首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
We describe high-efficiency (peak capacities of approximately 10(3)) nanoscale (using column inner diameters down to 15 microm) liquid chromatography (nanoLC)/low flow rate electrospray (nanoESI) mass spectrometry (MS) for the sensitive analysis of complex global cellular protein enzymatic digests (i.e., proteomics). Using a liquid slurry packing method with carefully selected packing solvents, 87-cm-length capillaries having inner diameters of 14.9-74.5 microm were successfully packed with 3-microm C18-bonded porous (300-A pores) silica particles at a pressure of 18,000 psi. With a mobile-phase delivery pressure of 10,000 psi, these packed capillaries provided mobile-phase flow rates as low as approximately 20 nL/min at LC linear velocities of approximately 0.2 cm/s, which is near optimal for separation efficiency. To maintain chromatographic efficiency, unions with internal channel diameters as small as 10 microm were specially produced for connecting packed capillaries to replaceable nanoESI emitters having orifice diameters of 2-10 microm (depending on the packed capillary dimensions). Coupled on-line with a hybrid-quadrupole time-of-flight MS through the nanoESI interface, the nanoLC separations provided peak capacities of approximately 10(3) for proteome proteolytic polypeptide mixtures when a positive feedback switching valve was used for quantitatively introducing samples. Over a relatively large range of sample loadings (e.g., 5-100 ng, and 50-500 ng of cellular proteolytic peptides for 14.9- and 29.7-microm-i.d. packed capillaries, respectively), the nanoLC/nanoESI MS response for low-abundance components of the complex mixtures was found to increase linearly with sample loading. The nanoLC/nanoESI-MS sensitivity also increased linearly with decreasing flow rate (or approximately inversely proportional to the square of the capillary inner diameter) in the flow range of 20-400 nL/min. Thus, except at the lower loadings, decreasing the separation capillary inner diameter has an effect equivalent to increasing sample loading, which is important for sample-limited proteomic applications. No significant effects on recovery of eluting polypeptides were observed using porous C18 particles with surface pores of 300-A versus nonporous particles. Tandem MS analyses were also demonstrated using the high-efficiency nanoLC separations. Chromatographic elution time, MS response intensity, and mass measurement accuracy was examined between runs with a single column (with a single nanoESI emitter), between different columns (same and different inner diameters with different nanoESI emitters), and for different samples (various concentrations of cellular proteolytic peptides) and demonstrated robust and reproducible sensitive analyses for complex proteomic samples.  相似文献   

2.
We report on the design and application of a high-efficiency multiple-capillary liquid chromatography (LC) system for high-throughput proteome analysis. The multiple-capillary LC system using commercial LC pumps was operated at a pressure of 10,000 psi to deliver mobile phases through a novel passive feedback valve arrangement that permitted mobile-phase flow path switching and efficient sample introduction. The multiple-capillary LC system uses several serially connected dual-capillary column devices. The dual-capillary column approach eliminates the time delays for column regeneration (or equilibration) since one capillary column was used for a separation while the other was being washed. Several serially connected dual-capillary columns and electrospray ionization (ESI) sources were operated independently and can be used either for "backup" operation or for parallel operation with other mass spectrometers. This high-efficiency multiple-capillary LC system utilizes switching valves for all operations, enabling automated operation. The separation efficiency of the dual-capillary column arrangement, optimal capillary dimensions (column length and packed particle size), capillary regeneration conditions, and mobile-phase compositions and their compatibility with electrospray ionization were investigated. A high magnetic field (11.4 T) Fourier transform ion cyclotron resonance (FTICR) mass spectrometer was coupled on-line with this high-efficiency multiple-capillary LC system using an ESI interface. The capillary LC provided a peak capacity of approximately 650, and the 2-D capillary LC-FTICR analysis provided a combined resolving power of > 6 x 10(7) components. For yeast cytosolic tryptic digests > 100,000 polypeptides were detected, and approximately 1,000 proteins could be characterized from a single capillary LC-FTICR analysis using the high mass measurement accuracy (approximately 1 ppm) of FTICR, and likely more if LC retention time information were also exploited for peptide identification.  相似文献   

