首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We studied the effect of ventilation and air filtration systems on indoor air quality in a children's day-care center in Finland. Ambient air nitrogen oxides (NO, NO2) and particles (TSP, PM10) were simultaneously measured outdoors and indoors with automatic nitrogen oxide analyzers and dust monitoring. Without filtration nitrogen oxides and particulate matter generated by nearby motor traffic penetrated readily indoors. With chemical filtration 50-70% of nitrogen oxides could be removed. Mechanical ventilation and filtration also reduced indoor particle levels. During holidays and weekends when there was no opening of doors and windows and no particle-generating activity indoors, the indoor particle level was reduced to less than 10% of the outdoor level. At times when outdoor particle concentrations were high during weekdays, the indoor level was about 25% of the outdoor level. Thus, the possible adverse health effects of nitrogen oxides and particles indoors could be countered by efficient filtration. We also showed that inclusion of heat recovery equipment can make new ventilation installations economical.  相似文献   

2.
Zhang Q  Zhu Y 《Indoor air》2012,22(1):33-42
This study examined five schools with different ventilation systems in both urban and rural areas in South Texas. Total particle number concentration, ultrafine particle (UFP, diameter < 100 nm) size distribution, PM(2.5) , and CO(2) were measured simultaneously inside and outside of various school microenvironments. Human activities, ventilation settings, and occupancy were recorded. The study found a greater variation of indoor particle number concentration (0.6 × 10(3) -29.3 × 10(3) #/cm(3) ) than of outdoor (1.6 × 10(3) -16.0 × 10(3) #/cm(3) ). The most important factors affecting indoor UFP levels were related to various indoor sources. Gas fan heaters increased the indoor-to-outdoor ratio (I/O ratio) of total particle number concentrations to 30.0. Food-related activities, cleaning, and painting also contributed to the increased indoor particle number concentration with I/O ratios larger than 1.0. Without indoor sources, the I/O ratios for total particles varied from 0.12 to 0.66 for the five ventilation systems studied. The I/O ratio decreased when the outdoor total particle number concentration increased. Particles with diameters <60 nm were less likely to penetrate and stay airborne in indoor environments than larger particles and were measured with smaller I/O ratios. PRACTICAL IMPLICATIONS: From an exposure assessment perspective, schools are important and little-studied microenvironments where students congregate and spend a large proportion of their active time. This study provides information for indoor and outdoor ultrafine particle concentrations at different types of school microenvironments. These data may allow future epidemiological studies to better estimate exposure and assess ultrafine particles health effects among students.  相似文献   

3.
In order to compare patterns of indoor air perception, including perceptions of temperature, air movement, indoor air quality (IAQ), mental concentration, and comfort, 33 subjects either with persistent allergic rhinitis or controls were exposed to different temperatures and constant relative humidity in an experimental office environment. Results were obtained by means of a self-administered visual analogue scale, analyzed using mean score comparisons and principal component analysis. At 14 degrees C, the rhinitis group reported higher scores for sensations of air dryness than controls. At 18 degrees C, in the rhinitis group, there was a correlation between dry, stagnant air, and difficult mental concentration. This group also correlated heat, dry air, and poor IAQ, in contrast to the control group, which correlated comfort, easy mental concentration, and freshness. At 22 degrees C, the rhinitis group correlated heat, dryness, stagnant air, and overall discomfort. This group also correlated non-dry air, freshness, and comfort, whereas the control group correlated heat, humidity, good indoor air, freshness, and comfort. This study suggests that the rhinitis group perceives indoor temperatures of 14 degrees C as dryer than controls do, and that at 18 and 22 degrees C this group positively correlates different adverse perceptions of IAQ. By means of a self-administered questionnaire in an experimental condition, the present study compares subjective patterns of indoor air perception from individuals with respiratory allergy (allergic rhinitis) to control individuals. It reports different patterns of perception of indoor air quality (IAQ) between the two groups, suggesting that allergic individuals could have different IAQ perception.  相似文献   

