首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
We have developed an atmospheric pressure ionization technique called liquid matrix-assisted laser desorption electrospray ionization (liq-MALDESI) for the generation of multiply charged ions by laser desorption from liquid samples deposited onto a stainless steel sample target biased at a high potential. This variant of our previously reported MALDESI source does not utilize an ESI emitter to postionize neutrals. Conversely, we report desorption and ionization from a macroscopic charged droplet. We demonstrate high mass resolving power single-acquisition FT-ICR-MS analysis of peptides and proteins ranging from 1 to 8.6 kDa at atmospheric pressure. The liquid sample acts as a macroscopic charged droplet similar to those generated by electrospray ionization, whereby laser irradiation desorbs analyte from organic matrix containing charged droplets generating multiply charged ions. We have observed a singly charged radical cation of an electrochemically active species indicating oxidation occurs for analytes and therefore water; the latter would play a key role in the mechanism of ionization. Moreover, we demonstrate an increase in ion abundance and a concurrent decrease in surface tension with an increase in the applied potential.  相似文献   

2.
Tang X  Bruce JE  Hill HH 《Analytical chemistry》2006,78(22):7751-7760
Reduced flow rate electrospray ionization has been proven to provide improved sensitivity, less background noise, and improved limits of detections for ESI-MS analysis. Miniaturizing the ESI source from conventional electrospray to microelectrospray and further down to nanoelectrospray has resulted in higher and higher sensitivity; however, when effects of flow rate were investigated for atmospheric pressure ESI-IMS using a nanospray emitter, a striking opposite result was observed. The general tendency we observed in ESI-IMS was that higher flow rate offered higher ion signal intensity throughout a variety of conditions investigated. Thus, further efforts were undertaken to rationalize these contradictory results. It is well accepted that decreased flow rate increases both ionization efficiency and transmission efficiency, thus improving ion signal in ESI-MS. However, our study revealed that decreased flow rate results in decreased ion signal because ion transfer is constant, no matter how flow rate changes in ESI-IMS. Since ion transfer is constant in atmospheric pressure ESI-IMS, ionization efficiency can be studied independently, which otherwise is not possible in ESI-MS in which both ionization efficiency and transmission efficiency vary as conditions alter. In this article, we present a systematic study of signal intensity and ionization efficiency at various experimental conditions using ESI-IMS and demonstrate the ionization efficiency as a function of flow rate, analyte concentration, and solvent composition.  相似文献   

3.
Cai SS  Syage JA 《Analytical chemistry》2006,78(4):1191-1199
In this work, we compare the quantitative accuracy and sensitivity of analyzing lipids by atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI), and electrospray ionization (ESI) LC/MS. The target analytes include free fatty acids and their esters, monoglyceride, diglyceride, and triglyceride. The results demonstrate the benefits of using LC/APPI-MS for lipid analysis. Analyses were performed on a Waters ZQ LC/MS. Normal-phase solvent systems were used due to low solubility of these compounds in aqueous reversed-phase solvent systems. By comparison, APPI offers lower detection limits, generally highest signal intensities, and the highest S/N ratio. APPI is 2-4 times more sensitive than APCI and much more sensitive than ESI without mobile-phase modifiers. APPI and APCI offer comparable linear range (i.e., 4-5 decades). ESI sensitivity is dramatically enhanced by use of mobile phase modifiers (i.e., ammonium formate or sodium acetate); however, these ESI adduct signals are less stable and either are nonlinear or have dramatically reduced linear ranges. Analysis of fish oils by APPI shows significantly enhanced target analyte intensities in comparison with APCI and ESI.  相似文献   

4.
Laser electrospray mass spectrometry (LEMS) with offline classification is used to discriminate plant tissues at atmospheric pressure using an intense (10(13) W cm(-2)), nonresonant (800 nm) femtosecond laser pulse to vaporize cellular content for subsequent mass analysis. The tissue content of the plant within the 0.05 mm(2) laser interaction region is vaporized into the electrospray plume where the molecules are ionized prior to transfer into the mass spectrometer. The measurements for a flower petal, leaf, and stem of an impatiens plant reveal mass spectral signatures that enable discrimination as performed using a compressive linear classifier. The statistical analysis of the plant tissue samples reveals reproducibility of the data for replicate tissue samples and within a single tissue sample. A similar degree of discrimination was achieved for the green and white regions of aphelandra squarrosa (zebra plant) leaves.  相似文献   