3.
The throughput of proteomics measurements that provide broad protein coverage is limited by the quality and speed of both the separations as well as the subsequent mass spectrometric analysis; at present, analysis times can range anywhere from hours (high throughput) to days or longer (low throughput). We have explored the basis for proteomics analyses conducted on the order of minutes using high-speed capillary RPLC combined through on-line electrospray ionization interface with high-accuracy mass spectrometry (MS) measurements. Short 0.8-microm porous C18 particle-packed 50-microm-i.d. capillaries were used to speed the RPLC separations while still providing high-quality separations. Both time-of-flight (TOF) and Fourier transform ion cyclotron resonance (FTICR) MS were applied for identifying peptides using the accurate mass and time (AMT) tag approach. Peptide RPLC relative retention (elution) times that were generated by solvent gradients that differed by at least 25-fold were found to provide relative elution times that agreed to within 5%, which provides the basis for using peptide AMT tags for higher throughput proteomics measurements. For fast MS acquisition speeds (e.g., 0.2 s for TOF and either approximately 0.3 or approximately 0.6 s for FTICR), peptide mass measurement accuracies of better than +/-15 ppm were obtained with the high-speed RPLC separations. The ability to identify peptides and the overall proteome coverage was determined by factors that include the separation peak capacity, the sensitivity of the MS (with fast scanning), and the accuracy of both the mass measurements and the relative RPLC peptide elution times. The experimental RPLC relative elution time accuracies of 5% (using high-speed capillary RPLC) and mass measurement accuracies of better than +/-15 ppm allowed for the confident identification of >2800 peptides and >760 proteins from >13,000 different putative peptides detected from a Shewanellaoneidensis tryptic digest. Initial results for both RPLC-ESI-TOF and RPLC-ESI-FTICR MS were similar, with approximately 2000 different peptides from approximately 600 different proteins identified within 2-3 min. For <120-s proteomic analysis, TOF MS analyses were more effective, while FTICR MS was more effective for the >150-s analysis due to the improved mass accuracies attained using longer spectrum acquisition times.  相似文献   

4.
We describe approaches for proteomics analysis using electrospray ionization-tandem mass spectrometry coupled with fast reversed-phase liquid chromatography (RPLC) separations. The RPLC separations used 50-microm-i.d. fused-silica capillaries packed with submicrometer-sized C18-bonded porous silica particles and achieved peak capacities of 130-420 for analytes from proteome tryptic digests. When these separations were combined with linear ion trap tandem mass spectrometry measurements, approximately 1000 proteins could be identified in 50 min from approximately 4000 identified tryptic peptides; approximately 550 proteins in 20 min from approximately 1800 peptides; and approximately 250 proteins in 8 min from approximately 700 peptides for a S. oneidensis tryptic digest. The dynamic range for protein identification with the fast separations was determined to be approximately 3-4 orders of magnitude of relative protein abundance on the basis of known proteins in human blood plasma analyses. We found that 55% of the MS/MS spectra acquired during the entire analysis (and up to 100% of the MS/MS spectra acquired from the most data-rich zone) provided sufficient quality for identifying peptides. The results confirm that such analyses using very fast (minutes) RPLC separations based on columns packed with microsized porous particles are primarily limited by the MS/MS analysis speed.  相似文献   

5.
Nanoscale packed-capillary liquid chromatography (LC) columns have been coupled with mass spectrometry (MS) using a coaxial continuous-flow fast atom bombardment interface. The combined system has been applied to the analysis of mixtures of peptides, including synthetic mixtures of bioactive peptides and tryptic digests of proteins. Nanoscale packed-capillary columns offer two principal advantages for LC/MS analysis--high chromatographic separation efficiencies and low mobile-phase flow rates. The high separation efficiencies facilitate the separation of complex mixtures, and the low mobile-phase flow rates reduce problems with coupling the LC effluent with the high-vacuum, high-voltage environment of sector MS ion sources. The columns used in this work were 50- or 75-micron i.d., 1-2 m long, packed with 10-micron C18 particles, using mobile-phase flow rates of 50-350 nL/min.  相似文献   

