首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Computer-aided design of PV/wind hybrid system   总被引:1,自引:0,他引:1  
B. Ai  H. Yang  H. Shen  X. Liao 《Renewable Energy》2003,28(10):1491-1512
A complete set of match calculation methods for optimum sizing of PV/wind hybrid system is presented. In this method, the more accurate and practical mathematic models for characterizing PV module, wind generator and battery are adopted; combining with hourly measured meteorologic data and load data, the performance of a PV/wind hybrid system is determined on a hourly basis; by fixing the capacity of wind generators, the whole year’s LPSP (loss of power supply probability) values of PV/wind hybrid systems with different capacity of PV array and battery bank are calculated, then the trade-off curve between battery bank and PV array capacity is drawn for the given LPSP value; the optimum configuration which can meet the energy demand with the minimum cost can be found by drawing a tangent to the trade-off curve with the slope representing the relationship between cost of PV module and that of the battery. According to this match calculation method, a set of match calculation programs for optimum sizing of PV/wind hybrid systems have been developed. Applying these match calculation programs to an assumed PV/wind hybrid system to be installed at Waglan island of Hong Kong, the optimum configuration and its hourly, daily, monthly and yearly performances are given.  相似文献   

2.
《Applied Energy》2009,86(2):163-169
Solar energy and wind energy are the two most viable renewable energy resources in the world. Good compensation characters are usually found between solar energy and wind energy. This paper recommend an optimal design model for designing hybrid solar–wind systems employing battery banks for calculating the system optimum configurations and ensuring that the annualized cost of the systems is minimized while satisfying the custom required loss of power supply probability (LPSP). The five decision variables included in the optimization process are the PV module number, PV module slope angle, wind turbine number, wind turbine installation height and battery capacity. The proposed method has been applied to design a hybrid system to supply power for a telecommunication relay station along south-east coast of China. The research and project monitoring results of the hybrid project were reported, good complementary characteristics between the solar and wind energy were found, and the hybrid system turned out to be able to perform very well as expected throughout the year with the battery over-discharge situations seldom occurred.  相似文献   

3.
System power reliability under varying weather conditions and the corresponding system cost are the two main concerns for designing hybrid solar–wind power generation systems. This paper recommends an optimal sizing method to optimize the configurations of a hybrid solar–wind system employing battery banks. Based on a genetic algorithm (GA), which has the ability to attain the global optimum with relative computational simplicity, one optimal sizing method was developed to calculate the optimum system configuration that can achieve the customers required loss of power supply probability (LPSP) with a minimum annualized cost of system (ACS). The decision variables included in the optimization process are the PV module number, wind turbine number, battery number, PV module slope angle and wind turbine installation height. The proposed method has been applied to the analysis of a hybrid system which supplies power for a telecommunication relay station, and good optimization performance has been found. Furthermore, the relationships between system power reliability and system configurations were also given.  相似文献   

4.
Solar PV arrays made of interconnected modules are comparatively less susceptible to shadow problem and power degradation resulting from the aging of solar cells. This paper presents a simulation model for the sizing of stand-alone solar PV systems with interconnected arrays. It considers the electricity generation in the array and its storage in the battery bank serving the fluctuating load demand. The loss of power supply probability (LPSP) is used to connote the risk of not satisfying the load demand. The non-tracking (e.g., fixed and tilted) and single-axis tracking aperture arrays having cross-connected modules of single crystalline silicon solar cells in a (6×6) modular configuration are considered. The simulation results are illustrated with the help of a numerical example wherein the load demand is assumed to follow uniform probabilistic distribution. For a given load, the numbers of solar PV modules and batteries corresponding to zero values of LPSP on diurnal basis during the year round cycle of operation are presented. The results corresponding to the surplus and deficit of energy as a function of LPSP are also presented and discussed to assess the engineering design trade offs in the system components.Furthermore, a simple cost analysis has also been carried out, which indicates that for Delhi the stand-alone solar PV systems with fixed and tilted aperture arrays are better option than those with single-axis tracking aperture (with north–south oriented tracking axis) arrays.  相似文献   