5.
An evaluation of over 75 pesticides by high-performance liquid chromatography/mass spectrometry (HPLC/MS) clearly shows that different classes of pesticides are more sensitive using either atmospheric pressure chemical ionization (APCI) or electrospray ionization (ESI). For example, neutral and basic pesticides (phenylureas, triazines) are more sensitive using APCI (especially positive ion). While cationic and anionic herbicides (bipyridylium ions, sulfonic acids) are more sensitive using ESI (especially negative ion). These data are expressed graphically in a figure called an ionization-continuum diagram, which shows that protonation in the gas phase (proton affinity) and polarity in solution, expressed as proton addition or subtraction (pKa), is useful in selecting APCI or ESI. Furthermore, sodium adduct formation commonly occurs using positive ion ESI but not using positive ion APCI, which reflects the different mechanisms of ionization and strengthens the usefulness of the ionization-continuum diagram. The data also show that the concept of "wrong-way around" ESI (the sensitivity of acidic pesticides in an acidic mobile phase) is a useful modification of simple PKa theory for mobile-phase selection. Finally, this finding is used to enhance the chromatographic separation of oxanilic and sulfonic acid herbicides while maintaining good sensitivity in LC/MS using ESI negative.  相似文献   

6.
Real time analysis of human breath is achieved in an atmospheric pressure ionization mass spectrometer (API-MS) by negatively charging exhaled vapors via contact with an electrospray cloud. The spectrum observed is dominated by a wide range of deprotonated fatty acids, including saturated chains up to C14. Above C14, the background from cutaneous sources becomes dominant. We also tentatively identify a series of unsaturated fatty acids (C7-C10), ketomonocarboxylic acids (C6-C10), and a family of aldehydes. The ionization probability of large fatty acids increases drastically when the humidity changes from 20% to 95%. Accordingly, distinguishing lung vapors (humid) from those in the background (dry) requires special precautions. Estimated fatty acid vapor concentrations in breath based on our measurements ( approximately 100 ppt) are in fair agreement with values expected from blood concentrations in the range for which data are available (C3-C6).  相似文献   

7.
Atmospheric pressure chemical ionization was compared with electrospray ionization and atmospheric pressure photoionization (APPI) as an interface of high-performance liquid chromatography (HPLC)-tandem mass spectrometry (MS/MS) for the determination of cyclosporin A (CsA) in biological fluids in support of in vivo pharmacodynamic studies. These ion sources were investigated in terms of their suitability and sensitivity for the detection of CsA. The effects of the eluent flow rate and composition as well as the nebulizer temperatures on the photoionization efficiency of CsA in the positive ion mode under normal-phase HPLC conditions were explored. The ionization mechanism in the APPI environment with and without the use of the dopant was studied using two test compounds and a few solvent systems employed for normal-phase chromatography. The test compounds were observed to be ionized mainly by proton transfer with the self-protonated solvent molecules produced through photon irradiation. Furthermore, ion suppression due to sample matrix interference in the normal-phase HPLC-APPI-MS/MS system was monitored by the postcolumn infusion technique. The applicability of these proposed HPLC-API-MS/MS approaches for the determination of CsA at low nanogram per milliliter levels in rat plasma was examined. These proposed methods were then compared with respect to specificity, linearity, detection limit, and accuracy.  相似文献   