6.
The characterization of cellular proteomes is important for understanding biochemical processes ranging from cell differentiation to cancer development. In one highly promising approach, whole protein extracts or fractions are digested (e.g., with trypsin) and injected into a packed capillary column for subsequent separation. The separated peptides are then introduced on-line to an electrospray ionization source of a Fourier transform ion cyclotron resonance (FTICR) mass spectrometer for the detection of peptide accurate mass tags that serve as biomarkers for their parent proteins. In this work, we report the use of data-dependent selective external ion ejection in conjunction with FTICR and on-line capillary LC separations for the enhanced characterization of peptide mixtures and a yeast extract proteome. The number of peptides identified in an LC-FTICR analysis of a yeast proteome digest employing data-dependent rf-only dipolar ejection of the most abundant ion species prior to ion accumulation was 40% higher than that detected in a separate LC-FTICR analysis using conventional nonselective ion accumulation.  相似文献   

7.
Time-of-flight mass spectrometry (TOF MS) is increasingly used in proteomics research. Herein, we report on the development and characterization of a TOF MS instrument with improved sensitivity equipped with an electrodynamic ion funnel trap (IFT) that employs an automated gain control (AGC) capability. The IFT-TOF MS was coupled to a reversed-phase capillary liquid chromatography (RPLC) separation and evaluated in experiments with complex proteolytic digests. When applied to a global tryptic digest of Shewanella oneidensis proteins, an order-of-magnitude increase in sensitivity compared to that of the conventional continuous mode of operation was achieved due to efficient ion accumulation prior to TOF MS analysis. As a result of this sensitivity improvement and related improvement in mass measurement accuracy, the number of unique peptides identified in the AGC-IFT mode was 5-fold greater than that obtained in the continuous mode.  相似文献   

8.
Proteomics analysis based-on reversed-phase liquid chromatography (RPLC) is widely practiced; however, variations providing cutting-edge RPLC performance have generally not been adopted even though their benefits are well established. Here, we describe an automated format 20 kpsi RPLC system for proteomics and metabolomics that includes on-line coupling of micro-solid phase extraction for sample loading and allows electrospray ionization emitters to be readily replaced. The system uses 50 microm i.d. x 40-200 cm fused-silica capillaries packed with 1.4-3-microm porous C18-bonded silica particles to obtain chromatographic peak capacities of 1000-1500 for complex peptide and metabolite mixtures. This separation quality provided high-confidence identifications of >12 000 different tryptic peptides from >2000 distinct Shewanella oneidensis proteins (approximately 40% of the proteins predicted for the S. oneidensis proteome) in a single 12-h ion trap tandem mass spectrometry (MS/MS) analysis. The protein identification reproducibility approached 90% between replicate experiments. The average protein MS/MS identification rate exceeded 10 proteins/min, and 1207 proteins were identified in 120 min through assignment of 5944 different peptides. The proteomic analysis dynamic range of the 20 kpsi RPLC-ion trap MS/MS was approximately 10(6) based on analyses of a human blood plasma sample, for which 835 distinct proteins were identified with high confidence in a single 12-h run. A single run of the 20 kpsi RPLC-accurate mass MS detected >5000 different compounds from a metabolomics sample.  相似文献   

9.
The coupling of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) with electrospray ionization has advanced the analysis of large biopolymers and provided the basis for high-throughput protein characterization (e.g., for rapid "proteome" analyses). In this work, the combination of high-performance capillary liquid chromatography with FTICR mass spectrometry and external ion accumulation has been shown to increase both sensitivity and analysis duty cycle. Instrument versatility is further improved by ion preselection followed by ion accumulation in an external linear quadrupole ion trap. The interface was tested with a 3.5-T FTICR mass spectrometer and evaluated with a number of peptides and proteins whose molecular weights ranged from 500 to 66000. A significant increase in the sensitivity, duty cycle, and dynamic range over that of the previously used accumulated trapping was achieved, exhibiting a detection limit of approximately 10 zmol (approximately 6000 molecules) for smaller proteins such as cytochrome c. Capillary LC external accumulation interface with FTICR was successfully applied for the study of whole-proteome mouse tryptic digests.  相似文献   

