首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Multilayer plastic foils are important packaging materials that are used to extend the shelf life of food products and drinks. Fourier transform infrared (FT-IR) spectroscopic imaging using attenuated total internal reflection (ATR) can be used for the identification and localization of different layers in multilayer foils. A new type of ATR crystal was used in combination with a linear array detector through which large sample areas (400 x 400 microm(2)) could be imaged with a pixel size of 1.6 microm. The method was tested on laminated plastic packing materials containing 5 to 12 layers. The results of the identification of the different materials using ATR-FT-IR were compared with differential scanning calorimetry (DSC) and the layer thickness of the individual layers measured by ATR-FT-IR was compared with polarized light microscopy (LM) and scanning electron microscopy (SEM). It has been demonstrated that individual layers with a thickness of about 3 microm could be identified in multilayer foils with a total thickness ranging from 100 to 150 microm. The results show a spatial resolution of about 4 microm (measured at wavenumbers ranging from 1000 to 1730 cm(-1)), which is about a factor of two better than can be obtained using transmission FT-IR imaging. An additional advantage of ATR is the ease of sample preparation. A good correspondence was found between visible and FT-IR images. The results of ATR-FT-IR imaging were in agreement with those obtained by LM, SEM, and DSC. ATR-FT-IR is superior to the combination of these techniques because it delivers both spatial and chemical information.  相似文献   

2.
Conventional Fourier transform infrared (FT-IR) spectroscopy and microscopy have been widely used in forensic science. New opportunities exist to obtain chemical images and to enhance the spatial resolution using attenuated total reflection (ATR) FT-IR spectroscopy coupled with a focal-plane array (FPA) detector. In this paper, the sensitivity limits of FT-IR imaging using three different ATR crystals (Ge, ZnSe, and diamond) in three different optical arrangements for the detection of model particles is discussed. Model systems of ibuprofen and paracetamol particles having sizes below 32 mum were studied. The collection of drug particles was achieved with the aid of two different tapes: common adhesive tape and a film of polydimethylsiloxane (PDMS). The surface of the film with collected particles was measured directly via ATR-FT-IR imaging. Since the removal of tape from porous surfaces can be difficult, the application of micro ATR-FT-IR imaging directly to the surface of a newspaper contaminated with particles of model drugs is also discussed. In order to assess the feasibility of the chosen method in a forensic case study, the detection of diacetylmorphine hydrochloride traces in PDMS matrix and the finger surface is investigated. The scenarios considered were that of the detection of evidence collected at a crime scene with the tape lift method and the analysis of the finger of an individual after drug handling. The results show broad implications in the detection of drugs of abuse.  相似文献   

3.
Attenuated total reflection-Fourier transform infrared (ATR-FT-IR) imaging is a very useful tool for capturing chemical images of various materials due to the simple sample preparation and the ability to measure wet samples or samples in an aqueous environment. However, the size of the array detector used for image acquisition is often limited and there is usually a trade off between spatial resolution and the field of view (FOV). The combination of mapping and imaging can be used to acquire images with a larger FOV without sacrificing spatial resolution. Previous attempts have demonstrated this using an infrared microscope and a Germanium hemispherical ATR crystal to achieve images of up to 2.5 mm x 2.5 mm but with varying spatial resolution and depth of penetration across the imaged area. In this paper, we demonstrate a combination of mapping and imaging with a different approach using an external optics housing for large ATR accessories and inverted ATR prisms to achieve ATR-FT-IR images with a large FOV and reasonable spatial resolution. The results have shown that a FOV of 10 mm x 14 mm can be obtained with a spatial resolution of approximately 40-60 microm when using an accessory that gives no magnification. A FOV of 1.3 mm x 1.3 mm can be obtained with spatial resolution of approximately 15-20 microm when using a diamond ATR imaging accessory with 4x magnification. No significant change in image quality such as spatial resolution or depth of penetration has been observed across the whole FOV with this method and the measurement time was approximately 15 minutes for an image consisting of 16 image tiles.  相似文献   

