首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
The scanning electrochemical microscope (SECM) in the lithographic mode is used to assess quantitatively, from both theoretical and experimental points of view, the kinetics of irreversible transformation of electroactive molecular moieties immobilized on a surface as self-assembled monolayers (SAMs). The SECM tip allows the generation of an etchant that transforms the surface locally and irreversibly. The resulting surface patterning is detectable by different surface analyses. The quantification of the surface transformation kinetics is deduced from the evolution of the pattern dimensions with the etching time. The special case of slow etching kinetics is presented; it is predicted that the pattern evolution follows the expansion of the etchant at the substrate surface. The case of a chemically unstable etchant is considered. The model is then tested by inspecting the slow reductive patterning of a perfluorinated SAM. Good agreement is found with different independent SECM interrogation modes, depending on the insulating or conducting nature of the covered substrate. The surface transformation measurements are also compared to the reduction of solutions of perfluoroalkanes. The three-orders-of-magnitude-slower electron transfer observed at the immobilized molecules likely describes the large reorganization associated with the generation of a perfluoroalkyl-centered radical anion.  相似文献   

2.
A new procedure is described to deposit paramagnetic beads on surfaces to form microscopic agglomerates. By using surface-modified beads, microscopic structures with defined biochemical activity are formed. The shape and size of agglomerates were characterized by scanning electron microscopy (SEM), and the biochemical activity was mapped with scanning electrochemical microscopy (SECM). This approach is demonstrated using beads modified with anti-mouse antibodies (Ab). After allowing them to react with a conjugate of mouse IgG and alkaline phosphatase (ALP), the beads were deposited as agglomerates of well-defined size and shape. The biochemical activity was recorded in the generation-collection SECM mode by oxidizing 4-aminophenol formed in the ALP-catalyzed hydrolysis of 4-aminophenyl phosphate at the surface of the beads. The signal height correlated with both the amount of beads present in one agglomerate and the proportion of Ab binding sites saturated with the ALP mouse IgG conjugate. The feedback mode of the SECM was used to image streptavidin-coated beads after reaction with biotinylated glucose oxidase.  相似文献   

3.
The use of catechols, and more specifically of dopamine, as a specific redox mediator for scanning electrochemical microscopy (SECM) investigations was evaluated in the challenging situation of an ultrathin layer deposited on a conductive substrate (carbon materials). Experiments show that dopamine is a well-adapted redox system for SECM in feedback mode and in unbiased conditions. Used as a redox mediator, catechol permits the investigations of modified surfaces without an electrical connection of the sample thanks to fast charge transfer kinetics but with a surface selectivity that does not exist in classical outer-sphere redox mediators. The interest of catechol in SECM as a sensitive redox mediator is exemplified by monitoring several modification steps of an ultrathin (<1 nm) hierarchically porous organic monolayer deposited on carbon substrates. For quantitative analysis, the SECM approach curves using dopamine could simply be characterized with an irreversible electron transfer kinetics model in a large range of pH.  相似文献   

4.
An approximate theory for the feedback mode of the scanning electrochemical microscope (SECM) is developed to interpret the effects of substrate shielding on an ultramicroelectrode tip during a recording of iT versus d curves (approach curves) for reversible and quasireversible kinetics at a substrate surface. The resulting expressions for the tip current, iT, show a good fit to more accurate SECM simulations as well as to the experimental response of a reversible and quasireversible reaction. SECM shielding experiments thus give an interesting new insight into SECM approach curves over electrodes at different potentials, which suggest possible applications to measuring heterogeneous kinetics for fast reactions and diffusion coefficient determination.  相似文献   