10.
A new and simple method was demonstrated for separating phi X-174/Hae III DNA restriction fragments and DNA markers V and VI, respectively, without filling capillaries with polymer solutions prior to analysis. Using this novel method, poly(ethylene oxide) (PEO) solutions containing ethidium bromide migrated into capillaries by electroosmotic flow (EOF) during the separation. Two DNA fragments (123 and 124 bp) in markers V and VI were well-resolved. RSD values for the separation of phi X-174/Hae III DNA restriction fragments were less than 0.52% for 3 runs using a single 75-micron capillary and less than 3.96% using three different 75-micron capillaries. A highly viscous polymer solution prepared from 3% PEO was also used for separation of DNA markers V and VI. Theoretical plates up to 11.91 million/m and separation times of less than 7 min were achieved in the separation of phi X-174/Hae III DNA restriction fragments using a 10-micron capillary and a 2% PEO solution. Advantages of this method include simplicity, short separation times, the ability to use highly viscous polymer solutions for separating small DNA fragments, and the possibility of introducing several different polymer solutions into capillaries to extend the DNA separation range.  相似文献   

11.
Shen Y  Lee ML 《Analytical chemistry》1997,69(13):2541-2549
In this study, column efficiency in packed capillary column solvating gas chromatography (SGC) was investigated. Long (>3 m) fused silica capillaries with an inner diameter of 250 μm were packed with 10 and 15 μm spherical porous (300 ?) octadecyl bonded silica particles using a CO(2) slurry packing method. A 336 cm × 250 μm i.d. fused silica capillary containing 10 μm particles provided a total column efficiency of 264?000 plates (k = 0.41), corresponding to a reduced plate height of 1.27, using CO(2) as the mobile phase at a column inlet pressure of 260 atm. A minimum plate height of 12.7 μm and a maximum plate number per unit time of 813 plates/s were obtained using packed capillary SGC. Retention factors were dependent on the column inlet pressure but independent of the pressure gradient along the column. Gasoline and diesel samples were separated under SGC conditions, and the results were comparable to those obtained using typical open tubular column gas chromatography.  相似文献   

12.
The separation and detection of biuret complexes of neuropeptides by capillary liquid chromatography with electrochemical detection was explored. Capillaries of 25-micron inner diameter packed with base-resistant, polymer-based reversed-phase particles were used for separation, and C-fiber electrodes were used for detection. Detection at the C-fiber electrode was found to have some differences in relative sensitivity for peptides compared to glassy carbon electrodes used previously. On-column preconcentration of preformed complexes allowed up to 1-microL samples to be injected with minimal band broadening resulting in a 100-fold improvement in concentration detection limit with no effect on mass detection limit. Concentration detection limits ranged from 5 to 59 pM, depending upon the peptide, corresponding to 5-59 amol injected. The low concentration detection limit was possible because of minimal baseline disturbances, minimal formation of unwanted products, and high efficiency of complex formation associated with biuret derivatization. The method was applied to determination of vasopressin and bradykinin in dialysates collected with 5-min sampling frequency from the rat supraoptic nucleus.  相似文献   

13.
Qin W  Zhang W  Song L  Zhang Y  Qian X 《Analytical chemistry》2010,82(22):9461-9468
Reversible phosphorylation is one of the most important post-translational modifications of proteins and a key regulator of cellular signaling pathways. Specific enrichment of phosphopeptides from proteolytic digests is a prerequisite for large scale identification of protein phosphorylation by mass spectrometry. Online enrichment of phosphopeptides attracts particular interests due to its automated operation, higher throughput and reproducibility, lower sample loss, and contamination. Here, we report a new type of capillary column developed using surface initiated atom transfer radical polymerization (SI-ATRP) for automated online phosphopeptide enrichment. SI-ATRP modification leads to a surface confined growth of three-dimensional wavelike polymer structure on the inner wall of capillary columns and, therefore, results in largely increased surface area. Furthermore, the noncross-linked flexible polymer chains grown by SI-ATRP create a large internal volume that allows phosphopeptides to penetrate into during enrichment and also facilitate the interaction between the numerous functional groups in the polymer chains and target phosphopeptides. Therefore, highly efficient and specific enrichment is achieved even for a low femtomole of phosphopeptides. The loading capacity is increased more than an order of magnitude compared with that obtained using conventional open tubular capillary columns. The SI-ATRP modified capillary column was successful applied in the online phosphoproteomics analysis of HepG2 cell lysate and resulted in 10 times improved phosphopeptide identification than the previously reported number. Finally, the SI-ATRP technique is compatible with a variety of functional monomers, and therefore, versatile potential applications in reverse phase, ion exchange, and affinity chromatography can be expected.  相似文献   

