1.
小型太阳能热泵地板供暖系统的优化研究   总被引:1,自引:1,他引:0  
刘立平  阙炎振 《节能技术》2009,27(4):377-379,382
建立了太阳能热泵地板供暖系统的能量分析、可用能分析数学模型,模拟了上海供暖期的气候条件,给出了系统各部件的可用能损失情况。着重从太阳能集热器并联的组数出发对系统进行了优化研究,并给出了系统供暖性能系数和可用能效率,为该系统的设计及应用提供参考。  相似文献   

2.
An analytical and computational model for a solar assisted heat pump heating system with an underground seasonal cylindrical storage tank is developed. The heating system consists of flat plate solar collectors, an underground cylindrical storage tank, a heat pump and a house to be heated during winter season. Analytical solution of transient field problem outside the storage tank is obtained by the application of complex finite Fourier transform and finite integral transform techniques. Three expressions for the heat pump, space heat requirement during the winter season and available solar energy are coupled with the solution of the transient temperature field problem. The analytical solution presented can be utilized to determine the annual variation of water temperature in the cylindrical store, transient earth temperature field surrounding the store and annual periodic performance of the heating system. A computer simulation program is developed to evaluate the annual periodic water and earth temperatures and system performance parameters based on the analytical solution. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

3.
An analytical model is presented and analyzed to predict the long term performance of a solar assisted house heating system with a heat pump and an underground spherical thermal energy storage tank. The system under investigation consists of a house, a heat pump, solar collectors and a storage tank. The present analytical model is based on a proper coupling of the individual energy models for the house, the heat pump, useful solar energy gain, and the transient heat transfer problem for the thermal energy storage tank. The transient heat transfer problem outside the energy storage tank is solved using a similarity transformation and Duhamel’s superposition principle. A computer code based on the present model is used to compute the performance parameters for the system under investigation. Results from the present study indicate that an operational time span of 5–7 years will be necessary before the system under investigation can attain an annually periodic operating condition. Results also indicate a decrease in the annually minimum value of the storage tank temperature with a decrease in the energy storage tank size and/or solar collector area.  相似文献   

4.
This paper focuses on pump flow rate optimization for forced circulation solar water heating systems with pipes. The system consists of: an array of flat plate solar collectors, two storage tanks for the circulation fluid and water, a heat exchanger, two pumps, and connecting pipes. The storage tanks operate in the fully mixed regime to avoid thermal stratification. The pipes are considered as separated components in the system so as to account for their thermal effects. The objective is to determine optimal flow rates in the primary and secondary loops in order to maximize energy transfer to the circulation fluid storage tank, while reaching user defined temperatures in the water storage tank to increase thermal comfort. A model is developed using mainly the first and second laws of thermodynamics. The model is used to maximize the difference between the energy extracted from the solar collector and the combined sum of the energy extracted by the heat exchanger and corresponding energies used by the pumps in the primary and secondary loops. The objective function maximizes the overall system energy gain whilst minimizing the sum of the energy extracted by the heat exchanger and corresponding pump energy in the secondary loop to conserve stored energy and meet the user requirement of water tank temperatures. A case study is shown to illustrate the effects of the model. When compared to other flow control techniques, in particular the most suitable energy efficient control strategy, the results of this study show a 7.82% increase in the amount of energy extracted. The results also show system thermal losses ranging between 5.54% and 7.34% for the different control strategies due to connecting pipe losses.  相似文献   

5.
Abstract

In this paper, a parametric analysis of two solar heating and cooling systems, one using an absorption heat pump and the other one using an adsorption heat pump, was performed. The systems under investigation were designed to satisfy the energy requirements of a residential building for space heating/cooling purposes and domestic hot water production. The system with the absorption heat pump was analyzed upon varying (i) the solar collectors’ area, (ii) the volume of the hot water storage, (iii) the volume of the cold water tank, and (iv) the climatic conditions. The system with the adsorption heat pump was evaluated upon varying (i) the inlet temperature of hot water supplied to the adsorption heat pump, (ii) the volume of the hot water storage, (iii) the volume of the cold water tank, and (iv) the climatic conditions. The analyses were performed using the dynamic simulation software TRNSYS in terms of primary energy consumption, global carbon dioxide equivalent emissions, and operating costs. The performance of the solar heating and cooling systems was compared with those associated with a conventional system from energy, environmental and economic points of views in order to evaluate the potential benefits.  相似文献   