5.
Microfloccules of TiO(2) nanoparticles, on which glycerol-dehydrogenase (GDH), 1,3-propanediol-oxidoreductase (PDOR), and glycerol-dehydratase (GDHt) were coimmobilized, were prepared by adsorption-flocculation with polyacrylamide (PAM). The catalytic activity of immobilized enzyme in the glycerol redox reaction system, the enzyme leakage, stabilities of pH and temperature, as well as catalytic kinetics of immobilized enzymes relative to the free enzymes were evaluated. Enzyme loading on the microfloccules as much as 104.1 mg/g TiO(2) (>90% loading efficiency) was obtained under the optimal conditions. PAM played a key role for the formation of microfloccules with relatively homogeneous distribution of size and reducing the enzyme leakage from the microfloccules during the catalysis reaction. The stabilities of GDH against pH and temperature was significantly higher than that those of free GDH. Kinetic study demonstrated that simultaneous NAD(H) regeneration was feasible in glycerol redox system catalysted by these multienzyme microfloccules and the yield of 1, 3-popanediol (1, 3-PD) was up to 11.62 g/L. These results indicated that the porous and easy-separation microfloccules of TiO(2) nanoparticles with immobilized multienzymes were efficient in term of catalytic activity as much as the free enzymes. Moreover, compared with free enzyme, the immobilized multienzymes system exhibited the broader pH, higher temperature stability.  相似文献   

6.
Scanning electrochemical microscopy (SECM) has been employed in the feedback mode to assess the electrochemical behavior of two-dimensional networks of single-walled carbon nanotubes (SWNTs). It is shown that, even though the network comprises both metallic and semiconducting SWNTs, at high density (well above the percolation threshold for metallic SWNTs) and with approximately millimolar concentrations of redox species the network behaves as a thin metallic film, irrespective of the formal potential of the redox couple. This result is particularly striking since the fractional surface coverage of SWNTs is only approximately 1% and SECM delivers high mass transport rates to the network. Finite element simulations demonstrate that under these conditions diffusional overlap between neighboring SWNTs is significant so that planar diffusion prevails in the gap between the SECM tip and the underlying SWNT substrate. The SECM feedback response diminishes at higher concentrations of the redox species. However, wet gate measurements show that at the solution potentials of interest the conductivity is sufficiently high that lateral conductivity is not expected to be limiting. This suggests that reaction kinetics may be a limiting factor, especially since the low surface coverage of the SWNT network results in large fluxes to the SWNTs, which are characterized by a low density of electronic states. For electroanalytical purposes, significantly, two-dimensional SWNT networks can be considered as metallic films for typical millimolar concentrations employed in amperometry and voltammetry. Moreover, SWNT networks can be inexpensively and easily formed over large scales, opening up the possibility of further electroanalytical applications.  相似文献   

7.
Imaging of localized hybridization of nucleic acids immobilized on gold-DNA chip was performed by means of the feedback mode of scanning electrochemical microscopy (SECM). Thiol-tethered oligodeoxynucleotide (HS-ODN) probes, spotted on a gold surface, were hybridized with unmodified target sequence via sandwich hybridization with a biotinylated signaling probe. Spots where sequence-specific hybridization had occurred were developed by adding a streptavidin-alkaline phosphatase conjugate and biocatalyzed precipitation of an insoluble and insulating product. As a consequence, the surface conductivity of the spotted region of the chip where hybridization had taken place changed. These changes in conductivity were sensitively detected by the SECM tip. The proposed method allows imaging of a DNA array in a straightforward way. Analysis of real samples was also performed coupling this method with polymerase chain reaction. The imaging of 60 nM PCR amplicon (255 bp) was demonstrated.  相似文献   

8.
The fabrication and characterization of novel micropipet probes for use in scanning electrochemical microscopy (SECM) are described. These can be used to dispense small (pL) amounts of a solution while monitoring the electrochemical response at a substrate and at a ring electrode tip on the micropipet probe. The probes were constructed by insulating gold-coated borosilicate micropipets with electrophoretic paint and exposing a ring electrode at the tip by heat treatment. Characterization of the probes was performed using scanning electron microscopy, cyclic voltammetry, and SECM approach curve experiments. Routine construction of tips with diameters of the order of 3 microm was possible using this technique. The probes exhibited stable steady-state currents and positive and negative feedback approach curves that agreed with those predicted by theory. Demonstrative SECM imaging experiments were performed using a picodispenser to continuously dispense an electroactive solution (ferrocenemethanol) to the SECM cell while the probe was located within a few micrometers of a Pt substrate surface. Oxidation of the dispensed electroactive solution was performed at the substrate, and feedback currents were measured at the probe tip by holding the gold ring at a reducing potential. This mode of tip-dispensing SECM was used to obtain images of a platinum substrate electrode while monitoring both the substrate current and the feedback current at the probe.  相似文献   