5.
储能电池是分布式发电系统的关键组件。增加储能电池的容量可以提高发电系统的可靠性,但会增加系统的投资和运行费用。基于上海地区全年8 760 h的气象数据,计算了风光互补发电系统在不同储能容量下的负荷缺电率和能量溢出率的变化。对于独立的风光互补发电系统,在满足能量溢出率小于0.3的情况下,如果系统缺电率维持在1%左右时,需要配置3天的储能容量;如果系统缺电率为0,则需要配置5天的储能容量。  相似文献   

6.
风光互补发电系统的优化设计(I) CAD设计方法   总被引:2,自引:0,他引:2  
给出了一整套利用CAD进行风光互补发电系统优化设计的方法。为了精确确定系统每小时的运行状态,采用了更精确地表征组件特性及评估实际获得的风光资源的数学模型。为了寻找出以最小设备投资成本满足用户用电要求的系统配置,首先在风力发电机容量固定不变的前提下,计算了与该容量风力发电机匹配的不同容量的PV方阵和蓄电池所组成的风/光/蓄组合的全年功率供给亏欠率LPSP,根据总的设备投资成本最小化的原则筛选出一组与该容量风力发电机对应的满足用户给定系统供电可靠性即LPSP值的风/光/蓄组合;然后通过改变风力发电机的容量,优选出多个与不同容量风力发电机对应的既能满足用户用电要求同时总的设备购置成本又是最低的风/光/蓄组合,比较它们的成本最终唯一确定出以最小投资成本满足用户用电要求的优化的系统配置。  相似文献   

7.
This paper develops the Hybrid Solar-Wind System Optimization Sizing (HSWSO) model, to optimize the capacity sizes of different components of hybrid solar-wind power generation systems employing a battery bank. The HSWSO model consists of three parts: the model of the hybrid system, the model of Loss of Power Supply Probability (LPSP) and the model of the Levelised Cost of Energy (LCE). The flow chart of the HSWSO model is also illustrated. With the incorporated HSWSO model, the sizing optimization of hybrid solar-wind power generation systems can be achieved technically and economically according to the system reliability requirements. A case study is reported to show the importance of the HSWSO model for sizing the capacities of wind turbines, PV panel and battery banks of a hybrid solar-wind renewable energy system.  相似文献   

8.
People in the Middle East are facing the problem of freshwater shortages. This problem is more intense for a remote region, which has no access to the power grid. The use of seawater desalination technology integrated with the generated energy unit by renewable energy sources could help overcome this problem. In this study, we refer a seawater reverse osmosis desalination (SWROD) plant with a capacity of 1.5 m3/h used on Larak Island, Iran. Moreover, for producing fresh water and meet the load demand of the SWROD plant, three different stand‐alone hybrid renewable energy systems (SAHRES), namely wind turbine (WT)/photovoltaic (PV)/battery bank storage (BBS), PV/BBS, and WT/BBS are modeled and investigated. The optimization problem was coded in MATLAB software. Furthermore, the optimized results were obtained by the division algorithm (DA). The DA has been developed to solve the sizing problem of three SAHRES configurations by considering the object function's constraints. These results show that this improved algorithm has been simpler, more precise, faster, and more flexible than a genetic algorithm (GA) in solving problems. Moreover, the minimum total life cycle cost (TLCC = 243 763$), with minimum loss of power supply probability (LPSP = 0%) and maximum reliability, was related to the WT/PV/BBS configuration. WT/PV/BBS is also the best configuration to use less battery as a backup unit (69 units). The batteries in this configuration have a longer life cycle (maximum average of annual battery charge level) than two other configurations (93.86%). Moreover, the optimized results have shown that utilizing the configuration of WT/PV/BBS could lead to attaining a cost‐effective and green (without environmental pollution) SAHRES, with high reliability for remote areas, with appropriate potential of wind and solar irradiance.  相似文献   