14.
When combined with capillary LC separations, electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR MS) has demonstrated capabilities for advanced characterization of proteomes based upon analyses of proteolytic digests. Incorporation of external (to the ICR cell) multipole devices with FTICR for ion selection and ion accumulation has enhanced the dynamic range, sensitivity, and duty cycle of measurements. However, the highly variable ion production rate from an LC separation can result in "overfilling" of the external trap during the elution of major peaks and result in m/z discrimination and fragmentation of peptide ions. Excessive space charge trapped in the ICR cell also causes significant shifts in the detected ion cyclotron frequencies, reducing the achievable mass measurement accuracy (MMA) and making protein identification less effective. To eliminate m/z discrimination in the external ion trap, further increase duty cycle, and improve MMA, we have developed the capability for data-dependent adjustment of ion accumulation times in the course of an LC separation, referred to as automated gain control (AGC). This development has been implemented in combination with low kinetic energy gated ion trapping and internal calibration using a dual-channel electrodynamic ion funnel. The overall system was initially evaluated in the analysis of a tryptic digest of bovine serum albumin. In conjunction with internal calibration, the capillary LC-ESI-AGC-FTICR instrumentation provided a approximately 10-fold increase in the number of identified tryptic peptides compared to that obtained using a fixed ion accumulation time and external calibration methods.  相似文献   

15.
Current nano-LC/MS systems require the use of an enrichment column, a separation column, a nanospray tip, and the fittings needed to connect these parts together. In this paper, we present a microfabricated approach to nano-LC, which integrates these components on a single LC chip, eliminating the need for conventional LC connections. The chip was fabricated by laminating polyimide films with laser-ablated channels, ports, and frit structures. The enrichment and separation columns were packed using conventional reversed-phase chromatography particles. A face-seal rotary valve provided a means for switching between sample loading and separation configurations with minimum dead and delay volumes while allowing high-pressure operation. The LC chip and valve assembly were mounted within a custom electrospray source on an ion-trap mass spectrometer. The overall system performance was demonstrated through reversed-phase gradient separations of tryptic protein digests at flow rates between 100 and 400 nL/min. Microfluidic integration of the nano-LC components enabled separations with subfemtomole detection sensitivity, minimal carryover, and robust and stable electrospray throughout the LC solvent gradient.  相似文献   

16.
Cooper JW  Chen J  Li Y  Lee CS 《Analytical chemistry》2003,75(5):1067-1074
A miniaturized trypsin membrane reactor housed inside a commonly used capillary fitting is developed and demonstrated for enabling rapid and sensitive protein identification by on-line proteolytic digestion and analysis of protein digests using nano-ESI-MS and MALDI-MS. The design and assembly of the capillary fitting-based trypsin membrane reactor are straightforward and highly robust, without the need for expensive fabrication technology and procedures. The resultant protein digests can also be further concentrated and resolved using capillary reversed-phase liquid chromatography or transient capillary isotachophoresis/zone electrophoresis prior to the mass spectrometric analysis in an integrated platform. By comparing these results with the results obtained from our previous studies using plastic microfluidics (Gao et al., Anal. Chem. 2001, 73, 2648-2655), significant reduction in dead volume and sample consumption can be achieved using this newly developed tryptic digestion station. This nanoscale reaction system enables rapid proteolytic digestion in seconds instead of hours for a protein concentration of less than 10(-8) M, consumes very little sample (< or = 5 fmol), and offers capillary interfaces with various separation and mass spectrometry techniques. The ultrafast enzymatic turnover for attaining complete peptide coverage in protein identification is contributed by the highly porous structure of the membrane media, providing excessive trypsin loading while eliminating the constraints of diffusion-limited reaction kinetics.  相似文献   

