首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A custom in-line surface-induced dissociation (SID) device has been incorporated into a commercial ion mobility quadrupole/time-of-flight mass spectrometer in order to provide an alternative and potentially more informative activation method than the commonly used collision-induced dissociation (CID). Complicated sample mixtures can be fractionated by ion mobility (IM) and then dissociated by CID or SID for further structural analysis. Interpretation of SID spectra for cesium iodide clusters was greatly simplified with IM prior to dissociation because products originating from different precursors and overlapping in m/z but separated in drift time can be examined individually. Multiple conformations of two protein complexes, source-activated transthyretin tetramer and nativelike serum amyloid P decamer, were separated in ion mobility and subjected to CID and SID. CID spectra of the mobility separated conformations are similar. However, drastic differences can be observed for SID spectra of different conformations, implying different structures in the gas phase. This work highlights the potential of utilizing IM-SID to study quaternary structures of protein complexes and provides information that is complementary to our recently reported SID-IM approach.  相似文献   

2.
Surface-induced dissociation (SID) has been implemented in a matrix-assisted laser desorption/ionization time-of-flight mass spectrometer (MALDI TOF MS), allowing production of tandem mass spectrometric information for peptide ions (MALDI TOF SID TOF). The instrument retains the standard operational modes such as the reflectron monitoring of the MALDI-generated intact ions and postsource decay. We show through ion trajectory simulations and experimental results that implementing SID in a commercial MALDI TOF spectrometer is feasible and that the SID products in this instrument fall in an observation time frame that allows the specific detection of fast-fragmentation channels. The instrument design, pulse timing sequence, and high-voltage electronics together with SID spectra of MALDI-generated peptide ions are presented. Standard peptides such as YGGFLR, angiotensin III, fibrinopeptide A, and des-Arg1-bradykinin were dissociated by means of hyperthermal collisions with a gold surface coated with a self-assembled monolayer of 2-(perfluorodecyl)ethanethiol. With the extraction fields and the short observation times used, the spectra obtained show intense low-mass ion signals such as immonium, b2, b3, and y2 ions. TOF data analysis involved matching simulated and experimental flight times and indicates that the observed fragments are produced at approximately 250 ns after the precursor ion collides with the surface. This submicrosecond gas-phase fragmentation time frame is complementary to the observation time frame of existing SID spectrometers, which are on the order of 10 micros for tandem quadrupoles and are larger than a few milliseconds for SID implemented in Fourier transform ion cyclotron resonance spectrometers.  相似文献   

3.
A new instrument configuration based on a Finnigan FTMS-2000 platform has been applied to the study of surface-induced dissociation (SID) in this research. Benzene monomer ions C(6)H(6)(+) and dimer ions (C(6)H(6))(2)(+) were impacted on a fluorinated self-assembled monolayer surface at collision energies ranging from 1 to 70 eV. Benzene cations were chosen for this study because the fragmentation characteristics of the molecular cation are well known and its SID has been thoroughly investigated. SID spectra obtained by FTMS-SID are very similar to those reported in the literature for the same surface but exhibit much higher mass resolution. A comparison study of collision-induced dissociation (CID) and SID of benzene molecular cations was performed utilizing the same ICR cell and ion detection protocol. It is demonstrated that SID provides both much higher energy deposition and a narrower internal energy distribution than CID. The present instrument geometry and experimental protocol demonstrate much higher efficiencies than previous SID studies by FTMS and much higher mass resolution than previous SID studies using other types of mass analyzers.  相似文献   

4.
A new matrix-assisted laser desorption/ionization (MALDI) time-of-flight/time-of-flight (TOF/TOF) high-resolution tandem mass spectrometer is described for sequencing peptides. This instrument combines the advantages of high sensitivity for peptide analysis associated with MALDI and comprehensive fragmentation information provided by high-energy collision-induced dissociation (CID). Unlike the postsource decay technique that is widely used with MALDI-TOF instruments and typically combines as many as 10 separate spectra of different mass regions, this instrument allows complete fragment ion spectra to be obtained in a single acquisition at a fixed reflectron voltage. To achieve optimum resolution and focusing over the whole mass range, it may be desirable to acquire and combine three separate sections. Different combinations of MALDI matrix and collision gas determine the amount of internal energy deposited by the MALDI process and the CID process, which provide control over the extent and nature of the fragment ions observed. Examples of peptide sequencing are presented that identify sequence-dependent features and demonstrate the value of modifying the ionization and collision conditions to optimize the spectral information.  相似文献   

