共查询到12条相似文献,搜索用时 15 毫秒
1.
Hamid MOJIBIAN Marcelo SPECTOR Nina NI Donna ELISEO Jeffrey POLLAK Michael TAL 《Hemodialysis international. International Symposium on Home Hemodialysis》2009,13(3):329-334
In this paper we wish to report our clinical experience with a new heparin-coated dialysis catheter with a symmetric tip. Over a 16-month period, 60 heparin-coated Tal Palindrome™ catheters were placed in 57 patients. Catheter patency, catheter-related complications, and reasons for catheter removal were recorded. The patient's initial cause of end-stage renal disease, underlying diseases, and site of access were recorded as well. Patients were specifically followed for development of heparin-induced thrombocytopenia. Patient ages were 34–91 (average 66). Fifty-four percent of patients had a history of diabetes. Sixty catheters were placed for a total of 5353 catheter-days. The average catheter indwell time was 107 days (range of 2–381 days). Catheter-related infection occurred in 6 patients over the study period, with a rate of 1.12/1000 catheter-days. Bacteremia occurred in 3 patients with a rate of 0.56/1000 catheter-days. Six catheters were removed or exchanged due to malfunction. There was no incidence of heparin-induced thrombocytopenia. Initial clinical experience with the heparin-coated Tal Palindrome™ hemodialysis catheter demonstrated safe, reliable use, and low infection rates. 相似文献
2.
Silva J Antunes J Carvalho T Ponce P 《Hemodialysis international. International Symposium on Home Hemodialysis》2012,16(4):545-552
Prevalent use of tunneled dialysis catheters can reach 30%. Infection remains the most serious catheter‐related problem. Catheter locks are increasingly used for prevention, but are not yet recommended either by the Food and Drug Association or European Medicines Agency, on the basis of increasing bacterial resistance or lock toxicity. The aim was to test safety and effectiveness of citrate. A prospective, interventional study was conducted to assess the safety and efficacy of a 30% citrate lock in preventing catheter‐related bacteremia (CRB). A total of 157 prevalent tunneled catheters were locked with citrate and prospectively followed during a 1‐year period. The primary endpoint was first CRB diagnosed according to two of the diagnostic criteria for Catheter Infection of Centers for Disease Control and Prevention (CDC), namely definite and probable infection. The CDC criterion of possible but not proved infection was not considered. This citrate lock cohort (n = 157) had 10 episodes of CRB. We observed 0.49 CRB episodes/1000 patient‐days and the mean infection‐free catheter day was 130.6 ± 100.9. No clinically relevant adverse events were observed. No proved tunnel or exit site infection was observed and no patients died because of CRB. Catheter obstruction episodes were reported on 69 occasions out of 14 catheters. These results were compared with an historical cohort from a previous study of catheter locking with low‐dose gentamicin and did not show significant difference in efficacy. Citrate lock is effective in preventing CRB. No toxicity was observed. The use of citrate lock may have advantages over antibiotic locks: No reported bacterial resistance, lower industrial cost, and less manipulation. 相似文献
3.
An unusual case of an irretrievable hemodialysis catheter in a patient with end stage renal disease 下载免费PDF全文
Mehrdad Ghahremani‐Ghajar Anna Jin Peyman Borghei Joline L. T. Chen 《Hemodialysis international. International Symposium on Home Hemodialysis》2018,22(1):E1-E5
Hemodialysis catheters are associated with higher risks of complications compared to arteriovenous fistulas and grafts. Some common complications of dialysis catheters include infection, thrombus formation, central venous stenosis, and mechanical dysfunction. Rarely, catheters can become firmly adhered to a vessel wall. Catheter adhesion is a serious complication that can impact the delivery of safe and effective dialysis to affected patients. Adherent catheters commonly present insidiously with no overt diagnostic signs and symptoms or antecedent catheter malfunction. Prognosis is variable, but can be potentially fatal depending on the severity of adhesion, and sequelae of complications. There are no standardized methods of therapy and treatment strategies are anecdotally reported by interventional radiology, vascular, and cardiothoracic surgery. We hereby describe a case of hemodialysis catheter that has become firmly embedded within the superior vena cava wall. We review the available literature on the epidemiology, risk factors, long‐term sequelae, and known management strategies of adherent catheters. The development of preventative measures will be of great importance given serious complications and limited treatment options. Clinical awareness and understanding of this rare condition is imperative to the prevention and management of adherent catheters. 相似文献
4.
