首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The growing demand on water resources has increased the interest in wastewater reclamation for multiple end-use applications such as indirect and direct potable reuse. In these applications, the removal of organic micropollutants is of a greater concern than in conventional wastewater treatment. This article presents a collection of data of trace organic micropollutants in an urban wastewater treatment plant (WWTP) in North East Spain using reverse osmosis (RO) membrane treatment. The RO rejection values of the organic molecules studied with a wide range of solute size and hydrophobicity were determined. Several chromatographic methods monitoring different endocrine disrupting chemicals (EDCs), pharmaceuticals and personal care products (PPCPs) were used. Results indicated that secondary effluents from this Spanish WWTP contained most of the studied organic compounds indicating incomplete removal of organics in the conventional treatment of the plant. However, the rejection of most micropollutants was high for all three RO membrane types (low energy, high rejection, fouling resistant) tested. It was observed that some selected micropollutants were less efficiently removed (e.g. the small and polar and the more hydrophobic) and the molecular weight and membrane material influenced removal efficiencies.  相似文献   

2.
Membrane bio-reactor for advanced textile wastewater treatment and reuse.   总被引:1,自引:0,他引:1  
Textile wastewater contains slowly- or non-biodegradable organic substances whose removal or transformation calls for advanced tertiary treatments downstream Activated Sludge Treatment Plants (ASTP). This work is focused on the treatment of textile industry wastewater using Membrane Bio-reactor (MBR) technology. An experimental activity was carried out at the Baciacavallo Wastewater Treatment Plant (WWTP) (Prato, Italy) to verify the efficiency of a pilot-scale MBR for the treatment of municipal wastewater, in which textile industry wastewater predominates. In the Baciacavallo WWTP the biological section is followed by a coagulation-flocculation treatment and ozonation. During the 5 months experimental period, the pilot-scale MBR proved to be very effective for wastewater reclamation. On average, removal efficiency of the pilot plant (93% for COD, 96% for ammonium and 99% for total suspended solids) was higher than the WWTP ones. Color was removed as in the WWTP. Anionic surf actants removal of pilot plant and WWTP were very similar (92.5 and 93.3% respectively), while the non-ionic surfactants removal was higher in the pilot plant (99.2 vs. 97.1). In conclusion the MBR technology demonstrated to be effective for textile wastewater reclamation, leading both to an improvement of pollutants removal and to a draw-plate simplification.  相似文献   

3.
水环境中PPCPs的臭氧氧化和高级氧化技术   总被引:1,自引:0,他引:1  
药物和个人护理用品(PPCPs)是最近十年引起关注的一类新型有机微量污染物,其对人类健康和生态环境安全的影响受到了越来越多的关注.传统的给水处理和污水处理工艺都不能有效去除水中的PPCPs,因此有必要采用臭氧氧化、高级氧化等工艺进行深度处理.臭氧是选择性氧化剂,其与PPCPs的反应受PPCPs的基团电子特性和溶液pH的影响;高级氧化技术产生的羟基自由基·OH氧化能力强,与PPCPs的反应没有选择性,主要包括O_3/H_2O_2、UV/H_2O_2、UV/TiO_2、芬顿和光芬顿氧化等.这些深度处理工艺的采用受一些因素的限制,同种工艺或不同工艺的组合能达到更高的去除效率.  相似文献   

4.
5.
The aim of this study was to verify the efficiency of removal of microorganisms in effluents of a Wastewater Treatment Plant (WWTP) comprising an association of a UASB reactor followed by three submerged aerated biofilters (BAF) and one tertiary filter. The WWTP designed to treat domestic wastewater from a population of 1,000 inhabitants showed high removal efficiency for organic matter and suspended solids. Helminth eggs were also efficiently removed from the tertiary effluent and were found in the sludge from the UASB reactor; however, removal of bacteria in this system was very low. To enhance the efficiency of the system, the effluent from tertiary filters was submitted to UV disinfection in a real scale reactor. Our results showed that UV irradiation was very effective at lowering the concentrations of E. coli, thermotolerant coliforms and coliphages to acceptable levels for agricultural reuse. Salmonella spp. and helminth eggs were seeded into the tertiary effluent before passing through the UV reactor. Salmonella was not found in the final effluent, but helminth eggs were not completely inactivated by UV irradiation and viable eggs were detected after 28 d of incubation.  相似文献   