4.
Assessment of indoor air quality in typical classrooms is vital to students’ health and their performance. The present study was designed to monitor indoor and outdoor size-resolved particle concentrations in a naturally ventilated classroom and investigate factors influencing their levels and relationships. The experiments were performed, at normal ventilation condition with doors and windows opened, on the top floor of a public school building near a busy commercial area of Chiang Mai, Thailand. The particle number concentrations were measured using an optical counter with four size intervals between 0.3 and 5.0 μm. The dataset was collected during weekdays and weekends with a 24 h sampling period over November and December 2005. It was observed that the median indoor particle number concentrations during daytime for 0.3–0.5, 0.5–1.0, 1.0–2.5, and 2.5–5.0 μm size intervals were about 1.6×108, 1.7×107, 1.2×106, and 4.1×105 particles/m3, respectively. It was also found that concentrations at weekends were slightly higher those measured on weekdays, and at night, appeared to be higher than daytime. Indoor particles were observed to exhibit similar temporal variation pattern with outdoor particles. Results suggested that a significant contribution to indoor particles was from penetration of outdoor particles, whereas indoor sources generated from occupant activity did not show strong evidence. High outdoor particle loading and high air exchange rate were thought to be predominant causes. Ratios of indoor-to-outdoor (I/O) particle concentrations varied in a relatively narrow range from 0.69 to 0.88 with average values well below 1. The I/O ratios were in the range from 0.74 to 0.88 for submicrometer particles and from 0.69 to 0.80 for supermicrometer particles.  相似文献   

5.
Indoor/outdoor measurements have been performed in the Oslo metropolitan area during summer and winter periods (2002-2003) at two different residential houses. The objective of the measurement study was to characterize, physically and chemically, the particulate matter (PM) and gaseous pollutants associated with actual human exposure in the selected places, and their indoor/outdoor relationship. In this paper, we focus on the PM measurements and examine the relationship between the indoor and outdoor PM concentrations taking into account the ventilation rate, indoor sources and meteorological conditions. The indoor/outdoor measurements indicate the important contribution of the outdoor air to the indoor air quality and the influence of specific indoor sources such as smoking and cooking to the concentration of PM inside houses. However, no specific correlation was found between the indoor/outdoor concentration ratio and the meteorological parameters. This study provides information on the physical characteristics and the relationship of indoor to outdoor concentration of particulate matter in residential houses. Moreover, the parameters that influence this relationship are discussed. The results presented here are specific to the sampled houses and conditions used and provide data on the actual human exposure characteristics which occur in the spatial and temporal scales of the present study.  相似文献   

6.
Poor indoor air quality (IAQ) in schools is related to increased symptom reporting in students. We investigated whether parental worry about school IAQ influences this association. Data came from survey collected from five Finnish primary schools with observed IAQ problems and five control schools. Parents (n = 1868) of primary school students reported worry about IAQ in schools and symptoms of their children. Associations between observed IAQ problems, worry, and five symptom scores (ie, respiratory, lower respiratory, eye, skin, and general symptoms) were analyzed using multivariate logistic regression and mediation analysis. Parents were on average more worried in schools with observed IAQ problems. Observed IAQ problems were strongly associated with increased worry and all symptoms under study (unadjusted ORs ranged between 1.48 [95% CI 1.48‐2.16] and 2.70 [95% CI 1.52‐5.17]). Parental worry was associated with all symptoms (unadjusted ORs ranged between 2.49 [95% CI 1.75‐3.60] and 4.92 [95% CI 2.77‐9.40]). Mediation analyses suggested that parental worry might partially explain the association between observed IAQ problems and symptom reporting (proportion mediated ranged between 67% and 84% for the different symptoms). However, prospective studies are needed to assess causal relationships between observed IAQ problems, worry, and symptom reporting in schools.  相似文献   

7.
To evaluate the separate impacts on human health and establish effective control strategies, it is crucial to estimate the contribution of outdoor infiltration and indoor emission to indoor PM2.5 in buildings. This study used an algorithm to automatically estimate the long-term time-resolved indoor PM2.5 of outdoor and indoor origin in real apartments with natural ventilation. The inputs for the algorithm were only the time-resolved indoor/outdoor PM2.5 concentrations and occupants’ window actions, which were easily obtained from the low-cost sensors. This study first applied the algorithm in an apartment in Tianjin, China. The indoor/outdoor contribution to the gross indoor exposure and time-resolved infiltration factor were automatically estimated using the algorithm. The influence of outdoor PM2.5 data source and algorithm parameters on the estimated results was analyzed. The algorithm was then applied in four other apartments located in Chongqing, Shenyang, Xi'an, and Urumqi to further demonstrate its feasibility. The results provided indirect evidence, such as the plausible explanations for seasonal and spatial variation, to partially support the success of the algorithm used in real apartments. Through the analysis, this study also identified several further development directions to facilitate the practical applications of the algorithm, such as robust long-term outdoor PM2.5 monitoring using low-cost light-scattering sensors.  相似文献   