4.
Depth profiling in Fourier transform infrared (FT-IR) spectroscopic imaging has been demonstrated using a single reflection variable angle attenuated total reflection (ATR) accessory. Chemical information about samples can be obtained in three dimensions by acquiring ATR-FT-IR images at different angles of incidence through the ATR crystal. The image quality and field of view achieved at different angles of incidence has been discussed. A polymer film comprising two layers has been used as an example to demonstrate the principle of the measurement. The demonstrated approach is a promising tool to obtain depth profiles of heterogeneous materials. The extent of the measured depths is limited and ranges from approximately 0.3 to 4 microm, but the spatial resolution in the z-direction is not limited by diffraction. The development of this approach opens up the possibility to study the spatial heterogeneity of thin films including biological tissues, such as hair and skin, with high depth resolution.  相似文献   

5.
The cross-section of a human hair has been imaged for the first time using the micro attenuated total reflection (ATR) Fourier transformed infrared (FT-IR) method in combination with a focal plane array (FPA) detector. A rigorous approach was applied to determine the spatial resolution, namely, measuring the distance over which the band absorbance changes from 95 to 5% of the maximum absorbance when passing through a sharp interface. The measured value for IR transmission was approximately 16 microm, while the value obtained using ATR imaging was approximately 5 microm. The enhanced spatial resolution achieved by this method allows the medulla of the hair (approximately 8 microm in diameter) to be imaged clearly without the need for a synchrotron source. The spatial resolution of transmission and ATR imaging is compared, and advantages of ATR imaging are discussed.  相似文献   

6.
Attenuated total reflectance Fourier transform infrared (ATR-FT-IR) spectroscopy is used to identify liquid and solid-phase chemicals. This research examines the feasibility of identifying vapor-phase chemicals using a field-portable ATR-FT-IR spectrometer (TravelIR) combined with solid-phase microextraction (SPME). Two nerve agent simulants, diisopropyl methylphosphonate (DIMP) and di-methyl methylphosphonate (DMMP), and three sorbent polymers were evaluated. Each polymer was deposited as a thin film on the instrument's sampling interface to partition and concentrate the simulants from air samples prepared in Tedlar bags. The lowest vapor concentrations identified were 50 ppb (v/v) (DIMP) and 250 ppb (v/v) (DMMP). The ATR-FT-IR instrument demonstrated a linear response at concentrations of 1 ppm (v/v) and below. Increasing the sample exposure time, the sample air velocity, and the film thickness was demonstrated to increase the amount of analyte extracted from the air sample. This research demonstrates that it is feasible to use a portable ATR-FT-IR spectrometer with SPME sampling to detect and identify vapor-phase chemicals.  相似文献   

7.
This work introduces a new and nondestructive methodology for the collection and chemical identification of latent fingermarks. The main challenges of this work were (a) to find an appropriate medium to lift fingermarks from various surfaces and (b) to develop an analytical approach for the identification of small quantities of sample while avoiding spectroscopic interference from the lifting media. Two different lifting media were evaluated and analyzed by ATR-FT-IR spectroscopic imaging, which affords inherent chemical specificity with rapid acquisition of data. This is the first time that chemical images of latent fingermarks collected with gel lifters from different surfaces have been obtained. Spatially resolved chemical images from different depths within the same sample were obtained using ATR-FT-IR imaging with a variable angle ATR accessory to minimize interference from the substrate. The possibility of obtaining, through the developed methodology, three-dimensional depth profiles of surface contaminants collected with the lifting gel shows great potential for the investigation of samples for forensic interest.  相似文献   

8.
In this study, we report the use of attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FT-IR) for the identification and quantitation of two polymorphs of Aprepitant, a substance P antagonist for chemotherapy-induced emesis. Mixtures of the polymorph pair were prepared by weight and ATR-FT-IR spectra of the powdered samples were obtained over the wavelength range of 700-1500 cm(-1). Significant spectral differences between the two polymorphs at 1140 cm(-1) show that ATR-FT-IR can provide definitive identification of the polymorphs. To investigate the feasibility of ATR-FT-IR for quantitation of polymorphic forms of Aprepitant, a calibration plot was constructed with known mixtures of the two polymorphs by plotting the peak ratio of the second derivative of absorbance spectra against the weight percent of form II in the polymorphic mixture. Using this novel approach, 3 wt % of one crystal form could be detected in mixtures of the two polymorphs. The accuracy of ATR-FT-IR in determining polymorph purity of the drug substance was tested by comparing the results with those obtained by X-ray powder diffractometry (XRPD). Indeed, polymorphic purity results obtained by ATR-FT-IR were found to be in good agreement with the predictions made by XRPD and compared favorably with actual values in the known mixtures. The present study clearly demonstrates the potential of ATR-FT-IR as a quick, easy, and inexpensive alternative to XRPD for the determination of polymorphic identity and purity of solid drug substances. The technique is ideally suited for polymorph analysis, because it is precise, accurate, and requires minimal sample preparation.  相似文献   

