首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Single-shot thermometry with dual-broadband rotational coherent anti-Stokes Raman spectroscopy that employs amplified spontaneous emission from a broadband modeless dye laser has been examined. Evaluation of single-shot spectra of air, N2, and O2 showed an improved temperature precision at room temperature compared with the precision obtained with a conventional dye laser. A comparison was also made between the use of single-mode and multimode Nd:YAG lasers as sources for narrowband radiation, and in all cases the single-mode Nd:YAG laser resulted in higher precision. The experimental results are compared with theoretical predictions.  相似文献   

2.
Seeger T  Leipertz A 《Applied optics》1996,35(15):2665-2671
Broadband vibrational and dual-broadband pure rotational coherent anti-Stokes Raman scattering (CARS) have been compared in a high-temperature oven, in which the accuracy and single-shot precision of gas temperature and relative O(2)- and N(2)-concentration measurements in hot air were probed over a temperature range that is typical for many combustion processes. To ensure a realistic comparison, we used nearly the same experimental setup for both CARS techniques. Besides temperature information, dual-broadband pure rotational CARS offers the possibility of achieving simultaneous single-shot concentration measurements. The comparison shows that this technique also has significant advantages in temperature evaluation over a large temperature range in comparison with vibrational CARS.  相似文献   

3.
Experiments were performed in the temperature range of 294-1143 K in pure CO(2) using high-resolution rotational coherent anti-Stokes Raman spectroscopy (CARS), in the dual-broadband approach. Experimental single-shot spectra were recorded with high spectral resolution using a single-mode Nd:YAG laser and a relay imaging lens system on the exit of a 1 m spectrometer. A theoretical rotational CARS model for CO(2) was developed for evaluation of the experimental spectra. The evaluated mean temperatures of the recorded single-shot dual-broadband rotational coherent anti-Stokes Raman spectroscopy (DB-RCARS) spectra using this model showed good agreement with thermocouple temperatures, and the relative standard deviation of evaluated single-shot temperatures was generally 2-3%. Simultaneous thermometry and relative CO(2)/N(2)-concentration measurements were demonstrated in the product gas of premixed laminar CO/air flames at atmospheric pressure. Although the model proved to be accurate for thermometry up to 1143 K, limitations were observed at flame temperatures where temperatures were overestimated and relative CO(2)/N(2) concentrations were underestimated. Potential sources for these discrepancies are discussed.  相似文献   

4.
van Veen EH  Roekaerts D 《Applied optics》2005,44(32):6995-7004
An optimal system for temperature measurements by coherent anti-Stokes Raman spectroscopy (CARS) in turbulent flames and flows is presented. In addition to a single-mode pump laser and a modeless dye laser, an echelle spectrometer with a cross disperser is used. This system permits simultaneous measurement of the N2 CARS spectrum and the broadband dye laser profile. A procedure is developed to use software to transform this profile into the excitation profile by which the spectrum is referenced. Simultaneous shot-to-shot referencing is compared to sequential averaged referencing for data obtained in flat flames and in room air. At flame temperatures, the resultant 1.5% imprecision is limited by flame fluctuations, indicating that the system may have a single-shot imprecision below 1%. At room temperature, the 3.8% single-shot imprecision is of the same order as the best values reported for dual-broadband pure-rotational CARS. Using the unique shot-to-shot excitation profiles, simultaneous referencing eliminates systematic errors. At 2000 and 300 K, the 95% confidence intervals are estimated to be +/- 20 and +/- 10 K, respectively.  相似文献   

5.
The noise in single-shot coherent anti-Stokes Raman (CARS) spectroscopy that employs a broadband modeless dye laser (MDL) is examined and the results are compared with those of a conventional dye laser. The noise of the dye-laser, the nonresonant CARS, and the resonant N(2) CARS signals are determined. The use of a MDL is shown to result in substantially reduced CARS noise when the CARS signal is generated with a single-mode pump laser, but only a marginal reduction of noise is observed with a multimode pump source The noise measurements are compared with theoretical predictions that are based on models that assume modes of random amplitudes and phases in the multimode laser sources. The combination of a MDL and a single-mode pump laser is shown to increase the precision of single-shot N(2) CARS temperature measurements.  相似文献   