8.
Atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI), together with tandem mass spectrometry (MSn), are used to study the mechanism of chlorination of amines and to develop a method for qualitative and quantitative determination of organic chloramines. Cyclohexylamine and 1,4-butanediamine (putrescine) are used as model compounds to investigate the mechanisms of the reactions between primary aliphatic amines and hypochlorous acid (aqueous Cl2). The chlorination products are identified and characterized by collision-induced dissociation (CID) and H/D exchange. Chlorination occurs by electrophilic addition of Cl+ and may be followed by HCl elimination, hydrolysis, or, in the case of diamines, amine elimination by intramolecular nucleophilic substitution. The relative rates of chlorination at amine and chloramine nitrogens are a function of pH and depend on the basicity of the amine. A novel method for active chlorine quantification using ESI or APCI mass spectrometry is suggested on the basis of the extent of chlorination of a sacrifical amine standard. This measurement has a limit of detection for N-chlorocyclohexylamine in the range of 0.1-10 microM, a linear dynamic range of 10(2)-10(3), and an accuracy of +/-10%, as determined for wastewater samples.  相似文献   

9.
A rectilinear ion trap (RIT) mass analyzer was incorporated into a mass spectrometer fitted with an electrospray ionization source and an atmospheric pressure interface. The RIT mass spectrometer, which was assembled in two different configurations, was used for the study of biological compounds, for which performance data are given. A variety of techniques, including the use of a balanced rf, elevated background gas pressure, automatic gain control, and resonance ejection waveforms with dynamically adjusted amplitude, were applied to enhance performance. The capabilities of the instrument were characterized using proteins, peptides, and pharmaceutical drugs. Unit resolution and an accuracy of better than m/z 0.2 was achieved for mass-to-charge (m/z) ratios up to 2000 Th at a scan rate of approximately 3000 amu/(charge.s) while reduced scan rates gave greater resolution and peak widths of less than m/z 0.5 over the same range. The mass discrimination in trapping externally generated ions was characterized over the range m/z 190-2000 and an optimized low mass cutoff value of m/z 120-140 was found to give equal trapping efficiencies over the entire range. The radial detection efficiency was measured as a function of m/z ratio and found to rise from 35% at low m/z values to more than 90% for ions of m/z 1800. The way in which the ion trapping capacity depends on the dc trapping potential was investigated by measuring the mass shift due to space charge effects, and it was shown that low trapping potentials minimize space charge effects by increasing the useful volume of the device. The collision-induced dissociation (CID) capabilities of the RIT instrument were evaluated by measuring isolation efficiency as a function of mass resolution as well as measuring peptide CID efficiencies. Overall CID efficiencies of more than 60% were easily reached, while isolation of an ion with unit resolution at m/z 524 was achieved with high rejection (>95%) of the adjacent ions. The overall analytical capabilities of the ESI-RIT instrument were demonstrated with the analysis of a mixture of pharmaceutical compounds using multiple-stage mass spectrometry.  相似文献   

10.
Desorption electrospray ionization (DESI) mass spectrometry is used for the rapid (<5 s), selective, and sensitive detection of trace amounts of the peroxide-based explosives, hexamethylene triperoxide diamine (HMTD), tetracetone tetraperoxide (TrATrP), and triacetone triperoxide (TATP), directly from ambient surfaces without any sample preparation. The analytes are observed as the alkali metal ion complexes. Remarkably, collision-induced dissociation (CID) of the HMTD, TATP, and TrATrP complexes with Na(+), K(+), and Li(+) occurs with retention of the metal, a process triggered by an unusual homolytic cleavage of the peroxide bond, forming a distonic ion. This is followed by elimination of a fragment of 30 mass units, shown to be the expected neutral molecule, formaldehyde, in the case of HMTD, but shown by isotopic labeling experiments to be ethane in the cases of TATP and TrATrP. Density functional theory (DFT) calculations support the suggested fragmentation mechanisms for the complexes. Binding energies of Na+ of 40.2 and 33.1 kcal/mol were calculated for TATP-Na(+) and HMTD-Na(+) complexes, suggesting a strong interaction between the peroxide groups and the sodium ion. Increased selectivity is obtained either by MS/MS or by doping the spray solvent with additives that produce the lithium and potassium complexes of TATP, HMTD, and TrATrP. Addition of dopants into the solvent spray increased the signal intensity by an order of magnitude. When pure alcohol or aqueous hydrogen peroxide was used as the spray solvent, the (HMTD + Na)+ complex was able to bind a molecule of alcohol (methanol or ethanol) or hydrogen peroxide, providing additional characteristic ions to increase the selectivity of analysis. DESI also allowed the rapid detection of peroxide explosives in complex matrixes such as diesel fuel and lubricants using single or multiple cation additives (Na(+), K(+), and Li(+), and NH4(+)) in the spray solvent. Low-nanogram detection limits were achieved for HMTD, TrATrP, and TATP in these complex matrixes. The DESI response was linear over 3 orders of magnitude for HMTD and TATP on paper surfaces (1-5000 ng), and quantification of both peroxide explosives from paper gave precisions (RSD) of less than 3%. The use of pure water and compressed air as the DESI spray solution and nebulizing gas, respectively, showed similar ionization efficiencies to those obtained using methanol/water mixtures and nitrogen gas (the typical choices). An alternative ambient method, desorption atmospheric pressure chemical ionization (DAPCI), was also used to detect trace amounts of HMTD and TATP in air by complexation with gas-phase ammonium ions (NH4(+)) generated by atmospheric pressure ammonia ionization.  相似文献   