Oguz E Ozturk P Erkul S Calkavur T 《Hemodialysis international. International Symposium on Home Hemodialysis》2012,16(2):306-309
The purpose of this study is to evaluate the efficacy and safety of direct right atrial catheter insertion for hemodialysis in patients with multiple venous access failure. We retrospectively evaluated the charts of 27 patients with multiple venous access failure who had intra-atrial dialysis catheter placement between October 2005 and October 2010 in our clinic. Permanent right atrial dialysis catheters were placed through a right anterior mini-thoracotomy under intratracheal general anesthesia in all patients. Demographics of the cases, the patency rates of hemodialysis via atrial catheterization, existence of any catheter thrombosis, and catheter-related infections were documented and used in statistical analysis. Seventeen women (63%) and 10 men (37%) with the mean age of 59.0 ± 7.1 years (47-71) were enrolled in this study. Chronic renal failure was diagnosed for the mean of 78.9 ± 24.3 months (33-130). Five patients (18.5%) died. Ventricular fibrillation and myocardial infarction were the causes of death in the early postoperative period in two patients. Two of the remaining three patients died because of cerebrovascular events, and one patient died because of an unknown cause. Ten patients (37%) had been using anticoagulate agents (warfarin) because of concomitant disorders such as deep vein thrombosis, operated valve disease, and arrhythmias. Catheter thrombosis and malfunction was determined in three cases (11.1%). Intra-atrial hemodialysis catheterization is a safe and effective life-saving measure for the patients with multiple venous failure and without any possibility of peritoneal dialysis or renal transplantation. 相似文献
5.
Sandeep Peddi Rapur Ram Varalakshmi Devi Boreddy Sridhar Avssn Krishna Kishore Chennu Siva Kumar Vishnubotla 《Hemodialysis international. International Symposium on Home Hemodialysis》2014,18(1):192-194
We present an end‐stage renal disease patient on dialysis with fever. The primary source was right internal jugular vein catheter which had metastatic infections in the body probably via an arteriovenous communication in a cavity in left lung. Patient had right psoas muscle abscess and a left kidney abscess. An 18F‐fluorodeoxyglucose‐positron emission spectroscopy scan was done to find out left kidney abscess. A search of literature did not reveal many patients of psoas abscess secondary to infection of hemodialysis access. 相似文献
6.
Oladipo A. Adeniyi Antonios H. Tzamaloukas 《Hemodialysis international. International Symposium on Home Hemodialysis》2003,7(4):304-310
Background: Hemodialysis (HD) access‐related infection is a major cause of morbidity and mortality in HD patients. We tested whether hypoalbuminemia is a risk factor for HD access infection and whether mortality of HD catheter infection is affected by removal of the infected catheter. Methods: We analyzed the records of 87 patients on chronic HD who were hospitalized for HD access‐related infection. We obtained data on age, sex, preinfection serum albumin level, comorbidities, complications, infecting organism, type of infection, mode of management, and mortality. We compared preinfection serum albumin levels in 79 patients with HD access infection with the serum albumin levels of 198 control patients on chronic HD without HD access infection admitted to the hospital during the same time for other reasons. In the HD catheter infection subgroup, we compared mortalities between patients treated with catheter removal plus antibiotics as the primary mode of management and those treated initially with antibiotics alone. Results: Preadmission serum albumin level was lower in the HD access infection group (2.4 ± 0.6 g/dL) than in the control group (3.2 ± 0.6 g/dL, P < 0.0001). Logistic regression identified preadmission serum albumin level as a strong independent predictor of HD access infection. In a logistic regression model, with age, sex, HIV status, diabetes, and type of HD vascular access (excluding arterovenous fistula) as the covariates, the odds ratio of HD access infection was 9.8 (95% confidence interval [CI] 4.9–19.7) for a serum albumin level ≤ 3.0 g/dL (P < 0.0001), 10.4 (95% CI 4.97–21.6) for a serum albumin level ≤ 2.5 g/dL (P < 0.0001), and 28.0 (95% CI 5.8–135.9) for a serum albumin level ≤ 2.0 g/dL (P < 0.0001). Case mortality was 25.0% (4/16) in patients with tunneled HD catheter infection initially treated with antibiotics alone and 2.8% (2/71) in those treated with catheter removal plus antibiotics at the time of presentation (P = 0.0096). Conclusion: Hypoalbuminemia is associated with increased risk of HD access infection. Treatment of HD access infection with antibiotics alone is associated with increased risk of death. 相似文献
7.
