首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The efficiency of low-flow solar systems is strongly influenced by the quality of the thermal stratification in the storage tank. The better a thermal stratification can be generated and maintained, the higher can be the yield of the solar system. Fluid mechanical charge systems are often used for this purpose, which cause, however, undesirable sucking effects. Therefore, the knowledge of the appearing fluid flows as well as the knowledge of the consequences of constructive changes are very important for the design of such charge systems. However, simulations with CFD (Computational Fluid Dynamics) are very costly and time-consuming. In this article a new and much simpler computation method is introduced making the determination of the individual fluid flows and the estimation of the effects of constructive changes possible. The computations can be carried out within short time. The comparison with CFD gives a qualitatively good agreement for a simple charge system. The results of a constructive modification of the charge system reducing the sucking effect are discussed. The remaining quantitative differences result from the discrepancies between the non-ideal behaviour of the real fluid and the model assumptions and point out improvement potentials.  相似文献   

2.
Ulrike Jordan  Simon Furbo   《Solar Energy》2005,78(2):291-300
Storage tanks with different cold water inlet devices for small Solar Domestic Hot Water (SDHW) systems are compared. The objective of the investigation is to reveal the impact of the cold water inlet device on the thermal stratification in two marketed tanks and to evaluate the possible enhancement in the annual system performance of small solar heating systems. Two different marketed inlet designs are compared, one connected to a small curved plate placed above the inlet tube, the other one connected to a much larger flat plate. The cold domestic water enters the stores in vertical direction from the bottom of the tanks. Temperature measurements were carried out for different operating conditions. It was shown that the thermal stratification inside the two tanks depends differently on the flow rate, the draw-off volume, as well as the initial temperature in the storage tank. To carry out system simulations, a multi-node storage model was used and expanded by an additional input variable to model the mixing behaviour depending on the operating conditions. The inlet device with a comparatively large plate compared to the less favourable design results in an increase of the solar fraction of about 1–3%-points in annual system simulations with a solar fraction of about 60% and fairly large domestic hot water flow rates. This corresponds to a reduction of the auxiliary energy supply of the solar heating system of about 3–7% (58–155 MJ/year) for the investigated solar domestic hot water system.  相似文献   

3.
In this brief note, we have experimentally measured the temperature stratification in a solar hot water storage tank resulting from a simulated solar heating load. Various modifications using a double chimney device that acts as a thermal diode were examined with the intent of maximizing temperature stratification. The greatest stratification was seen with a unique thermal diode arrangement named the express-elevator design, so-called for the direct hot water path from the bottom third of the tank to the top third.  相似文献   

4.
ICS solar systems with two water tanks   总被引:3,自引:0,他引:3  
Integrated collector storage (ICS) systems are compact solar water heaters, simple in construction, installation and operation. They are cheaper than flat plate thermosiphonic units, but their higher thermal losses make them suitable mainly for application in locations with favourable weather conditions. Aiming to the achievement of low system height and satisfactory water temperature stratification, new types of ICS systems with two horizontal cylindrical storage tanks, properly mounted in stationary CPC reflector troughs are suggested. The non-uniform distribution of solar radiation on the two absorbing surfaces is combined with the seasonal sun elevation, resulting to effective water heating. In addition, the inverted absorber concept design can be applied to ICS systems with two storage tanks. In this paper, we present the design and performance of double tank ICS solar systems, which are based on the combination of symmetric and asymmetric CPC reflectors with water storage tanks. The analytical equations of the collector geometry of all models are calculated with respect to the radius of the cylindrical water storage tank and the reflector rim angles. Experimental results for the variation of the water temperature inside storage tanks, the mean daily efficiency and the coefficient of thermal losses during night are given for all experimental models. The tests were performed without water draining and the results show that the double tank ICS systems are efficient in water temperature rise during day and satisfactory preservation of the hot water temperature during night, with the upper storage tank being more effective in performance in most of the studied models.  相似文献   