9.
Local feedback mode is introduced as a novel operation mode of scanning electrochemical microscopy (SECM) for electrochemical characterization of a single one-dimensional (1D) nanostructure, for example, a wire, rod, band, and tube with 1-100-nm width and micrometer to centimeter length. To demonstrate the principle, SECM feedback effects under diffusion limitation were studied theoretically and experimentally with a disk probe brought near a semi-infinitely long band electrode as a geometrical model for a conductive 1D nanostructure. As the band becomes narrower than the disk diameter, the feedback mechanism for tip current enhancement is predicted to change from standard positive feedback mode, to positive local feedback mode, and then to negative local feedback mode. The negative local feedback effect is the only feedback effect that allows observation of a 1D nanostructure without serious limitations due to small lateral dimension, available tip size, or finite electron-transfer rate. In line-scan and approach-curve experiments, an unbiased Pt band electrode with 100-nm width and 2.6-cm length was detectable in negative local feedback mode, even using a 25-microm-diameter disk Pt electrode. Using a 2-microm-diameter probe, both well-defined and defected sites were observed in SECM imaging on the basis of local electrochemical activity of the nanoband electrode. Noncontact and spatially resolved measurement is an advantage of this novel SECM approach over standard electrochemical approaches using electrodes based on 1D nanostructure.  相似文献   

10.
Lee Y  Ding Z  Bard AJ 《Analytical chemistry》2002,74(15):3634-3643
A technique that combines scanning electrochemical microscopy (SECM) and scanning optical microscopy (OM) was developed. Simultaneous scanning electrochemical/optical microscopy (SECM/OM) was performed by a special probe tip, which consists of an optical fiber core for light passage, surrounded by a gold ring electrode, and an outermost electrophoretic insulating sheath, with the tip attached to a tuning fork. To regulate the tip-substrate distance, either the shear force or the SECM tip current was employed as the feedback signal. The application of a quartz crystal tuning fork (32.768 kHz) for sensing shear force allowed simultaneous topographic, along with SECM and optical imaging in a constant-force mode. The capability of this technique was confirmed by obtaining simultaneously, for the first time, topographic, electrochemical, and optical images of an interdigitated array electrode. Current feedback from SECM also provided simultaneous electrochemical and optical images of relatively soft samples, such as a polycarbonate membrane filter and living diatoms in a constant-current mode. This mode should be useful in mapping the biochemical activity of a living cell.  相似文献   

11.
The electrochemical behavior of electrodes made by sealing carbon nanofibers in glass or with electrophoretic paint has been studied by scanning electrochemical microscopy (SECM). Because of their small electroactive surface area, conical geometry with a low aspect ratio and high overpotential for proton and oxygen reduction, carbon nanofiber (CNF) electrodes are promising candidates for producing electrode nanogaps, imaging with high spatial resolution and for the electrodeposition of single metal nanoparticles (e.g., Pt, Pd) for studies as electrocatalysts. By using the feedback mode of the SECM, a CNF tip can produce a gap that is smaller than 20 nm from a platinum disk. Similarly, the SECM used in a tip-collection substrate-generation mode, which subsequently shows a feedback interaction at short distances, makes it possible to detect a single CNF by another CNF and then to form a nanometer gap between the two electrodes. This approach was used to image vertically aligned CNF arrays. This method is useful in the detection in a homogeneous solution of short-lifetime intermediates, which can be electrochemically generated at one electrode and collected at the second at distances that are equivalent to a nanosecond time scale.  相似文献   

