首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 218 毫秒
1.
针对晚期垃圾渗滤液实现深度除碳脱氮,采用上流式厌氧污泥床(upflow anaerobic sludge blanket,UASB)-缺氧/好氧反应器(anoxic/aerobic reactor,A/O)-厌氧氨氧化反应器(anaerobic sequencing batch reactor,ASBR)组合工艺,以短程硝化-厌氧氨氧化耦合反应为依托,通过UASB实现有机物的大部分降解,在A/O中实现短程硝化,在ASBR中通过厌氧氨氧化深度脱氮.研究结果表明:当进水ρ(CODcr)、ρ(NH_4~+-N)和ρ(TN)分别为2 220 mg/L、1 400~1 450 mg/L和1 450~1 500 mg/L;最终出水分别为98、7、25 mg/L,实现了分别为95.6%、98.3%和99.5%的高去除率.故该工艺无须投加任何外碳源,最终实现化学需氧量(chemical oxygen demand,COD)、氨氮(NH_4~+-N)和总氮(total nitrogen,TN)的高效、深度去除.  相似文献   

2.
内循环对A2/O工艺脱氮的影响   总被引:1,自引:0,他引:1  
采用有效容积为52L的A~2/O工艺,以实际生活污水为水源,研究了不同进水ρ(NH_4~+-N)负荷条件下,内循环回流比对系统脱氮效率的影响.实验结果表明,硝化速率随着进水ρ(NH_4~+-N)负荷增加而升高,系统脱氮效率随着内循环回流比增加而升高,内循环回流比从0增加到6,系统脱氮效率升高了14.0%,其中,ρ(NO_x~-N)去除率升高了10.2%,ρ(NH_4~+-N)去除率升高了3.8%.为稳定出水中氮的浓度、降低运行费用,内循环回流比应随进水ρ(NH_4~+-N)负荷的增加而增加,一般情况下内循环回流比易控制在2左右.  相似文献   

3.
垃圾渗滤液是一种成分复杂的高浓度有机废水,若不加处理而直接排入环境,会造成严重的环境污染,研发高效可行的渗滤液处理工艺具有重要意义.通过建立"缺氧(A)/好氧(O)/膜生物反应器(MBR)+反渗透(RO)"中试设备,现场处理实际垃圾渗滤液,探讨进水浓度和温度条件对垃圾渗滤液中污染物去除影响,考察"A/O/MBR+RO"工艺处理垃圾渗滤液的工艺可行性.结果表明:该工艺在冬季时(5~15°C)对COD、NH_3-N、TN去除率仍可达60%、63%和47%左右.冬季低温时,MBR出水中含有一定的NO_2-N,而此时COD满足不了完全反硝化需求,初步说明可能存在一定的短程硝化反硝化.对MBR出水进行RO深度处理后,出水中NH_3-N、COD和TN等水质指标均达到《生活垃圾填埋场污染控制标准》(GB16889-2008)要求.  相似文献   

4.
采用"两级上流式厌氧污泥床(UASB)-缺氧/好氧(A/O)-序批式反应器(SBR)工艺"对城市生活晚期垃圾渗滤液进行了深度处理.运行模式如下:首先在一级UASB(UASB1)中反硝化,UASBI出水中的亚硝态氮和硝态氮利用残余COD在二级UASB(UASB2)中被进一步去除,在A/O反应器中利用残余COD进行反硝化以及将NH4+-N硝化,在SBR中去除硝化产生的亚硝态氮、硝态氮.试验中首先采用原渗滤液进入处理系统(20d),然后采用原渗滤液与生活污水1∶1混合进入系统实现和维持稳定的短程硝化(60d),最后采用原渗滤液与A/O反应器出水1:1混合进入系统实现和维持稳定的短程硝化(60d).140d的试验结果表明:原渗滤液的总氮浓度为2 300 mg·L-1,氨氮浓度在2 000mg·L-1左右时,通过将原渗滤液与生活污水或A/O反应器出水1:1混合,可以在A/O反应器中实现稳定的短程硝化,其中亚硝态氮积累率为70%~88%.后续的SBR工艺,可彻底去除产生的亚硝态氮和硝态氮.最终出水的氨氮浓度不到2 mg·L-1,总氮浓度为18~20mg·L-1,系统氨氮和总氮去除率分别为99.7%和98%.  相似文献   