5.
Zhang Z 《Analytical chemistry》2005,77(19):6364-6373
A kinetic model, based on the "mobile proton" model of peptide fragmentation, has been reported previously for quantitative prediction of low-energy collision-induced dissociation (CID) spectra of singly or doubly charged peptides. For peptides with three or more charges, however, the simulation process is complex and time-consuming. This paper describes a simplified model for quantitative prediction of CID spectra of peptide ions with three or more charges. Improvements on other aspects of the model were also made to accommodate large peptides. The performance of the simplified model was evaluated by generating predictions for many known highly charged peptides that were not included in the training data set. It was shown that the model is able to predict peptide CID spectra with reasonable accuracy in fragment ion intensities for highly charged peptide ions up to 5000 u in mass.  相似文献   

6.
Prediction of low-energy collision-induced dissociation spectra of peptides   总被引:1,自引:0,他引:1  
Zhang Z 《Analytical chemistry》2004,76(14):3908-3922
A kinetic model, based on the "mobile proton" model of peptide fragmentation, was developed to quantitatively simulate the low-energy collision-induced dissociation (CID) spectra of peptides dissociated in a quadrupole ion trap mass spectrometer. The model includes most fragmentation pathways described in the literature, plus some additional pathways based on the author's observations. The model was trained by optimizing parameters within the model for predictions of CID spectra of known peptides. A best set of parameters was optimized to obtain best match between the simulated spectra and the experimental spectra in a training data set. The performance of the mathematical model and the associated optimized parameter set used in the CID spectra simulation was evaluated by generating predictions for a large number of known peptides, which were not included in the training data set. It was shown that the model is able to predict peptide CID spectra with reasonable accuracy in fragment ion intensities for both singly and doubly charged peptide parent ions up to 2000 u in mass. The optimized parameter set was evaluated to gain insight into the collision-induced peptide fragmentation process.  相似文献   

7.
The feasibility of obtaining the collision-induced dissociation (CID) spectra of multiply charged peptide ions produced by electrospray ionization in a simple and inexpensive single-quadrupole mass spectrometer is demonstrated. Collisional activation was carried out in the high-pressure region between the capillary exit and the skimmer entrance to the mass analyzer. The CID of multiply charged peptide ions is very efficient, and the observed fragment ion intensities are typically 1-5% of the parent ion intensity prior to CID. About 70 pmol of the peptide is consumed in obtaining each CID spectrum. Spectra obtained by CID of multiply charged ions from bradykinin, angiotensin II, two peptides with features similar to tryptic peptides, and a synthetic analogue of a component of TGF-alpha containing two disulfide bonds are shown. The influence of the primary structure of the peptide on the observed fragmentation pathways is discussed. Although the present single-quadrupole configuration is simple and effective, the inability to choose a particular parent ion for collisional activation makes it less powerful than the triple-quadrupole configuration for mixtures of peptides and peptide samples that yield more than one charge state in the normal mass spectrum. However, it has the potential for inexpensively obtaining sequence information of proteins at high sensitivity by analyzing the pure tryptic peptides obtained by on-line or off-line chromatographic separation of tryptic digests.  相似文献   

8.
A new Fourier transform ion cyclotron resonance mass spectrometer (FTICR MS) has been constructed in our laboratory. The instrument employs surface-induced dissociation (SID) as an activation method for obtaining structural information on biomolecules in the gas phase. Tandem SID mass spectra can be acquired using either a continuous or a pulsed mode of operation. Collision energy of precursor ion is controlled by a dc offset of the ICR cell. This approach eliminates defocusing of the ion beam by the ion-transfer optics as a function of ion kinetic energy and constitutes a significant improvement over our previous experimental setup. Furthermore, it can be easily implemented on any FTICR mass spectrometer. Very high signal-to-noise ratios of 200-500 were obtained in single-scan SID mass spectra of model peptides with acquisition time less than 1.1 s. Reasonable SID signal was detected in single-scan spectra with total acquisition time of only 0.3 s. The high signal-to-noise ratio and the fast acquisition time point on a potential application of SID for high-throughput studies in FTICR MS.  相似文献   