9.
Yang P  Meng X  Zhang Z  Jing B  Yuan J  Yang W 《Analytical chemistry》2005,77(4):1068-1074
For the first time, attenuated total reflection (ATR)-Fourier transform infrared (FT-IR) spectroscopy was utilized to measure the thickness (d0) of a nanoscale polymer layer on polymer substrate with significant credibility. First, a mathematical formula, A/A0 = 1 - 2d0/ d(p), was derived based on a self-defining subsection function (where d(p) was defined as depth of penetration of ATR and A and A0 were defined as the absorption band area of the characteristic functional group only contained in bulk substrate with a thin polymer layer attachment and the same group in blank substrate, respectively). On the mathematical model, through changing incidence angles, a series of values of A (A0) and corresponding d(p) were obtained, and when plotting A/A0 versus 2/d(p), d0 was obtained as the slope. With polystyrene (coating)/olypropylene (substrate) as a model system, we obtained the relevant values (d0). Comparing the results with the values of practical coating thickness (calculation and TEM observation), we found that this method was able to characterize well the thickness of a thin polymer layer on a polymer substrate in the range from 10 to 110 nm. Errors in the measurement were given and analyzed. Furthermore, this method was well applied in the thickness measurement of a polyacrylamide graft layer on a polypropylene film surface. The effect of pressure in the ATR technique on the coating thickness measurement was also discussed. In comparison with other methods such as XPS, SEM, TEM, and AFM, this approach based on a universal ATR technique was very convenient and fast. This method is expected to widen the application of the ATR-FT-IR technique and stimulate the further development of many fields such as surface self-assembly and surface functionlization.  相似文献   

10.
The identification and quantification of illicit substances in the field is often desirable. Fourier transform infrared spectroscopy (FT-IR) has both qualitative and quantitative capabilities and field portable instruments are commercially available. Transmission infrared spectra of mixtures containing ephedrine hydrochloride, glucose, and caffeine and attenuated total reflection (ATR) infrared spectra of mixtures composed of methylamphetamine hydrochloride, glucose, and caffeine were used to develop principal component regression (PCR) calibration models. The root mean sum of errors of predictions (RMSEP) of all individual components in a mixture from a single measurement was <6% w/w, which reduced to approximately 3% w/w when triplicates were averaged. Sample mixing and grinding are essential to minimize the effect of heterogeneity, as deviations of up to 20% w/w were observed for single measurements of unground samples. Poor predictions of the components in a mixture occurred when samples were "contaminated" with substances not present in the calibration set, as would be expected. When only a single analyte (drug) was targeted, using a calibration set that contained both contaminated and uncontaminated samples, an RMSEP of approximately 4% w/w was achieved. The results demonstrate that ATR-FT-IR has the potential to quantify methylamphetamine samples, and possibly other licit or illicit substances, in at-seizure and on-site scenarios.  相似文献   

11.
Fourier transform infrared (FT-IR) spectroscopy is a valuable technique for characterization of biological samples, providing a detailed fingerprint of the major chemical constituents. However, water vapor and CO(2) in the beam path often cause interferences in the spectra, which can hamper the data analysis and interpretation of results. In this paper we present a new method for removal of the spectral contributions due to atmospheric water and CO(2) from attenuated total reflection (ATR)-FT-IR spectra. In the IR spectrum, four separate wavenumber regions were defined, each containing an absorption band from either water vapor or CO(2). From two calibration data sets, gas model spectra were estimated in each of the four spectral regions, and these model spectra were applied for correction of gas absorptions in two independent test sets (spectra of aqueous solutions and a yeast biofilm (C. albicans) growing on an ATR crystal, respectively). The amounts of the atmospheric gases as expressed by the model spectra were estimated by regression, using second-derivative transformed spectra, and the estimated gas spectra could subsequently be subtracted from the sample spectra. For spectra of the growing yeast biofilm, the gas correction revealed otherwise hidden variations of relevance for modeling the growth dynamics. As the presented method improved the interpretation of the principle component analysis (PCA) models, it has proven to be a valuable tool for filtering atmospheric variation in ATR-FT-IR spectra.  相似文献   