5.
A detailed numerical model for flat-plate solar thermal devices   总被引:1,自引:0,他引:1  
J. Cadafalch 《Solar Energy》2009,83(12):2157-2164
A one-dimensional transient numerical model for flat-plate solar thermal devices is here presented.The model permits the analysis of different configurations and components such as multiple-glazing, transparent insulation, air-gaps, surface coatings, opaque insulation and energy accumulation in water or PCM internal stores.In order to obtain information of practical interest, the solar thermal devices are modelled following virtual testing procedures in accordance to the experimental test methods described by European and International standards.This paper describes the basis of the model and shows some comparison of numerical and experimental data as an example of the validation process that has been carried out in order to assess the credibility of the numerical model. For simplicity, the explanation is restricted to standard multiple-glazed flat-plate collectors. The use of the model in other more complicated configurations as in transparently insulated covers or integrated collector storage devices with phase change materials will be presented in other separate papers.  相似文献   

6.
A general chart is developed for calculating the collector area required to provide a prescribed value of the annual load fraction for solar heating systems. The relationship between collector area and annual load fraction can then be easily obtained for specified collector design parameters, load and location. The construction of the chart is based on correlating data generated by the f-chart method. Data of 13 locations in the U.S.A. are considered. The good agreement of the results obtained by the present simple method and the f-chart for both space and combined space/domestic water heating proves that the two methods are almost of the same accuracy. Since the present chart is not location dependent and allows direct comparison of different collectors, it is a very valuable design aid for sizing and selecting solar collectors.  相似文献   

7.
This article compares seven different external DHW units, comprising flat plate heat exchanger and flow control, with a reference method for preparing hot water. These DHW units use different control methods. The objective of the study was to determine which methods are most effective in solar combisystems and to identify other factors that strongly influence the energy savings of the system. Five of the DHW units were judged to be of interest for the study because of their measured performance or the simplicity of their design. Of these, measurement data showed that two had the same control function although of different physical construction. Thus four DHW units were modelled in the simulation environment PRESIM/TRNSYS, parameters were identified from measured data, and annual simulations were performed with a number of parametric variations. Three of the DHW units performed significantly better than the reference system provided that they were sized correctly: microprocessor control with variable-speed pump; proportional controller with regulating valve; and a turbine pump. The most important design factors identified by the study were: the maximum possible primary flow, which needs to be suitable for the design hot water load profile; and ensuring a low temperature is returned to the store. The hot water load profile was also shown to strongly influence the energy savings, assuming that auxiliary heater’s thermostat is set so that the system just meets the worst-case discharge.  相似文献   

8.
A.C. de Keizer  K. Vajen 《Solar Energy》2011,85(7):1430-1439
This paper presents an overview, assessment and comparison of automated fault detection methods that check if solar heating systems are functioning correctly. Fault detection in solar thermal systems is important to minimize the time when the system is not functioning well, thereby ensuring an optimal energy (and economic) yield.During the past decades many systems have been monitored, mainly for scientific or demonstration projects by logging measurement data which was subsequently analysed by an expert. Automation of fault detection is necessary to reduce costs and minimize experts’ time needed for analysis of a system. An overview of existing fault detection approaches is given; these are evaluated and compared with a multi-criteria analysis.The only commercially available automated method, the Input-Output Controller, detects faults causing more than 20% energy loss in the solar loop. The function control approach is cheap without a heat meter, and only relies on few sensors to check how several components in the solar loop are functioning with algorithms. The approach developed at Kassel University checks how well a solar plant is functioning both with plausibility checks and with energy balances based on simulations. This method includes a larger part of the solar heating system and therefore requires more measurement equipment.Further research and application of several fault detection methods should improve the effectiveness and costs of these methods.  相似文献   

9.
Two types of ICS solar water heaters designed, constructed and tested. The systems consist of two cylindrical storage tanks, which are connected in series and are horizontally incorporated in a stationary asymmetric CPC type mirror. The efficient operation of the system is due to the thermal losses suppression of the two inverted cylindrical surfaces and the effective use of the two tanks during sunshine period. Low cost and durable materials are used to construct the systems. The mean daily efficiency and the thermal performance of the hot water storage during night are calculated from outdoor experimental data. The results show that the proposed ICS systems are efficient and suitable for practical use as DHW systems.  相似文献   

