous quantitative whole-body autoradiography studies. Whole-body MALDI IMS is further extended to detecting proteins from organs present in a whole-body sagittal tissue section. This technology will significantly help advance the analysis of novel therapeutics and may provide deeper insight into therapeutic and toxicological processes, revealing at the molecular level the cause of efficacy or side effects often associated with drug administration.  相似文献   

19.
Presented are initial results from the first commercially available matrix-assisted laser desorption/ionization time-of-flight mass spectrometer specifically designed for the sensitive detection of very high mass ions (macromizer, Comet AG). This new instrument utilizes a 16-element superconducting tunnel junction detector coupled with a fully adjustable gimbal-mounted ion source/focusing region that allows unparalleled sensitivity for detection of singly charged high molecular weight ions. Using this new technology, the singly charged ions in the megadalton region are detected from immunoglobulin M and von Willebrand factor proteins. This detector technology also measures the kinetic energy of the particles impacting the detector, which can be correlated to the charge of the particles. Immunoglobulin G and streptavidin were used to demonstrate the ability of the macromizer instrument to detect high-mass ions and to discern the charge state of the ions.  相似文献   

20.
Time-course MALDI mass spectrometry immunoassays have been shown to be able to detect differences in the relative rates of binding of peptides, both from within and across epitopic domains, with antibodies in non-competitive and competitive experiments. A monoclonal antibody raised to target the HA1 subunit of the hemagglutinin antigen of type A H3N2 influenza strains is found to recognize two epitopic peptides comprising residues 109-125 and 158-166 that likely form part of an extended discontinuous domain. Time-course experiments show the smaller peptide binds antibody at a rate that is 5-fold faster than that for the larger peptide. A shorter segment of this larger peptide, comprised of residues 119-125, is also found to bind at twice the rate of the extended peptide. Studies of modified peptide variants and synthetic variants of HA peptide 119-125 has enabled important contact residues to be identified whose accessibilities in the native protein are in accord with the mass spectrometry results.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号