8.
How building stakeholders (e.g. owners, tenants, operators, and designers) understand impacts of Indoor Air Quality (IAQ) and associated energy costs is unknown. We surveyed 112 stakeholders across the United States to ascertain their perceptions of their current IAQ and estimates of benefits and costs of, as well as willingness to pay for, IAQ improvements. Respondents' perceived IAQ scores correlated with the use of high‐efficiency filters but not with any other IAQ‐improving technologies. We elicited their estimates of the impacts of a ventilation–filtration upgrade (VFU), that is, doubling the ventilation rate from 20 to 40 cfm/person (9.5 to 19 l/s/person) and upgrading from a minimum efficiency reporting value 6 to 11 filter, and compared responses to estimates derived from IAQ literature and energy modeling. Minorities of respondents thought the VFU would positively impact productivity (45%), absenteeism (23%), or health (39%). Respondents' annual VFU cost estimates (mean = $257, s.d. = $496, median = $75 per person) were much higher than ours (always <$32 per person), and the only yearly cost a plurality of respondents said they would pay for the VFU was $15 per person. Respondents holding green building credentials were not more likely to affirm the IAQ benefits of the VFU and were less likely to be willing to pay for it.  相似文献   

9.
Indoor air quality (IAQ) parameters in 73 primary classrooms in Porto were examined for the purpose of assessing levels of volatile organic compounds (VOCs), aldehydes, particulate matter, ventilation rates and bioaerosols within and between schools, and potential sources. Levels of VOCs, aldehydes, PM2.5, PM10, bacteria and fungi, carbon dioxide (CO2), carbon monoxide, temperature and relative humidity were measured indoors and outdoors and a walkthrough survey was performed concurrently. Ventilation rates were derived from CO2 and occupancy data. Concentrations of CO2 exceeding 1000 ppm were often encountered, indicating poor ventilation. Most VOCs had low concentrations (median of individual species <5 μg/m3) and were below the respective WHO guidelines. Concentrations of particulate matter and culturable bacteria were frequently higher than guidelines/reference values. The variability of VOCs, aldehydes, bioaerosol concentrations, and CO2 levels between schools exceeded the variability within schools. These findings indicate that IAQ problems may persist in classrooms where pollutant sources exist and classrooms are poorly ventilated; source control strategies (related to building location, occupant behavior, maintenance/cleaning activities) are deemed to be the most reliable for the prevention of adverse health consequences in children in schools.  相似文献   

10.
Theatres are the most complex of all auditorium structures environmentally. They usually have high heat loads, which are of a transient nature as audiences come and go, and from lighting which changes from scene to scene, and they generally have full or nearly full occupancy. Theatres also need to perform well acoustically, both for the spoken word and for music, and as sound amplification is less used than in other auditoria, background noise control is critically important. All these factors place constraints on the ventilation design, and if this is poor, it can lead to the deterioration of indoor air quality and thermal comfort. To analyse the level of indoor air quality and thermal comfort in a typical medium-sized mechanically ventilated theatre, and to identify where improvements could typically be made, a comprehensive post-occupancy evaluation study was carried out on a theatre in Belgrade. The evaluation, based on the results of monitoring (temperature, relative humidity, CO2, air speed and heat flux) and modelling (CFD), as well as the assessment of comfort and health as perceived by occupants, has shown that for most of the monitored period the environmental parameters were within the standard limits of thermal comfort and IAQ. However, two important issues were identified, which should be borne in mind by theatre designers in the future. First, the calculated ventilation rates showed that the theatre was over-ventilated, which will have serious consequences for its energy consumption, and secondly, the displacement ventilation arrangement employed led to higher than expected complaints of cold discomfort, probably due to cold draughts around the occupants’ feet.  相似文献   