6.
Bood J  Bengtsson PE  Aldén M 《Applied optics》1998,37(36):8392-8396
A common experimental problem with rotational coherent anti-Stokes Raman spectroscopy (CARS) is undesired spectral interference that is due to stray light from the primary laser beams. Also, for the most developed approach, dual-broadband rotational CARS, practical measurements often suffer from stray light interference from the narrow-band laser, inasmuch as the CARS signal is produced inherently in the spectral vicinity of the narrow-band laser beam. An optical filter does not provide a sufficiently sharp transmission profile, thus leading to signal loss and spectral distortion of the rotational CARS signal. An atomic filter consisting of a sodium-seeded flame is presented here as a solution to the problem, and its usefulness was demonstrated in dual-broadband rotational CARS experiments.  相似文献   

7.
Thumann A  Leipertz A 《Applied optics》1998,37(12):2327-2333
A disadvantage of pure rotational coherent anti-Stokes Raman scattering (CARS) compared with vibrational CARS is the limited dynamic range for temperature measurements. Here an optical configuration is described that overcomes this limitation by the use of two different center-frequency dye lasers in a dual-broadband CARS approach. Its performance is demonstrated for simultaneous pure rotational CARS temperature and relative N(2)-O(2)concentration measurements up to 1950 K at ambient pressure.  相似文献   

8.
We employ picosecond dual-broadband pure-rotational coherent anti-Stokes Raman spectroscopy (CARS) in a one-dimensional (1D) imaging configuration. Temperature and O(2):N(2) concentration ratios are measured along a 1D line of up to 12 mm in length. The images consist of up to 330 individual rotational CARS (RCARS) spectra, corresponding to 330 spatially resolved volume elements in the probe volume. Signal levels are sufficient for the collection of single-laser-pulse images at temperatures of up to approximately 1200 K and shot-averaged images at flame temperatures, demonstrated at 2100 K. The precision of picosecond pure-rotational 1D imaging CARS is assessed by acquiring a series of 100 single-laser-pulse images in a heated flow of N(2) from 410 K-1200 K and evaluating a single volume element for temperature in each image. Accuracy is demonstrated by comparing temperatures from the evaluated averaged spectra to thermocouple readings in the heated flow. Deviations from the thermocouple of <30 K in the evaluated temperature were found at up to 1205 K. Accuracy and single-shot precision are compared to those reported for single-point nanosecond dual-broadband pure-RCARS and nanosecond 1D vibrational CARS.  相似文献   

9.
The potential of measuring temperature and multiple species concentrations (N2, O2, CO) by use of combined vibrational coherent anti-Stokes Raman spectroscopy (CARS) and pure rotational CARS has been investigated. This was achieved with only one Nd:YAG laser and one dye laser together with a single spectrograph and CCD camera. From measurements in premixed sooting C2H4-air flames it was possible to evaluate temperatures from both vibrational CARS and rotational CARS spectra, O2 concentration from the rotational CARS spectra, and CO concentration from the vibrational CARS spectra. Quantitative results from premixed sooting C2H4-air flames are presented, and the uncertainties in the results as well as the possibility of extending the combined CARS technique for probing of additional species are discussed.  相似文献   