9.
风电和光电各自出力的不稳定性提高了输电服务成本,制约了它们的发展.利用风能和太阳能的互补性可提高发电的可靠性.研究了风光互补后对电网输电服务价格的影响,提出了考虑可再生能源并网的输电服务价格函数表达式,建立了以该函数值最小为目标,以系统发电不足概率(LOLP)和能量缺失率(LPSP)为约束条件的输电服务价格优化模型.采用粒子群算法对目标函数进行求解,对风光互补前后的输电服务价格进行对比,并求出使输电服务价格最低的风光容量配比.通过对实例系统进行计算,验证了该方法的有效性,指出风光互补能有效地降低输电服务价格.  相似文献   

10.
This paper reports the performance of a 4-kW grid-connected residential wind-photovoltaic system (WPS) with battery storage located in Lowell, MA, USA. The system was originally designed to meet a typical New-England (TNE) load demand with a loss of power supply probability (LPSP) of one day in ten years as recommended by the Utility Company. The data used in the calculation was wind speed and irradiance of Login Airport Boston (LAB) obtained from the National Climate Center in North Carolina. The present performance study is based on two-year operation. (May 1996-Apr 1998) of the WPS. Unlike conventional generation, the wind and the sunrays are available at no cost and generate electricity pollution-free. Around noontime the WPS satisfies its load and provides additional energy to the storage or to the grid. On-site energy production is undoubtedly accompanied with minimization of environmental pollution, reduction of losses in power systems transmission and distribution equipment, and supports the utility in demand side management. This paper includes discussion on system reliability, power quality, loss of supply and effects of the randomness of the wind and the solar radiation on system design  相似文献   

11.
风光互补发电系统的优化设计Ⅱ匹配设计实例   总被引:1,自引:0,他引:1  
根据风光互补发电系统优化设计的CAD方法编制了相应的匹配计算程序,并把该程序应用于一假定安装在香港横澜岛上的风光互补发电系统的优化设计。利用香港天文台提供的1989年全年每小时实测的太阳辐射、风速和温度数据以及全年负载用电分布等数据给出了满足两种供电可靠性要求即全年功率供给亏欠率LPSP分别等于0.1和0.01的优化了的系统配置。文章还比较并讨论了这两种优化的系统配置每小时、每日、每月和全年的性能表现。  相似文献   

12.
A techno-economic analysis for autonomous small scale photovoltaic–wind hybrid energy systems is undertaken for optimisation purposes in the present paper. The answer to the question whether a hybrid photovoltaic–wind or a single photovoltaic or wind system is techno-economically better is also sought. Monthly analysis of 8 year long measured hourly weather data shows that solar and wind resources vary greatly from one month to the next. The monthly combinations of these resources lead to basically three types of months: solar-biased month, wind-biased month and even month. This, in turn, leads to energy systems in which the energy contributions from photovoltaic and wind generators vary greatly. The monthly and yearly system performances simulations for different types of months show that the system performances vary greatly for varying battery storage capacities and different fractions of photovoltaic and wind energy. As well as the system performance, the optimisation process of such hybrid systems should further consist of the system cost. Therefore, the system performance results are combined with system cost data. The total system cost and the unit cost of the produced electricity (for a 20 year system lifetime) are analysed with strict reference to the yearly system performance. It is shown that an optimum combination of the hybrid photovoltaic–wind energy system provides higher system performance than either of the single systems for the same system cost for every battery storage capacity analysed in the present study. It is also shown that the magnitude of the battery storage capacity has important bearings on the system performance of single photovoltaic and wind systems. The single photovoltaic system performs better than a single wind system for 2 day storage capacity, while the single wind system performs better for 1.25 day storage capacity for the same system cost.  相似文献   

13.
W.X. Shen 《Renewable Energy》2009,34(1):348-352
Size optimization of solar array and battery in a standalone photovoltaic (SPV) system is investigated. Based on the energy efficiency model, the loss of power supply probability (LPSP) of the SPV system is calculated for different size combinations of solar array and battery. For the desired LPSP at the given load demand, the optimal size combination is obtained at the minimum system cost. One case study is given to show the application of the method in Malaysian weather conditions.  相似文献   