DoSik Hwang Jeong‐Whan Lee Gengsheng L. Zeng 《International journal of imaging systems and technology》2011,21(3):247-252
Described herein are the advantages of using sub‐sinograms for single photon emission computed tomography image reconstruction. A sub‐sinogram is a sinogram acquired with an entire data acquisition protocol, but in a fraction of the total acquisition time. A total‐sinogram is the summation of all sub‐sinograms. Images can be reconstructed from the total‐sinogram or from sub‐sinograms and then be summed to produce the final image. For a linear reconstruction method such as the filtered backprojection algorithm, there is no advantage of using sub‐sinograms. However, for nonlinear methods such as the maximum likelihood (ML) expectation maximization algorithm, the use of sub‐sinograms can produce better results. The ML estimator is a random variable, and one ML reconstruction is one realization of the random variable. The ML solution is better obtained via the mean value of the random variable of the ML estimator. Sub‐sinograms can provide many realizations of the ML estimator. We show that the use of sub‐sinograms can produce better estimations for the ML solution than can the total‐sinogram and can also reduce the statistical noise within iteratively reconstructed images. © 2011 Wiley Periodicals, Inc. Int J Imaging Syst Technol, 21, 247–252, 2011; 相似文献
8.
Ali Mirza Onder A. A. Billings Jayanthi Chandar Linda Nield Denise Francoeur Nancy Simon Carolyn Abitbol Gaston Zilleruelo 《Hemodialysis international. International Symposium on Home Hemodialysis》2013,17(1):75-85
There are current concerns that antibiotic lock solutions (ABL) can induce antimicrobial resistance in long‐term hemodialysis patients. Retrospective chart review of 157 children on hemodialysis between January 1997 and June 2006 was performed. In ERA I, only systemic antibiotics were used. In ERA II, ABL were added to systemic antibiotics when needed. In ERA III, ABL were used for treatment of all cases of catheter‐related bacteremia (CRB) and for CRB prophylaxis in high‐risk patients. The study includes 111,325 catheter days. The CRB incidence was 3.9 CRB/1000 catheter days. There was significant decrease for the total systemic antibiotic exposure (P = 0.0484) and the percentage of catheters lost to malfunction (P = 0.001) in ERA III. Protocol ABL exposure was associated with a trend to increased tobramycin‐gentamicin resistance for gram‐positive CRBs (P = 0.2586) but with improved tobramycin‐gentamicin resistance for gram‐negative (P = 0.0949) and polymicrobial CRBs (P = 0.1776) and improved vancomycin resistance for gram‐positive CRBs (P = 0.0985). This retrospective analysis does not support the premise that ABL use will promote antimicrobial resistance in the hemodialysis population. The decreased exposure to systemic antibiotics by vigorous ABL use may even improve the antimicrobial resistance patterns in this population in the long term. 相似文献
9.
van Laecke S Dhondt A de Sutter J Vanholder R 《Hemodialysis international. International Symposium on Home Hemodialysis》2005,9(3):236-240
The creation of an accurate functioning arteriovenous fistula has been a long-lasting problem in the hemodialysis setting. In spite of recent guidelines and largely because of the old age of the current dialysis population and a high incidence of diabetes mellitus, atherosclerosis, and related vascular problems, it is not always possible to create an adequate fistula. In that case, long-term tunneled indwelling central vein catheters are a frequently used alternative. Of the many possible complications related to venous access in hemodialysis patients, catheter dysfunction is the most prevalent. We report a 23-year-old female hemodialysis patient in whom such malfunctioning was followed by echocardiography that revealed a large right atrial thrombus (RAT) in close contact to the tip of a long-term indwelling catheter in the presence of a patent foramen ovale. Although RAT is a rare complication in hemodialysis patients, it has very specific therapeutic implications. The present patient underwent a successful surgical atrial thrombectomy. Our experience underscores that in cases of malfunctioning catheter, echocardiographic screening is mandatory. 相似文献
10.