9.
Collision-induced dissociation (CID) is a common ion activation technique used to energize mass-selected peptide ions during tandem mass spectrometry. Characteristic fragment ions form from the cleavage of amide bonds within a peptide undergoing CID, allowing the inference of its amino acid sequence. The statistical characterization of these fragment ions is essential for improving peptide identification algorithms and for understanding the complex reactions taking place during CID. An examination of 1465 ion trap spectra from doubly charged tryptic peptides reveals several trends important to understanding this fragmentation process. While less abundant than y ions, b ions are present in sufficient numbers to aid sequencing algorithms. Fragment ions exhibit a characteristic series-specific relationship between their masses and intensities. Each residue influences fragmentation at adjacent amide bonds, with Pro quantifiably enhancing cleavage at its N-terminal amide bond and His increasing the formation of b ions at its C-terminal amide bond. Fragment ions corresponding to a formal loss of ammonia appear preferentially in peptides containing Gln and Asn. These trends are partially responsible for the complexity of peptide tandem mass spectra.  相似文献   

10.
Intermediate pressure matrix-assisted laser desorption/ionization (MALDI) source was constructed and interfaced with a 6-T Fourier transform ion cyclotron resonance mass spectrometer (FT-ICR MS) specially configured for surface-induced dissociation (SID) studies. First MALDI-SID results in FT-ICR are presented, demonstrating unique advantages of SID over conventional FT-ICR MS ion activation techniques for structural characterization of singly protonated peptide ions. Specifically, we demonstrate that SID on a diamond surface results in a significantly better sequence coverage for singly protonated peptides than SORI-CID. A combination of two effects contributes to the improved sequence coverage: shattering of peptide ions on surfaces opens up a variety of dissociation channels at collision energies above 40 eV, and second, wide internal energy distribution deposited by collision with a stiff diamond surface provides an efficient mixing between the primary reaction channels that are dominant at low internal energies and extensive fragmentation at high internal excitation that results from shattering. Activation of MALDI-generated ions by collisions with surfaces in FT-ICR MS is a new powerful method for characterization and identification of biomolecules  相似文献   

11.
We estimated the reproducibility of tandem mass spectra for the widely used collision-induced dissociation (CID) of peptide ions. Using the Pearson correlation coefficient as a measure of spectral similarity, we found that the within-experiment reproducibility of fragment ion intensities is very high (about 0.85). However, across different experiments and instrument types/setups, the correlation decreases by more than 15% (to about 0.70). We further investigated the accuracy of current predictors of peptide fragmentation spectra and found that they are more accurate than the ad-hoc models generally used by search engines (e.g., SEQUEST) and, surprisingly, approaching the empirical upper limit set by the average across-experiment spectral reproducibility (especially for charge +1 and charge +2 precursor ions). These results provide evidence that, in terms of accuracy of modeling, predicted peptide fragmentation spectra provide a viable alternative to spectral libraries for peptide identification, with a higher coverage of peptides and lower storage requirements. Furthermore, using five data sets of proteome digests by two different proteases, we find that PeptideART (a data-driven machine learning approach) is generally more accurate than MassAnalyzer (an approach based on a kinetic model for peptide fragmentation) in predicting fragmentation spectra but that both models are significantly more accurate than the ad-hoc models.  相似文献   

12.
Immonium ions have been largely overlooked during the rapid expansion of mass spectrometry-based proteomics largely due to the dominance of ion trap instruments in the field. However, immonium ions are visible in hybrid quadrupole-time-of-flight (QTOF) mass spectrometers, which are now widely available. We have created the largest database to date of high-confidence sequence assignments to characterize the appearance of immonium ions in CID spectra using a QTOF instrument under "typical" operating conditions. With these data, we are able to demonstrate excellent correlation between immonium ion peak intensity and the likelihood of the appearance of the expected amino acid in the assigned sequence for phenylalanine, tyrosine, tryptophan, proline, histidine, valine, and the indistinguishable leucine and isoleucine residues. In addition, we have clearly demonstrated a positional effect whereby the proximity of the amino acid generating the immonium ion to the amino terminal of the peptide correlates with the strength of the immonium ion peak. This compositional information provided by the immonium ion peaks could substantially improve algorithms used for spectral assignment in mass spectrometry analysis using QTOF platforms.  相似文献   