6.
This study examined an integrated solution of the building energy supply system consisting of flat plate solar thermal collectors in combination with a ground-source heat pump and an exhaust air heat pump for the heating and cooling, and production of domestic hot water. The supply energy system was proposed to a 202 m2 single-family demo dwelling (SFD), which is defined by the Norwegian Zero Emission Building standard. The main design parameters were analyzed in order to find the most essential parameters, which could significantly influenced the total energy use. This study found that 85% of the total heating demand of the SFD was covered by renewable energy. The results showed that the solar energy generated by the system could cover 85–92% and 12–70% of the domestic hot water demand in summer and winter respectively. In addition, the solar energy may cover 2.5–100% of the space heating demand. The results showed that the supply air volume, supply air and zone set point temperatures, auxiliary electrical volume, volume of the DHW tank, orientation and tilt angle and the collector area could influenced mostly the total energy use.  相似文献   

7.
《热科学学报(英文版)》2021,30(5):1491-1502
This paper introduces a novel solar-assisted heat pump system with phase change energy storage and describes the methodology used to analyze the performance of the proposed system. A mathematical model was established for the key parts of the system including solar evaporator, condenser, phase change energy storage tank, and compressor. In parallel to the modelling work, an experimental set-up of the proposed solar energy storage heat pump system was developed. The experimental data showed that the designed system is capable of meeting cold day heating demands in rural areas of Yanbian city located in Jilin province of China. In day-time operation, the solar heat pump system stores excess energy in the energy storage tank for heating purposes. A desired indoor temperature was achieved; the average coefficient of performance of solar heat pump was identified as 4.5, and the system showed a stable performance throughout the day. In night-time operation, the energy stored in the storage tank was released through a liquid-solid change of phase in the employed phase-change material. In this way, the provision of continuous heat for ten hours was ensured within the building, and the desired indoor air conditions were achieved.  相似文献   

8.
A prototype low capacity (10 kW) single stage Li–Br absorption heat pump (AHP), suitable for residential and small building applications has been developed as a collaborative result between various European research institutes and industries. The primary heat source for the AHP is supplied from flat plate solar collectors and the hot/chilled water from the unit is delivered to a floor heating/cooling system. In this paper we present the simulation results and an overview of the performance assessment of the complete system. The calculations were performed for two building types (high and low thermal mass), three climatic conditions, with different types of solar collectors and hot water storage tank sizes and different control systems for the operation of the installation. The simulations were performed using the thermal simulation code TRNSYS. The estimated energy savings against a conventional cooling system using a compression type heat pump was found to be in the range of 20–27%.  相似文献   

9.
The use of solar energy for domestic water heating and space heating has proved to be viable. Space cooling is another promising avenue for utilization of solar energy. Solar operated absorption air-conditioning systems, in different situations, have been found to be feasible. Such systems can make use of the expensive collectors which are, in any case, installed for water and space heating.

In this paper the cooling of a prototype house, in Kufra, is reported. Starting with measured radiation and ambient data, calculations are performed on an hourly basis to determine the cooling load, radiation in the collector plane, heat delivered by the collectors and the heat stored in or discharged from the storage tank. Three different types of collectors with varying efficiencies are considered. These collectors are of the evacuated tube, selective coated and black painted types. The study confirms that the water-lithium bromide absorption system can provide summer air conditioning in arid zones of Jamahiriya where there are diffuclties with the supply of electricity and fossil fuels.  相似文献   


10.
基于流态冰的冰源热泵可以利用近冰点淡水或海水相变潜热作为热源,具有采暖能效高、适用性广的特点。为研究新型冰源热泵在采暖期的能效及经济性,选取我国典型供暖区域的5个城市作为研究对象,结合近5年采暖期各城市的气象参数,分别模拟计算空气源热泵、冰源热泵、地源热泵的系统能效。通过计算各热泵机组的初投资及采暖期运行费用,确定了不同类型热泵系统的静态投资回收期。结果表明,本文提出的新型冰源热泵在采暖期的系统能效较高,为2.8 ~ 3.2。相较于空气源热泵和地源热泵,哈尔滨地区冰源热泵系统的初投资及运行费用最低,不存在静态投资回收期。在北京、郑州、武汉、南京地区的静态投资回收期分别为3.0年、5.1年、2.3年、2.6年。基于流态冰的冰源热泵在冬季供暖方面有很好的应用前景。  相似文献   

11.
针对目前刺参养殖的水温调控系统能耗大及适用性差等问题,提出基于冰源热泵的高效清洁供热及结合跨季节蓄冷实现全年冷热管理的技术思路,采用冰源热泵系统和跨季节蓄冷型冰源热泵系统对养殖水体温度进行调控,建立模型定量对比分析系统的运行能效及技术经济性.结果表明:(1)冰源热泵系统供热和供冷时的性能系数分别为3.33和3.39,全...  相似文献   