12.
Zhang M  Smith A  Gorski W 《Analytical chemistry》2004,76(17):5045-5050
Multiwalled carbon nanotubes (CNT) were solubilized in aqueous solutions of a biopolymer chitosan (CHIT). The CHIT-induced solubilization of CNT facilitated their manipulations, including the modification of electrode surfaces for sensor and biosensor development. The colloidal solutions of CNT-CHIT were placed on the surface of glassy carbon (GC) electrodes to form robust CNT-CHIT films, which facilitated the electrooxidation of NADH. The GC/CNT-CHIT sensor for NADH required approximately 0.3 V less overpotential than the GC electrode. The susceptibility of CHIT to chemical modifications was explored in order to covalently immobilize glucose dehydrogenase (GDH) in the CNT-CHIT films using glutaric dialdehyde (GDI). The stability and sensitivity of the GC/CNT-CHIT-GDI-GDH biosensor allowed for the interference-free determination of glucose in the physiological matrix (urine). In pH 7.40 phosphate buffer solutions, linear least-squares calibration plots over the range 5-300 microM glucose (10 points) had slopes 80 mA M(-1) cm(-2) and a correlation coefficient 0.996. The detection limit was 3 microM glucose (S/N = 3). The CNT-CHIT system represents a simple and functional approach to the integration of dehydrogenases and electrodes, which can provide analytical access to a large group of enzymes for wide range of bioelectrochemical applications including biosensors and biofuel cells.  相似文献   

13.
A scanning electrochemical microscopy (SECM) methodology for localized quantitative kinetic studies of electrode reactions based on the tip generation-substrate collection (TG-SC) operation mode is presented. This approach does not use the mediator feedback required in typical kinetic SECM experiments. The reactant is galvanostatically electrogenerated on a tip placed in proximity to the substrate. It diffuses through the tip-substrate gap and undergoes the reaction of interest on the substrate surface. The substrate current is monitored with time until it reaches an apparent steady-state value. The process was digitally simulated using an explicit finite difference method, for an irreversible first-order electrode reaction at the substrate. Transient responses, steady-state polarization curves, and TG-SC approach curves can be used to obtain substrate kinetics. The effects of the experimental parameters were analyzed. The possibility of easily changing the experimental conditions with the SECM is an attractive approach to obtain independent evidence that can be used for a strict test of reaction mechanisms. The technique was applied for a preliminary simplified kinetic examination of the oxygen reduction reaction in phosphoric acid.  相似文献   

14.
15.
Enzyme-based reagentless biosensors were developed using the model system of glucose dehydrogenase (GDH) and its nicotinamide adenine dinucleotide cofactor (NAD+). The biosensors were prepared following an approach similar to the concept of molecular imprinting. To this end, the N1-carboxymethyl-NAD+ species were covalently attached to polyamino-saccharide chains of chitosan (CHIT) and allowed to interact with GDH in an aqueous solution. The bioaffinity interactions between the NAD+ and GDH were secured by cross-linking the system with the glutaric dialdehyde (GDI)-modified CHIT. Electron conductive films of such CHIT-NAD+-GDH-GDI-CHIT macrocomplexes (MC) were prepared on glassy carbon (GC) electrodes by adding carbon nanotubes (CNT) and evaporating water. Electrochemical analysis of the GC/CNT-MC electrodes revealed that, in contrast to the oxidase-based electrodes, they acted as oxygen-independent reagentless biosensors. The application of Nafion to such biosensors predictably improved their selectivity and, unexpectedly, enhanced their sensitivity by an order of magnitude.  相似文献   