10.
Rabenstein F  Leipertz A 《Applied optics》1998,37(21):4937-4943
Single-shot vibrational Raman measurements were performed along an 11-mm-long line crossing the reaction zone in a premixed, fuel-rich (phi = 10), laminar methane-air flame by use of a frequency-tripled Nd:YAG laser with a 355-nm emission wavelength. This laser source seems to have advantages relative to KrF excimer lasers as well as to Nd:YAG lasers at 532 nm for hydrocarbon combustion diagnostics. The Raman emissions of all major species (N(2), O(2), CH(4), H(2), CO(2), H(2)O) were detected simultaneously with a spatial resolution of 0.4 mm. By integration over selected spectral intervals, the mole fractions of all species and subsequently the local gas temperatures have been obtained. A comparison of the temperatures that were found with results from filtered Rayleigh experiments showed good agreement, indicating the success of what are to the best of our knowledge the first one-dimensional single-shot Raman measurements in a sooting hydrocarbon flame.  相似文献   

11.
The accuracy and precision of time-resolved simultaneous temperature and O(2)-concentration measurements in binary N(2)-O(2) mixtures by single-pulse dual-broadband pure rotational coherent anti-Stokes Raman scattering (CARS) have been investigated. We present a detailed comparison of the applicability of six evaluation procedures to measurements of air in a temperature range 300-2050 K. Special emphasis is put on the dependence of the results on experimental restrictions and distortions. This comparison includes the least-sum-of-squared-differences fit (LSF) in the frequency space obtained by use of three different kinds of weighting with respect to signal intensity and in Fourier space by use of the complex or the cosine Fourier transformation, both of which permit a great reduction in the number of data points necessary for multidimensional evaluation. Additionally, a cross-correlation technique is tested that, to the best of our knowledge, was not previously applied to pure rotational CARS. We also present the results of measurements directed to the determination of low O(2)-concentration levels that were performed for various binary mixtures (1.0-15.6% O(2)) and for natural air within a temperature range of 300-773 K. A comparison is given for the three evaluation techniques that have proved most promising for the high-temperature investigations, i.e., the constant and the inverse weighted LSF in frequency space and the Fourier analysis technique.  相似文献   

12.
This report describes a mobile Raman lidar system that has been developed for spectral measurements of samples located remotely at ranges of hundreds of meters. The performance of this system has been quantitatively verified in a lidar calibration experiment using a hard target of standardized reflectance. A new record in detection range was achieved for remote Raman systems using 532 nm laser excitation. Specifically, Raman spectra of liquid benzene were measured with an integration time corresponding to a single 532 nm laser pulse at a distance of 217 meters. The single-shot Raman spectra at 217 meters demonstrated high signal-to-noise ratio and good resolution sufficient for the unambiguous identification of the samples of interest. The transmitter consists of a 20 Hz Nd:YAG laser emitting at 532 nm and 1064 nm and a 178 mm telescope through the use of which allows the system to produce a focused beam at the target location. The receiver consists of a large custom telescope (609 mm aperture) and a Czerny-Turner monochromator equipped with two fast photomultiplier tubes.  相似文献   

13.
An investigation of single pulse coherent anti-Stokes Raman spectroscopy (CARS) noise, determined by the analysis of broadband nonresonant spectra, is described. It is shown that the use of a single-mode rather than a multimode pump laser leads to a significant reduction of CARS noise (40%), down to the level exhibited by the Stokes spectral profile itself. This reduction in noise is attributed to the minimization of the effects due to random variations in the laser temporal profiles by using temporally smooth single-mode laser pumps. A measurement of detector shot noise is presented and its effect on CARS noise is described. The advantages of using a single-mode pump laser in CARS spectroscopy are discussed.  相似文献   

14.
Temperature measurements were performed in a shock-tunnel-generated free jet of hydrogen/oxygen reaction products diluted in argon with a nonsimultaneous, two-excitation-line planar laser-induced fluorescence technique with the hydroxyl radical (OH) as a tracer. Single-shot images were obtained with broadband excitation of isolated transitions in the A(2)Σ(+) ? X(2)Π(1, 0) band of OH near 282 nm, with broadband, temporally integrated detection of the resulting nonresonant emission. A measurement of the fluorescence lifetime in the free jet showed no variation with excited rotational level, allowing the rotational temperature to be obtained from the ratio of single-shot images with laser excitation of different rovibronic transitions.  相似文献   