12.
Malek MA  Kim B  Jung HJ  Song YC  Ro CU 《Analytical chemistry》2011,83(20):7970-7977
Our previous work on the speciation of individual mineral particles of micrometer size by the combined use of attenuated total reflectance FT-IR (ATR-FT-IR) imaging and a quantitative energy-dispersive electron probe X-ray microanalysis technique (EPMA), low-Z particle EPMA, demonstrated that the combined use of these two techniques is a powerful approach for looking at the single-particle mineralogy of externally heterogeneous minerals. In this work, this analytical methodology was applied to characterize six soil samples collected at arid areas in China, in order to identify mineral types present in the samples. The six soil samples were collected from two types of soil, i.e., loess and desert soils, for which overall 665 particles were analyzed on a single particle basis. The six soil samples have different mineralogical characteristics, which were clearly differentiated in this work. As this analytical methodology provides complementary information, the ATR-FT-IR imaging on mineral types, and low-Z particle EPMA on the morphology and elemental concentrations, on the same individual particles, more detailed information can be obtained using this approach than when either low-Z particle EPMA or ATR-FT-IR imaging techniques are used alone, which has a great potential for the characterization of Asian dust and mineral dust particles.  相似文献   

13.
Principal component regression (PCR) was applied to a spectral library of proteins in H2O solution acquired by single-pass attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy. PCR was used to predict the secondary structure content, principally alpha-helical and the beta-sheet content, of proteins within a spectral library. Quantitation of protein secondary structure content was performed as a proof of principle that use of single-pass ATR-FT-IR is an appropriate method for protein secondary structure analysis. The ATR-FT-IR method permits acquisition of the entire spectral range from 700 to 3900 cm(-1) without significant interference from water bands. An "inside model space" bootstrap and a genetic algorithm (GA) were used to improve prediction results. Specifically, the bootstrap was utilized to increase the number of replicates for adequate training and validation of the PCR model. The GA was used to optimize PCR parameters, particularly wavenumber selection. The use of the bootstrap allowed for adequate representation of variability in the amide A, amide B, and C-H stretching regions due to differing levels of sample hydration. Implementation of the bootstrap improved the robustness of the PCR models significantly; however, the use of a GA only slightly improved prediction results. Two spectral libraries are presented where one was better suited for beta-sheet content prediction and the other for alpha-helix content prediction. The GA-optimized PCR method for alpha-helix content prediction utilized 120 wavenumbers within the amide I, II, A, B, and IV and the C-H stretching regions and 18 factors. For beta-sheet content predictions, 580 wavenumbers within the amide I, II, A, and B and the C-H stretching regions and 18 factors were used. The validation results using these two methods yielded an average absolute error of 1.7% for alpha-helix content prediction and an average absolute error of 2.3% for beta-sheet content prediction. After the PCR models were developed and validated, they were used to predict the alpha-helix and beta-sheet content of two unknowns, casein and immunoglobulin G.  相似文献   

14.
This paper demonstrates an approach to obtain chemical images of pharmaceutical tablets using attenuated total reflection infrared (ATR-IR) spectroscopy. FT-IR images with different fields of view and spatial resolution have been obtained using a combination of different ATR accessories. FT-IR imaging with the diamond ATR accessory and micro-ATR imaging technique have been compared. With the diamond ATR imaging accessory, compaction to a tablet can be performed and the chemical image measured in situ. It has been found that the diamond ATR imaging accessory gives information on the overall distribution of different components in a tablet while the micro-ATR imaging technique provides a closer look at the tablet with 4-microm spatial resolution. Low-concentration components down to 0.5% have been detected by the micro-ATR method. Both experimental and commercial systems are studied in this paper.  相似文献   

15.
Gonzalez L  Wess T 《Applied spectroscopy》2008,62(10):1108-1114
Developing a noninvasive method to assess the degraded state of historical parchments is essential to providing the best possible care for these documents. The conformational changes observed when collagen molecules, the primary constituent of parchment, unfold have been analyzed using attenuated total reflection-Fourier transform infrared (ATR-FT-IR) spectroscopy and the nanoscopic structural changes have been analyzed using X-ray diffraction (XRD). The relationship between the results obtained from these techniques was studied using principal component analysis, where correlation was found. The extent of gelatinization of historical parchments has been assessed using ATR-FT-IR and XRD and the frequency shifts observed as collagen degrades into gelatin have been reported. These results indicate that collagen degradation can be measured noninvasively in parchment and demonstrate the utility of ATR-FT-IR spectroscopy as a method to investigate historical documents.  相似文献   