11.
The applicability of different ionization techniques, electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and a novel atmospheric pressure photoionization (APPI), were tested for the identification of the phase II metabolites of apomorphine, dobutamine, and entacapone in rat urine and in vitro incubation mixtures (rat hepatocytes and human liver microsomes). ESI proved to be the most suitable ionization method; it enabled detection of 22 conjugates, whereas APCI and APPI showed only 12 and 14 conjugates, respectively. Methyl conjugates were detected with all ionization methods. Glucuronide conjugates were ionized most efficiently with ESI. Only some of the glucuronides detected with ESI were detected with APCI and APPI. Sulfate conjugates were detected only with ESI. MS/MS experiments showed that the site of glucuronidation or sulfation could not be determined, since the primary cleavage was a loss of the conjugate group (glucuronic acid or SO3), and no site-characteristic product ions were formed. However, it may be possible to determine the site of methylation, since methylated products are more stable than glucuronides or sulfates. Furthermore, the loss of CH3 is not necessarily the primary cleavage, and site characteristic products may be formed. Identification and comparison of conjugates formed from the current model drugs were successfully analyzed in different biological specimens of common interest to biomedical research. A fairly good relation was obtained between the data from in vivo and in vitro models of drug metabolism.  相似文献   

12.
13.
Nemes P  Vertes A 《Analytical chemistry》2007,79(21):8098-8106
Mass spectrometric analysis of biomolecules under ambient conditions promises to enable the in vivo investigation of diverse biochemical changes in organisms with high specificity. Here we report on a novel combination of infrared laser ablation with electrospray ionization (LAESI) as an ambient ion source for mass spectrometry. As a result of the interactions between the ablation plume and the spray, LAESI accomplishes electrospray-like ionization. Without any sample preparation or pretreatment, this technique was capable of detecting a variety of molecular classes and size ranges (up to 66 kDa) with a detection limit of 8 and 25 fmol for verapamil and reserpine, respectively, and quantitation capabilities with a four-decade dynamic range. We demonstrated the utility of LAESI in a broad variety of applications ranging from plant biology to clinical analysis. Proteins, lipids, and metabolites were identified, and antihistamine excretion was followed via the direct analysis of bodily fluids (urine, blood, and serum). We also performed in vivo spatial profiling (on leaf, stem, and root) of metabolites in a French marigold (Tagetes patula) seedling.  相似文献   