17.
Liu Y  Pietrzyk DJ 《Analytical chemistry》2000,72(24):5930-5938
Macroporous poly(styrene-divinylbenzene) (PSDVB), PRP-1, a reversed-phase adsorbent, and PSDVB-based strong acid cation exchangers and strong base and weak base anion exchangers were evaluated as stationary phases for capillary electrochromatography (CEC). Electroosmotic flow (EOF) for adsorbent and exchanger packed fused-silica capillaries for acetone as the marker increases with increasing ion exchange capacity, buffer organic solvent concentration, and applied voltage, is nearly independent of pH, and decreases with increased buffer ionic strength. For anion exchangers, EOF is reversed. Thiourea, acetone, acrylamide, nitromethane, propanal, and acetic acid were evaluated as EOF markers and undergo weak interaction with the PSDVB-based stationary phases. EOF in a basic buffer is greater than or equal to silica-based C-18 and cation exchanger packed capillaries. For an acidic buffer, EOF for a PRP-1 capillary is almost twice the C-18 packed capillary. As analyte hydrophobicity increases, retention and migration time increases for the PSDVB-based stationary phases. As exchange capacity increases, availability of the polymeric matrix for analyte partitioning decreases, causing analyte migration time to decrease. Increasing buffer organic solvent concentration decreases analyte retention. The PSDVB-based stationary phases provide good resolving power and reproducibility and are applicable to the CEC separation of neutral, weakly acidic, and basic analytes. Efficiency, however, is less than obtained with silica-based stationary phases. Because of stability in a strong acid buffer, the CEC separation of weak acids, where dissociation is suppressed, and weak bases as cations is possible. Separations of short-chain alkyl aldehydes, methyl ketones, aromatic hydrocarbons, substituted benzene derivatives, and short-chain carboxylic acids are described.  相似文献   

18.
The ability to manipulate and effectively utilize small proteomic samples is important for analyses using liquid chromatography (LC) in combination with mass spectrometry (MS) and becomes more challenging for very low flow rates due to extra column volume effects on separation quality. Here we report on the use of commercial switching valves (150-microm channels) for implementing the on-line coupling of capillary LC columns operated at 10,000 psi with relatively large solid-phase extraction (SPE) columns. With the use of optimized column connections, switching modes, and SPE column dimensions, high-efficiency on-line SPE-capillary and nanoscale LC separations were obtained demonstrating peak capacities of approximately 1000 for capillaries having inner diameters between 15 and 150 microm. The on-line coupled SPE columns increased the sample processing capacity by approximately 400-fold for sample solution volume and approximately 10-fold for sample mass. The proteomic applications of this on-line SPE-capillary LC system were evaluated for analysis of both soluble and membrane protein tryptic digests. Using an ion trap tandem MS it was typically feasible to identify 1100-1500 unique peptides in a 5-h analysis. Peptides extracted from the SPE column and then eluted from the LC column covered a hydrophilicity/hydrophobicity range that included an estimated approximately 98% of all tryptic peptides. The SPE-capillary LC implementation also facilitates automation and enables use of both disposable SPE columns and electrospray emitters, providing a robust basis for automated proteomic analyses.  相似文献   

19.
A method with the ability to increase greatly both the resolution and efficiency of a given capillary electrophoretic system is described. This method differs from traditional capillary electrophoresis (CE) in that a counterflow is induced in the direction opposite to the electrokinetic migration of the analyte. This has the effect of extending not only the time the analytes migrate in the electric field but also the effective length and the effective applied voltage of the system. Previous work in our group with flow counterbalanced capillary electrophoresis has utilized an open tube of small inner diameter to reduce peak broadening caused by hydrodynamic flow. Narrow-diameter capillaries (5-10 microm) restricted analysis to fluorescent analytes and laser-induced fluorescence detection. The method described here uses a capillary of much larger inner diameter (75 microm) that has been packed with nonporous silica particles. The packing material reduces the amount of band broadening caused by pressure-induced flow relative to that experienced in an open tube. A larger diameter capillary allows the detection of analytes by UV absorption, not only eliminating the need to tag analytes with fluorescent tags but also allowing for the detection of a much broader range of analytes. The system was evaluated by studying the separations of several enantiomers using only beta-cyclodextrin as the chiral selector. The system was also used to resolve the two naturally occurring isotopes of bromine and to resolve phenylalanine from phenylalanine-d8. Relative to traditional CE, large improvements in resolution and separation efficiency have been achieved with this method.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号