13.
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) is a central tool for proteomic analysis, yet the singly protonated tryptic peptide ions produced by MALDI are significantly more difficult to dissociate for tandem mass spectrometry (MS/MS) than the corresponding multiply protonated ions. In order to overcome this limitation, current proteomic approaches using MALDI-MS/MS involve high-energy collision-induced dissociation (CID). Unfortunately, the use of high-energy CID complicates product ion spectra with a significant proportion of irrelevant fragments while also reducing mass accuracy and mass resolution. In order to address the lack of a high-resolution, high mass accuracy MALDI-MS/MS platform for proteomics, Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) and a recently developed MS/MS technique termed CIRCA (for combination of infrared and collisional activation) have been applied to proteomic analysis. Here, CIRCA is shown to be suitable for dissociating singly protonated tryptic peptides, providing greater sequence coverage than either CID or infrared multiphoton dissociation (IRMPD) alone. Furthermore, the CIRCA fragmentation spectra are of sufficient quality to allow protein identification based on the MS/MS spectra alone or in concert with the peptide mass fingerprint (PMF). This is accomplished without compromising mass accuracy or mass resolution. As a result, CIRCA serves to enable MALDI-FTICR-MS/MS for high-performance proteomics experiments.  相似文献   

14.
The fragmentation of natural peptides using dynamic collision-induced dissociation (DCID), a novel fragmentation method for quadrupole ion traps, is demonstrated. Using leucine enkephalin as a diagnostic molecule, the fragmentation efficiencies and energetics of DCID are compared with other methods of collisional activation in ion traps such as conventional on-resonance excitation and high-amplitude short-time excitation (HASTE). A typical fragmentation efficiency of approximately 20% is achieved for DCID, which is significantly lower than conventional CID (maximum near 80%). Tandem mass spectra of two other peptides, substance P and oxidized insulin alpha-chain, demonstrate that product ion spectra for DCID are comparable to conventional or HASTE CID. Because DCID achieves fragmentation during the standard mass acquisition scan, no extra time is necessary for on-resonance excitation or product ion collection, so analysis times are reduced by a minimum of 10-15% depending on the scanning conditions. DCID therefore offers more tandem mass spectra per second than conventional methods of collisional activation, which could be highly advantageous for bottom-up proteomics separations.  相似文献   

15.
Ultraviolet photodissociation (UVPD) of chromophore-modified peptides enhances the capabilities for de novo sequencing in a quadrupole ion trap mass spectrometer. Attachment of UV chromophores allows efficient photoactivation of not only the precursor ions but also any fragments that retain the chromophore functionality. For doubly protonated peptides, UVPD leads to a vast reduction in MS/MS complexity. The array of b and y ions typically seen upon collisionally activated dissociation is reduced to a single series of either y or b ions by UVPD depending on the location of the chromophore (i.e., N- or C-terminus). The sulfonation reagent Alexa Fluor 350 (AF350) provided the best overall results for the singly and doubly charged peptides by UVPD. The nonsulfonated analogue of AF350, 7-amino-4-methylcoumarin-3-acetic acid, also led to simplified spectra for doubly charged, but not singly charged, peptides by UVPD. Dinitrophenyl-peptides also yielded simplified spectra by UVPD albeit with a small amount of internal fragments accompanying the series of diagnostic y ions. The success of this MS/MS simplification process stems from extensive secondary fragmentation of any chromophore-containing fragments upon exposure to subsequent laser pulses. Energy-variable UVPD reveals that the abundances of non-chromophore-containing y fragment ions increase linearly with laser pulse energy, suggesting secondary dissociation of these species is insignificant. The abundances of chromophore-containing a/b fragment ions follow a quadratic trend due to the extensive secondary fragmentation at higher laser energies or multiple pulses.  相似文献   

16.
The unique focusing properties of the curved-field reflectron provide a simple solution to the problem of compensating for the broad range of energies of product ions produced postsource in a time-of-flight mass spectrometer. This has been shown previously for the technique known as postsource decay, but in this report we demonstrate its use for tandem time-of-flight mass spectrometry using a high-performance MALDI time-of-flight instrument modified by the addition of a collision chamber to enable the recording of mass-selected product ions formed by collision-induced dissociation (CID). In particular, the curved-field reflectron enables the use of the full 20-keV kinetic energy provided by the ion source extraction voltage as the collision energy in the laboratory frame and obviates the need to reaccelerate the product ions, using a second "source" or "lift" cell. Results are presented for the collision-induced dissociation of fullerenes over a range of collision gas pressures and precursor ion attenuation. In addition, CID tandem mass spectra are obtained for several peptides.  相似文献   