6.
The ability of several mesocosm-scale and full-scale constructed wetlands (CWs) to remove pharmaceuticals and personal care products (PPCPs) from urban wastewater was assessed. The results of three previous works were considered as a whole to find common patterns in PPCP removal. The experiment took place outdoors under winter and summer conditions. The mesocosm-scale CWs differed in some design parameters, namely the presence of plants, the vegetal species chosen (Typha angustifolia versus Phragmites australis), the flow configuration (surface flow versus subsurface flow), the primary treatment (sedimentation tank versus HUSB), the feeding regime (batch flow versus continuous saturation) and the presence of gravel bed. The full-scale CWs consisted of a combination of various subsystems (ponds, surface flow CWs and subsurface flow CWs). The studied PPCPs were ketoprofen, naproxen, ibuprofen, diclofenac, salicylic acid, carbamazepine, caffeine, methyl dihydrojasmonate, galaxolide and tonalide. The performance of the evaluated treatment systems was compound dependent and varied as a function of the CW-configuration. In addition, PPCP removal efficiencies were lower during winter. The presence of plants favoured naproxen, ibuprofen, diclofenac, salicylic acid, caffeine, methyl dihydrojasmonate, galaxolide and tonalide removal. Significant positive correlations were observed between the removal of most PPCPs and temperature or redox potential. Accordingly, microbiological pathways appear to be the most likely degradation route for the target PPCPs in the CWs studied.  相似文献   

7.
The evolution of Czech standards requires higher efficiency of nutrient removal from municipal wastewaters. At the beginning of the last decade of 20th century, a new activated sludge configuration called R-AN-D-N process has been described, successfully tested and now largely used at several wastewater treatment plants (WWTP) in the Czech republic. The main feature of the R-AN-D-N process is the introduction of a regeneration zone in sludge recycle, which enables to increase sludge age in the system without any substantial increase in WWTP volume. Performances of three Czech large WWTP with R-AN-D-N configuration have been monitored and compared within a period of one and a half years. The results confirmed excellent nutrient removal efficiency for wastewaters with different proportion between sewage and industrial effluents. Two of three monitored WWTP received wastewaters from breweries (Budweiser and Pilsner Urquell). The settleability of activated sludge from all three WWTP was correct, with SVI values usually ranging from 50 to 150 ml/g. Monitoring of sludge composition indicated proliferation of several filamentous bacteria, particularly types 0581, 0092 and M. parvicella. No severe bulking events were observed. Finally, the operational costs expressed in CZK (Czech crown: 1 CZK = [see symbol in text]0.0322) per cubic metre of treated sewage or per capita amounts respectively from 2.24 to 6.52, and from 285 to 342.  相似文献   

8.
This research is legislation driven by the European Water Framework Directive (WFD) and the Dutch Fourth Memorandum on Water Management. The objective of this research is to achieve the removal of total nitrogen and total phosphorus by Dual Media Filtration. The target value during this research for total nitrogen is 2.2 mg/L and for total phosphorus 0.15 mg/L. The results show that for NOx-N concentrations in the WWTP effluent up to 10 mg/L, a stable operation of the process can be reached with removal rates of 80% to 90%. The maximum nitrogen removal rate was 3.5 kg N/(m3.d). Above 10 mg/L a risk of filter bed clogging occurred. When the orthophosphorus concentration in the WWTP effluent exceeds the maximum of 0.3 mg/L, the total phosphorus concentration in the filtrate water will exceed the target value of 0.15 mg P-total/L. Temperature has a large impact in the phosphorus removal; the optimum temperature range is within 13 degrees C-18 degrees C. In conclusion, Dual Media Filtration is capable of producing reusable water with total phosphorus concentrations of <0.15 mg/L, under the condition that the wastewater treatment plant produces WWTP effluent with steady concentrations for orthophosphorus (<0.3 mg PO4-P/L). To reach total nitrogen concentrations in the filtrate water of <2.2 mg/L a NOx-N removal efficiency of nearly 100% is required.  相似文献   