10.
The sizing of the solar installation of an individual dwelling is a problem which can be solved in many ways. The approach described in this paper is a simplified procedure of considerable interest. It requires only a small quantity of data and can be computed in a short time. The performance of this procedure was evaluated by a more complex sizing method based on detailed simulation. The simplified procedure was applied to the case of an individual dwelling using a solar collector field to produce domestic hot water and space heating. The building and the solar installation have then been modelled with the software TRNSYS 16 and their behaviour was simulated during a whole year. The results obtained are particularly close to the ones expected by the simplified sizing procedure.  相似文献   

11.
向太阳索取--中国太阳光-热与光-电应用现状与展望   总被引:9,自引:0,他引:9  
我国有丰富的太阳能资源,已有25年光-热研究历史。10年来,太阳热水系统的生产发展迅速。2002年各种太阳热水系统销售约1000万m^2,主要是获得生活热水,一些其他的应用正在研究与开发。光-电研究与开发已有30多年了,应用在卫星、灯塔和通信等领域。2002年一个巨大的国家项目“送电到乡”的实施,完成了17MWp,这加速了我国的光-电产业。  相似文献   

12.
In addition to the solar water heating (SWH) system, other domestic water heating systems used in Jordan were considered in terms of benefits and costs using the Analytic Hierarchy Process. In terms of cost, the SWH system was the least expensive. On a percentage basis, the SWH cost about 13% compared to the most expensive heating system, LPG, of about 28%. In terms of benefits, the SWH was also the most beneficial. Approximately, the SWH benefits were about 31%, while the least benefits were obtained from the kerosene water heating system, which is about 9%. By considering both cost and benefit (i.e. cost-to-benefit ratio), solar was also the least expensive, about 7%, with kerosene being the most expensive, over 30%.  相似文献   

13.
This paper presents a simple techno-economic model for a hybrid solar air-heating system based on water as the storage medium. The configuration of the system consists of a conventional solar air-heater, water tank for thermal storage, a unit which adjusts the higher air temperature (during peak sunshine hours) to the required limit (by mixing fresh air) and an arrangement for providing auxiliary energy if and when required. A thermostatically controlled electric heater is assumed to be the source of auxiliary energy, in the present calculations. In order to evaluate the performance of the system using the developed model numerical calculations have been made corresponding to the climate of Delhi, India. The calculations have been extended to obtain the optimized values of collector area and storage mass which correspond to the minimum value of useful energy. Numerical results show that the cost of useful energy obtained for optimized values of collector area and storage mass is much less than the cost of electrical heating.  相似文献   

14.
The objective of this work is to present the development of an automatic solar water heater (SWH) fault diagnosis system (FDS). The FDS system consists of a prediction module, a residual calculator and the diagnosis module. A data acquisition system measures the temperatures at four locations of the SWH system and the mean storage tank temperature. In the prediction module a number of artificial neural networks (ANN) are used, trained with values obtained from a TRNSYS model of a fault-free system operated with the typical meteorological year (TMY) for Nicosia, Cyprus and Paris, France. Thus, the neural networks are able to predict the fault-free temperatures under different environmental conditions. The input data to the ANNs are various weather parameters, the incidence angle, flow condition and one input temperature. The residual calculator receives both the current measurement data from the data acquisition system and the fault-free predictions from the prediction module. The system can predict three types of faults; collector faults and faults in insulation of the pipes connecting the collector with the storage tank and these are indicated with suitable labels. The system was validated by using input values representing various faults of the system.  相似文献   