12.
In this study, the performance of a solar heating system with a heat pump was investigated both experimentally and theoretically. The experimental results were obtained from November to April during the heating season. The experimentally obtained results are used to calculate the heat pump coefficient of performance (COP), seasonal heating performance, the fraction of annual load met by free energy, storage and collector efficiencies and total energy consumption of the systems during the heating season. The average seasonal heating performance values are 4.0 and 3.0 for series and parallel heat pump systems, respectively. A mathematical model was also developed for the analysis of the solar heating system. The model consists of dynamic and heat transfer relations concerning the fundamental components in the system such as solar collector, latent heat thermal energy storage tank, compressor, condenser, evaporator and meteorological data. Some model parameters of the system such as COP, theoretical collector numbers (Nc), collector efficiency, heating capacity, compressor power, and temperatures (T1, T2, T3, TT) in the storage tank were calculated by using the experimental results. It is concluded that the theoretical model agreed well with the experimental results.  相似文献   

13.
This research target was to improve the thermal efficiency of a solar water heating system (SWHS) coupled with a built-in solar water pump. The designed system consists of 1.58-m2 flat plate solar collectors, an overhead tank placed at the top level, the larger water storage tank without a heat exchanger at the lower level, and a one-way valve for water circulation control. The discharge heads of 1 and 2 m were tested. The pump could operate at the collector temperature of about 70–90 °C and vapor gage pressure of 10–18 kPa. It was found that water circulation within the SWHS ranged between 15 and 65 l/d depending upon solar intensity and discharge head. Moreover, the max water temperature in the storage tank is around 59 °C. The max daily pump efficiency is about 0.0017%. The SWHS could have max daily thermal efficiency of about 21%. It is concluded that the thermal efficiency was successfully improved, except for the pump one. The new SWHS with 1 m discharge head or lower is suitable for residential use. It adds less weight to a building roof and saves electrical energy for a circulation pump. It has lower cost compared to a domestic SWHS.  相似文献   

14.
Thermal performance parameters for a solar-assisted heat pump (SAHP) drying system with underground thermal energy storage (TES) tank and heat recovery unit (HRU) are investigated in this study. The SAHP drying system is made up of a drying unit, a heat pump, flat plate solar collectors, an underground TES tank, and HRU. An analytical model is developed to obtain the performance parameters of the drying system by using the solution of heat transfer problem around the TES tank and energy expressions for other components of the drying system. These parameters are coefficient of performances for the heat pump (COP) and system (COPs), specific moisture evaporation rate (SMER), temperature of water in the TES tank, and energy fractions for energy charging and extraction from the system. A MATLAB program has been prepared using the expressions for the drying system. The obtained results for COP, COPs, and SMER are 5.55, 5.28, and 9.25, respectively, by using wheat mass flow rate of 100 kg h−1, Carnot efficiency of 40%, collector area of 100 m2, and TES tank volume of 300 m3 when the system attains periodic operation duration in fifth year onwards for 10 years of operation. Annual energy saving is 21.4% in comparison with the same system without using HRU for the same input data.  相似文献   

15.
构建空气源热泵-相变蓄热水箱供暖系统,通过相变储能技术的合理应用,优化了太阳能、空气热能等非连续能源的供能方式,有效提高了建筑中可再生能源的利用率。相变蓄热系统采用了6 m3的保温水箱作为蓄热容器,选取46#石蜡为主要相变材料,304#不锈钢管为封装材料。建立蓄热系统的三维数学模型,采用有效热熔法对相变材料的焓值进行处理,运用Fluent数值模拟软件,研究相变蓄热系统的蓄放热性能。模拟结果显示,系统的蓄热时间为9.2 h,理想蓄热量为102.4 kW·h,能够单独提供低能耗建筑连续采暖11.1 h。空气源热泵-相变蓄热水箱供暖系统能实现大跨度的间歇供暖,在利用非连续能源供暖领域具有良好的前景。  相似文献   

16.
As the increase in greenhouse emissions, climate changes, and other irreversible repercussions stems from environmentally destructive energies such as fossil fuels, exploiting solar and geothermal energy as unlimited clean sources of energy in the renewable energy technologies can survive the planet earth, which is facing a catastrophe on a global scale. The main purpose of this research is to study Techno analysis of the combined ground source heat pump (GSHP) and photovoltaic thermal collectors (PVTs) with a “phase-change material” (PCM) storage tank to fulfill the energy demands of a residential building. In the first step of this study, in order to model the heat pump behavior in multi-usage operation modes (heating and cooling), a numerical transient simulation of a water-to-water GSHP, which includes a vertical U-type ground source heat exchanger (GSHX) and a variable speed drive (VSD) compressor, was conducted by developing a numerical code in Engineering Equation Solver software. To study the thermodynamic aspect of the hybrid system in terms of exergy and energy, a transient numerical simulation was accomplished using the TRNSYS program. Also, the impact of effective characteristics of ingredients such as areas of PVT panels and the volume of the storage tank of PCMs on the performance of the hybrid system are investigated. On top of that, the two types of the GSHP-PVT-PCMs and GSHP-PV from the energy and exergy points of view are compared. The obtained results demonstrate that the irreversibility of the solar modules of the GSHP-PVT-PCMs is 6.6% lower than that of the GSHP-PV. Furthermore, the calculation of the annual required load of the building for these two kinds of hybrid systems shows that the use of collectors in this combined system has reduced the total load of the building by 6.5%. The use of collectors in the GSHP-PVT-PCM gives rise to a difference in the value of solar factor (SF) of this system by 1.4% more than the one for the hybrid system without thermal collectors.  相似文献   