9.
由于设计进水水质、水量与实际相差较大,重庆市万盛污水处理厂投产之后长期处于低负荷运行状态.在该污水处理厂前期运行过程中,SBR工艺脱氮效率低,能耗较高,处理效果不好.针对此情况,进行了3个月的现场试验,通过调整DO、MLSS、回流比、污泥龄等参数,解决了上述问题,调整后的曝气阶段DO为1~2 mg/L、MLSS为3 500~4 000 mg/L,相应的污泥龄约为15 d、硝化液回流比约为30%,在冬季运行时,使系统脱氮率从低于10%提高到50%左右,出水水质稳定达标.  相似文献   

10.
Understanding of the fate of oestrogen and oestrogenic compounds is important in improving the removal efficiency for oestrogens in wastewater treatment plants (WWTPs). In this study an attempt was made to clarify the fate of oestrogen, oestrogen sulphates, and oestrogenic compounds (synthetic oestrogen, nonylphenol and its relatives) by an instrumental analysis, and the fate of oestrogenicity by an in vitro assay. The investigation was conducted in an activated sludge WWTP in winter and summer, focusing on identification of the primary substances that induce oestrogenicity. Wastewater samples were analysed by employing the silica-gel fractionation technique in conjunction with two-step column chromatography. The results revealed that, in winter, the WWTP efficiencies for the removal of nitrogen and oestrogens decreased and the oestrone level increased with the progress of the treatment. Oestrone and oestrogenic substances are likely to circulate between the aeration tank and the final sedimentation tank. In summer, however, these compounds were effectively removed in the WWTP. The results of the column chromatography coupled with the bioassay suggested that E1 and E2 are the predominant contributors to the oestrogenicity in the influent, return sludge and effluent of the WWTP. The measurement by the instrumental analysis supported these findings.  相似文献   

11.
Wastewater treatment plants (WWTPs) represent a significant source for the input of micro pollutants as endocrine disruptors (EDs) or pharmaceutically active compounds (PhACs) into the aquatic environment. Treatment efficiency of WWTPs often is reported, taking into account only inflow and effluent concentrations without further specification of the WWTP investigated. In order to allow comparison and evaluation of the removal efficiency of different layouts and concepts in wastewater treatment, additional information like the sludge retention time (SRT) and sludge load (F/M ratio) are necessary. Presented results from different WWTPs show correlation of removal of EDs and PhACs to the SRT. Compared to WWTPs with high F/M ratio implementation of the nitrification process on WWTPs results in a significant increase of the removal efficiency for EDs and PhACs. This paper describes an approach to determine comparable removal rates for different activated sludge systems based on mass balance and SRT.  相似文献   

12.
Textile industries carry out several fiber treatments using variable quantities of water, from five to forty times the fiber weight, and consequently generate large volumes of wastewater to be disposed of. Membrane Bio-reactors (MBRs) combine membrane technology with biological reactors for the treatment of wastewater: micro or ultrafiltration membranes are used for solid-liquid separation replacing the secondary settling of the traditional activated sludge system. This paper deals with the possibility of realizing a new section of one existing WWTP (activated sludge + clariflocculation + ozonation) for the treatment of treating textile wastewater to be recycled, equipped with an MBR (76 l/s as design capacity) and running in parallel with the existing one. During a 4-month experimental period, a pilot-scale MBR proved to be very effective for wastewater reclamation. On average, removal efficiency of the pilot plant (93% for COD, and over 99% for total suspended solids) was higher than the WWTP ones. Color was removed as in the WWTP. Anionic surfactants removal of pilot plant was lower than that of the WWTP (90.5 and 93.2% respectively), while the BiAS removal was higher in the pilot plant (98.2 vs. 97.1). At the end cost analysis of the proposed upgrade is reported.  相似文献   