5.
为了研究厌氧-好氧工艺处理垃圾渗滤液的脱氮性能,采用ASBR联合脉冲进水SBR(脉冲SBR)处理高氨氮实际垃圾渗滤液。ASBR的水力停留时间为2d;中间水箱调节脉冲SBR的进水C/N(3~5)和NH4+-N浓度;脉冲SBR采用3次等量进水模式,运行周期分为4个缺氧段和3个好氧段,不投加外碳源,缺氧4利用污泥内碳源进行反硝化。结果表明,串联运行时期(157d)系统获得了高效的脱氮性能。ASBR进水COD为7 338~10 445mg.L-1,去除率在83%以上;脉冲SBR进水NH4+-N浓度分4个阶段逐步提高至912.0±41.7mg.L-1,总氮(TN)去除率在90%以上,出水总氮小于40mg.L-1;系统COD和总氮去除率分别在87%和97%以上。单个缺氧4进程内的内源反硝化速率(DNR)会由快变慢,而其平均理论内源反硝化速率(TDNRm)达到了1.531mgN.h-1.gMLVSS-1。在不使用物化预处理和不投加外碳源的情况下实现了对渗滤液的深度脱氮。  相似文献   

6.
在温度35℃,pH值7.0左右,HRT为30 h,进水稀释配比R为75%,NO_(2-)-N/NH_(4+)-N为1.6条件下,研究厌氧反应器厌氧氨氧化与反硝化的耦合作用。厌氧反应器中NH_(4+)-N、NO_(2-)-N浓度分别为(75±2)mg/L、(120±2)mg/L,COD为(900±5)mg/L,总氮负荷为(216±5)mg/(L·d),考察不同无机碳源浓度对厌氧段总氮与有机物去除效果的影响。实验结果表明,在无机碳源浓度为12 mmol/L时,厌氧段氨氮、亚硝态氮去除率分别为57.26%、83.07%,TN去除率最高为74.15%,COD去除率为78.12%。随着无机碳源的浓度继续增加到24 mmol/L时,氨氮去除效果显著下降,去除率仅为28.92%。结果表明,适当增加系统无机碳源浓度,可以强化厌氧氨氧化与反硝化的协同作用,提高系统的脱氮性能,而高浓度的无机碳会对系统中菌群产生明显抑制作用。  相似文献   

7.
A^2O工艺处理生活污水反硝化除磷研究   总被引:1,自引:0,他引:1  
采用A2O工艺处理低ρ(C)/ρ(N)实际生活污水,研究其脱氮除磷性能和反硝化除磷特性.试验结果表明:处理低ρ(C)/ρ(N)实际生活污水时,在不设置预缺氧区、无外加碳源的情况下,A2O工艺的脱氮除磷能力受到严重影响,出水ρ(NO3--N)高达35 mg/L,TN平均去除率仅为47.1%;此时A2O工艺除磷能力较差,缺氧段有释磷现象的发生.当设置预缺氧区后,A2O工艺的脱氮除磷能力明显提高,TN平均去除率可达60.7%,PO43--P平均去除率为55.9%;此时系统存在反硝化除磷现象,缺氧段除磷率为31.4%~46.9%.在设置预缺氧区的基础上,通过外加碳源,提高进水ρ(C)/ρ(N),可进一步提高系统的脱氮除磷能力,TN平均去除率可达74.4%,出水ρ(PO34--P)小于0.5 mg/L,缺氧段除磷率高达66.2%~90.9%.同时研究了外加碳源情况下污泥内PHA成分、含量及糖原含量在A2O系统内的沿程变化趋势.经过驯化、富集,反硝化聚磷菌相对于全部聚磷菌的代谢活性从31.1%提高到74.7%.A2O工艺反硝化除磷能力的增强,提高了碳源的利用效率.  相似文献   

8.
为提高A2/O工艺处理低碳氮(磷)比污水的同步脱氮除磷效率,使出水达到GB18918—2002一级A标准,采用2种模式A2/O工艺处理实验废水.模式1为投加填料的A2/O工艺,反应器在优化工况tHR=8.2 h、污泥回流比R=80%、硝化液回流比r=250%~300%、ρ(DO)=1.5~0.5 mg/L条件下运行,出水TP质量浓度仍超标.模式2为模式1的改良——末端间歇曝气填料A2/O工艺,好氧段后增设1个间歇曝气段,并改变污泥回流和排泥方式,系统在长污泥龄tSR=22.3 d、A2/O段优化工况、间歇曝气段tHR=4 h、曝气周期1 h(曝气1 min(ρ(DO)=0.3~0.5 mg/L)、沉淀59 min)的条件下,COD、NH4+-N、TP和TN的平均去除率分别达87.8%,99.1%,95.5%和90.8%,出水亚硝化率在70%以上,污泥中反硝化除磷菌与聚磷菌比达95.65%.系统实现了短程硝化反硝化途径的氮磷同步去除,出水满足国家一级A标准.  相似文献   