Impact of Glutathione Modulation on Stability and Pharmacokinetic Profile of Redox‐Sensitive Nanogels 下载免费PDF全文
Natascha Drude Oliver H. Winz Felix M. Mottaghy Marion Roller Hiltrud Königs Martin Möller Smriti Singh Agnieszka Morgenroth 《Small (Weinheim an der Bergstrasse, Germany)》2018,14(14)
Nanoparticles degradable upon external stimuli combine pharmacokinetic features of both small molecules as well as large nanoparticles. However, despite promising preclinical results, several redox responsive disulphide‐linked nanoparticles failed in clinical translation, mainly due to their unexpected in vivo behavior. Glutathione (GSH) is one of the most evaluated antioxidants responsible for disulfide degradation. Herein, the impact of GSH on the in vivo behavior of redox‐sensitive nanogels under physiological and modulated conditions is investigated. Labelling of nanogels with a DNA‐intercalating dye and a radioisotope allows visualization of the redox responsiveness at the cellular and the systemic levels, respectively. In vitro, efficient cleavage of disulphide bonds of nanogels is achieved by manipulation of intracellular GSH concentration. While in vivo, the redox‐sensitive nanogels undergo, to a certain extent, premature degradation in circulation leading to rapid renal elimination. This instability is modulated by transient inhibition of GSH synthesis with buthioninsulfoximin. Altered GSH concentration significantly changes the in vivo pharmacokinetics. Lower GSH results in higher elimination half‐life and altered biodistribution of the nanogels with a different metabolite profile. These data provide strong evidence that decreased nanogel degradation in blood circulation can limit the risk of premature drug release and enhance circulation half‐life of the nanogel. 相似文献
11.
Qing Zhang Huijun Zhou Hao Chen Xiao Zhang Shuqing He Lina Ma Chunrong Qu Wei Fang Yanjiang Han Da Wang Yuanjian Huang Yueming Sun Quli Fan Yue Chen Zhen Cheng 《Small (Weinheim an der Bergstrasse, Germany)》2019,15(45)
Bimodal imaging with fluorescence in the second near infrared window (NIR‐II) and positron emission tomography (PET) has important significance for tumor diagnosis and management because of complementary advantages. It remains challenging to develop NIR‐II/PET bimodal probes with high fluorescent brightness. Herein, bioinspired nanomaterials (melanin dot, mesoporous silica nanoparticle, and supported lipid bilayer), NIR‐II dye CH‐4T, and PET radionuclide 64Cu are integrated into a hybrid NIR‐II/PET bimodal nanoprobe. The resultant nanoprobe exhibits attractive properties such as highly uniform tunable size, effective payload encapsulation, high stability, dispersibility, and biocompatibility. Interestingly, the incorporation of CH‐4T into the nanoparticle leads to 4.27‐fold fluorescence enhancement, resulting in brighter NIR‐II imaging for phantoms in vitro and in situ. Benefiting from the fluorescence enhancement, NIR‐II imaging with the nanoprobe is carried out to precisely delineate and resect tumors. Additionally, the nanoprobe is successfully applied in tumor PET imaging, showing the accumulation of the nanoprobe in a tumor with a clear contrast from 2 to 24 h postinjection. Overall, this hierarchically nanostructured platform is able to dramatically enhance fluorescent brightness of NIR‐II dye, detect tumors with NIR‐II/PET imaging, and guide intraoperative resection. The NIR‐II/PET bimodal nanoprobe has high potential for sensitive preoperative tumor diagnosis and precise intraoperative image‐guided surgery. 相似文献