14.
First examples of highly charged ions in mass spectrometry (MS) produced from the solid state without using solvent during either sample preparation or mass measurement are reported. Matrix material, matrix/analyte homogenization time and frequency, atmospheric pressure (AP) to vacuum inlet temperature, and mass analyzer ion trap conditions are factors that influence the abundance of the highly charged ions created by laserspray ionization (LSI). LSI, like matrix-assisted laser desorption/ionization (MALDI), uses laser ablation of a matrix/analyte mixture from a surface to produce ions. Preparing the matrix/analyte sample without the use of solvent provides the ability to perform total solvent-free analysis (TSA) consisting of solvent-free ionization and solvent-free gas-phase separation using ion mobility spectrometry (IMS) MS. Peptides and small proteins such as non-β-amyloid components of Alzheimer's disease and bovine insulin are examples in which LSI and TSA were combined to produce multiply charged ions, similar to electrospray ionization, but without the use of solvent. Advantages using solvent-free LSI and IMS-MS include simplicity, rapid data acquisition, reduction of sample complexity, and the potential for an enhanced effective dynamic range. This is achieved by more inclusive ionization and improved separation of mixture components as a result of multiple charging.  相似文献   

15.
Good reliability of Caco-2 permeability studies requires competent sampling and analytical methods to ensure the comparability of day-to-day experiments. In this work, two n-in-one LC/MS/MS methods based on two different ionization techniques were developed and validated for a group of reference compounds; eight of them are recommended by the Food and Drug Administration (FDA) for the evaluation of oral drug permeability. The performance of a new ionization technique, atmospheric pressure photoionization (APPI), as an interface for quantitative LC/MS analysis was evaluated in comparison to the electrospray ionization (ESI). Generally, the validation parameters, including sensitivity, accuracy, and repeatability, were comparable for the APPI and ESI methods. The main difference was that the linear quantitative range of APPI was 3-4 orders of magnitude (r(2) >/= 0.998) whereas in ESI it was typically 2-3 orders of magnitude (r(2) >/= 0.990). By the APPI and ESI methods, the simultaneous analysis of nine highly heterogeneous compounds was achieved within 5.5-7 min, which leads to significant savings in time and cost of the analyses. The successful validation data indicate the usefulness of both the methods for the rapid and sensitive (LOD values typically 相似文献   

16.
We report on the development of a quasi-simultaneous highly selective method for NO and NO2 detection at the ultratrace level. Atmospheric pressure laser ionization (APLI), recently introduced by our group, is used to detect both compounds at low parts per trillion by volume (pptv) mixing ratios. APLI is based on resonance-enhanced multiphoton ionization mass spectrometry. Two-color pump-probe experiments employing a single excimer pumped dye laser combination allow for the ultrasensitive measurement of NO and NO2 within a narrow range of maximum pumping efficiency of the laser dye Coumarin 120. NO is detected via excitation of the long-lived A 2sigma+ (nu' = 1) level at 215.36 nm and subsequently ionized with 308-nm radiation provided by the excimer pump laser. NO2 is ionized after double resonant excitation of the A2B1 and 3psigma manifolds in a (1 + 1' + 1(')) process using 431.65 + 308 nm. The selectivity of the NO measurement exceeds 2,000 with respect to NO2 and N2O5. For NO2, a selectivity of >3,000 with respect to N2O5 and organic nitrates is observed. The current APLI detection limit of NO and NO2 is 0.5 and 5 pptv, respectively, with a 20-s integration time.  相似文献   

17.
In this work, we compared APPI and APCI for normal-phase LC/MS chiral analysis of five pharmaceuticals. Performance was compared both by FIA and by on-column analysis using a ChiralPak AD-H column under optimized conditions. By comparison, APPI generated more reproducible signals and was less susceptible to ion suppression than APCI. APPI generated higher peak area and lower baseline noise, and therefore much higher S/N ratios. APPI sensitivity (i.e., S/N ratio) was approximately 2-130 times higher than APCI by FIA and was approximately 2.6-530 times higher than APCI by on-column analysis depending on specific compounds. The better APPI sensitivity as compared to APCI was more dramatic by on-column analysis than by FIA. APCI sensitivity was degraded by ion suppression caused by LC column bleeding components and by elevated APCI baseline noise relative to APPI. On-column APPI LODs (at S/N = 3) were 83, 16, 17, 95, and 7 pg for enantiomer #1, and 104, 23, 19, 122, and 17 pg for enantiomer #2 for benzoin, naringenin, mianserin, mephenesin, and diperodon, respectively, on a Waters ZQ. APPI offers no concern of explosion hazard relative to APCI corona needle discharge or ESI high voltage discharge when flammable solvents (e.g., hexane) are used as mobile phases. Whether APPI dopants are required depends on the IP(s) of mobile-phase solvent(s) and solvent complexes, and photon energies of VUV lamps. Dopant was not necessary for hexane-based mobile phases due to their self-doping effects. Dopants did enhance Kr lamp APPI sensitivity when MeOH was used as the mobile phase. However, dopants became unnecessary for the MeOH mobile phase when the Ar lamp was used.  相似文献   