14.
The current research aims to present an inclusive review of latest research works performed with the aim of improving the efficiency of the hybrid renewable energy systems (HRESs) by employing diverse ranges of the optimization techniques, which aid the designers to achieve the minimum expected total cost, while satisfying the power demand and the reliability. For this purpose, a detailed analysis of the different classification drivers considering the design factors such as the optimization goals, utilized optimization methods, grid type as well as the investigated technology has been conducted. Initial results have indicated that among all optimization goals, load demand parameters including loss of power supply probability (LPSP) and loss of load probability (LLP), cost, sizing (configuration), energy production, and environmental emissions are the most frequent design variables which have been cited the most. Another result of this paper indicates that almost 70% of the research projects have been dedicated towards the optimization of the off-grid applications of the HRESs. Furthermore, it has been demonstrated that, integration of the PV, wind and battery is the most frequent configuration. In the next stage of the paper, a review concerning the sizing methods is also carried out to outline the most common techniques which are used to configure the components of the HRESs. In this regard, an analysis covering the optimized indicators such as the cost drivers, energy index parameters, load indicators, battery’s state of charge, PV generator area, design parameters such as the LPSP, and the wind power generation to load ratio, is also performed.  相似文献   

15.
Lead–acid batteries used in hybrid solar–wind power generation systems operate under very specific conditions, and it is often very difficult to predict when the energy will be extracted from or supplied to the battery. Owing to the highly variable working conditions, no battery model has achieved a good compromise between the complexity and precision. This paper presents a simple mathematical approach to simulate the lead–acid battery behaviors in stand alone hybrid solar–wind power generation systems. Several factors that affect the battery behaviors have been taken into account, such as the current rate, the charging efficiency, the self-discharge rate, as well as the battery capacity. Good agreements were found between the predicted results and the field measured data of a hybrid solar–wind project. At last, calculated from 1-year field data with the simulation model, the time-series battery state-of-charge (SOC) has been statistically analyzed considering the monthly and hourly variations as well as the probability distributions. The results have shown the battery working states in the real hybrid solar–wind power generation system.  相似文献   

16.
The PHOEBUS demonstration plant supplied energy to part of the Central Library in Forschungszentrum Jülich, Germany, for 10 years. The technical feasibility of a self-sufficient energy supply system based on photovoltaic, battery and hydrogen storage was demonstrated. The overall efficiency based on the annual energy balance excluding the photovoltaic efficiency varied from 51% to 64%. The battery bank was able to supply energy to the load for three days in the absence of solar radiation. Around 50–52% of the demands were delivered by the battery. In addition, another 20–25% of the demand was supplied by the fuel cell, which indicates that the energy should be stored in a long-term storage system. Thus, the highest level of energetic reliability can be achieved with relatively low battery capacity and hydrogen storage.  相似文献   

17.
Hourly mean wind-speed data for the period 1986–1997 [except the years 1989 (some data is missing) and 1991 (Gulf War)] recorded at the solar radiation and meteorological monitoring station, Dhahran (26°C 32′ N, 50° 13′ E), Saudi Arabia, have been analyzed to investigate the optimum size of battery storage capacity for hybrid (wind+diesel) energy conversion systems at Dhahran. The monthly average wind speeds for Dhahran range from 4.12 to 6.42 m/s. As a case study, the hybrid system considered in the present analysis consists of two 10 kW Wind Energy Conversion Systems (WECS), together with a battery storage system and a diesel back-up. The yearly and monthly average energy generated from the above hybrid system have been presented. More importantly, the study explores the impact of variation of battery storage capacity on hybrid power generation. The results exhibit a trade-off between size of the storage capacity and diesel power to be generated to cope with specific annual load distribution [41,500], and for given energy generation from WECS. The energy to be generated from the back-up diesel generator and the number of operational hours of the diesel system to meet a specific annual electrical energy demand have also been presented. The diesel back-up system is operated at times when the power generated from WECS fails to satisfy the load and when the battery storage is depleted. The present study shows that for economic considerations, for optimum use of battery storage and for optimum operation of diesel system, storage capacity equivalent to one to three days of maximum monthly average daily demand needs to be used. It has been found that the diesel energy to be generated without any storage is considerably high; however, use of one day of battery storage reduces diesel energy generation by about 35%; also the number of hours of operation of the diesel system are reduced by about 52%.  相似文献   