11.
Used filters can be a strong sensory pollutant source. Oxidation processes, especially those initiated by ozone, may contribute to the pollutants emitted from such filters. In the present study, ozone was added to the airstream passing through used ventilation filters. Two flow rates were examined. While the upstream ozone concentration was approximately 75 ppb, the concentrations downstream of the filter were initially 35-50% lower. However, within an hour downstream concentrations were only 5-10% lower than those upstream. These filter samples were then placed for 48 h in nitrogen, ambient air containing less than 5 ppb ozone, or ambient air at an elevated temperature. This resulted in partial regeneration of the ozone removal capability of the filter. In analogous experiments, lower ozone removal occurred when the filter samples were first ventilated for 24 h with ozone-free air before making the measurements. Samples from a new filter removed <10% of the ozone in the airstream, and removal remained relatively constant over time. In companion studies, human subjects assessed the air passing through various used filter samples. In the initial evaluation each of the four filter samples, taken from the same filter and ventilated for 24 h, were assessed to be equivalent. The next evaluation was immediately after the samples had been kept for 24 h in either nitrogen, air, air at an elevated temperature or ozone. The nitrogen-treated filter was assessed to be best, while the ozone-treated filter was assessed to be the worst. The final evaluation occurred after ambient air had passed through the 'treated' filters for 2 h. All such ventilated filters were assessed to be more acceptable than immediately after the 24-h treatments; the ozonized and air-treated filters were the most polluting of the four. Practical Implications The present paper supports previous findings that loaded ventilation filters can be significant sources of sensory pollution. Replacing a loaded filter with a new filter temporarily removes this source of pollution. However, the present study does not provide an answer to how frequently changes are needed under different conditions. The results indicate that in cases of intermittent operation of ventilation systems, the airflow through the polluted filters should be restarted in sufficient time prior to occupancy to purge odorous pollutants that have accumulated on the filter surface. Removal of ozone upstream of the particle filters may further improve perceived air quality in the space downstream of the filter bank. Future efforts related to the development and application of low-polluting filtration systems are warranted.  相似文献   

12.
Ozone in indoor environments: concentration and chemistry   总被引:1,自引:0,他引:1  
Weschler CJ 《Indoor air》2000,10(4):269-288
The concentration of indoor ozone depends on a number of factors, including the outdoor ozone concentration, air exchange rates, indoor emission rates, surface removal rates, and reactions between ozone and other chemicals in the air. Outdoor ozone concentrations often display strong diurnal variations, and this adds a dynamic excitation to the transport and chemical mechanisms at play. Hence, indoor ozone concentrations can vary significantly from hour-to-hour, day-to-day, and season-to-season, as well as from room-to-room and structure-to-structure. Under normal conditions, the half-life of ozone indoors is between 7 and 10 min and is determined primarily by surface removal and air exchange. Although reactions between ozone and most other indoor pollutants are thermodynamically favorable, in the majority of cases they are quite slow. Rate constants for reactions of ozone with the more commonly identified indoor pollutants are summarized in this article. They show that only a small fraction of the reactions occur at a rate fast enough to compete with air exchange, assuming typical indoor ozone concentrations. In the case of organic compounds, the "fast" reactions involve compounds with unsaturated carbon-carbon bonds. Although such compounds typically comprise less than 10% of indoor pollutants, their reactions with ozone have the potential to be quite significant as sources of indoor free radicals and multifunctional (-C=O, -COOH, -OH) stable compounds that are often quite odorous. The stable compounds are present as both gas phase and condensed phase species, with the latter contributing to the overall concentration of indoor submicron particles. Indeed, ozone/alkene reactions provide a link between outdoor ozone, outdoor particles and indoor particles. Indoor ozone and the products derived from reactions initiated by indoor ozone are potentially damaging to both human health and materials; more detailed explication of these impacts is an area of active investigation.  相似文献   

13.
This study evaluated the interrelations between indoor and outdoor bioaerosols in a bedroom under a living condition. Two wideband integrated bioaerosol sensors were utilized to measure indoor and outdoor particulate matter (PM) and fluorescent biological airborne particles (FBAPs), which were within a size range of 0.5-20 μm. Throughout this one-month case study, the median proportion of FBAPs in PM by number was 19% (5%; the interquartile range, hereafter) and 17% (3%) for indoors and outdoors, respectively, and those by mass were 78% (12%) and 55% (9%). According to the size-resolved data, FBAPs dominated above 2 and 3.5 μm indoors and outdoors, respectively. Comparing indoor upon outdoor ratios among occupancy and window conditions, the indoor FBAPs larger than 3.16 μm were dominated by indoor sources, while non-FBAPs were mainly from outdoors. The occupant dominated the indoor source of both FBAPs and non-FBAPs. Under awake and asleep, count- and mass-based mean emission rates were 45.9 and 18.7 × 106 #/h and 5.02 and 2.83 mg/h, respectively. Based on indoor activities and local outdoor air quality in Singapore, this study recommended opening the window when awake and closing it during sleep to lower indoor bioaerosol exposure.  相似文献   