17.
Photodissociation (PD) and surface-induced dissociation (SID) are compared for structural analysis of several nonvolatile compounds analyzed by laser desorption Fourier transform mass spectrometry (LD/FTMS). SID and PD of a porphyrin and two metalloporphyrins were investigated using a variety of experimental conditions. Optimum structural information is obtained from PD when parent ions are irradiated for relatively long times (10-30 s) using 575-nm radiation and short times (0.5-1 s) using 308- or 388-nm radiation. Shorter irradiation times in the visible region resulted in less efficient production of structurally significant product ions, while longer times in the ultraviolet region produced more nonspecific fragment ions, apparently at the expense of more structurally significant fragment ions. SID conversion efficiencies for the porphyrins are estimated for collision energies from 25 to 360 eV, with maximum conversion efficiency found using 62- and 115-eV collision energies for the two porphyrins studied. Results from a concurrent study on the combined use of PD and SID for MS/MS/MS are discussed in the context of these results. The MS3 ion spectra generated by the two dissociation techniques differ more significantly than MS2 product ion spectra. These data suggest some general guidelines for MSn studies of nonvolatile compounds analyzed by LD/FTMS, employing PD and SID for ion activation.  相似文献   

18.
The structural elucidation of organic compounds in complex biofluids and tissues remains a significant analytical challenge. For mass spectrometry, the manual interpretation of collision-induced dissociation (CID) mass spectra is cumbersome and requires expert knowledge, as the fragmentation mechanisms of ions formed from small molecules are not completely understood. The automated identification of compounds is generally limited to searching in spectral libraries. Here, we present a method for interpreting the CID spectra of the organic compound's protonated ions by computing fragmentation trees that establish not only the molecular formula of the compound and all fragment ions but also the dependencies between fragment ions. This is an important step toward the automated identification of unknowns from the CID spectra of compounds that are not in any database.  相似文献   

19.
Ramos AA  Yang H  Rosen LE  Yao X 《Analytical chemistry》2006,78(18):6391-6397
Parallel fragmentations of peptides in the source region and in the collision cell of tandem mass spectrometers are sequentially combined to develop parallel collision-induced-dissociation mass spectrometry (p2CID MS). Compared to MS/MS spectra, the p2CID mass spectra show increased signal intensities (2-400-fold) and number of sequence ions. This improvement is attributed to the fact that p2CID MS virtually samples all the ions generated by electrospray ionization, including intact and fragment ions of different charge states from a peptide. We implement the method using a quadrupole time-of-flight tandem mass spectrometer. The instrument is operated in TOF-MS mode that allows the ions from source region broadband-passing the first mass analyzer to enter the collision cell. Cone voltage and collision energy are investigated to optimize the outcome of the two parallel CID processes. In the in-source parallel CID, elevated cone voltage produces singly charged intact peptide ions and large fragment ions, as well as decreases the charge-state distribution of peptide ions mainly to double and single charges. The in-collision-cell parallel CID is optimized to dissociate the ions from the source region to produce small and medium fragment ions. The method of p2CID MS is especially useful for sequencing of large peptides with labile amide bonds and peptides with C-terminal arginine. It has unique potential for de novo sequencing of peptides and proteome analysis, especially for affinity-enriched subproteomes.  相似文献   

20.
Proline-rich proteins (PRPs), including collagens, complement 1q, and salivary PRPs, are unusually difficult to sequence by mass spectrometry, due to the high efficiency of cleavage at the amide bond on the N-terminal of proline residues and the consequently low relative abundance of fragment arising from cleavages at other amide bonds. To fully characterize these proteins by mass spectrometry, specialized approaches to fragmentation are needed for the peptides with high proline content. Our work reported herein focused on the analysis of the set of peptides derived by tryptic cleavage of the salivary protein PRP-3. Two methods of fragmentation were compared: Collision-induced dissociation (CID) and electron capture dissociation (ECD). The data obtained demonstrated that ECD spectra of peptides containing more than 30% proline residues are simpler and easier to interpret than are CID spectra of those peptides. Factors that limit the two methods of fragmentation include the complexity of information contained in the CID spectra and the low efficiency of ECD processes. A complementary approach using both decomposition methods provides more complete and interpretable sequence information and yielded >93% sequence coverage for the 11-kDa PRP-3 isolated from human saliva.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号