共查询到20条相似文献,搜索用时 0 毫秒
1.
Nepomuceno AI Muddiman DC Bergen HR Craighead JR Burke MJ Caskey PE Allan JA 《Analytical chemistry》2003,75(14):3411-3418
Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) has rapidly established a prominent role in proteomics because of its unparalleled resolving power, sensitivity and ability to achieve high mass measurement accuracy (MMA) simultaneously. However, space-charge effects must be quantitatively, routinely, and confidently corrected because they are known to profoundly influence MMA. We argue that the most effective way to account for space-charge effects is to introduce an internal mass calibrant (IMC) using a dual electrospray ionization (ESI) source where the IMC is added from a separate ESI emitter. The major disadvantage of our initial dual ESI source to achieve high MMA, and arguably the only one, was the time required to switch between the analyte emitter and IMC emitter (i.e., >300 ms). While this "switching time" was acceptable for direct infusion experiments, it did not lend itself to high-throughput applications or when conducting on-line liquid separations. In this report, we completely redesigned the dual ESI source and demonstrate several key attributes. First, the new design allows for facile alignment of ESI emitters, undetectable vibration, and the ability to extend to multiple emitters. Second, the switching time was reduced to <50 ms, which allowed the analyte and IMC to be accumulated "simultaneously" in the external ion reservoir and injected as a single ion packet into the ion cyclotron resonance cell, eliminating the need for a separate accumulation and ion injection event for the IMC. Third, by using a high concentration of the IMC, the residence time on this emitter could be reduced to approximately 80 ms, allowing for more time spent accumulating analyte ions of significantly lower concentration. Fourth, multiplexed on-line separations can be carried out providing increased throughput. Specifically, the new dual ESI source has demonstrated its ability to produce a stable ion current over a 45-min time period at 7 T resulting in mass accuracies of 1.08 ppm +/- 0.11 ppm (mean +/- confidence interval of the mean at 95% confidence; N = 160). In addition, the analysis of a tryptic digest of apomyoglobin by nanoLC-dual ESI-FT-ICR afforded an average MMA of -1.09 versus -74.5 ppm for externally calibrated data. Furthermore, we demonstrate that the amplitude of a peptide being electrosprayed at 25 nM can be linearly increased, ultimately allowing for dynamic analyte/IMC abundance modulation. Finally, we demonstrate that this source can reliably be used for multiplexing measurements from two (eventually more) flow streams. 相似文献
2.
Commercial explosives are complex mixtures that contain not only the active explosive agent(s) but also a host of other organic and inorganic compounds. The ultrahigh mass resolving power (m/delta m50% >200,000) and mass accuracy (<1 ppm) of electrospray ionization Fourier transform ion cyclotron resonance (ESI FTICR) mass spectrometry allow for definitive identification of various species in TNT, RDX, and HMX. We are thereby able to correct prior misassignments of the elemental compositions of the most abundant negative ions from electrospray of RDX and HMX. Although the (known) active agents of many explosives may be identified by low-resolution MS or MS/MS, it is the other characteristic components (indigenous or artificial additives) whose presence and elemental composition can potentially identify the source of the product. ESI FTICR mass spectrometry of smokeless powder, TNT, and Powermite resolves and identifies numerous nonactive ingredients, many of which are recovered in a postblast residue. In contrast, the residue recovered from an explosion of military C4 yielded several species derived from RDX but virtually none from other ingredients. 相似文献
3.
Smith DF Schaub TM Rodgers RP Hendrickson CL Marshall AG 《Analytical chemistry》2008,80(19):7379-7382
We describe automation of liquid injection field desorption/ionization (LIFDI) for reproducible sample application, improved spectral quality, and high-throughput analyses. A commercial autosampler provides reproducible and unattended sample application. A custom-built field desorption (FD) controller allows data station or front panel control of source parameters including high-voltage limit/ramp rate, emitter heating current limit/ramp rate, and feedback control of emitter heating current based on ion current measurement. Automated LIFDI facilitates ensemble averaging of hundreds of Fourier transform ion cyclotron resonance mass spectra for increased dynamic range, mass accuracy, and S/N ratio relative to single-application FD experiments, as shown here for a South American crude oil. This configuration can be adapted to any mass spectrometer with an LIFDI probe. 相似文献
4.