18.
Decarbonization of the power sector is a key step towards greenhouse gas emissions reduction. Due to the intermittent nature of major renewable sources like wind and solar, storage technologies will be critical in the future power grid to accommodate fluctuating generation. The storage systems will need to decouple supply and demand by shifting electrical energy on many different time scales (hourly, daily, and seasonally). Power-to-Gas can contribute on all of these time scales by producing hydrogen via electrolysis during times of excess electrical generation, and generating power with high-efficiency systems like fuel cells when wind and solar are not sufficiently available. Despite lower immediate round-trip efficiency compared to most battery storage systems, the combination of devices used in Power-to-Gas allows independent scaling of power and energy capacities to enable massive and long duration storage. This study develops and applies a model to simulate the power system balance at very high penetration of renewables. Novelty of the study is the assessment of hydrogen as the primary storage means for balancing energy supply and demand on a large scale: the California power system is analyzed to estimate the needs for electrolyzer and fuel cell systems in 100% renewable scenarios driven by large additions of wind and solar capacities. Results show that the transition requires a massive increase in both generation and storage installations, e.g., a combination of 94 GW of solar PV, 40 GW of wind, and 77 GW of electrolysis systems. A mix of generation technologies appears to reduce the total required capacities with respect to wind-dominated or solar-dominated cases. Hydrogen storage capacity needs are also evaluated and possible alternatives are discussed, including a comparison with battery storage systems.  相似文献   

19.
This paper proposes the generation scheduling approach for a microgrid comprised of conventional generators, wind energy generators, solar photovoltaic (PV) systems, battery storage, and electric vehicles. The electrical vehicles (EVs) play two different roles: as load demands during charging, and as storage units to supply energy to remaining load demands in the MG when they are plugged into the microgrid (MG). Wind and solar PV powers are intermittent in nature; hence by including the battery storage and EVs, the MG becomes more stable. Here, the total cost objective is minimized considering the cost of conventional generators, wind generators, solar PV systems and EVs. The proposed optimal scheduling problem is solved using the hybrid differential evolution and harmony search (hybrid DE-HS) algorithm including the wind energy generators and solar PV system along with the battery storage and EVs. Moreover, it requires the least investment.  相似文献   

20.
The present paper has disseminated the design approach, project implementation, and economics of a nano-grid system. The deployment of the system is envisioned to acculturate the renewable technology into Indian society by field-on-laboratory demonstration (FOLD) and “bridge the gaps between research, development, and implementation.” The system consists of a solar photovoltaic (PV) (2.4 kWp), a wind turbine (3.2 kWp), and a battery bank (400 Ah). Initially, a prefeasibility study is conducted using the well-established HOMER (hybrid optimization model for electric renewable) software developed by the National Renewable Energy Laboratory (NREL), USA. The feasibility study indicates that the optimal capacity for the nano-grid system consists of a 2.16 kWp solar PV, a 3 kWp wind turbine, a 1.44 kW inverter, and a 24 kWh battery bank. The total net present cost (TNPC) and cost of energy (COE) of the system are US$20789.85 and US$0.673/kWh, respectively. However, the hybrid system consisting of a 2.4 kWp of solar PV, a 3.2 kWp of wind turbine, a 3 kVA of inverter, and a 400 Ah of battery bank has been installed due to unavailability of system components of desired values and to enhance the reliability of the system. The TNPC and COE of the system installed are found to be US$20073.63 and US$0.635/kWh, respectively and both costs are largely influenced by battery cost. Besides, this paper has illustrated the installation details of each component as well as of the system. Moreover, it has discussed the detailed cost breakup of the system. Furthermore, the performance of the system has been investigated and validated with the simulation results. It is observed that the power generated from the PV system is quite significant and is almost uniform over the year. Contrary to this, a trivial wind velocity prevails over the year apart from the month of April, May, and June, so does the power yield. This research demonstration provides a pathway for future planning of scaled-up hybrid energy systems or microgrid in this region of India or regions of similar topography.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