13.
New stricter nitrogen effluent standards and increasing influent loads require existing wastewater treatment plans (WWTPs) to extend or optimize. At WWTPs with limited aeration capacity, limited denitrification capacity or shortage of aerobic sludge age, implementation of SHARON to improve nitrogen effluent quality can be a solution. SHARON is a compact, sustainable and cost-effective biological process for treatment of nitrogen-rich rejection waters. At WWTP Rotterdam-Dokhaven and WWTP Utrecht a SHARON has been in operation for several years. For both WWTPs the effect of SHARON on the nitrogen effluent quality has been evaluated. WWTP Rotterdam-Dokhaven has limited aeration capacity. By implementation of SHARON, the ammonia load of the effluent was reduced by 50%. WWTP Utrecht had limited denitrification capacity. The implementation of SHARON improved the effluent nitrate load by 40%. The overall TN removal efficiency increased from 65% to over 75% and strict nitrogen effluents standards (TN = 10 mg N/l) could be reached. Through modelling and supported by full scale practice it has been shown that by implementation of SHARON in combination with enhanced influent pre-treatment, the aerobic sludge age can be extended to maintain total nitrogen removal at lower temperatures.  相似文献   

14.
Optimisation of nitrifying activated sludge plants towards nutrient removal (denitrification and enhanced P-removal) leads to a substantial reduction of operating costs and improves effluent and operating conditions. At WWTP Zürich-Werdh?elzli, initially designed for nitrification only, an anoxic zone of 28% of total activated sludge volume was installed and allowed 60% nitrogen elimination besides several other optimisations. In 2001 the operation of WWTP Zürich-Glatt was stopped and the wastewater was connected to WWTP Werdh?elzli. To improve nitrogen removal, WWTP Werdh?elzli co-financed two research projects; one for separate digester supernatant treatment with the anammox process operating two SBRs in series and the other applying NH4 sensors for aeration control in order to decrease energy consumption and raise effluent quality. The results of both projects and the consequences for WWTP Werdh?elzli are discussed in this paper.  相似文献   

15.
The return flows of reject water from sewage sludge dewatering alter the activated sludge process in a conventional WWTP and increase TN concentration in the final effluent from WWTP. The objective of the investigation carried out was to consider the application of multistage treatment wetland (MTW) for the treatment of reject water from sewage sludge dewatering in a centrifuge (RWC). This paper aims to present the design and performance of each stage of the treatment as well as the efficiency of total MTW. The full scale pilot plant for RWC, consisting of two vertical flow beds (SS VF) working in series, followed by an horizontal flow bed (SS HF), was built in 2008. The applied configuration ensured a very high removal efficiency of principal pollutant (COD - 76.0% and NH4+-N - 93.6%). In the investigated facilities, the SS VF beds ensured an effective removal of nitrogen compounds, especially NH4+-N, whereas the decomposition of hardly degradable Org-N and COD took place in SS HF. This research illustrates that the MTW could be successfully applied for the treatment of RWC.  相似文献   

16.
This paper presents a full-scale experience of sludge minimization by means of short contact time ozonation in a wastewater treatment plant (WWTP) mainly fed on textile wastewater. The WWTP performance over a 3-year operational data series was analysed and compared with a two-year operation with sludge ozonation. Lab-scale respirometric tests were also performed to characterize biomass activity upstream and downstream of the ozone contact reactor. Results suggest that sludge ozonation: (1) is capable of decreasing excess sludge production by 17%; (2) partially decreases both N removal, by lowering the denitrification capacity, and P removal, by reducing biomass synthesis; (3) increases the decay rate from the typical value of 0.62 d(-1) to 1.3 d(-1); (4) decreases the heterotrophic growth yield from the typical value of 0.67 to 0.58 gCOD/gCOD.  相似文献   

17.
A protocol to select nutrient removal technologies that can achieve low nutrient effluents (total nitrogen (TN) < 5 mg/L and total phosphorus (TP) < 0.5 mg/L) was developed for different wastewater treatment plant (WWTP) sizes based on the research conducted during a Water Environment Research Foundation funded project. The adaptable protocol includes technology and cost assessment of feasible (pre-screened) nutrient removal technologies that are being successfully implemented at full scale. The information collected from the full scale nutrient removal plants to develop this protocol includes design, operational, performance, and cost data through a direct survey of plants, and published data. The protocol includes a "technology threshold" approach consisting of Tier I (TN < 5.0 mg/L; TP < 0.5 mg/L) and Tier II (TN < 3.0 mg/L; TP < 0.1 mg/L) effluent nutrient levels for different plant sizes. A very large WWTP (1,250,000 m(3)/day flow) in Chicago, Illinois, USA adapted this protocol for master planning and design of future nutrient removal facilities based on plant and site specific criteria.  相似文献   