Probing proteomes using capillary isoelectric focusing-electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry. 总被引:6,自引:0,他引:6
P K Jensen L Pasa-Toli? G A Anderson J A Horner M S Lipton J E Bruce R D Smith 《Analytical chemistry》1999,71(11):2076-2084
Unlike the genome, the proteome is exquisitely sensitive to cellular conditions and will consist of proteins having abundances dependent upon stage in the cell cycle, cell differentiation, response to environmental conditions (nutrients, temperature, stress etc.), or disease state(s). Therefore, the study of proteomes under well-defined conditions can provide a better understanding of complex biological processes and inference of protein function. Thus, much faster, more sensitive, and precise capabilities for the characterization of cellular constituents are desired. We describe progress in the development and initial application of the powerful combination of capillary isoelectric focusing (CIEF) and Fourier transform ion cyclotron resonance (FTICR) mass spectrometry for measurements of the proteome of the model system Escherichia coli. Isotope depletion of the growth media has been used to improve mass measurement accuracy, and the comparison of CIEF-FTICR results for the analysis of cell lysates harvested from E. coli cultured in normal and isotopically depleted media are presented. The initial studies have revealed 400-1000 putative proteins in the mass range 2-100 kDa from total injections of approximately 300 ng of E. coli proteins in a single CIEF-FTICR analysis. 相似文献
5.
As one of the most important platinum drugs, the interactions of cisplatin with proteins play very important roles in its anticancer action and side effects. Here, the interaction of cisplatin with cytochrome c was investigated using Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS). On the basis of the high-resolution data, cytochrome c-Pt(NH(3))Cl was found to be the primary monoadduct. The platinated monoadducts were related to molar ratios of cytochrome c and cisplatin, and corresponding reaction pathways were proposed. Multiple binding sites of cisplatin on cytochrome c were directly determined by FTICR MS combined with trypsin digestion without liquid chromatography (LC) separation. Four binding sites (Met65, Met80, His18, and His33) for cisplatin on cytochrome c were identified. Moreover, hydrogen/deuterium exchange (H/DX) combined with FTICR MS provides the sensitive method to insight the small conformation change of cytochrome c induced by cisplatin. This strategy can be applied to comprehensive investigation of metallodrug/protein complexes. 相似文献
6.
Masselon C Pasa-Tolić L Tolić N Anderson GA Bogdanov B Vilkov AN Shen Y Zhao R Qian WJ Lipton MS Camp DG Smith RD 《Analytical chemistry》2005,77(2):400-406
In proteomics, effective methods are needed for identifying the relatively limited subset of proteins displaying significant changes in abundance between two samples. One way to accomplish this task is to target for identification by MS/MS only the "interesting" proteins based on the abundance ratio of isotopically labeled pairs of peptides. We have developed the software and hardware tools for online LC-FTICR MS/MS studies in which a set of initially unidentified peptides from a proteome analysis can be selected for identification based on their distinctive changes in abundance following a "perturbation". We report here the validation of this method using a mixture of standard proteins combined in different ratios after isotopic labeling. We also demonstrate the application of this method to the identification of Shewanella oneidensis peptides/proteins exhibiting differential abundance in suboxic versus aerobic cell cultures. 相似文献
7.
Carbohydrate analysis by desorption electrospray ionization fourier transform ion cyclotron resonance mass spectrometry 总被引:1,自引:0,他引:1
We report the use of desorption electrospray ionization hybrid Fourier transform ion cyclotron resonance mass spectrometry (DESI-FT-ICR-MS) for the analysis of carbohydrates. Spectra of neat carbohydrates are presented along with their mass measurement accuracies and limits of detection. Furthermore, a comparison is made between the analyses of O-linked glycans from mucin by DESI-FT-ICR-MS and matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance mass spectrometry. Finally, glycans from mucin are identified by using the high mass measurement accuracy and tandem MS capabilities afforded by the hybrid FT-ICR-MS platform. 相似文献
8.
Here we propose a novel method for rapidly identifying proteins in complex mixtures. A list of candidate proteins (including provision for posttranslational modifications) is obtained by database searching, within a specified mass range about the accurately measured mass (e.g., +/- 0.1 Da at 10 kDa) of the intact protein, by capillary liquid chromatography electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (LC ESI FT-ICR MS). On alternate scans, LC ESI infrared multiphoton dissociation (IRMPD) FT-ICR MS yields mostly b and y fragment ions for each protein, from which the correct candidate is identified as the one with the highest "hit" score (i.e., most b and y fragments matching the candidate database protein amino acid sequence masses) and sequence "tag" score (based on a series of fragment sequences differing in mass by 1 or 2 amino acids). The method succeeds in uniquely identifying each of a mixture of five proteins treated as unknowns (melittin, ubiquitin, GroES, myoglobin, carbonic anhydrase II), from more than 1000 possible database candidates within a +/- 500 Da mass window. We are also able to identify posttranslational modifications of two of the proteins (mellitin and GroES). The method is simple, rapid, and definitive and is extendable to a mixture of affinity-selected proteins, to identify proteins with a common biological function. 相似文献
9.