16.
This Article reports the use of scanning electrochemical microscopy (SECM) for the quantitative study of acid-induced dissolution. An ultramicroelectrode (UME) is used to generate a flux of protons galvanostatically just above a sample surface, creating controlled acid challenges relevant to acid erosion. The electrochemical technique produces etch features in the sample, which are characterized by white light interferometry (WLI). The technique has been applied to bovine enamel where understanding the kinetics of dissolution is important in the context of acid erosion. Dissolution has been observed as a fast process, but the high rates of mass transport in SECM allow the surface kinetics of dissolution to be evaluated. Key attributes of SECM for these studies are the ability to deliver high, controllable, and local acid challenges in a defined way and that multiple dissolution measurements can be performed on one sample, eliminating intersample variability effects. A novel moving boundary finite element model has been designed to describe the etching process, which allows the etch kinetics to be evaluated quantitatively, simply by measuring the size and shape of etch features over time.  相似文献   

17.
To detect the target molecules, aptamers are currently focused on and the use of aptamers for biosensing is particularly interesting, as aptamers could substitute antibodies in bioanalytical sensing. So this paper describes the novel electrochemical system for protein in sandwich manner by using the aptamers and the scanning electrochemical microscope (SECM). For protein detection, sandwich system is ideal since labeling of the target protein is not necessary. To develop the electrochemical protein sensor system, thrombin was chosen as a target protein since many aptamers for it were already reported and two different aptamers, which recognize different positions of thrombin, were chosen to construct sandwich type sensing system. In order to obtain the electrochemical signal, the glucose oxidase (GOD) used for labeling the detection aptamers since it has large amount of stability in aqueous solution. One aptamer was immobilized onto the gold electrode and the other aptamer for detection was labeled with GOD for generation of the electric signal. Thrombin was detected in sandwich manner with aptamer immobilized onto the gold electrode and the GOD labeled aptamer. The enzymatic signal, generated from glucose addition after the formation of the complex of thrombin, was measured. The generation-collection mode of SECM was used for amperometric H2O2 detection.  相似文献   

18.
The use of the scanning electrochemical microscope (SECM) to probe the kinetics of charge-transfer processes at bilayer lipid membranes (BLM) is presented. Analysis of the SECM tip response demonstrates that an unmodified BLM behaves as an insulator, whereas a BLM doped with iodine shows some positive feedback. The SECM technique thus allows one to probe processes at a BLM and determine the kinetics of the charge-transfer process. The SECM can also be used to determine the shape of the BLM.  相似文献   

19.
The two known phases of CuTCNQ and TCNQ (TCNQ = 7,7',8,8'-tetracyanoquinodimethane) have been probed by scanning electrochemical microscopy (SECM) in the feedback mode. The first use of this technique for distinguishing differences in the electronic properties of semiconductor phases exploits the large differences in conductivity that exist between CuTCNQ and the parent TCNQ material and also between the CuTCNQ phases I and II. However, the packing density of the individual CuTCNQ crystals in a film structure also is shown to influence the SECM feedback response. Finally, it is shown that films of pure phase II material or mixtures of the phases can be mapped using feedback mode SECM. The SECM method provides valuable insights for elucidating properties of semiconducting solids that are mounted on insulating substrates.  相似文献   

20.
P Sun  Z Zhang  J Guo  Y Shao 《Analytical chemistry》2001,73(21):5346-5351
A novel method for fabrication of nanometer-sized electrodes and tips suitable for scanning electrochemical microscopy (SECM) is reported. A fine etched Pt wire is coated with polyimide, which was produced by polymerization on the Pt surface initiated by heat. This method can prepare electrodes with effective radii varying from a few to hundreds of nanometers. Scanning electron microscopy, cyclic voltammetry, and SECM were used to characterize these electrodes. Well-defined steady-state voltammograms could be obtained in aqueous or in 1,2-dichloroethane solutions. This method produced the nanoelectrodes with exposed Pt on the apex, and they can also be employed as the nanotips for SECM investigations. Different sizes of Pt nanotips made by this method were employed to evaluate the kinetics of the redox reaction of Ru(NH3)6(3+) on the surface of a large Pt electrode by SECM, and the standard rate constant kappa0 of this system was calculated from the best fit of the SECM approach curve. This result is similar to the values obtained by analysis of the obtained voltammetric data.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号