18.
In the near future the WWTP Horstermeer will be confronted with more stringent requirements. Important factor in this respect is the European Water Framework Directive 2000/60/EC. Within the WFD approach the focus is more and more on low nitrogen (<2.2 mg N-total/L) and phosphorus concentrations (<0.15 mg P-total/L) in WWTP effluent. Therefore, research has been initiated at the Horstermeer WWTP to investigate the possibilities of simultaneous nutrient removal with filtration techniques. After nitrite accumulation, caused by phosphorus limitation, was measured in the filtrate water of the 1-STEP filter, research has started. The objective of this research is to minimise the risk on the inhibition of denitrification by phosphorus limitation and to decrease the dosage of coagulant. Therefore a new coagulant dosage system is developed. The back-ground of the coagulant dosage system, the results and cost savings are discussed in this article. When the PO4-P/NOx-N ratio in the WWTP effluent becomes below 0.06 mg/mg phosphorus limitation may occur. The results for phosphorus and nitrogen removal are equal or improved compared to the yearly average of 2008. The results show a more stable removal process and a reduction of the coagulant dosage for the coagulant dosage system of 11% when compared to a continuous dosage ratio of MeP 4 mol/mol.  相似文献   

19.
Emerging wastewater treatment processes such as membrane bioreactors (MBRs) have attracted a significant amount of interest internationally due to their ability to produce high quality effluent suitable for water recycling. It is therefore important that their efficiency in removing hazardous trace organic contaminants be assessed. Accordingly, this study investigated the removal of trace organic chemical contaminants through a full-scale, package MBR in New South Wales, Australia. This study was unique in the context of MBR research because it characterised the removal of 48 trace organic chemical contaminants, which included steroidal hormones, xenoestrogens, pesticides, caffeine, pharmaceuticals and personal care products (PPCPs). Results showed that the removal of most trace organic chemical contaminants through the MBR was high (above 90%). However, amitriptyline, carbamazepine, diazepam, diclofenac, fluoxetine, gemfibrozil, omeprazole, sulphamethoxazole and trimethoprim were only partially removed through the MBR with the removal efficiencies of 24-68%. These are potential indicators for assessing MBR performance as these chemicals are usually sensitive to changes in the treatment systems. The trace organic chemical contaminants detected in the MBR permeate were 1 to 6 orders of magnitude lower than guideline values reported in the Australian Guidelines for Water Recycling. The outcomes of this study enhanced our understanding of the levels and removal of trace organic contaminants by MBRs.  相似文献   

20.
为研究北运河河水、药品和个人护理品( pharmaceuticals and personal care products, PPCPs) 的污染特征和生态风险, 测定了北运河通州段旱季和雨季 5 个河水水样和 43 个地下水样中 13 种 PPCPs 的质量浓度, 并采用风险熵( RQ ) 法对水体中 PPCPs 进行了生态风险评价。结果表明: 除 SMM( 磺胺间甲氧嘧啶) 和 CAP( 氯霉素) 外, 其余 11 种 PPCPs 在不同季节、不同位置的河水和地下水中均有检出, 其中: SMZ( 磺胺二甲嘧啶) 质量浓度最高达 1 373.1 ng/ L, 是研究区水体中的特征污染物; 地下水污染物检出率低于河水但其质量浓度略高于河水, 并且污染物质量浓度随离河距离增加而下降; 地下水中大部分污染物质量浓度雨季大于旱季, 并且承压水中污染物质量浓度小于潜水。由风险熵法计算可得, 除 IBU( 布洛芬) 的生态风险为高风险外, 其余污染物在不同时空条件下对研究区生态风险较低。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号