18.
A novel approach to microbial detection using atmospheric pressure matrix-assisted laser desorption/ionization with an ion trap mass spectrometer to analyze whole cell bacteria is introduced. This new approach was tested with lyophilized spores and cultures of Bacillus globigii (BG) grown on agar media for 4 days or longer. At each stage of growth, it was found that biomarkers, identified as cyclic lipopeptides known as fengycin and surfactin, could be detected by pulsed ultraviolet laser irradiation of intact BG cells (approximately 5 mg) cocrystallized with alpha-cyano-4-hydroxycinnamic acid. Furthermore, definitive amino acid sequence information was obtained by performing tandem mass spectrometry on the precursor ions of the cyclic lipopeptides. The investigation was broadened to include the examination of aerosolized BG spores collected from the atmosphere and directly deposited onto double-sided tape. Subsequent analysis of the recovered spores resulted in the production of mass peaks consistent with fengycin. Other Bacillus species were analyzed for comparison and showed mass spectral peaks also identified as originating from various cyclic lipopeptides. Further studies were conducted using a pulsed infrared laser as the excitation source to analyze BG cells (approximately 5 mg) suspended in a matrix of 0.03 M ammonium citrate and glycerol resulting in the production of ions characteristic of fengycin and surfactin.  相似文献   

19.
A quantitative method was developed for analysis of lysergic acid diethylamide (LSD) in urine using atmospheric pressure matrix-assisted laser desorption/ionization ion trap mass spectrometry (AP MALDI-ITMS). Following solid-phase extraction of LSD from urine samples, extracts were analyzed by AP MALDI-ITMS. The identity of LSD was confirmed by fragmentation of the [M + H](+) ion using tandem mass spectrometry. The quantification of LSD was achieved using stable-isotope-labeled LSD (LSD-d(3)) as the internal standard. The [M + H](+) ion fragmented to produce a dominant fragment ion, which was used for a selected reaction monitoring (SRM) method for quantitative analysis of LSD. SRM was compared with selected ion monitoring and produced a wider linear range and lower limit of quantification. For SRM analysis of samples of LSD spiked in urine, the calibration curve was linear in the range of 1-100 ng/mL with a coefficient of determination, r(2), of 0.9917. This assay was used to determine LSD in urine samples and the AP MALDI-MS results were comparable to the HPLC/ ESI-MS results.  相似文献   

20.
Fung EN  Yeung ES 《Analytical chemistry》1998,70(15):3206-3212
A linear time-of-flight mass spectrometer was used as a detector for flow cytometry. These two techniques were coupled by a laser vaporization/ionization interface. The estimated mass detection limit of the combined system was 20 amol of serotonin standard with one laser pulse. An aqueous buffer at physiological pH was used to ensure compatibility with cells. Rat peritoneal mast cells (RPMCs) were dispensed into the mass spectrometer in a single file confined within a 20-micron-i.d. capillary. By using the mass spectrometer as a detector, no precolumn staining or derivatization is required. Determination of serotonin and histamine in individual cells was demonstrated. With this method, hundreds of cells can be analyzed within a few minutes. The average amounts of histamine and serotonin per RPMC were found to be 0.75 +/- 0.33 and 0.11 +/- 0.06 fmol, respectively. No correlation was found between the amounts of the two amines in each cell.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