16.
The application of single-pass attenuated total reflection Fourier transform infrared (ATR-FT-IR) microscopy was investigated for secondary structure analysis of 15 representative proteins in H2O solution. This is the first reported application of single-pass ATR-FT-IR for protein analysis; thus, the method was validated using transmission FT-IR and multipass ATR-FT-IR as referee methods. The single-pass ATR-FT-IR technique was advantageous since the single-pass geometry permits rapid secondary structure analysis on small volumes of protein in H2O solution without the use of demountable thin path length sample cells. Moreover, the fact that H2O backgrounds were small allowed the simultaneous observation of the amide I-III, A, and B regions without having to perform H2O subtraction. A comparison of replicate protein spectra indicated that the single-pass ATR-FT-IR method yields more reproducible data than those acquired by transmission FT-IR. The observed trends for the amide I-III and A bands obtained by single-pass ATR-FT-IR agreed with those in the literature for conventional transmission FT-IR.  相似文献   

17.
In this study, attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectroscopy is used to investigate water uptake and phase transitions for atmospherically relevant particles. Changes in the ATR-FT-IR spectra of NaCl, NH(4) NO(3), (NH(4))(2)SO(4), Ca(NO(3))(2), and SiO(2) as a function of relative humidity (RH) are presented and discussed. For these various particles, water can (1) become adsorbed on the particle surface; and/or (2) become absorbed in the particle structure to form a hydrate salt; and/or (3) become absorbed by the particle to form a liquid solution. Spectral features and analyses that distinguish these various processes are discussed. For the salts that do undergo a solid to liquid phase transition (deliquescence), excellent agreement is found between the measurements made here with ATR-FT-IR spectroscopy, a relatively simple, inexpensive, and readily available analytical tool, compared to more expensive, elaborate aerosol flow reactor systems using tandem differential mobility analyzers. In addition, for particles that adsorb water, we show here the utility of coupling ATR-FT-IR measurements with simultaneous quartz crystal microbalance (QCM) measurements. This coupling allows for the quantification of the amount of water associated with the particle as a function of relative humidity (f(RH)) along with the spectroscopic data.  相似文献   

18.
Macroscopic attenuated total reflection (ATR) infrared imaging is applied to study the dissolution of realistically sized hydroxypropyl methylcellulose (HPMC) tablets. The water intake into in situ compacted tablets and pre-compacted tablets was studied as a function of compaction pressure. Rigorous analysis of the imaging datasets show that the speed of water intake into HPMC tablet is approximately 4 microm/min and is hardly affected by the studied range of compaction pressures or the type of ATR crystal used (diamond or ZnSe). This constant speed of water intake implies that leakage ('creeping') of water into the space between the tablet and the ATR crystal does not occur. It is shown that the radius of the HPMC tablet initially expands to twice the original radius due to swelling.  相似文献   

19.
New opportunities exist to obtain chemical images using attenuated total reflection infrared (ATR-IR) spectroscopy. This paper shows the feasibility of obtaining FT-IR images with a spatial resolution of at least 3-4 microm using a Ge ATR objective coupled with an infrared microscope. The improved spatial resolution compared to FT-IR images obtained by the transmission method is due to the high refractive index of the ATR crystal, which gives a high numerical aperture and hence, a higher spatial resolution. FT-IR imaging with a conventional diamond ATR accessory has been investigated. This is the first time that FT-IR imaging is reported using such a versatile accessory based on a diamond ATR crystal. These results showed that a spatial resolution up to 13 microm can be achieved without the use of infrared microscope objectives. One advantage of the diamond element is that it allows pressure to be applied and hence, good contact to be obtained over the whole field of view.  相似文献   

20.
Kondyrev AM  Tshmel AE 《Applied optics》1995,34(22):4989-4992
The air gap between an attenuated-total-reflection (ATR) element (prism) and a sample surface reduces the intensity of each recorded spectrum from that sample and distorts the IR-band contours. Recently, the air-gap problem was solved with a moldable ATR element made of IR-transparent chalcogenide glass. When heated to the softening temperature (60-90 °C) and then cooled to room temperature together with a pressed specimen, such an element provides perfect contact with the surface of a rough sample. Some advantages of this new technique are demonstrated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