9.
为了解决垃圾渗滤液在无外加碳源的条件下难以实现高效生物脱氮的问题,采用中试规模的A/O-MBR反应器,通过实现短程硝化反硝化去除垃圾渗滤液中的高浓度有机物和氮化物,并考察反应器系统对水质变化的适应能力以及不同进水碳氮比时的去除效果.实验结果表明:在进水氨氮质量浓度为1 500 mg/L、碳氮比为2∶1、水力停留时间(HRT)为4.21 d的条件下,COD和TN去除率均达到80%以上,说明系统实现了低碳氮比垃圾渗滤液高效生物脱氮.  相似文献   

10.
碳源对晚期垃圾渗滤液短程硝化的影响   总被引:1,自引:0,他引:1  
为了考察碳源对晚期垃圾渗滤液短程硝化的影响,采用“两级UASB-缺氧-好氧系统”处理城市生活垃圾晚期渗滤液.系统进水COD质量浓度为4.3g/L左右,进水氨氮质量浓度为2.8 g/L,故COD与氨氮质量浓度之比很低,为1.5左右.首先在UASB1中实现同时反硝化与产甲烷反应,一部分COD在UASB2中进一步去除,在A/O反应器中利用残余COD进行反硝化以及NH4+-N的彻底硝化.试验结果表明,未投外加碳源时,原水中可降解COD几乎全部作为一级UASB的反硝化碳源被利用,A/O池缺氧段反硝化碳源不足.在A/O池的A段投加相当于1 g/L COD质量浓度的无水乙酸钠作为电子供体促进反硝化后,由于反硝化产生大量的碱度,补充了硝化所消耗的碱度,使pH值维持在一个比较合适的范围,可实现稳定的短程硝化,亚硝态氮累积率由未投加碳源时的20%提高到87%,系统出水氨氮质量浓度为0.01 g/L左右,氨氮的去除率也由未投加碳源时的92%提高到99.6%.  相似文献   

11.
To investigate the shut-cut nitrification characteristics of aerobic granule,an aerobic granular sequencing batch airlift reactor(AG-SBAR) was carried out with mixed carbon sources of sodium acetate and glucose at 10±1 ℃.Results indicated that ammonia oxidizing bacteria was accumulated inside the aerobic granules and the reactor performed stably with shut-cut nitrification for a long term at low temperature.During the stable operation period,the effluent ammonia nitrogen concentration was maintained at 13.6 mg/L without nitrate and nitrite when the COD/N ratio was 20:1.However,the effluent concentration of ammonia nitrogen was below 0.5 mg/L with effluent nitrosation ratio of 96.7% on average when the COD/N ratio was reduced to 15:1 and 10:1.And the effluent phosphorus concentration was less than 0.4 mg/L during the stable period with the sludge retention time of 30 d.The phosphorus removal efficiency was not strongly influenced by the adjustment of COD/N ratio in this experiment.The removal efficiencies for COD,NH4+-N and PO43--P were 91.3%-94.6%,97.9%-99.7% and 97.1%-99.5%,respectively.  相似文献   

12.
采用UASB+A/O组合工艺处理养殖废水。在进水COD为6120 mg/L、BOD5为3850 mg/L、NH3-N为450 mg/L、SS为8300 mg/L时,出水COD为82 mg/L、BOD5为17 mg/L、SS为41 mg/L、氨氮为13 mg/L,去除率分别达到98.7%、99.56%、97.11%和99.51%,出水达到《畜禽养殖业污染物排放标准》GB (8978-96)一级排放标准。  相似文献   

13.
以某实际合成氨化工厂废水为研究对象,进行高氨氮化工废水缺氧/好氧(A/O)工艺高效短程生物脱氮中试研究.试验结果表明:A/O系统经过90 d的运行,实现了稳定的短程硝化,并获得了稳定的有机物和氮去除.亚硝态氮积累率维持在80%以上,COD、NH4+-N和TN的去除率分别达到了95%、99%和80%.此外,机理分析表明,A/O中试系统获得稳定短程硝化的主要因素为较低ρ(DO)、较高ρ(FA)及适宜HRT三者的协同调控.  相似文献   