15.
Meyer TR  Roy S  Gord JR 《Applied spectroscopy》2007,61(11):1135-1140
There is growing interest in the use of short-pulse lasers for coherent anti-Stokes Raman scattering (CARS) to minimize non-resonant background (NRB) contributions in a variety of applications. Using time-coincident picosecond (ps) pump and Stokes beams and a time-delayed ps probe beam, we show that a three orders of magnitude reduction in NRB interference can be achieved in rich hydrocarbon-air flames while preserving 60% to 80% of the CARS signal. This represents a significant improvement in signal-to-interference ratio compared with previous measurements in room temperature air and is attributable to reduced rates of collisional dephasing and relaxation at flame temperatures. Measurements within the flame zone of a laminar flat-flame burner are used to investigate the characteristics of time-coincident and probe-delayed broadband ps N(2)-CARS spectra for C(2)H(4)-air equivalence ratios of 0.5 to 1.2. Up to three ro-vibrational bands of N(2) are excited with each laser shot using 135 ps pump and 106 ps Stokes beams, and the CARS signal is generated using a 135 ps probe beam delayed by 165 ps. The enhanced signal-to-interference ratio achieved in the current work is one to two orders of magnitude higher than that previously achieved using polarization-selection techniques without sensitivity to the effects of birefringence caused by density gradients or test cell windows. Moreover, the use of a 135 ps laser source in this study enables frequency domain "broadband" CARS with sufficient resolution to extract ro-vibrational spectral features under various flame conditions. The effect of probe delay and NRB suppression on characteristics of these broadband CARS spectra are investigated, and evidence of preferential collisional dephasing and relaxation of different ro-vibrational transitions is not detected. This is a promising but preliminary result to be investigated further in future work.  相似文献   

16.
Egermann J  Seeger T  Leipertz A 《Applied optics》2004,43(29):5564-5574
We describe the use of linear Raman scattering for the investigation of fuel-rich sooting flames. In comparison, the frequency-tripled and -quadrupled fundamental wavelengths of a Nd:YAG laser have been used as an excitation source for study of the applicability of these laser wavelengths for analysis of sooting flames. The results obtained show that, for the investigation of strongly sooting flames, 266-nm excitation is better than 355-nm excitation. Although the entire fluorescence intensity of polycyclic aromatic hydrocarbons (PAHs) decreases with rising excitation wavelength, there is increased interference with the Raman signals by displacement of the spectral region of the Raman signals toward the fluorescence maximum of the laser-induced fluorescence emissions. Besides the broadband signals of PAHs, narrowband emissions of laser-produced C2 occur in the spectra of sooting flames and affect the Raman signals. These C2 emission bands are completely depolarized and can be separated by polarization-resolved detection. A comparison of the laser-induced fluorescence emissions of an ethylene flame with those of a methane flame shows the same spectral features, but the intensity of the emissions is larger by a factor of 5 for the ethylene fuel. Using 266-nm radiation for Raman signal excitation makes possible measurements in the ethylene flame also.  相似文献   

17.
A broadband dye laser pumped by a frequency-doubled Nd:YAG laser with a full width at half-maximum from 592 to 610?nm was created for the use in a dual-pump broadband coherent anti-Stokes Raman spectroscopy (CARS) system called width increased dual-pump enhanced CARS (WIDECARS). The desired broadband dye laser was generated with a mixture of Pyrromethene dyes as an oscillator gain medium and a spectral selective optic in the oscillator cavity. A mixture of Rhodamine dyes was used in the amplifier dye cell. To create this laser, a study was performed to characterize the spectral behavior of broadband dye lasers created with Rhodamine dyes 590, 610, and 640 and Pyrromethene dyes 597 and 650, as well as mixtures of these dyes.  相似文献   