15.
The thermal advantages by utilizing discharge from different levels in solar storage tanks are investigated, both for a small SDHW system and for a solar combisystem.The investigations showed that it is possible to increase the thermal performance of both types of systems by using two draw-off levels from the solar tanks instead of one draw-off level at a fixed position.The best position of the second draw-off level is in the middle or just above the middle of the tank. For the investigated small SDHW system with a realistic draw off hot water temperature of 40 °C and 45 °C and an auxiliary volume temperature of 50.5 °C the increase of the thermal performance by the second draw-off level is about 6%.For the investigated solar combisystem the increase in thermal performance by using one extra draw-off level, either for the domestic hot water heat exchanger or for the heating system, is about 3%, while an improvement of about 5% is possible by using a second draw-off level both for the domestic hot water heat exchanger and for the heating system.  相似文献   

16.
An analytical and experimental investigation of transient turbulent two-dimensional charging and discharging of a sensible heat storage tank has been conducted. Parametric studies showed that the turbulent mixing factor due to hydrodynamic disturbances at the inlet ports is the most significant item in the performance of thermal stratification storage tanks. Furthermore, the effect of the aspect ratio and convection at the walls in promoting stratification have been studied. Comparison with experimental data showed the capability of the present analytic approach to accommodate, with a satisfactory degree of accuracy, such problems.  相似文献   

17.
W. Saman  F. Bruno  E. Halawa 《Solar Energy》2005,78(2):341-349
The thermal performance of a phase change thermal storage unit is analysed and discussed. The storage unit is a component of a roof integrated solar heating system being developed for space heating of a home. The unit consists of several layers of phase change material (PCM) slabs with a melting temperature of 29 °C. Warm air delivered by a roof integrated collector is passed through the spaces between the PCM layers to charge the storage unit. The stored heat is utilised to heat ambient air before being admitted to a living space. The study is based on both experimental results and a theoretical two dimensional mathematical model of the PCM employed to analyse the transient thermal behaviour of the storage unit during the charge and discharge periods. The analysis takes into account the effects of sensible heat which exists when the initial temperature of the PCM is well below or above the melting point during melting or freezing. The significance of natural convection occurring inside the PCM on the heat transfer rate during melting which was previously suspected as the cause of faster melting process in one of the experiments is discussed. The results are compared with a previous analysis based on a one dimensional model which neglected the effect of sensible heat. A comparison with experimental results for a specific geometry is also made.  相似文献   

18.
This study investigates the load characteristics of heat pipe thermoelectric solar collector (HPTSC) in practice. Heat pipe thermoelectric solar collector converts the heat generated by the Sun directly into electrical energy and produces hot water as well. The maximum power in HPTSC is obtained when the internal resistance of the thermoelectric module is equal to the load resistance. It has been observed to be possible to produce both hot water and electricity by improving available solar collectors or producing new generation HPTSC. While it is possible to generate an electrical power of 160 W from a HPTSC of one square meter using the thermoelectric method, the power produced with an average photovoltaic panel with the same area is only 132 W. Accordingly, HPTSC is a superior alternative not only to available solar collectors, but also to available PV panels. HPTSC, involving three different technologies, is environmentally friendly and certainly a product that allows for more efficient use of solar energy.  相似文献   

19.
The effect of solar radiation availability on the performance of different solar heating systems has been studied. The systems include a solar water heater, passive solar houses and district solar heating systems with seasonal heat storage. Also, different collector orientations and collector types have been investigated. The hourly radiation data were generated by a simple computational simulation procedure. It was found that district solar heating systems with concentrating collectors and passive solar houses showed the largest variations for the given conditions.  相似文献   

20.
This paper reviews different methods that have been proposed to characterize thermal stratification in energy storages from a theoretical point of view. Specifically, this paper focuses on the methods that can be used to determine the ability of a storage to promote and maintain stratification during charging, storing and discharging, and represent this ability with a single numerical value in terms of a stratification efficiency for a given experiment or under given boundary conditions. Existing methods for calculating stratification efficiencies have been applied to hypothetical storage processes of charging, discharging and storing, and compared with the rate of entropy production caused by mixing calculated for the same experiments. The results depict that only one of the applied methods is in qualitative agreement with the rate of entropy production, however, none of the applied methods is in agreement with the rate of entropy production and also able to distinguish between the entropy production caused by mixing and the entropy changes due to heat losses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号