14.
Perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity were studied in a normally furnished office space (108 m3) ventilated with an outdoor airflow of 3, 10 or 30 L/s per person, corresponding to an air change rate of 0.6, 2 or 6 h-1. The temperature of 22 degrees C, the relative humidity of 40% and all other environmental parameters remained unchanged. Five groups of six female subjects were each exposed to the three ventilation rates, one group and one ventilation rate at a time. Each exposure lasted 4.6 h and took place in the afternoon. Subjects were unaware of the intervention and remained thermally neutral by adjusting their clothing. They assessed perceived air quality and SBS symptoms at intervals, and performed simulated normal office work. Increasing ventilation decreased the percentage of subjects dissatisfied with the air quality (P < 0.002) and the intensity of odour (P < 0.02), and increased the perceived freshness of air (P < 0.05). It also decreased the sensation of dryness of mouth and throat (P < 0.0006), eased difficulty in thinking clearly (P < 0.001) and made subjects feel generally better (P < 0.0001). The performance of four simulated office tasks improved monotonically with increasing ventilation rates, and the effect reached formal significance in the case of text-typing (P < 0.03). For each two-fold increase in ventilation rate, performance improved on average by 1.7%. This study shows the benefits for health, comfort and productivity of ventilation at rates well above the minimum levels prescribed in existing standards and guidelines. It confirms the results of a previous study in the same office when the indoor air quality was improved by decreasing the pollution load while the ventilation remained unchanged.  相似文献   

15.
Concentrations of NO2, O3, SO2, acetic and formic acids, HNO3 and NH3 were measured inside and outside a historical building, the Baroque Library Hall (BLH) in the National Library in Prague (Czech Republic). The naturally ventilated system of the building, the restriction of personnel access, reduced groups of visitors and absence of activities which could influence indoor pollutant concentrations are characteristics that make the Baroque Library Hall a suitable location to study the influence of outdoor environment on the indoor air quality. The relationship between indoor and outdoor (I/O) concentration was investigated to assess the infiltration of outdoor generated pollutants. Outdoor and indoor pollution sources were determined and, infiltration of ammonium nitrate and a shift of the equilibrium to the gas phase were the reason for the high concentration of ammonia measured inside the BLH. A significant seasonal variation was observed and interpreted as a consequence of different infiltration regime associated with indoor–outdoor temperature differences, which in addition drives dilution processes of indoor generated pollutants. Based on the indoor air quality assessment performed in the BLH with regard to human and material exposure, there is reason for concern about material preservation and in particular paper at the BLH.  相似文献   

16.
Zuraimi MS  Tham KW  Chew FT  Ooi PL 《Indoor air》2007,17(4):317-327
This paper reports the effects of ventilation strategies on indoor air quality (IAQ) and respiratory health of children within 104 child care centers (CCCs) in a hot and humid climate. The CCCs were categorized by ventilation strategies: natural (NV), air-conditioned and mechanically ventilated (ACMV), air-conditioned using split units (AC), and hybrid (NV and AC operated intermittently). The concentration levels of IAQ parameters in NV CCCs are characterized by the influence of the outdoors and good dilution of indoor pollutants. The lower ventilation rates in air-conditioned CCCs result in higher concentrations of occupant-related pollutants but lower outdoor pollutant ingress. This study also revealed lower prevalence for most asthma and allergy, and respiratory symptoms in children attending NV CCCs. In multivariate analyses controlled for the effects of confounders, the risk of current rhinitis among children is significantly higher if they attend mechanically ventilated CCCs compared to NV CCCs. Air-conditioned CCCs were also associated with higher adjusted prevalence ratio of severe phlegm and cough symptoms and lower respiratory illness. Finally, children attending CCCs with hybrid ventilation are at high risk for almost all the respiratory symptoms studied. PRACTICAL IMPLICATIONS: This large field study indicates that different ventilation strategies employed by child care centers can cause significant variations in the indoor air quality and prevalence of asthma, allergies and respiratory symptoms of attending children. The higher prevalence rates of allergic and respiratory symptoms among young children, whose immune system is still under-developed, in child care centers, whether fully or partially air-conditioned, suggest that ventilation and plausible growth and propagation mechanisms of allergens and infectious agents be further investigated.  相似文献   