On-line combination of capillary isoelectric focusing (CIEF) with electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry is demonstrated for high-resolution analysis of model proteins, human hemoglobin variants, and Escherichia coli proteins. The acquisition of high-resolution mass spectra of hemoglobin beta chains allows direct identification of hemoglobin variants A and C, differing in molecular mass by 1 Da. Direct mass determination of cellular proteins separated in the CIEF capillary is achieved using their isotopic envelopes obtained from ESI-FTICR. The factors which dictate overall performance of CIEF-ESI-FTICR, including duty cycle, mass resolution, scan rate, and sensitivity, are discussed in the context of protein variants and cell lysates analyzed in this study. 相似文献
10.
Smith DF Robinson EW Tolmachev AV Heeren RM Paša-Tolić L 《Analytical chemistry》2011,83(24):9552-9556
Secondary ion mass spectrometry (SIMS) has seen increased application for high spatial resolution chemical imaging of complex biological surfaces. The advent and commercial availability of cluster and polyatomic primary ion sources (e.g., Au and Bi cluster and buckminsterfullerene (C(60))) provide improved secondary ion yield and decreased fragmentation of surface species, thus improving accessibility of intact molecular ions for SIMS analysis. However, full exploitation of the advantages of these new primary ion sources has been limited, due to the use of low mass resolution mass spectrometers without tandem MS to enable enhanced structural identification capabilities. Similarly, high mass resolution and high mass measurement accuracy would greatly improve the chemical specificity of SIMS. Here we combine, for the first time, the advantages of a C(60) primary ion source with the ultrahigh mass resolving power and high mass measurement accuracy of Fourier transform ion cyclotron resonance mass spectrometry. Mass resolving power in excess of 100?000 (m/Δm(50%)) is demonstrated, with a root-mean-square mass measurement accuracy below 1 part-per-million. Imaging of mouse brain tissue at 40 μm pixel size is shown. Tandem mass spectrometry of ions from biological tissue is demonstrated and molecular formulas were assigned for fragment ion identification. 相似文献
11.
The utility of electrospray ionization Fourier transform ion cyclotron resonance (ESI-FIICR) mass spectrometry as a new approach for genotyping short tandem repeats (STRs) is demonstrated. STRs are currently valued as a powerful source of genetic information with repeats that range in structure from simple to hypervariable. Two tetranucleotide STR loci were chosen to evaluate ESI-FTICR mass spectrometry as a tool for genotyping: HUM-TH01, a simple STR with nonconsensus alleles, and vWA, a compound STR with nonconsensus alleles. For HUM-TH01, the genotype (i.e., repeat number of each allele) was determined for each of 30 individuals using mass measurements of double-stranded amplicons. Low-intensity peaks observed in the spectra of amplicons derived from heterozygous individuals were identified by mass as heteroduplexes that had formed between nonhomologous strands. Mass measurement of the double-stranded vWA amplicon was not sufficient for determining whether the individual was homozygous for allele subtype 18 or 18' since the amplicons differ by only 0.99 Da. Therefore, single-stranded amplicons were generated by incorporating a phosphorylated primer, prepared using T4 polynucleotide kinase, into the PCR phase and subsequently digesting the bottom strand using lambda-exonuclease. Accurate mass measurements were obtained for the single-stranded amplicons using internal calibration and the addition of a correction factor to adjust for the natural variation of isotopic abundances, confirming that the individual is homozygous for allele 18. Our results clearly demonstrate that ESI-FTICR mass spectrometry is a powerful approach to characterize both simple and compound STRs beyond the capabilities of electrophoretic technologies. 相似文献
12.
Modifications to a 7 T nano-LC micro-ESI FT-ICR mass spectrometer, including a shorter octopole, approximately 100% duty cycle, improved nano-LC micro-ESI emitter tips, and reverse-phase HPLC resins that require no ion-pairing agent, combine to achieve attomole detection limit. Three peptides in a mixture totaling 500 attomoles (amol) each in water (10 microL, 50 amol/microL) are separated and detected, demonstrating detection from a mixture at low endogenous biological concentration. Two peptides in a mixture totaling 500 amol each in artificial cerebrospinal fluid (1 microL, 500 amol/microL) are separated and detected, demonstrating detection from a mixture at a biological concentration in a biological solvent. The highest sensitivity is attained with arg8-vasotocin, in which a total of 300 amol is detected in artificial cerebrospinal fluid (1 microL, 300 amol/microL) and a total of 100 amol in water (1 microL, 100 amol/microL). Arg8-vasotocin isolated from the pineal gland of rainbow trout is detected, demonstrating the ability of FT-ICR to detect and identify a true endogenous biological analyte. 相似文献
13.