17.
In this paper, the ability of a micro combined heat and power (mCHP) system to cover the heat and electricity demand of a single-family residence is investigated. A solid oxide fuel cell based mCHP system coupled with a hot water storage tank is analyzed. The energy profiles of single-family households in different European countries are evaluated. The range of Heat-to-Power Ratio for the SOFC-based mCHP System of 0.5–1.5 shows good agreement with the hot water, space heating and electricity demand during the warm seasons across Europe. This suggests that the fuel cell system should be sized according to the summer energy demand. The winter energy demand shows a Heat-to-Power Ratio which cannot be covered by the mCHP unit alone. To ensure that the mCHP system meets both the thermal and electrical energy demand over the entire year, an auxiliary boiler and a hot water storage tank need to be coupled with the mCHP unit. It is further noted that the size of the auxiliary boiler should match the larger winter space heating demand. In contrast, the hot water tank volume should be sized according to the warm season space heating requirement, when space heating is not required but electricity and hot water are still in demand. This maximizes the running time of the fuel cell, and thus the economic and environmental benefit of the system, without wasting produced heat.  相似文献   

18.
This study presents simulated results of solar water heating systems in a small slaughterhouse using two techniques. The first one is a normal solar water heating system using a flat-plate solar collector and the second one uses a solar-boosted heat pump system having a corrugated metal sheet roof as a solar collector. The number of solar collector units is between 1 and 5, and the volume of water in a storage tank is 300–1200 L. The heat pump in this work uses refrigerant mixture R22:R124:R152a of 20%:57%:23% as the working fluid. The weather conditions of Chiang Mai, Thailand, are taken as the input data. In the case of the normal solar water heating system, the shortest payback periods for 300, 600, 900, and 1200 L water are 3.63, 3.12, 2.95, and 2.82 yr, respectively. The suitable number of collectors for 300 L water is 1 unit with 600–900 L water storage; 2 units of collectors is suitable in the case of 1200 L water, and 3 units of collectors gives the shortest payback period. However, in the case of a solar heat pump system, the suitable payback periods for 300, 600, 900, and 1200 L water are 2.74, 1.79, 1.83, and 1.88 yr, respectively. In our case, 1 unit of this collector gives the shortest payback period.  相似文献   

19.
This paper presents the performance results for a sensible heat storage system. The system under study operates as an air source heat pump which stores the compressor heat of rejection as domestic hot water or hot water in a storage tank that can be used as a heat source for providing building heating. Although measurements were made to quantify space cooling, space heating, and domestic water heating, this paper emphasizes the space heating performance of the unit. The heat storage system was tested for different indoor and outdoor conditions to determine parameters such as heating charge rate, compressor power, and coefficient of performance (COP). The thermal storage tank was able to store a full charge of heat. The rate of increase of storage tank temperature increased with outdoor temperature. The heating rate during a charge test, best shown by the normalized rate plots, increased with evaporating temperature due to the increasing mass flow rate and refrigerant density. At higher indoor temperature during the discharge tests, the rate of decrease of storage tank temperature was slower. Also, the discharge heating rate decreased with time since the thermal storage tank temperature decreased as less thermal energy became available for use. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

20.
Mehmet Esen   《Solar Energy》2000,69(1):47
In this study, the cylindrical phase change storage tank linked to a solar powered heat pump system is investigated experimentally and theoretically. A simulation model defining the transient behaviour of the phase change unit was used. In the tank, the phase change material (PCM) is inside cylindrical tubes and the heat transfer fluid (HTF) flows parallel to it. The heat transfer problem of the model (treated as two-dimensional) was solved numerically by an enthalpy-based finite differences method and validated against experimental data. The experiments were performed from November to May in the heating seasons of 1992–1993 and 1993–1994 to measure both the mean temperature of water within the tank and the inlet and outlet water temperature of the tank. The experimentally obtained inlet water temperatures are also taken as inlet water temperature of the simulated model. Thus, theoretical temperature and stored heat energy distribution within the tank have been determined. Solar radiation and space heating loads for the heating seasons mentioned above are also presented.  相似文献   