17.
Lindgren T  Norbäck D 《Indoor air》2002,12(4):263-272
The aim was to determine cabin air quality and in-flight exposure for cabin attendants of specific pollutants during intercontinental flights. Measurements of air humidity, temperature, carbon dioxide (CO2), respirable particles, ozone (O3), nitrogen dioxide (NO2) and formaldehyde were performed during 26 intercontinental flights with Boeing 767-300 with and without tobacco smoking onboard. The mean temperature in cabin was 22.2 degrees C (range 17.4-26.8 degrees C), and mean relative air humidity was 6% (range 1-27%). The CO2 concentration during cruises was below the recommended limit of 1000 ppm during 96% of measured time. Mean indoor concentration of NO2 and O3, were 14.1 and 19.2 micrograms/m3, with maximum values of 37 and 66 micrograms/m3, respectively. The concentration of formaldehyde was below the detection limit (< 5 micrograms/m3), in most samples (77%), and the maximum value was 15 micrograms/m3. The mean concentration of respirable particles in the rear part of the aircraft (AFT galley area) was much higher (49 micrograms/m3) during smoking as compared with non-smoking conditions (3 micrograms/m3) (P < 0.001), with maximum values of 253 and 7 micrograms/m3. In conclusion, air humidity is very low on intercontinental flights, and the large variation of temperature shows a need for better temperature control. Tobacco smoking onboard leads to a significant pollution of respirable particles, particularly in the rear part of the cabin. The result supports the view that despite the high air exchange rate and efficient air filtration, smoking in commercial aircraft leads to a significant pollution and should be prohibited.  相似文献   

18.
Schools are the most suitable type of building for the application of energy efficiency and good indoor air quality measures. This is justified by the fact that such measures can promote sustainability to the future citizens, and even more, ensure a comfortable and healthy environment for educational purposes. Unfortunately, in practice school buildings face the same, or even more intense, energy performance and indoor air quality problems as any other building. The purpose of this study is to investigate the energy efficiency, thermal environment and indoor air quality in public nursery and elementary school buildings in the city of Kozani, located at the cold climatic zone of Greece. The survey, conducted both by in-field measurements and by questionnaires, reveals the main parameters affecting the overall performance of the investigated buildings. The problematic building envelope, the improper control of heating and lighting systems, the absence of proper legislative measures and, above all, the lack of interest concerning the efficiency of such buildings are the main factors in the reported efficiency.  相似文献   

19.
Previous studies have found that classrooms are often inadequately ventilated, with the resultant increased risk of negative impacts on the pupils. This paper describes a series of field measurements that investigated the indoor air quality, thermal comfort and acoustic performance of nine recently built secondary schools in England. The most significant conclusion is that the complex interaction between ventilation, thermal comfort and acoustics presents considerable challenges for designers. The study showed that while the acoustic standards are demanding it was possible to achieve natural ventilation designs that met the criteria for indoor ambient noise levels when external noise levels were not excessive. Most classrooms in the sample met the requirement of limiting the daily average CO2 concentration to below 1500 ppm but just a few met the need to readily provide 8 l/s per person of fresh air under the easy control of the occupants. It would seem that the basic requirement of 1500 ppm of CO2 is achieved as a consequence of the window areas being just sufficient to provide the minimum of 3 l/s per person at low and intermittent occupancy. Thermal comfort in the monitored classrooms was mostly acceptable but temperatures tended to be much higher in practice than the design assumed.  相似文献   

20.
The contamination of indoor environments with chemical compounds released by materials and furniture, such as semi‐volatile organic compounds (SVOCs), is less documented in schools than in dwellings—yet children spend 16% of their time in schools, where they can also be exposed. This study is one of the first to describe the contamination of the air and dust of 90 classrooms from 30 nursery and primary schools by 55 SVOCs, including pesticides, phosphoric esters, musks, polycyclic aromatic hydrocarbons (PAHs), polychlorobiphenyls (PCBs), phthalates, and polybromodiphenylethers (PBDEs). Air samples were collected using an active sampling method, and dust samples were collected via two sampling methods (wiping and vacuum cleaning). In air, the highest concentrations (median >100 ng/m3) were measured for diisobutyl phthalate (DiBP), dibutyl phthalate (DBP), diethyl phthalate (DEP), bis(2‐ethylhexyl) phthalate (DEHP), and galaxolide. In dust, the highest concentrations (median >30 μg/g) were found for DEHP, diisononyl phthalate (DiNP), DiBP, and DBP. An attempt to compare two floor dust sampling methods using a single unit (ng/m²) was carried out. SVOC concentrations were higher in wiped dust, but frequencies of quantification were greater in vacuumed dust.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号