Zeptomole-sensitivity electrospray ionization--Fourier transform ion cyclotron resonance mass spectrometry of proteins 总被引:1,自引:0,他引:1
Methods are being developed for ultrasensitive protein characterization based upon electrospray ionization (ESI) with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS). The sensitivity of a FTICR mass spectrometer equipped with an ESI source depends on the overall ion transmission, which combines the probability of ionization, transmission efficiency, and ion trapping in the FTICR cell. Our developments implemented in a 3.5 tesla FTICR mass spectrometer include introduction and optimization of a newly designed electrodynamic ion funnel in the ESI interface, improving the ion beam characteristics in a quadrupole-electrostatic ion guide interface, and modification of the electrostatic ion guide. These developments provide a detection limit of approximately 30 zmol (approximately 18,000 molecules) for proteins with molecular weights ranging from 8 to 20 kDa. 相似文献
14.
A novel technique was developed for characterization of saturated hydrocarbons. Linear alkanes were selectively oxidized to ketones by ruthenium ion catalyzed oxidation (RICO). Branched and cyclic alkanes were oxidized to alcohols and ketones. The ketones were then reduced to alcohols by lithium aluminum hydride (LiAlH(4)). The monohydric alcohols (O(1)) in the products obtained from the RICO and RICO-LiAlH(4) reduction reactions were characterized using negative-ion electrospray ionization (ESI) Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) for identification of iso-paraffins, acyclic paraffins and cyclic paraffins. Various model saturated compounds were used to determine the RICO reaction and ionization selectivity. The results from the FTICR MS analysis on the petroleum distillates derived saturated fraction were in agreement with those from field ionization gas chromatography time-of-flight mass spectrometry (FI GC-TOF MS) analysis. The technique was also used to characterize a petroleum vacuum residue (VR) derived saturates. The results showed that the saturated molecules in the VR contained up to 11 cyclic rings, and the maximum carbon number was up to 92. 相似文献
15.
Belov ME Zhang R Strittmatter EF Prior DC Tang K Smith RD 《Analytical chemistry》2003,75(16):4195-4205
When combined with capillary LC separations, electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR MS) has demonstrated capabilities for advanced characterization of proteomes based upon analyses of proteolytic digests. Incorporation of external (to the ICR cell) multipole devices with FTICR for ion selection and ion accumulation has enhanced the dynamic range, sensitivity, and duty cycle of measurements. However, the highly variable ion production rate from an LC separation can result in "overfilling" of the external trap during the elution of major peaks and result in m/z discrimination and fragmentation of peptide ions. Excessive space charge trapped in the ICR cell also causes significant shifts in the detected ion cyclotron frequencies, reducing the achievable mass measurement accuracy (MMA) and making protein identification less effective. To eliminate m/z discrimination in the external ion trap, further increase duty cycle, and improve MMA, we have developed the capability for data-dependent adjustment of ion accumulation times in the course of an LC separation, referred to as automated gain control (AGC). This development has been implemented in combination with low kinetic energy gated ion trapping and internal calibration using a dual-channel electrodynamic ion funnel. The overall system was initially evaluated in the analysis of a tryptic digest of bovine serum albumin. In conjunction with internal calibration, the capillary LC-ESI-AGC-FTICR instrumentation provided a approximately 10-fold increase in the number of identified tryptic peptides compared to that obtained using a fixed ion accumulation time and external calibration methods. 相似文献
16.
The Hartley transform offers a useful alternative to the Fourier transform for the conversion of a time-domain ion cyclotron resonance (ICR) signal into its corresponding frequency-domain mass spectrum. The Hartley transform has the advantage that it eliminates the need for complex variables, when (as for linearly polarized signals) the time-domain signal can be represented by a mathematically real function. Moreover, the Hartley transform produces the same spectra (absorption mode, dispersion mode, magnitude mode) as does the Fourier transform. In particular, the discrete fast Hartley transform (FHT) produces the same spectrum at twice the speed of a complex fast Fourier transform (FFT), making the FHT equivalent in speed to a "real" FFT. Hartley and Fourier transform methods in ICR mass spectrometry are compared and demonstrated experimentally. Essentially the same advantages and computational methods should apply to the use of the Hartley transform in place of the Fourier transform in other forms of spectrometry (e.g., nuclear magnetic resonance, infrared, etc.). 相似文献
17.