14.
将ABR反应器与MBR反应器相结合,构建ABR/MBR优化组合工艺(CAMBR),并用于处理城市污水(pH6.5~8.5,温度25±1℃)。结果表明,CAMBR反应器在HRT为7.5 h,回流比为200%以及DO为3 mg/L时,反应器运行稳定,出水达到了《城镇污水处理厂污染物排放标准》(GB 18918-2002)一级A标准。出水COD、NH4+-N、TN和TP的平均浓度分别为24、0.4、10.6、0.31 mg/L;对应的去除率分别为93%、99%、79%和92%。膜池强化了系统去除功能,对NH4+-N、TN和TP的去除率分别为13%、10%和18%。  相似文献   

15.
Experiments were conducted to investigate the behavior of the sequential system of intensified zero-valent iron process(IZVI) and anaerobic filter and biological aerated filter(AF/BAF) reactors for advanced treatment of biologically pretreated coking wastewater. Particular attention was paid to the performance of the integrated system for the removal of chemical oxygen demand(COD), ammonia nitrogen(NH3-N) and total nitrogen(TN). The average removal efficiencies of COD, NH3-N and TN were 76.28%, 96.76% and 59.97%, with the average effluent mass concentrations of 56, 0.53 and 18.83 mg/L, respectively, reaching the first grade of the national discharge standard. Moreover, the results of gas chromatography/mass spectrum(GC/MS) and gel permeation chromatography(GPC) analysis demonstrated that the refractory organic compounds with high relative molecular mass were partly removed in IZVI process by the function of oxidation-reduction, flocculation and adsorption which could also enhance the biodegradability of the system effluent. The removal efficiencies of NH3-N and TN were achieved mainly in the subsequent AF/BAF reactors by nitrification and denitrification. Overall, the results obtained show that the application of IZVI in combination with AF/BAF is a promising technology for advanced treatment of biologically pretreated coking wastewater.  相似文献   

16.
采用IC-ALR的新型工艺处理含有大量蛋白质、碳水化合物的去油脂泔水。结果表明,在适应期采用快速提升负荷的方式有利于提高污泥的活性,加速污泥颗粒化;稳定运行期,当进水有机浓度达到22.4 g/L时,COD去除率高达91.7%,出水中9.2~10.1 mmol/L的VFA含量不会影响IC的稳定运行。利用ALR处理IC厌氧消化液,当进水COD和NH3-N浓度分别达到1 850和420 mg/L时,ALR反应器能够去除进水中75%的COD和91%的氨氮,出水COD和NH3-N浓度分别为420和40 mg/L。  相似文献   

17.
以城市二级处理出水为试验原水,通过逐渐提高滤速的方式,对停止运行近5个月的O/A两级生物砂滤池进行重新启动。重点研究了反应器的二次启动速度和启动后的脱氮除碳效果,以及C/N比对该工艺脱氮除碳效果的影响。试验结果表明,石英砂表面的生物膜并未死亡,通水运行后能在很短的时间内恢复正常。稳定运行期间,系统对CODCr和NH4+-N的平均去除率分别为45.53%和65.50%,出水CODCr和NH4+-N的平均浓度分别为48.50mg/L和4.12mg/L。当C/N比为5.0时,O/A两级生物砂滤池具有较高的TN脱除效果,TN去除率可达到30%以上,滤池出水TN含量低于15mg/L,均能达到一级A标准的要求。  相似文献   

18.
针对污水处理厂目前普遍存在碳源不足和剩余污泥量过大的问题, 以某小区低ρ(C)/ρ(N) 比生活污水为研究对象, 构建了多级好氧缺氧生物膜反应器, 考察了反应器脱氮、污泥减量效果及运行工况.试验表明反应器最优运行工况:流量分配比为3∶4∶3, HRT为11 h, ρ(DO) 为4.0 mg/L, 温度为25℃, 回流比R=1.0.在上述工况下, 当进水ρ(TN) 、ρ(NH4+-N) 、ρ(COD) 分别为80~130、75~100、260~400 mg/L时, ρ(TN) 出水约20 mg/L, ρ(NH4+-N) 、ρ(COD) 出水分别降至5.0、30 mg/L以下, TN、NH4+-N、COD平均去除率分别达到80%、95%、91%.多级好氧缺氧试验同时表明:反应器中的污泥产率仅为0.10, 优于其他生物膜工艺, 具有良好的污泥减量效果.  相似文献   