18.
Zhang J  Feng Z  Li M  Chen J  Xu Q  Lian Y  Li C 《Applied spectroscopy》2007,61(1):38-47
We tried to investigate the possibility of using a low-repetition-rate pulsed Nd:YAG laser as an excitation source in Raman measurements for solid samples. Based on the results from the Raman spectra excited by continuous wave (CW) 532 and 325 nm lasers, we studied the influence of laser energy and irradiation time of 532 and 355 nm pulsed Nd:YAG lasers (10 Hz repetition rate) on the thermal stability of (NH4)6Mo7O(24).4H2O, NH4VO3, and Ce(NO3)(3).6H2O samples, which usually decompose at relatively low temperatures. It is observed that the heating temperature estimated at these samples caused by the irradiation of 532 nm pulsed laser with 22 mJ is no higher than 100 degrees C even for 60 min exposure. The 355 nm pulsed laser with energies below 8.0 mJ hardly causes thermal damage to hydrated (NH4)6Mo7O24 and hydrated Ce(NO3)3 SAMPLES: However, a 355 nm pulsed laser with only 2.2 mJ causes heating temperatures as high as 200 degrees C in the NH4VO3 SAMPLE: These great differences should be attributed to the electronic absorbance of the above three samples at 355 nm. We also found that a 532 nm pulsed laser with even 22 mJ and a 355 nm pulsed laser with even 8.0 mJ do not cause the phase transition of TiO2 and ZrO2, whose phase transformation easily takes place at elevated temperatures, but pulsed lasers could remove some oxygen atoms from these samples. In addition, for L-alanine and DL-beta-phenylalanine biological samples, it is surprisingly found that they are not damaged by the 355 nm pulsed laser even when the laser energy is increased to 8.0 mJ, possibly because they do not absorb the 355 nm laser. Based on these results, it is demonstrated that low-repetition-rate pulsed lasers with appropriate wavelength and energy can be employed as the excitation sources of Raman spectroscopy for characterizing some solid samples, even the thermally unstable samples.  相似文献   

19.
We have performed high-resolution N2 coherent anti-Stokes Raman spectroscopy (CARS) measurements using a modeless dye laser (MDL) as the Stokes beam source to determine the effects of a reduction in mode noise on the accuracy and precision of the method. These results are compared with previous research that employed a conventional broadband dye laser (CBDL) as the Stokes beam source. A new spectral-fitting procedure was developed to avoid starting-point bias in the least-squares fitting results, which possibly had altered the previous measurements. Single-shot measurements of pressure were performed in a static-pressure vessel over the range of 0.1-4.0 atm to examine the pressure sensitivity of the technique. The precision of these measurements is a measure of the baseline noise level of the system, which sets the detection limit for flow-field pressure fluctuations. Centerline measurements of pressure and temperature in an underexpanded jet (Mj = 1.85) were also used to determine the performance of the technique in a compressible flow field. Our study represents the first known application, to our knowledge, of a MDL CARS system in a low-temperature, low-pressure supersonic environment. Improvements in accuracy for mean single-shot measurements and increased precision were found for pressure vessel conditions above 1.0 atm. For subatmospheric pressure vessel conditions (0.1-1.0 atm) and the underexpanded jet measurements, there was a decrease in accuracy and precision compared with the CBDL results. A comparison with the CBDL study is included, along with a discussion of the MDL system behavior.  相似文献   

20.
Bisson SE 《Applied optics》1995,34(18):3406-3412
A krypton fluoride (KrF) excimer-pumped, nitrogen Raman shifter has been studied for use in a wavelength-optimized solar-blind Raman lidar. First Stokes conversion efficiencies (248 ? 263 nm) as high as 12% have been observed in N2:He gas mixtures. Both oscillator-amplifier and self-seeded configurations were investigated. Wavelength-dependent effects were investigated with a Nd:YAG laser operating at 532 and 266 nm. A comparison of KrF- and Nd:YAG-pumped Raman shifting has shown that the beam quality of the excimer laser was a major factor in limiting the maximum first Stokes conversion efficiency.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号