Monolithic silica-based capillary reversed-phase liquid chromatography/electrospray mass spectrometry for plant metabolomics 总被引:11,自引:0,他引:11
Application of C18 monolithic silica capillary columns in HPLC coupled to ion trap mass spectrometry detection was studied for probing the metabolome of the model plant Arabidopsis thaliana. It could be shown that the use of a long capillary column is an easy and effective approach to reduce ionization suppression by enhanced chromatographic resolution. Several hundred peaks could be detected using a 90-cm capillary column for LC separation and a noise reduction and automatic peak alignment software, which outperformed manual inspection or commercially available mass spectral deconvolution software. 相似文献
18.
Schaub TM Hendrickson CL Horning S Quinn JP Senko MW Marshall AG 《Analytical chemistry》2008,80(11):3985-3990
We describe the design and current performance of a 14.5 T hybrid linear quadrupole ion trap Fourier transform ion cyclotron resonance mass spectrometer. Ion masses are routinely determined at 4-fold better mass accuracy and 2-fold higher resolving power than similar 7 T systems at the same scan rate. The combination of high magnetic field and strict control of the number of trapped ions results in external calibration broadband mass accuracy typically less than 300 ppb rms, and a resolving power of 200,000 (m/Delta m50% at m/z 400) is achieved at greater than 1 mass spectrum per second. Novel ion storage optics and methodology increase the maximum number of ions that can be delivered to the FTICR cell, thereby improving dynamic range for tandem mass spectrometry and complex mixture applications. 相似文献
19.
D G Schmid F D von der Mülbe B Fleckenstein T Weinschenk G Jung 《Analytical chemistry》2001,73(24):6008-6013
Among the numerous forms of chemical degradation of peptides or proteins, deamidation is one of the alterations observed most frequently. In this irreversible reaction, a glutamine or an asparagine side chain is hydrolyzed to glutamic acid or aspartic acid, respectively (conversion of NH2 to OH). Besides its influence in the deterioration of biotechnological and food products, deamidation represents a defined posttranslational modification reaction with respect to proteomics. Here mass spectrometric techniques play a leading role in determining posttranslational modifications. However, not all mass spectrometers are able to resolve signal differences of 0.0193 Da (mass difference of 12CO vs 13CNH) for singly charged molecules, the mass difference between the first isotopic signal of an asparagine/glutamine-containing peptide and the monoisotopic signal of the corresponding partially deamidated aspartate/glutamate derivative. To detect partial deamidation within peptides, advantage has been taken of the ability of Fourier transform ion cyclotron resonance mass spectrometry to perform very high mass resolution. In this work, we investigated up to triply charged ions produced by electrospray ionization using direct infusion. Although the special heterodyne detection mode enables higher mass resolution than the routinely used broadband detection, often only a small mass window can be investigated. Using broadband detection, we were able to resolve ions with a difference of m/z 0.0064 to detect partially deamidated peptides formed either enzymatically or under acidic and basic conditions. 相似文献
20.
Triton polymers are commercial surfactants whose molecular weight distributions are conventionally determined by means of high-performance liquid chromatography (HPLC). However, in the case of the important octylphenol ethoxylates [p-C8H17-C6H4-O-(CH2CH2O)n-H], HPLC cannot resolve individual oligomers of high molecular weight Triton surfactants (e.g., greater than 2000 u or so; u = unified atomic mass unit). In this paper, we show that laser desorption Fourier transform ion cyclotron resonance mass spectrometry (LD/FT/ICR/MS) provides a simple and accurate measure of such Triton surfactant molecular weight distributions up to at least 3500 u, based on a single-shot laser pulse measurement of a few seconds duration. Comparison of LD/FT/ICR/MS and HPLC molecular weight distributions of low molecular weight surfactants shows that laser desorption/ionization produces minimal fragmentation and thus offers an accurate measure of the relative abundances of the neutral oligomers, without the need for prior chromatographic separation of the components. Moreover, for all Triton polymer molecular weight distributions (700-3000 u), LD/FT/ICR/MS provides much more highly resolved profiles of oligomer relative abundances. Finally, LD/FT/ICR/MS reveals the presence of poly(ethylene oxide) side products of the polymerization process, which are not observed by HPLC with conventional ultraviolet absorption detection. 相似文献